DC-Link Voltage Balance Control Using Fourth-Phase for 3-Phase 3-Level NPC PWM Converters with Common-Mode Voltage Reduction Technique

  • Jung, Jun-Hyung;Park, Jung-Hoon;Kim, Jang-Mok;Son, Yung-Deug
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.108-118
    • /
    • 2019
  • This paper proposes a DC-link voltage balance controller using the fourth-phase of a three-level neutral-point clamped (NPC) PWM converter with medium vector selection (MVS) PWM for common-mode voltage reduction. MVS PWM makes the voltage reference by synthesizing the voltage vectors that cannot generate common-mode voltage. This PWM method is effective for reducing the EMI noise emitted from converter systems. However, the DC-link voltage imbalance problem is caused by the use of limited voltage vectors. Therefore, in this paper, the effect of MVS PWM on the DC-link voltage of a three-level NPC converter is analyzed. Then a proportional-derivative (PD) controller for the DC-link voltage balance is designed from the DC-link modeling. In addition, feedforward compensation of the neutral point current is included in the proposed PD controller. The effectiveness of the proposed controller is verified by experimental results.

Consumers' Attitudes toward the General and Fashion-Specific Climate Environments: Focusing on the Relations with Values, Knowledge, and Climate Cognition (소비자들의 일반기후환경태도와 패션기후환경태도: 가치와 지식 및 기후인식과의 관계를 중심으로)

  • Ihn Hee Chung
    • Human Ecology Research
    • /
    • v.61 no.4
    • /
    • pp.599-613
    • /
    • 2023
  • This study investigated female consumers' attitudes toward the general and fashion-specific climate environments and analyzed the relations between the attitudes and the variables such as values, knowledge, and climate cognition. The data was collected from a sample of 450 women in their 20s, 30s, and 40s via quota sampling from a selfreported online survey in 2023. The measurement comprised the attitudes toward the general and fashion-specific climate environments, Rokeach's 18 terminal values, Holbrook's 8 consumer values regarding fashion products, climate environmental knowledge related to fashion, the cognition concerning the climate crisis, and several demographic variables. Descriptive statistics, factor analysis, reliability analysis, and correlations were applied to the data using SPSS. As a result, two factors were determined for the attitudes toward the general and fashion-specific climate environments, respectively: social and personal. Family security, happiness, and self-respect were identified as important terminal values. Quality, efficiency, aesthetics, and ethics were considered important when the current sample group purchased fashion products. The mean score of climate environmental knowledge related to fashion was lower than neutral; however the cognition of the climate crisis was considerably high. Attitudes toward the general and fashion-specific climate environments showed positive relations with values, knowledge, and climate cognition. The results were discussed to provide some insight and suggestions to carbon neutrality and the related studies.

Battery Energy Storage System Based Controller for a Wind Turbine Driven Isolated Asynchronous Generator

  • Singh, Bhim;Kasal, Gaurav Kumar
    • Journal of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.81-90
    • /
    • 2008
  • This paper presents an investigation of a voltage and frequency controller for an isolated asynchronous generator (IAG) driven. by a wind turbine and supplying 3-phase 4-wire loads to the isolated areas where a grid is not accessible. The control strategy is based on the indirect current control of the VSC (voltage source converter) using the frequency PI controller. The proposed controller consists of three single-phase IGBT (Insulated Gate Bipolar Junction Transistor) based VSC, which are connected to each phase of the IAG through three single phase transformers and a battery at their DC link. The controller has the capability of controlling reactive and active powers to regulate the magnitude and frequency of the generated voltage, harmonic elimination, load balancing and neutral current compensation. The proposed isolated system is modeled and simulated in MATLAB using Simulink and PSB (Power System Block-set) toolboxes to verify the performance of the controller.

Transformer-Less Single-Phase Four-Level Inverter for PV System Applications

  • Yousofi-Darmian, Saeed;Barakati, Seyed Masoud
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1233-1242
    • /
    • 2014
  • A new inverter topology for single-phase photovoltaic (PV) systems is proposed in this study. The proposed inverter offers a four-level voltage in its output terminals. This feature results in easier filtering in comparison with other conventional two-level or three-level inverters. In addition, the proposed four-level inverter (PFLI) has a transformer-less topology, which decreases the size, weight, and cost of the entire system and increases the overall efficiency of the system. Although the inverter is transformer-less, it produces a negligible leakage ground current (LGC), which makes this inverter suitable for PV grid-connected applications. The performance of the proposed inverter is compared with that of a four-level neutral point clamped inverter (FLNPCI). Theoretical analysis and computer simulations verify that the PFLI topology is superior to FLNPCI in terms of efficiency and suitability for use in PV transformer-less systems.

