• Title/Summary/Keyword: Neutron Activation Analysis

Search Result 185, Processing Time 0.025 seconds

Verification of MCNP/ORIGEN-2 Model and Preliminary Radiation Source Term Evaluation of Wolsung Unit 1 (월성 1호기 MCNP/ORIGEN-2 모델 검증 및 예비 선원항 계산)

  • Noh, Kyoungho;Hah, Chang Joo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.21-34
    • /
    • 2015
  • Source term analysis should be carried out to prepare the decommissioning of the nuclear power plant. In the planning phase of decommissioning, the classification of decommissioning wastes and the cost evaluation are performed based on the results of source term analysis. In this study, the verification of MCNP/ORIGEN-2 model is carried out for preliminary source term calculation for Wolsung Unit 1. The inventories of actinide nuclides and fission products in fuel bundles with different burn-up were obtained by the depletion calculation of MCNPX code modelling the single channel. Two factors affecting the accuracy of source terms were investigated. First, the neutron spectrum effect on neutron induced activation calculation was reflected in one-group microscopic cross-sections of relevant radio-isotopes using the results of MCNP simulation, and the activation source terms calculated by ORIGEN-2 using the neutron spectrum corrected library were compared with the results of the original ORIGEN-2 library (CANDUNAU.LIB) in ORIGEN-2 code package. Second, operation history effect on activation calculation was also investigated. The source terms on both pressure tubes and calandria tubes replaced in 2010 and calandria tank were evaluated using MCNP/ORIGEN-2 with the neutron spectrum corrected library if the decommissioning wastes can be classified as a low level waste.

Analysis for the secondary gamma-ray emission for glasses irradiated with various doses of fast neutron: Case study borate and silicate glasses

  • O.L. Tashlykov;V. Yu. Litovchenko;N.M. Aristov;K.A. Mahmoud
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2366-2372
    • /
    • 2023
  • Are borate and silicate glasses suitable for working as shieling materials against fast neutrons? To correctly answer the above question, some silicate, and borate-based glasses were fabricated and irradiated with various doses of fast neutrons varied between 1.73 and 12.10 MGy. The color and hardness of the fabricated glasses were affected by the fast neutron fluence where the transparent glasses turned colored as well as the hardness of the fabricated glasses was decreased. The gamma-ray spectrometric analysis shows a high activity concentration produced in the barium borate glasses due to the formation of radioisotopes Ba-131 and Ba-133 reaches to 5.92E+05 Bq and 4.25E+03 Bq, respectively for sample Cd-5 Batch 3. Additionally, the gamma-ray spectrometric analysis for the sodium silicate glasses shows low activity concentrations emitted from isotopes formed due to the activation of Y2O3-associated impurities. These activities are low compared to that emitted by barium borate-based glasses.

An Improved Method for the Determination of Scandium by Neutron Activation Analysis (스칸듐定量을 위한 改良된 放射化分析法)

  • Chung, Koo-Soon;Lee, Chul
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.2
    • /
    • pp.88-91
    • /
    • 1964
  • A rapid and simple method is described here for the determination of scandium in monazite by neutron activation analysis. The sample is irradiated for 20 hours at the neutron flux of $10^{12}$ thermal neutrons/$cm^2$/sec in the TRIGA MARK Ⅱ reactor, after which the sample is decomposed by fusion with concentrated sulfuric acid. The scandium-46 together with scandium carrier are separated from the irradiated sample by precipitating with ammonia, and are extracted by solvent extraction of the thiocyanate complex into ether. The induced radioactivity is measured by gamma scintillation spectrometry using the Multichannel Pulse Height Analyzer connected with 2"${\times}$2" NaI(Tl). The chemical yield is determined gravimetrically by precipitating scandium with mandelic acid. In order to check the efficiency of scandium separation and the errors from interfering activities of the other elements, scandium was separated by the cation exchange resin column, and the results from both samples were compared each other, which showed that the chemical procedure used in this work was as selective as the ion-exchange method with respect to scandium separation. The scandium contents in Korean monazite were found to be about 12 p. p. m.

