• Title/Summary/Keyword: Neutralization Line

Search Result 23, Processing Time 0.016 seconds

A Study on the Improvement of MIMO Antenna Isolation for Mobile Applications (휴대 단말기용 MIMO 안테나의 격리도 향상에 관한 연구)

  • Yoon, In-Seop;Yan, Xiao-Jia;Kim, Sang-Uk;Jo, Yun-Hyun;Park, Hyo-Dal
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.9
    • /
    • pp.987-992
    • /
    • 2015
  • In this paper, neutralization line structure have been employed to improve the isolation between the MIMO antenna system. The proposed MIMO antenna size is $116mm{\times}64mm{\times}5mm$ and designed on FR-4(${\varepsilon}r=4.4$) ground substrate. Neutralization line was applied to enhance isolation between the each antenna elements. The fabricated antenna satisfied a VSWR below 3 in LTE band B13 and the isolation between the MIMO antenna system is presented below -15dB. On the H-plane, antenna shows an omnidirectional pattern. In LTE band B13, the antenna presents a gain of a -2.6dBi ~-1.18dBi and radiation efficiency of 33.49% ~ 46.45%. Comparing measurement result with the outcome of simulation, the proposed MIMO antenna is expected to be applied for mobile application.

Ion Induced Secondary Electron Emission of MgO with Patterned Gold Line Charge Neutralization

  • Lee, Jong-Wan;Lee, Kie-Young;Kim, Hong-Gyu;Ahn, Joon-Hyung;Jung, Won-Joon;Yoon, Sean-J;Byungdu Oh
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.5 no.1
    • /
    • pp.7-10
    • /
    • 2001
  • Ion induced secondary electron emission coefficients γ of protecting layers of an AC plasma display panel(AC-PDP) have been measured. In order to solve the surface charging effect during the measurement at insulating samples like MgO, a new method with the patterned gold line charge neutralization has been introduced. The measurement was performed at the samples, MgO and MgO+MgF$_2$, which showed a great difference in the firing voltage between the two protecting layers. The γ value has been compared with the firing voltage Vf of the AC-PDP with the same protecting layer. Correct relationship between γ and Vf has been observed. Thus, the patterned gold line method has been proven to be successful for the measurement of the secondary electron emission yield at insulator sample surfaces.

  • PDF

Effect of coagulation conditions on ultrafiltration for wastewater effluent

  • Maeng, Sung Kyu;Timmes, Thomas C.;Kim, Hyun-Chul
    • Membrane and Water Treatment
    • /
    • v.8 no.2
    • /
    • pp.185-199
    • /
    • 2017
  • Low-pressure membrane filtration is increasingly used for tertiary treatment of wastewater effluent organic matter (EfOM), mainly comprising organic base/neutral compounds. In-line coagulation with underdosing, charge neutralization, and sweep floc conditions prior to ultrafiltration (UF) was studied to determine removals of the EfOM components and consequent reduction of fouling using polyethersulfone membranes. Coagulation and UF substantially reduced fouling for all coagulation conditions while removing from 7 to 38% of EfOM organic acids. From 7 to 16% of EfOM organic base/neutrals were removed at neutral pH but there was no significant removal for slightly acid coagulation conditions even though fouling was substantially reduced. Sweep floc produced the lowest resistance to filtration but may be inappropriate for in-line use due to the large added volume of solids. Charge-neutralization resulted in poor recovery of the initial flux with hydraulic cleaning. Under-dosing paralleled sweep floc in reducing hydraulic resistance to filtration (for sub-critical flux) and the initial flux was also easily recovered with hydraulic cleaning. Hydrophobic and hydrophilic base/neutrals were identified on the fouled membranes but as previously reported the extent of fouling was not correlated with accumulation of organic base/neutrals.

Adaptive Nonlinear Constrained Predictive Control of pH Neutralization in Fed-batch Bio-reactor

  • Zhe, Xu;Kim, Hak-Kyeong;Kim, Sang-Bong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.90-95
    • /
    • 2003
  • In this paper, an Adaptive Nonlinear Constrained Model Predictive Control (ANCMPC) is presented for a pH control in a fed-batch bio-reactor. The pH model is represented with Hammerstein Model. The static nonlinear part of Hammerstein model is described with the static pH model, and the dynamic linear part of the Hammerstein model is described with the CARIMA model. The parameters of the CARIMA model is estimated on-line with the input and output measurements of the system using a recursive least squares type of identi�cation algorithm. The e�ectiveness of the proposed controller is shown through simulations.

  • PDF

Development of a Concentration Measurement System for Pickling Line Control (산세라인 자동화를 위한 농도 측정 시스템 개발)

  • Park, Hyoung-Kuk;Lee, Jong-Hyun;Noh, Ill-Hwan
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.891-895
    • /
    • 2013
  • This paper proposes the development of a new method for online analysis which measured acid concentration in a pickling line. Pickling is the most important step to remove surface scale layers and is strongly depending on the exactly controlled pickling liquor composition. Today, there is no feasible system available for the online control of pickling lines. Within this paper, new methods for online analysis of pickling liquors have been tested and implemented into an overall pickling process control tool. This method measured simultaneously the hydrochloric acid and iron ion concentration in a solution of hydrochloric acid by measuring the ultrasonic speed, the solution temperature, and the electrical conductivity. Experimental results showed excellent precision and the measurement error was ${\pm}2g/l$ compared with the neutralization titration measurement.

