혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향 (A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line)

  • 전용주;전명수
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

중성점을 사용하지 않는 BLDC 전동기 센서리스 제어 기법 (Sensorless Control Method of the BLDC Motor Without Neutral Point)

  • 심광렬;안정렬
    • 전기학회논문지P
    • /
    • 제61권3호
    • /
    • pp.111-115
    • /
    • 2012
  • Generally, brushless DC motor(BLDCM) driving system uses hall sensors or encoders as the mechanical position or speed sensor. It is necessary to achieve the informations of rotor position for driving trapezoidal type brushless DC motor without any position sensor. In this paper, the commutation signals are obtained without the motor neutral voltage, multistage analog filters, A/D converters, or the complex digital phase shift circuits which are indispensable in the conventional sensorless control algorithms. In the proposed method, in stead of detecting the zero crossing point of the nonexcited motor back electromagnetic force for the average motor terminal to neutral voltage, the commutation signal are extracted directly from the specific average line to line voltage with low-pass filter, adder and comparators circuit. In contrast to conventional methods, the neutral voltage is not need; therefore, the commutation signals are insensitive to the common mode noise. Moreover, the complex phase shift circuit can be eliminated. The effectiveness of the proposed method is verified through simulation results.

선박의 저항접지 시스템에서 지락 고장에 따른 대지전압 중성점 전위 특성 (Characteristics on the Neutral Point Potential of Line-to-Ground Voltage according to Line-to-Ground Fault in Resistance Ground System for Ships)

  • 이윤형;류기탁
    • 한국산학기술학회논문지
    • /
    • 제19권5호
    • /
    • pp.689-696
    • /
    • 2018
  • 계통 접지(system grounding)는 어떤 이상전압 유입이나 지락 고장 등으로부터 전력 계통의 안정성을 확보할 목적으로 전원의 중성점에 적용하는 것이다. 선박에서 주로 적용되는 계통 접지는 비접지 시스템과 저항 접지 시스템이다. 440V 선박은 비접지 시스템을 적용하고, 3.3kV, 6.6kV, 11kV의 MV(medium voltage) 시스템을 사용하는 선박은 저항 접지 시스템 중에서 주로 고저항접지 방식을 적용한다. 지락 고장은 전기시스템에서 발생하는 모든 고장의 95%정도이고, 지락고장 발생 시 전력 계통의 대지전압이 과도하게 증가하여 선내 절연 시스템에 악영향을 주게 된다. 본 논문에서는 선박에서 적용하는 저항접지 시스템에 대해 지락 고장 발생시 지락 정도에 따라 전력 계통의 대지전압 중성점의 변동 특성을 확인하고자 한다. 이를 위해 우선 접지 시스템의 종류에 따른 특성을 알아보고, 선박의 저항 접지 시스템의 대지전압 중성점에 대한 모델링을 유도한다. 최종적으로 다양한 변수환경에 따라서 대지전압, 선간전압, 중성점 전위 등이 어떻게 변동되는지 MATLAB을 이용한 시뮬레이션을 통해 지락고장 발생시 나타나는 선내 전압의 변화특성을 분석한다.

계통연계형 3상 3레벨 태양광 인버터의 중성점 전압제어 (Neutral Point Voltage Control for Grid-Connected Three-Phase Three-Level Photovoltaic Inverter)

  • 박운호;양오
    • 반도체디스플레이기술학회지
    • /
    • 제14권4호
    • /
    • pp.72-77
    • /
    • 2015
  • Three-level diode clamped multilevel inverter, generally known as neutral point clamped (NPC) inverter, has an inherent problem causing neutral point (NP) potential variation. Until now, the NP potential problem of variation has been investigated and lots of solutions have also been proposed. This paper presents a neutral point voltage control technology using the anti-windup PI controller and offset technology of PWM (Pulse Width Modulation) to control the variation of NPC 3-phase three-level inverter neutral point voltage. And the proposed algorithm is tested and verified using a PLL (Phase Locked Loop) in order to synchronize the phase voltage from the line voltage of grid. It significantly improves the voltage balancing under a solar fluctuation conditions of the inverter. Experimental results show the good performance and effectiveness of the proposed method.