  • PDF

Determination of Inorganic Elements in Women Blood Serum using Instrumental Neutron Activation Analysis (중성자방사화분석법을 이용한 성인여성 혈청중의 무기 원소 분석)

  • Moon, Jong-Hwa;Chung, Yong-Sam;Lee, Ok-Hee
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.509-513
    • /
    • 2002
  • In this study, instrumental neutron activation analysis was used to assess the concentration level of inorganic trace elements in Korean women blood serum. It was found out that high concentration of Na and Cl incurs analytical interference, but 12 elements of Br, Ca, Cl, Co, Cr, Cs, Fe, K, Na, Rb, Se, Zn can be determined under the condition of interference minimization. Serum samples collected from 63 women were analyzed and the concentration level and range of the elements were evaluated. NIST SRMs were analyzed simultaneously for analytical quality control. The average values of Na and Cl determined in serum samples are around 3000 mg/L, Ca is 100 mg/L and K is 200 mg/L. Besides, Br, Se and Zn have concentration level of 6.0, 0.1 and 1.0 mg/L, respectively. It was found that there is no significant difference between the present values and reported values.

Assessment of Nuclear Characteristics of NAA #1 Irradiation Hole in HANARO Research Reactor for Application of the $K_0$-NAA Methodology

  • Moon, Jong-Hwa;Kim, Sun-Ha;Chung, Yong-Sam;Dung, Ho-Mahn
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.566-573
    • /
    • 2002
  • Neutron activation analysis based on $textsc{k}$$_{o}$-standardization method# ($textsc{k}$o-NAA) is Com as one of the most remarkable progresses of the NAA with advantages of experimental simplicity, high accuracy, excellent flexibility with respect to irradiation and counting conditions, and suitability for computerization. This study was carried out to determine the reactor neutron spectrum parameters, i.e. $\alpha$ and f as the main factors of irradiation quality at NAA #1 irradiation hole on HANARO research reactor, to evaluate peak detection efficiency of the gamma-ray spectrometer for the use in the $textsc{k}$$_{o}$ experiments and to compare the measured concentration results with the certified values of some SRMs applying the experimentally determined to-parameters.ers.

Investigation of Dynamic Elemental Distribution in Six Human Tissues by Neutron Activation Analysis (중성자방사화분석에 의한 인체 6개 조직 내 기능성원소 함량 분포 조사)

  • Kang, Sang-Hoon;Moon, Jong-Hwa;Chung, Yong-Sam;Cho, Seung-Yeon;Lee, Han-Young
    • Analytical Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.365-372
    • /
    • 2002
  • In this study, inorganic elemental distribution in Korean adult human tissue of liver, lung, muscle, kidney, rib and thyroid has been investigated. These tissues were collected from human's body within 48 hours after their death according to IAEA's recommended method, dried by freeze drying method and then pulverized. Neutron activation analysis was applied to these samples to determine the concentrations of 5 major elements of Ca, Mg, Na, K, and Cl and 12 trace elements of Mn, I, Sr, As, Br, Co, Cr, Cs, Fe, Rb, Se, and Zn. To confirm accuracy of analytical result was performed using three kinds of standard reference materials and resulted that the relative error is within 10% for the most of elements and the Z-score indicating a performance of analysis is within 2. The elemental distribution shows that the major elements are distributed homogeneously with a specific concentration and that the trace elements shows a distribution of different concentration with kinds of tissue and their age. Particularly, iodine shows higher concentration with 1000 ${\mu}g/g$ in thyroid, and calcium and strontium show the concentration with 15.9% and 84.4 ${\mu}g/g$ in rib, respectively.