Tolerance Control for the Inner Open-Switch Faults of a T-Type Three-Level Rectifier

  • Lee, June-Seok;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1157-1165
    • /
    • 2014
  • The T-type topology is a three-level topology that has an advantage in terms of its number of switching device and its efficiency when compared to the neutral-point clamped (NPC)-type topology. With the recent increase in the usage of the T-type topology, the interest in its reliability has also increased. Therefore, a tolerance control for a T-type rectifier is necessary to improve the reliability of applications when an open-switch fault occurs. NPC-type rectifiers cannot eliminate input current distortion completely. However, the T-type rectifier is able to restore distorted current. In this paper, a tolerance control for the $S_{x2}$ and $S_{x3}$ open-switch faults of a T-type rectifier is proposed where it is advantageous in terms of efficiency when compared with other tolerance controls. The performance of the proposed tolerance control is verified through simulation and experimental results.

A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner

  • Singh, Bhim;Venkateswarlu, P.
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a simplified control algorithm for a three-phase, four-wire unified power quality conditioner (UPQC) is presented to compensate for supply voltage distortions/unbalance, supply current harmonics, the supply neutral current, the reactive power and the load unbalance as well as to maintain zero voltage regulation (ZVR) at the point of common coupling (PCC). The UPQC is realized by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The shunt AF is realized using a three-phase, four leg voltage source inverter (VSI) and the series AF is realized using a three-phase, three leg VSI. A dynamic model of the UPQC is developed in the MATLAB/SIMULINK environment and the simulation results demonstrating the power quality improvement in the system are presented for different supply and load conditions.

Ductility enhancement of reinforced concrete thin walls

  • Kim, Jang Hoon
    • Computers and Concrete
    • /
    • v.2 no.2
    • /
    • pp.111-123
    • /
    • 2005
  • The ductility of reinforced concrete bearing walls subjected to high axial loading and moment can be enhanced by improving the deformability of the compression zone or by reducing the neutral axis depth. The current state-of-the-art procedure evaluating the confinement effect prompts a consideration of the spaces between the transverse and longitudinal reinforcing bars, and a provision of tie bars. At the same time, consideration must also be given to the thickness of the walls. However, such considerations indicate that the confinement effect cannot be expected with the current practice of detailing wall ends in Korea. As an alternative, a comprehensive method for dimensioning boundary elements is proposed so that the entire section of a boundary element can stay within the compression zone when the full flexural strength of the wall is developed. In this comprehensive method, the once predominant code approach for determining the compression zone has been advanced by considering the rectangular stress block parameters varying with the extreme compression fiber strain. Moreover, the size of boundary elements can also be determined in relation to the architectural requirement.

Study on the Measurement of Radiation Energy of the Arc in GCBs (가스차단기내 아크의 복사에너지 측정에 관한 연구)

  • Song, Ki-Dong;Oh, Yeon-Ho;Chong, Jin-Kyo;Cho, Young-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2122-2126
    • /
    • 2007
  • A special PM-Tube(Photo Multiplier Tube) that is using the photoelectric effect has been designed and manufactured to measure the radiation energy of arc in a gas circuit breaker(GCB). The PM-Tube, LLG(liquid light guides), ND(neutral density) filter, and a model gas circuit breaker have been combined for the reception and the transmission of the light and a simplified synthetic test facility with the arc energy measuring system has been established. In the case of $SF_6$ gas pressure $5kg.f/cm^2$ and arc length 20mm, the radiation energy increases with the arc current but it tend to be saturated in the above 20kA. Under the arc current 20kA, the total radiation energy has the biggest value around 8kA and was not exceeded 40% of the total arc energy.

Vibration Isolation System for Driver's Seats with Negative Stiffness (운전자용 의자의 부강성 진동 절연 시스템)

  • Park, Sung-Tae;Lee, Sang-Joo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.2
    • /
    • pp.114-121
    • /
    • 2010
  • As a vehicle speed increases, more vibration energy is transmitted from chassis to a driver. Current isolation system for the driver's seat by damping control can reduce the transmitted vibration energy near resonance area. But in higher frequency region than natural frequency multiplied by $\sqrt{2}$, the vibration energy transmitted to the driver has a tendency to be increased. Therefore, the method by natural frequency reduction of the system is preferred to increase the effectiveness of the anti-vibration. However, the natural frequency could not be freely reduced due to the nature of the isolation system structure. A new passive suspension system to reduce the natural frequency is proposed. The theoretical analysis and experimental results show better vibration attenuation compared with the current isolation system.

High Impedance Fault Detection on 22.9kV Multigrounded Distribution System (22.9kV 이중접지 배전선로 고저항 지락 검출)

  • Park, Young-Moon;Lee, Ki-Won;Lim, Ju-Il;Yoon, Man-Chul;Yoo, Myeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.463-468
    • /
    • 1987
  • In this paper, a high impedance fault detection on 22.9kV multigrounded distribution system that has been very difficult by any existing conventional protective relaying systems is studied. Because the fault current is very low, it cannot be distinguished from neutral current caused by load unvalanced on multigrounded distribution system. We developed the new and best algorithms of high impedance ground fault detection. This algorithms are 'the even order power method, even order ratio method', 'and even order ratio varience method'. Using this algorithms, a detection device for high impedance faults is constructed and tested in the laboratory. And continually, it is installed and has been tested in KEPCO substations.

  • PDF