The Production IL-21 and VEGF in UVB-irradiated Human Keratinocyte Cell Line, HaCaT

  • Kim, Hye-Min;Kang, Jae-Seung;Lee, Wang-Jae
    • IMMUNE NETWORK
    • /
    • v.10 no.2
    • /
    • pp.76-81
    • /
    • 2010
  • Ultraviolet B (UVB) induces multiple inflammatory and carcinogenic reactions. In skin, UVB induces to secrete several kinds of inflammatory cytokines from keratinocytes and also increases angiogenic process via the modulation of vascular endothelial growth factor (VEGF) production. Interleukin-21 (IL-21) is an inflammatory cytokine and produced by activated T cells. The biologic functions of IL-21 have not yet extensively studied. In the present study, we investigate the production of IL-21 from human keratinocyte cell line, HaCaT and its biological effect after exposure to UVB. First, we confirmed the IL-21 production and its receptor expression in HaCaT. And then, the change of IL-21 and VEGF production in HaCaT by UVB irradiation was examined. Not only IL-21 but also VEGF production was enhanced by UVB irradiation. Next, to determine relationship of enhanced production of IL-21 and VEGF, we detected VEGF production after neutralization of IL-21. VEGF production was reduced by IL-21 neutralization, which indicates that the IL-21 is involved in the VEGF production. Taken together, our results suggest that IL-21 and VEGF production is enhanced by UVB irradiation in HaCaT. In addition, it seems that IL-21 plays a role in the angiogenic process in skin via the modulation of VEGF production.

Production, Characterization, and Variable Region Analysis of Monoclonal Antibodies Specific for Hepatitis B Virus S Antigen (Hepatitis B Virus의 S항원에 특이적인 단세포군 항체 생산, 특성 연구 및 가변지역유전자 분석)

  • Song, Moo-Young;Kim, Chang-Seok;Park, Sang-Koo;Lee, Jae-Sun;Yoo, Tae-Hyoung;Ko, In-Young
    • IMMUNE NETWORK
    • /
    • v.3 no.4
    • /
    • pp.281-286
    • /
    • 2003
  • Background: Hepatitis B virus (HBV) infection is one of the worldwide public health problem affecting about 300 million people. The envelope protein of HBV consists of three components known as preS1, preS2, and S antigen. According to the recent study, anti-HBs Ab showed effective neutralization ability against HBV from chronic hepatitis B and liver transplant patients, suggesting the possible development of therapeutic antibody. Methods: Spleen cells immunized with S antigen of HBV were fused with myeloma cell line to obtain HBsAg specific monoclonal antibodies. High affinity antibodies against HBsAg (adr, ad and ay type) were selected by competitive ELISA method. Nucleotide sequence of the variable regions of monoclonal antibodies was analyzed by RT-PCR followed by conventional sequencing method. Results: We produced 14 murine monoclonal antibodies which recognize S antigen of HBV. Two of them, A9-11 and C6-9 showed the highest affinity. The sequence analysis of A9-11 revealed that variable regions of the heavy chain and light chains are members of mouse heavy chain I (B) and light chain lambda 1, respectively. Likewise, the sequence analysis of C6-9 revealed that variable regions of the heavy chain and light chains are members of mouse heavy chain II (B) and light chain kappa 1, respectively. Neutralization assay showed that A9-11 and C6-9 effectively neutralize the HBV infection. Conclusion: These results suggest that A9-11 and C6-9 mouse monoclonal antibodies can be used for the development of therapeutic antibody for HBV infection.

Development of Texture Neutralization System for the Invisible e-Performance (투명 e-퍼포먼스를 위한 텍스쳐 중화 시스템 개발)

  • Lee, Dong-Hoon;Yun, Tae-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.4
    • /
    • pp.585-594
    • /
    • 2011
  • On live performance such as play and musical, various stage effects are utilized to attract a diverse audience. These stage effects include traditional direction techniques, striking display effects and all kinds of ways of being immersed in the scene. In this paper, we propose a novel digital visual effects(digilog) for controlling the surface texture of objects based on spatial augmented reality. For this purpose, we present a method of neutralizing the appearance of an arbitrary object using a projector-camera system. To make the object appear as if it is a transparent object by projecting a carefully determined compensation image onto the surface of objects, we use the homography method for a simple and effective off-line projector-camera calibration. The successful uses of the basic algorithm of Smart Projector for measuring radiometric parameters led us believe that this method may be used for temporal variation of plays and musicals.

Neutral Beam Evolution in the KSTAR NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • The pressure distributions in the test stand built for developing KSTAR NBI ion sources were obtained using a network system composed of conductance elements modeling the ion source, the neutralizer, and other beam line components. The allowable regime was defined on the coordinates of the gas supply rate to the ion source and the neutralizer, considering the proper conditions of the three critical parameters, the ion source pressure for good arc discharge, the pressure integral in the neutralizer for sufficient neutralization, and the chamber pressure for minimum neutral beam loss. The neutral beam evolution along the path from the ion source extraction grid to the calorimeter through the neutralizer, the bending magnet and the vacuum chamber was estimated for typical pressure distributions.

  • PDF