AN EXPERIMENTAL STUDY ON THE MEASUREMENT OF MARGINAL LEAKAGE USING A NEUTRON ACTIVATION ANALYSIS (Neutron Activation Analysis를 이용한 Composite Resin의 변연누출 측정에 관한 실험적 연구)

  • Kim, Mi-Ja;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.185-190
    • /
    • 1988
  • The study was designed to establish quantitative method for assessing the marginal leakage of dental restorations. 18 Class V cavities with $45^{\circ}$ bevel joint were prepared and replicas of these teeth were made with polyethylene wax. and classified with three groups. First group was filled with Scotch bond and silux. Second group was filled with glass ionomer cement:scotchbond/silux. Third group was filled with Dentin-Adhesit/Heliosit. After finishing, all specimens were subjected manually to 100 thermal cycles at $0^{\circ}C$ and $100^{\circ}C$ Samarium nitrate solution, irradiated with flux of $6{\times}12^{12}$ neutrons/$cm^2$/sec for 11 hours, woled for 200 hours, counted with the HpGe detector and the tracer uptake was determined by comparison with a standard of samarium ($10{\mu}g$). The following results were obtained. 1) The group filled with glass ionomer cement base showed least marginal leakage. 2) The group filled with Dentin-Adhesit/Heliosit showed less marginal leakage than the group filled with scotchbond/silux.

  • PDF

The distribution characteristics of trace elements of fine ambient particulate in Korea

  • Lim, Jong-Myoung;Lee, Jin-Hong;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.241-249
    • /
    • 2005
  • In this study, instrumental neutron activation analysis was used to measure the concentrations of about 30 trace elements in airborne particulate (PM2.5) samples at urban area of Daejeon city located in the southwestern region of Korea. An inspection of the measurement data indicates that the distribution patterns of trace elements could clearly distinguish the elements with their concentrations ranging over five orders of magnitude. The mean values for Lu and Dy were found to be the lowest at values of 0.01 and $0.04ng/m^3$, while those for K and Fe showed the highest value of 671 and $653ng/m^3$, respectively. The results of correlation analysis showed that PM2.5 concentrations can exhibit much more enhanced correlations with the elements of earth crustal components. The results of factor analysis further indicated that there are no more than six factors with statistical significance, which may exert dominant roles in regulating the elemental concentration levels in the study area. Enrichment factor analysis supports explicit interpretation of results found by this factor analysis.

중성자 방사화분석에 의한 한국자기의 분류

  • Gang, Hyeong-Tae;Lee, Cheol
    • 보존과학연구
    • /
    • s.6
    • /
    • pp.111-120
    • /
    • 1985
  • Data on the concentration of Na, K, Sc, Cr, Fe, Co, Cu, Ga, Rb, Cs, Ba, La,Ce, Sm, Eu, Tb, Lu, Hf, Ta and Th obtained by Neutron Activation Analysishave been used to characterise Korean porcelainsherds by multivariate analysis. The mathematical approaches employed is Principal Component Analysis(PCA).PCA was found to be helpful for dimensionality reduction and for obtaining information regarding (a) the number of independent causal variables required to account for the variability in the overall data set, (b) the extent to which agiven variable contributes to a component and(c) the number of causalvariables required to explain the total variability of each measured variable.

  • PDF

Quality Assurance and Control for Elemental Analysis of Air Dust by Neutron Activation Analysis (중성자 방사화분석에 의한 대기먼지 중 원소분석을 위한 품질보증 및 관리)

  • 문종화;김선하;임종명;정용삼;김영진
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.11a
    • /
    • pp.229-230
    • /
    • 2003
  • 중성자 방사화분석법은 핵반응을 통해 생성시킨 방사성 동위원소로부터 방출되는 방사선을 검색하여 절대적으로 성분원소를 정량하는 핵분석기술(Nuclear Analytical Techniques)이다. 현재 한국원자력연구소의 중성자 방사화분석실에서는 대기환경분야 응용연구로서 수년 동안 대기분진을 채집하여 미량 성분원소를 정량하고 있으며, 방법의 유효화와 측정결과의 신뢰성을 확보하기 위하여 시료의 채집 및 준비, 원소분석, 측정결과의 검증 등 분석과정에 대한 품질관리를 수행하고 있다. (중략)

  • PDF