• Title/Summary/Keyword: Neutral Current

Search Result 486, Processing Time 0.028 seconds

Analysis on Current and Optical Characteristics by Electronic Ink Loading Method in Charged Particles Type Display (대전입자형 디스플레이에서 전자 잉크 주입 방법에 따른 전류 및 광특성 분석)

  • An, Hyeong-Jin;Kim, Young-cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.2
    • /
    • pp.123-129
    • /
    • 2020
  • We analyzed the drift current by charged particles according to the loading methods applied into a closed cell by electronic ink at a reflective-type display panel using an electrophoretic mechanism. For this experiment, various panels were fabricated with injection voltages for electronic ink taking values in the range -4~0 V. The size of each cell was 220 ㎛ × 220 ㎛ and height of the barrier rib was 54.28 ㎛. The electronic ink was fabricated by mixing electrically neutral fluid and single-charge white particles. Drift current was measured by moving charged particles. A biasing voltage of 6 V was applied to the display panel. As a result, the drift current was proportional to the injection voltage for electronic ink, but it decreased in case of an injection voltage above -3 V. Our experimentation ascertained that the concentration of charged particles injected into closed cells is controlled by the injection voltage and the selective injection of charged particles above movable q/m is possible.

Assessment of kinetics behavior of electrocoagulation process for the removal of suspended solids and metals from synthetic water

  • Singh, Hariraj;Mishra, Brijesh Kumar
    • Environmental Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.141-148
    • /
    • 2017
  • Globalization, industrialization, mining, and uncontrolled population growth have fostered a shortage of potable water. Therefore, it has become imperative to understand an effective and reasonable water purification technique. A renewed interest in electrocoagulation (EC) has been spurred by the search for reliable, cost-effective, water-treatment processes. This paper has elucidated a technical approach for getting rid of heavy metals and total suspended solids (TSS) from synthetic water using an aluminum electrode. The effect of operational parameters, such as current density, inter-electrode distance, operating time, and pH, were studied and evaluated for maximum efficiency. This study corroborates the correlation between current density and removal efficiency. Neutral pH and a low electrode gap have been found to aid the efficacy of the EC setup. The outcome indicates that a maximum TSS removal efficiency of 76.6% occurred at a current density of $5.3mA/cm^2$ during a contact time of 30 min. In the case of heavy metals remediation, 40 min of process time exhibited extremely reduced rates of 99%, 59.2%, and 82.1%, for Cu, Cr, and Zn, respectively. Moreover, kinetic study has also demonstrated that pollutants removal follows first-and second-order model with current density and EC time being dependent.

Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems (측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정)

  • Lee, Bok-Hui;Eom, Ju-Hong;Kim, Seong-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

Rapid Electric Vehicle Charging System with Enhanced V2G Performance

  • Kang, Taewon;Kim, Changwoo;Suh, Yongsug;Park, Hyeoncheol;Kang, Byungik;Kim, Simon
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.201-202
    • /
    • 2012
  • This paper presents a simple and cost-effective stand-alone rapid battery charging system of 30kW for electric vehicles. The proposed system mainly consists of active front-end rectifier of neutral point clamped 3-level type and non-isolated bi-directional dc-dc converter of multi-phase interleaved half-bridge topology. The charging system is designed to operate for both lithium-polymer and lithium-ion batteries. The complete charging sequence is made up of three sub-interval operating modes; pre-charging mode, constant-current mode, and constant-voltage mode. Each mode is operated according to battery states: voltage, current and State of Charging (SOC). The proposed system is able to reach the full-charge state within less than 16min for the battery capacity of 8kWh by supplying the charging current of 67A. The optimal discharging algorithm for Vehicle to the Grid (V2G) operation has been adopted to maintain the discharging current of 1C. Owing to the simple and compact power conversion scheme, the proposed solution has superior module-friendly mechanical structure which is absolutely required to realize flexible power expansion capability in a very high-current rapid charging system. Experiment waveforms confirm the proposed functionality of the charging system.

  • PDF

A Study on the Over Current Relay Misoperation in Power System with Distributed Generations (분산전원 연계 계통에서의 과전류계전기 오동작에 관한 연구)

  • Park, Jong-Il;Lee, Kyebyung;Park, Chang-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1705-1710
    • /
    • 2018
  • This paper deals with an analysis of the causes of over current relay(OCR) misoperation in power system with distributed generations(DG). In general, Y-D and Y-Y-D transformer connections are used for grid interconnection of DG. According to the interconnection guideline, the neutral point on Y side should be grounded. However, these transformer connections can lead to OCR misoperation as well as over current ground relay(OCGR) misoperation. Several researches have addressed the OCGR misoperation due to the interaction between transformer connections and zero-sequence voltage of distribution system. Recently, a misoperation of OCR at the point of DG interconnection to the utility system has been also reported. With increasing the interconnections of DG, such OCR as well as OCGR misoperations are expected to increase. In this paper, PSCAD/EMTDC modeling including DG interconnection transformer was performed and various case studies was carried out for identifying the cause of OCR misoperation.

