• Title/Summary/Keyword: Neutral Current

검색결과 485건 처리시간 0.025초

초전도체 및 상전도체의 변압기 2차측 적용에 따른 변압기형 SFCL 특성 비교 (Transient Characteristics of a Transformer Type SFCL Applying the Superconductor and the Normal-conductor into the Secondary Winding)

  • 정병익;최효상
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.873-877
    • /
    • 2016
  • This paper proposed the structure that applied superconductors to the neutral line of a transformer and applied the normal conductors to the third line. The superconductor applied to the neutral line of a transformer limited the peak value of initial fault current, while the normal conductor finally limited the fault current. In order to secure the operating reliability of transformer type Superconducting Fault Current Limiter (SFCL) of previously proposed structure, we analyzed the operating characteristics according to the fault types. We tested a line-to-ground fault and a line-to-line fault. As a result of the experiment, all the faults showed that the superconductor stably limited the peak-value of initial fault current. Also, the normal conductor finally limited the fault current. Based on this research results, We thought that if the structure of inserting superconductor into the neutral line is applied to the real system, it could improve the reliability and stability of the power system.

시뮬레이터를 이용한 정지형 개폐기 여자돌입전류 분석 (The Analysis of the Inrush Current of Main Transformer Using the Simulator)

  • 신효범;한문섭;장동욱;창상훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.2005-2010
    • /
    • 2011
  • On AC railway systems, the neutral sections are installed in front of substations and sectioning posts in order to avoid crash between power that have differing phases. In case railway vehicles pass through these neutral sections, it is necessary for them to switch to coasting driving by notch-off. This may reduce speed of the vehicles, resulting lowered train operation efficiency. The usage of automatic power switching systems makes it possible to pass neutral sections at notch-on, enhancing operation efficiency so that it is appropriate for high-speed railway applications. This paper analyzed inrush current of main transformer that installed on the train while passing through the neutral section using the simulator.

  • PDF

NPC 인버터를 위한 새로운 전류제어 기법 (A New Current Controlled PWM technique for NPC Inverter)

  • 이병송;김길동;변윤섭;한영재;박현주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.63-69
    • /
    • 1998
  • A new current controlled PWM technique with NPC structure is proposed in this paper. A current controlled PWM technique with neutral-point-clamped pulse-width modulation inverter composed of main switching devices which operates as switch for PWM and auxiliary switching devices to clamp the output terminal potential to the neutral point potential is described. The proposed current controller has a first and second current band. The switching pattern will be made by the first current band. According to the second current band, the output state of the switching pattern is changed into positive and negative state. This inverter output contains less harmonic content and lower switching frequency than that of conventional current controlled PWM technique at the same current limit. Two inverters are compared analytically and the performance is investigated by the computer simulation.

  • PDF

A Three-Phase Four-Wire DSTATCOM for Power Quality Improvement

  • Singh, Bhim;Jayaprakash, P.;Kothari, D.P.
    • Journal of Power Electronics
    • /
    • 제8권3호
    • /
    • pp.259-267
    • /
    • 2008
  • Power quality improvement in a three-phase four-wire system is achieved using a new topology of DSTATCOM (distribution static compensator) consisting of a star/delta transformer with a tertiary winding and a three-leg VSC (voltage source converter). This new topology of DSTATCOM is proposed for power factor correction or voltage regulation along with harmonic elimination, load balancing and neutral current compensation. A tertiary winding is introduced in each phase for a delta connected secondary in addition to the star-star windings and this delta connected winding is responsible for neutral current compensation. The dynamic performance of the proposed DSTATCOM system is demonstrated using MATLAB with its Simulink and Power System Blockset (PSB) toolboxes under varying loads. The capacitor supported DC bus of the DSTATCOM is regulated to the reference voltage under varying loads.

