교육용 건물의 중성선 고조파 전류 측정 및 모델링 (Measurements and Modeling of Neutral Harmonic Currents on the Education Office Building)

  • 김경철;강윤모;이일무
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.111-116
    • /
    • 2002
  • With the proliferation of nonlinear loads such as personal computers in an educational office building, high neutral harmonic currents have been observed. High neutral currents in three-phase four-wire distribution power systems can cause overloaded neutral conductors, overloaded transformers, voltage distortion, common mode noise, and malfuntion of protective equipment. On-site measurements of harmonic currents and voltages were made and the corresponding equivalent circuits was developed. The circuit model under study was simulated numerically and graphically through the use of the software MATLAB.

  • PDF

상업용 설비 부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구 (A Study on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Commercial Facility Loads)

  • 김경철;이일무;백승현
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.54-60
    • /
    • 2004
  • 현대 사회 전반에 걸쳐 개인용 컴퓨터와 같은 비선형 부하가 증가하여, 중성선에는 많은 고조파 전류가 흐른다. 3상 4선식 배전계통을 채용하는 중성선에 과다한 고조파 전류가 흐르면 여러 가지 고조파 장해를 일으킨다. 중성선 고조파 저감 대책으로 지그재그 변압기를 이용하는 영상 필터가 널리 쓰이고 있다. 본 논문에서는 상용화된 중성선 영상 전류 저감장치를 분석하고, 고조파를 저감시키기 위해서 상업용 설비 부하에 적용하고자 한다. 실측한 값과 MATLAB으로 시뮬레이션 한 값을 수치와 그래프로 비교해 보았다.

조명부하의 중성선 영상전류 저감장치 분석 및 적용에 관한 연구 (A Stduy on the Analysis and Application of Neutral Line Zero Sequence Currents Reduction Device in Lighting Loads)

  • 김경철;이일무;정영호;백승현
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.59-64
    • /
    • 2004
  • 현대 사회 전반에 걸쳐 조명설비와 같은 비선형 부하가 증가하여, 중성선에는 많은 고조파 전류가 흐른다. 3상 4선식 배전계통을 채용하는 중성선에 과다한 고조파 전류가 흐르면 여러 가지 고조파 장해를 일으킨다. 중성선 고조파 저감 대책으로 지그재그 변압기를 이용하는 영상 필터가 널리 쓰이고 있다. 본 논문에서는 상용화된 중성선 영상 전류 저감장치를 분석하고, 고조파를 저감시키기 위해서 조명 부하에 적용하고자 한다. 실측한 값과 MATLAB으로 시뮬레이션한 값을 수치와 그래프로 비교해 보았다.

현장시험에 의한 중성선 고조파 전류 측정, 모델링 및 수동필터 적용에 관한 연구 (A Study on the Measurements, Moldeling, and Passive Filter Application of Neutral Hormonic Currents by Field Tests)

  • 김경철;강윤모;이일무
    • 조명전기설비학회논문지
    • /
    • 제17권1호
    • /
    • pp.103-111
    • /
    • 2003
  • 교육용 건물에는 개인용 컴퓨터와 같은 비선형 부하가 증가하여, 중성선에는 많은 고조파 전류가 흐른다. 3상 4선식 배전 계통을 채용하는 중성선에 과다한 고조파 전류가 흐르면 중성선 도체 과열과 보호 시스템의 오동작등 많은 고조파 장해를 일으킨다. 본 논문에서는 현장에서 실측한 고조파 전류와 전압으로 고조파 해석용 3상 등가회로를 구성하였다. 실측한 값과 MATLAB으로 시뮬레이션한 값을 수치와 그래프로 비교 검토 하였다. 또한 중성선 고조파 전류 저감 대책으로 동조 수동 필터를 사례연구 시스템에 적용하여 고조파 저감 효과도 알아 보았다.

3상4선식 계통에서 중성선 영상고조파 저감에 따른 기대효과 (The expectation effects of a decrease in neutral wires Zero Sequence harmonic currents in 3 phases - 4 wires systems)

  • 강창원;이성우;정연해;김세동;이원구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.715-719
    • /
    • 2002
  • Recently, Dangers due to harmonics emanated from all sorts of machinery have been on the increase with the development in industry. One of them is that Zero Sequence harmonic currents flow from the neutral wires in 3 phases - 4 wire systems. The flowing of harmonic currents in neutral wires brings about the superheating and falloff in output of transformer, the overheating of them, a rise in ground potential and the wrong movement of machinery, so has a bad influence on this system. To develop the machinery to decrease neutral wires Zero sequence harmonic currents and apply it help solve these problems and bring about the effects of a improvement in power factor and energy savings.

