• Title/Summary/Keyword: Neutral System

Search Result 1,091, Processing Time 0.024 seconds

Characteristics of the SFCL by turn-ratio of three-phase transformer

  • Jeong, I.S.;Choi, H.S.;Jung, B.I.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.4
    • /
    • pp.34-38
    • /
    • 2013
  • According to the increase of electric consumption nowadays, power system becomes complicated. Due to this, the size of single line-to-ground fault from power system also increases to have many problems. In order to resolve these problems effectively, an Superconducting Fault Current Limiter(SFCL) was proposed and continuous study has been done. In this paper, an SFCL was combined to the neutral line of a transformer. An superconductivity has the characteristics of zero resistance below critical temperature. because of this, SFCL has nearly zero resistance. so we connecting SFCL to neutral line will not only have any loss in the normal operation but also have the less burden of electric power because of only limiting the initial fault current. We analyzed the characteristics of current, voltage according to the changes of turn ratio of 3 phase system in case of combinations of an SFCL to the neutral line. It was confirmed that the limiting rate of initial fault current by the increase of turn ratio was reduced.

Analysis on the Protective Coordination on Neutral Line of Main Transformer in Power Distribution Substation with Superconducting Fault Current Limiter (MTR 중성점 접지에 초전도 전류제한기 적용시 지락과전류계전기 동작 분석)

  • Kim, Jin-Seok;Lim, Sung-Hun;Moon, Jong-Fil;Kim, Jae-Chul;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2089-2094
    • /
    • 2009
  • The fault current has increased due to growth of distributed generations for the large power demand in power distribution system. To solve some problem such as excess of the circuit breaker's cut-off ratings, the superconducting fault current limiter(SFCL) has been progressed. However, the operational characteristics of the relay is changed by SFCL. Therefore, the proper impedance for the SFCL should be selected to keep protective coordination with the SFCL when SFCL is introduced on the neutral line of main transformer in distribution system. In this paper, the proper normal conducting resistance was suggested to solve the problem in case of the protection coordination with SFCL.

REGULARITY FOR FRACTIONAL ORDER RETARDED NEUTRAL DIFFERENTIAL EQUATIONS IN HILBERT SPACES

  • Cho, Seong Ho;Jeong, Jin-Mun;Kang, Yong Han
    • Journal of the Korean Mathematical Society
    • /
    • v.53 no.5
    • /
    • pp.1019-1036
    • /
    • 2016
  • In this paper, we study the existence of solutions and $L^2$-regularity for fractional order retarded neutral functional differential equations in Hilbert spaces. We no longer require the compactness of structural operators to prove the existence of continuous solutions of the non-linear differential system, but instead we investigate the relation between the regularity of solutions of fractional order retarded neutral functional differential systems with unbounded principal operators and that of its corresponding linear system excluded by the nonlinear term. Finally, we give a simple example to which our main result can be applied.

Technique on the speed up of neutral section in the catenary system (절연구분장치의 속도향상 기술)

  • Chang, Sang-Hoon;Park, Byung-Soo;Kim, Young-Gon
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.71-74
    • /
    • 2005
  • At the neutral sections, There are neutral sections inserted in overhead contact line between the substations to divide different phase current sections of AC electrified lines. except convention line, a large stress occurs in the contact wire near the fittings under passing pantographs. So, in order to raise the train speed over 150km/h, a new type section has been adopted.

  • PDF

EXISTENCE OF SOLUTIONS FOR DOUBLE PERTURBED IMPULSIVE NEUTRAL FUNCTIONAL EVOLUTION EQUATIONS

  • Vijayakumar, V.;Sivasankaran, S.;Arjunan, M. Mallika
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.15 no.4
    • /
    • pp.253-265
    • /
    • 2011
  • In this paper, we study the existence of mild solutions for double perturbed impulsive neutral functional evolution equations with infinite delay in Banach spaces. The existence of mild solutions to such equations is obtained by using the theory of the Hausdorff measure of noncompactness and Darbo fixed point theorem, without the compactness assumption on associated evolution system. An example is provided to illustrate the theory.

Existence Results for the Nonlinear First Order Fuzzy Neutral Integrodifferential Equations

  • Radhakrishnan, Bheeman;Nagarajan, Murugesan;Narayanamoorthy, Samayan
    • Kyungpook Mathematical Journal
    • /
    • v.53 no.1
    • /
    • pp.87-98
    • /
    • 2013
  • In this paper, we devoted to study the existence and uniqueness of nonlinear fuzzy neutral integrodifferential equations. Moreover we study the fuzzy solution for the normal, convex, upper semicontinuous, and compactly supported interval fuzzy number. The results are obtained by using the Banach fixed-point theorem. An example is provided to illustrate the theory.

CONTROLLABILITY OF NEUTRAL FUNCTIONAL INTEGRODIFFERENTIAL SYSTEMS IN ABSTRACT SPACE

  • Li, Meili;Duan, Yongrui;Fu, Xianlong;Wang, Miansen
    • Journal of applied mathematics & informatics
    • /
    • v.23 no.1_2
    • /
    • pp.101-112
    • /
    • 2007
  • In this paper, by using fractional power of operators and Sadovskii fixed point theorem, we study the controllability of abstract neutral functional integrodifferential systems with infinite delay. As application, an example is provided to illustrate the obtained results.

Study of neutral beam characteristics using SIMS depth profile and improvement of neutral beam flux (SIMS depth profile을 이용한 중성빔 특성 분석 및 flux 향상방안)

  • Kim, Seong-U;Park, Byeong-Jae;Min, Gyeong-Seok;Gang, Se-Gu;Yeom, Geun-Yeong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2007.04a
    • /
    • pp.61-62
    • /
    • 2007
  • low angle forward reflected neutral beam etching system으로 식각한 후 SIMS depth profile을 이용하여 에너지 침투 깊이에 따른 중성빔 에너지를 분석하여 중성화 과정에서 에너지와 flux의 손실이 있었다. 기존의 two-grid 대신에 three-grid를 사용하여 에너지의 변화없이 이온 flux 및 중성빔 flux가 향상됨을 알 수 있었다.

  • PDF

Technique for the Speed Up of Neutral Section on the Convention Line Catenary System (기존선 교류전기철도 절연구분장치에서의 속도향상 기술)

  • Chang, Sang-Hoon;Lee, Ki-Won
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.294-301
    • /
    • 2008
  • At the neutral sections, There are neutral sections inserted in overhead contact line between the substations to divide different phase current sections of AC electrified lines. Except convention line, a large stress occurs in the contact wire near the fittings under passing pantographs. So, in order to raise the train speed over 150km/h, a new type section has been adopted.

  • PDF

Establishment of Optimum Floor Surface Temperature Floor in Ondol Heating System (온수온돌 난방시 바닥면의 중성온도 설정에 관한 연구)

  • 공성훈
    • Journal of the Korean housing association
    • /
    • v.6 no.2
    • /
    • pp.51-55
    • /
    • 1995
  • This study presents a real neutral floor surface temperature in floor panel heating system(Ondol). The Ondol heating system can keep the constant temperature. However, the actual temperature when a person sits on a floor can be different from the surface temparature of a floor it self. The contents of this study are as follows : 1) measuring the spatial distributions of thermal conditions 2) the thermal sensation vote of residents is taken in order to investigate the relation between thermal condition and human thermal sensation in sedentary condition 3) estimating the neutral floor surface temperatures by measuring floor surface temperatures.

  • PDF