A Newly Developed Non-Cyanide Electroless Gold Plating Method Using Thiomalic Acid as a Complexing Agent and 2-Aminoethanethiol as a Reducing Agent

  • Han, Jae-Ho;Lee, Jae-Bong;Van Phuong, Nguyen;Kim, Dong-Hyun
    • Corrosion Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.89-99
    • /
    • 2022
  • A versatile method for performing non-cyanide electroless gold plating using thiomalic acid (TMA) as a complexing agent and 2-aminoethanethiol (AET) as a reducing agent was investigated. It was found that TMA was an excellent complexing agent for gold. It can be used in electroless gold plating baths at a neutral pH with a high solution stability, makes it a potential candidate to replace conventional toxic cyanide complex. It was found that one gold atomic ion could bind to two TMA molecules to form the [2TMA-Au+] complex in a solution. AET can be used as a reducing agent in electroless gold plating solutions. The highest current density was obtained at electrode rotation rate of 250 to 500 rpm based on anodic and cathodic polarization curves with the mixed potential theory. Increasing AET concentration, pH, and temperature significantly increased the anodic polarization current density and shifted the plating potential toward a more negative value. The optimal gold ion concentration to obtain the highest current density was 0.01 M. The cathodic current was higher at a lower pH and a higher temperature. The current density was inversely proportional to TMA concentration.

Study on the analysis of impulse test wave in the short coil (layer)of transformer winding (변압기 권선(층간)단락시의 충격파시험파형분석에 관한 연구)

  • 박민호
    • 전기의세계
    • /
    • v.25 no.5
    • /
    • pp.75-78
    • /
    • 1976
  • The most difficult problem encountered in impulse test of transformer is the determination of exact fauly for coil layer short. This paper is to establish one of improved standards in the above case by means of wave form analysis, based on the equivalent circuits and experimental investigation. During the fault occurs, the local oscillation in fault circuit is applicable where as the reflection wave is utilized to the main circuit. The result current wave form at neutral impeadance point is similar to the wave form by impulse test and has the singular wave form respectively.

  • PDF

Classification of High Impedance Fault Patterns by Recognition of Linear Prediction coefficients (선형 예측 계수의 인식에 의한 고저항 지락사고 유형의 분류)

  • Lee, Ho-Seob;Kong, Seong-Gon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1353-1355
    • /
    • 1996
  • This paper presents classification of high impedance fault pattern using linear prediction coefficients. A feature of neutral phase current is extracted by the linear predictive coding. This feature is classified into faults by a multilayer perceptron neural network. Neural network successfully classifies test data into three faults and one normal state.

  • PDF

Development of Korean Social Affective Visual Stimuli (한국형 사회적 정서 유발 시각 자극 개발)

  • Seok, Bum Joon;Kim, Nambeom;Min, Kyung Ha;Park, Dohyun;Kim, Seog Ju
    • Sleep Medicine and Psychophysiology
    • /
    • v.25 no.1
    • /
    • pp.21-26
    • /
    • 2018
  • Objectives: The current study aims to develop Korean Social Affective Visual Stimuli (K-SAVS) to arouse social affect. Methods: K-SAVS is composed of pictures of social situations among East Asians. Each picture contains a negative, positive, or neutral affect. Positive and negative stimuli were presented to one group of subjects. Negative and neutral stimuli were presented to another group of subjects. All subjects were required to fill out Affective Valence and Arousal Manikin. Results: In the initial test, 18 positive affective stimuli pictures (1 set) and 36 negative affective stimuli pictures (2 sets) were chosen from 95 stimuli pictures. Positive affective stimuli pictures showed higher valence (p < 0.001) and lower arousal (p < 0.001) than negative affective stimuli pictures. In the confirmatory test, 18 neutral stimuli pictures (1 set) were additionally selected out of the total of 79 pictures of neutral stimuli pictures and the pictures used in the former experiment. Neutral stimuli pictures showed higher valence (p < 0.001) and lower arousal (p < 0.001) than negative affective stimuli pictures. Conclusion: K-SAVS can be a valid and useful tool for inducing specific social affects of Koreans.

Performance of Beam Extractions for the KSTAR Neutral Beam Injector

  • Chang, D.H.;Jeong, S.H.;Kim, T.S.;Lee, K.W.;In, S.R.;Jin, J.T.;Chang, D.S.;Oh, B.H.;Bae, Y.S.;Kim, J.S.;Cho, W.;Park, H.T.;Park, Y.M.;Yang, H.L.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.240-240
    • /
    • 2011
  • The first neutral beam injector (NBI-1) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) tokamak. A first long pulse ion source (LPIS-1) has been installed on the NBI-1 for an auxiliary heating and current drive of KSTAR core plasmas. Performance of ion and neutral beam extractions in the LPIS-1 was investigated initially on the KSTAR NBI-1 system, prior to the neutral beam injection into the main plasmas. The ion source consists of a JAEA magnetic bucket plasma generator with multi-pole cusp fields and a set of KAERI prototype-III tetrode accelerators with circular apertures. The inner volume of plasma generator and accelerator column in the LPIS-1 is approximately 123 liters. Final design requirements for the ion source were a 120 kV/ 65 A deuterium beam and a 300 s pulse length. The extraction of ion beams was initiated by the formation of arc plasmas in the LPIS-1, called as an arc-beam extraction method. A stable ion beam extraction of LPIS-1 has been achieved up to an 100 kV/42 A for a 4 s pulse length and an 80 kV/25 A for a 14 s pulse length. Optimum beam perveance of 1.21 microperv has been found at an accelerating voltage of 80 kV. Neutralization efficiency has been measured by using a water flow calorimetry (WFC) method of calorimeter and an operation of bending magnet. The full-energy species of ion beams have been detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6~1.1 A/kW depending on the operating conditions of arc discharge.

  • PDF