22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석 (Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line)

  • 김점식;김도영;박용범
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

중성염화물욕에서 아연의 고전류밀도 전착특성 (Electrodeposition behaviors of zinc from neutral chloride baths at high current density)

  • 김영근
    • 한국표면공학회지
    • /
    • 제29권4호
    • /
    • pp.219-228
    • /
    • 1996
  • Neutral Zinc Electroplating(NZE) utilizing the electrolyte of pH 6 to 8 has advantages in waste treatment and the protection of equipment. NZE is beneficially used in chromating treatment, but the limiting current density and the current efficiency are low. Therefore this study is investigated to analyse the characteristics of NZE and to obtain high current density and current efficiency. The deposition potential of zinc in the NZE bath is about 110mV, which is lower than acidic bath. The current density possibily increases up to 60A/d$\m^2$ in lower complexing agent content and pH 6. More than 90% of cathodic current efficiency was obtained in NZE bath. The NZE morphology shows smaller grains than acidic bath. The addition of 4$m\ell$/1 second brightener gives finer morphology. As pH becomes higher, (002) plan decreases and (100), (101) and (110) planes increase in the no additives solution.

  • PDF

3상 3-레벨 컨버터의 누설전류 저감과 NP 전류 제어를 위한 캐리어 기반 LFCPWM (Carrier Based LFCPWM for Leakage Current Reduction and NP Current Control in 3-Phase 3-Level Converter)

  • 이은철;최남섭
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.446-454
    • /
    • 2022
  • This study proposes a carrier-based pulse width modulation (PWM) method for leakage current reduction and neutral point (NP) current control in a three-phase three-level converter, which is a carrier-based PWM version of the previously proposed low-frequency common mode voltage PWM. Three groups of space vectors with the same common mode voltage are used. When the averaged NP current needs to be positive or negative, the specific groups are employed to produce low-frequency common mode voltages. The validity of the proposed PWM method is verified through experiments.

Zig-Zag 결선 및 Open-Delta 방식을 이용한 새로운 고조파 저감장치의 개발 (Development of the New Hormonic Eliminating Device Using Zig-Zag Connection and Open-Delta Mode)

  • 이성호;김기성;유상봉
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.169-174
    • /
    • 2005
  • 지금까지의 고조파 필터는 중성선 리액터와 지그재그결선의 영상 고조파 전류를 제거하였으나, 부하율에 따라 고조파 저감율이 변하여 경부하에서는 고조파 저감율이 낮아지는 특성이 있고, 중성선 리액터 과열로 중성선 단선 위험의 문제가 발생하였다. 본 Zig-Zag 결선 및 Open Delta 방식을 이용한 새로운 고조파 저감장치(HANOS)는 Zig-Zag 결선의 Core Block내에 추가로 Open Delta 방식을 결선하여 중성선에 연결함으로써 중성선에 흐르는 영상 고조파 전류가 과열 없이 안전하게 제거되는 것을 시험 분석한 결과로 증명하였다.

접지 임피던스가 중성선 고조파 전류에 미치는 영향 (The Ground Impedance Influence on Neutral Harmonic Currents)

  • 김경철;백승현;이일무;김종욱
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.120-127
    • /
    • 2004
  • 스위칭 모드 전원 공급 장치와 같은 비선형 부하의 증가로, 3상 4선식 배전계통을 채용하는 중성선에 많은 고조파 전류가 흐른다. 중성선은 접지 시스템과 연결되어 있기 때문에 접지 임피던스는 중성선 고조파 전류에 영향을 끼친다고 알려져 있다. 현장에서 실측한 고조파 전류와 전압으로 고조파 해석용 3상 등가 회로를 구성하였다. 실측한 값과 MATLAB으로 시뮬레이션 한 값을 수치와 파형으로 비교 검토하였다. 또한 본 논문에서는 중성선 고조파 전류와 접지 임피던스와의 관계를 시뮬레이션을 통해 검증하였다.

배전선로에서의 비선형부하에 따른 중성선 고조파 분석 (Analysis of Neutral Harmonic Currents according to Non-linear Loads in Distribution Lines)

  • 왕태희;김현수;이상봉;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.183-184
    • /
    • 2008
  • In this paper, the THD(Total Harmonic Distortion) in distribution systems according to the ratio of non-linear loads was calculated and analyzed. The PCC(Point of Common Coupling) is selected to analyze THD of a 3-phase current and a neutral current.

  • PDF