22.9kV 혼합배전선로의 뇌과전압 해석 및 중성선 유기 전압 해석 (Analysis of Lighting Overvoltage and Induced Voltage of Neutral Line on the 22.9kV Combined Distribution Line)

  • 홍동석;이종범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.510-512
    • /
    • 2000
  • This paper describes the voltage induced at neutral line and the proper location of lightning arrester in combined 22.9 kV class distribution line jointed overhead line and cable each other Modeling is established in ATP Draw to perform simulation. Simulated distribution line at this paper consists of distribution line 4.2km and underground distribution line 2km. Overvoltage and induced voltage are analyzed at several point of combined line. Analysis results was compared to select the best point to install arrester. Such analysis technology will be applied to obtaining capacity and location of arrester in the similar combined distribution line.

  • PDF

가공 배전선의 전자유도전압에 대하여 대지 귀로전류 원리를 반영한 중성선 차폐계수 계산 방법 (The Calculation Method of Shielding Coefficient of Neutral Line against an Induced Voltage by an Aerial Power Distribution Line Reflecting the Principle of Earth Return Current)

  • 이상무
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.86-91
    • /
    • 2016
  • 가공배전선에 의하여 통신선에 유도되는 전압을 계산하는데에 있어서 기존의 중성선 차폐계수를 단일의 값으로 사용함으로 인한 과다 오차 발생 문제를 해결하기 위하여 실제 배전 구간의 전주 접지 마다 발생하는 누설전류에 의한 대지귀로전류의 영향이 반영된 일반식이 개발된 바 있다. 각 전주 접지에서 발생하는 누설전류의 근원은 중성선에 유입되는 불평형전류이다. 그러므로 누설전류와 그 합인 대지귀로전류는 이 불평형전류에 대한 각 전주 위치에서의 누설율들의 합성적 인수 관계로 표현이 가능하다. 본 논문에서는 결국 원래의 일반식을 누설율의 관점에서 전개하여 좀더 실용적인 의미를 갖도록 하였다. 이렇게 하면 유도의 원천 전류인 중성선 불평형전류에 대한 누설전류 요율만의 합성 인수로 대체된 중성선 차폐계수 계산식이 도출된다. 이 계산식의 의미는 전 배전 구간에서 중성선에 의한 차폐 효과가 일정한 것이 아니라 유도 구간의 위치에 따라서 원래 유도를 발생시키는 전류인 중성선 불평형전류의 양이 달라지는 요율을 말한다는 것이다. 이와 같은 방식으로 계산하였을 때 기존 방식에 비하여 과소 예측에 대하여는 14% 증진율을, 과다 예측에 대하여는 평균 1/10 수준으로의 감소 효과를 기대할 수 있다.

집전전압 향상을 위한 가변탭 단권변압기 검토 (Evaluation of the variable TAB Autotransformer for ascending collecting Voltage)

  • 이장무;한문섭;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1426-1430
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing electric load at feeding system, collecting voltage of train and end voltage are going down. So to increase voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

중성선 선로 전압강하를 이용한 단락사고 방지용 보호장치 개발 (Development of Prevention Apparatus for Short-Circuit Faults Using the Line Voltage Drop of Neutral Wire)

  • 곽동걸;김진환;이봉섭
    • 전기학회논문지
    • /
    • 제61권12호
    • /
    • pp.1953-1958
    • /
    • 2012
  • The major causes of electrical fire are classified to short circuit fault, overload fault, electric leakage and electric contact failure. The occurrence factor of the fire is electric arc or spark accompanied with such electric faults, specially short circuit faults. Earth Leakage Circuit Breaker (ELB) and Molded_case Circuit Breaker (MCCB), that is, Residual Current Protective Devices (RCDs) used on low voltage distribution lines cut off earth leakage and overload, but the RCD can not cut off electric arc or spark to be a major factor of electrical fire. As the RCDs which are applied in low voltage distribution panel are prescribed to rated breaking time about 30ms(KS C 4613), the RCDs can't perceive to the periodic electric arc or spark of more short wavelength level. To improve such problem, this paper proposes a prevention apparatus using the line voltage drop of neutral wire and some semiconductor switching devices. Some experimental tests of the proposed apparatus confirm the validity of the analytical results.

병행 배전선로에서의 통신선 유도전압 계산 (Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines)

  • 김현수;이상봉;여상민;김철환;류승헌;김성암;원봉주
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).