  • PDF

접지 임피던스가 중성선 고조파 전류에 미치는 영향 (The Ground Impedance Influence on Neutral Harmonic Currents)

  • 김경철;백승현;이일무;김종욱
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.120-127
    • /
    • 2004
  • 스위칭 모드 전원 공급 장치와 같은 비선형 부하의 증가로, 3상 4선식 배전계통을 채용하는 중성선에 많은 고조파 전류가 흐른다. 중성선은 접지 시스템과 연결되어 있기 때문에 접지 임피던스는 중성선 고조파 전류에 영향을 끼친다고 알려져 있다. 현장에서 실측한 고조파 전류와 전압으로 고조파 해석용 3상 등가 회로를 구성하였다. 실측한 값과 MATLAB으로 시뮬레이션 한 값을 수치와 파형으로 비교 검토하였다. 또한 본 논문에서는 중성선 고조파 전류와 접지 임피던스와의 관계를 시뮬레이션을 통해 검증하였다.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • Journal of Power Electronics
    • /
    • 제3권3호
    • /
    • pp.151-158
    • /
    • 2003
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other This may result in wiring failure of the neutral conductor and overloading of the distribution transformer In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system This remedies overloading and power loss of the system The experimental results on a prototype validate the proposed control approach.

Performance Improvement of an Active Neutral Harmonic Suppressor System Under Unbalanced Load Conditions

  • Choi, Se-Wan;Jang, Min-Soo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.822-828
    • /
    • 2001
  • Three-phase four-wire electrical distribution systems are widely employed in manufacturing plants, commercial and residential buildings. Due to the nonlinear loads connected to the distribution system, the neutral conductor carries excessive harmonic currents even under balanced loading since the triplen harmonics in phase currents do not cancel each other. This may result in wiring failure of the neutral conductor and overloading of the distribution transformer. In response to these concerns, a cost-effective neutral current harmonic suppressor system has been proposed [6]. This paper proposes an improved control method for the harmonic suppressor system under unbalanced load conditions. The proposed control method compensates for only the harmonic components in the neutral conductor, and the zero-sequence fundamental component due to unbalanced loading is prevented from flowing through the harmonic suppressor system. This remedies overloading and power loss of the system. The experimental results on a prototype validate the proposed control approach.

  • PDF

Pattern Search 법을 이용한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling using pattern Search Method for Neutral Hormonic Analysis)

  • 백승현;김경철;최종기;이일무;백남웅
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.181-187
    • /
    • 2004
  • 3상 4선식 배전계통을 채용하는 우리나라는 비선형 부하의 증가로 중성선에는 많은 중성선 고조파 전류가 관측되고 있다. 또한 접지 임피던스는 고조파가 있는 중성선 전류에 영향 끼친다고 알려져 있다. 전위 강하법에 따라 현장에서 실측한 고조파 전류와 전압을 측정하고, Pattern Search 기법으로 고조파 해석용 접지 임피던스를 모델링 하였다. 여기서 구한 임피던스 모델은 현장 시험에 의한 임피던스 모델과 비교하여 유사한 결과를 얻었고, 접지 시스템의 고조파 및 과도 응답 특성을 평가하는데 활용될 것으로 사료된다.

현장시험에 의한 중성선 고조파 해석용 접지 임피던스 모델링 (The Ground Impedance Modeling for Neutral Harmonic Analysis by Field Tests)

  • 김경철;백승현;최종기;이일무;김종욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.369-371
    • /
    • 2004
  • With the proliferation of nonlinear loads, high neutral harmonic currents in three-phase four-wire distribution system have been observed. It has been. known that the ground impedance has an effect on the neutral currents of a system which operates with harmonics present. On-site measurements of harmonic currents and voltages according to the fell-of-potential method under case study system were made and the ground impedance modeling using the pattern search method for the harmonic analysis was developed. The ground impedance model obtained by the proposed method was compared with the frequency characteristics by field tests and has shown appropriate results, and would be applicable to evaluate the harmonic and transient response characteristics of the ground system.

  • PDF