• Title/Summary/Keyword: Nerve stimulator

Search Result 55, Processing Time 0.023 seconds

Cervical and Thoracic Spinal Cord Stimulation in a Patient with Pediatric Complex Regional Pain Syndrome -A case report- (소아 복합부위통증증후군 환자에서 경부와 흉부 척수 자극술 -증례보고-)

  • Park, Jung Ju;Moon, Dong Eon;Park, Seung Jae;Choi, Jung Il;Shim, Jae Chol
    • The Korean Journal of Pain
    • /
    • v.20 no.1
    • /
    • pp.60-65
    • /
    • 2007
  • Complex Regional Pain Syndromes (CRPS) type I and type II are neuropathic pain conditions that are being increasingly recognized in children and adolescents. The special distinctive features of pediatric CRPS are the milder course, the better response to treatment and the higher recurrence rate than that of adults and the lower extremity is commonly affected. We report here on a case of pediatric CRPS that was derived from ankle trauma and long term splint application at the left ankle. The final diagnoses were CRPS type I in the right upper limb, CRPS type II in the left lower limb and unclassified neuropathy in the head, neck and precordium. The results of various treatments such as medication, physical therapy and nerve blocks, including lumbar sympathetic ganglion blocks, were not effective, so implantation of a spinal cord stimulator was performed. In order to control the pain in his left lower limb, one electrode tip was located at the 7th thoracic vertebral level and two electrode tips were located at the 7th and 2nd cervical vertebral levels for pain control in right upper limb, head, neck and right precordium. After the permanent insertion of the stimulator, the patient's pain was significantly resolved and his disabilities were restored without recurrence. The patient's pain worsened irregularly, which might have been caused by psychological stress. But the patient has been treated with medicine at our pain clinic and he is being followed up by a psychiatrist. (Korean J Pain 2007; 20: 60-65)

Effect of EGS on the Patients with TMJ Pain (EGS가 악관절동통 환자에 미치는 영향)

  • 김영구
    • Journal of Oral Medicine and Pain
    • /
    • v.9 no.1
    • /
    • pp.23-28
    • /
    • 1984
  • Author could get the result as below after EGS(an electrical nerve stimulator) treatment, one of the pain-reliaving methods, to 30 patients in whom author could confirm the objective improvement of symptoms among the patients who visited SNUH between July the first and December the 31th. 1984. because of TMJ pain. 1. The average number of treatment were 5.5 times/pt., and mean treatment duration was 20 minutes. 2. The severities of pain before the treatment were distressing (46.7%), discomforting (26.7%), mild (20.0%) and horrible (6.7%), but the percentages of them became changed to mild (50%), discomforting (33.3%), none (10%) and distressing (6.7%) after treatment. 3. The activities of mouth opening before the treatment were moderately restricted (53.3 %), serverely restricted (33.3%) and slightly restricted (13.3%), but the percentages of them became changed to slightly restricted (66.7%), normal (16.7%), modorately restricted (13.3%) and severely restricted (3.3%) after treatment. 4. The effects of the pain upon one's personality before treatment were severely upset (43.3%), moderately upset (36.7%), slightly upset(16.7%) and normal (3.3%), but the percentages of them became changed to slightly upset (50%), normal (33.3%), morderately upset (10%) and severely upset (6.7%) after treatment.

  • PDF

Skeletal Muscle Ventricle Mechanics (골격근 심실의 역학)

  • 오중환
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.428-432
    • /
    • 1999
  • Background: It has been shown that low-grade electrical stimulus can transform fatigue resistant muscles which then can be used to protect the heart. The bulky and cumbersome power sources of the artificial heart or implantable ventricular assist devices are still in need of solution; however, on the other hand, the implantable ventricular assist devices using the resistant muscles as the power source have the advantages of using its own muscle contractions. The purpose of this study was to determine the possibility of a clinical application of the skeletal muscle ventricle. Material and Method: Latissimus dorsi muscles (LDM) of 8 canines were used for skeletal muscle ventricle. A latex chamber was wrapped one and a half times with LDM. The chamber was attached to a pressure transducer via Tygon tube. An electrode stimulator was placed around the thoracodorsal nerve and LDM was stimulated in cyclic bursts of 0.31 sec on time and 6.0 sec off time using 3.0 volt Itrel stimulator. The preload volume was added to the system in 25cc increments. Ejection volumes, pressures, and peak power outputs were measured. Result: Ejection volume was 76.3cc with 0cc of preload. Ejection volumes were less than 70ml with increments of preload over 75cc Pressures were more than 107 mmHg when the preloads were less than 75cc and less than 100 mmHg when the preloads were more than 100cc. Peak power output of 16.6 W/kg was observed at 50cc preload. Conclusion: Depending on the changes of preload, the volumes ejected from skeletal muscle ventricle and pressures from the skeletal muscle contraction surpassed those of the normal heart. These data suggest that there are clinical applications for skeletal muscle ventricular assist system.

  • PDF

Development of Wireless Neuro-Modulation System for Stroke Recovery Using ZigBee Technology (ZigBee를 이용한 뇌졸중 치료용 무선 전기 자극기 개발)

  • Kim, G.H.;Ryu, M.H.;Shin, Y.I.;Kim, H.I.;Kim, N.G.;Yang, Y.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.153-161
    • /
    • 2007
  • Stroke is the second most significant disease leading to death in Korea. The conventional therapeutic approach is mainly based on physical training, however, it usually provides the limited degree of recovery of the normal brain function. The electric stimulation therapy is a novel and candidate approach with high potential for stroke recovery. The feasibility was validated by preliminary rat experiments in which the motor function was recovered up to 80% of the normal performance level. It is thought to improve the neural plasticity of the nerve tissues around the diseased area in the stroked brain. However, there are not so much research achievements in the electric stimulation for stroke recovery as for the Parkinson's disease or Epilepsy. This study aims at the developments of a wireless variable pulse generator using ZigBee communication for future implantation into human brain. ZigBee is widely used in wireless personal area network (WPAN) and home network applications due to its low power consumption and simplicity. The developed wireless pulse generator controlled by ZigBee can generate various electric stimulations without any distortion. The electric stimulation includes monophasic and biphasic pulse with the variation of shape parameters, which can affect the level of recovery. The developed system can be used for the telerehabilitation of stroke patient by remote control of brain stimulation via ZigBee and internet. Furthermore, the ZigBee connection used in this study provides the potential neural signal transmission method for the Brain-Machine Interface (BMI).

Posterior Vertical Approach for Sacrococcygeal Teratomas in Children (소아의 천미추부 기형종 수술시 후방종단식 술식의 이용)

  • Lee, Myung-Duk
    • Advances in pediatric surgery
    • /
    • v.2 no.2
    • /
    • pp.102-109
    • /
    • 1996
  • Pediatric surgeons are familiar with the posterior sagittal approach to the rectum at sacrococcygeal area and well oriented with the anatomy because of the Penal procedure for imperforate anus. The author utilized the posterior vertical elliptical incisions in 12 cases of sacrococcygeal teratoma since 1987. For presacral tumor(type IV)$^2$, the incision was exactly same as the posterior sagittal procedure for imperforate anus. But the out-growing(type I) or dumbbell-shaped(type II & III) tumors, a vertical elliptical incision was required. For the laterally deviated tumors, a vertical and half-chevron incision was utilized in one case, but an unbalanced vertical elliptical incision was acceptable for the remaining two cases, with shrinkage of the overlying skin. In dumbbell-shaped tumors(type II & III), the narrow waist of the tumor was at the level of the levator muscle, which formed a muscle-belt on the tumor waist. A careful dissection to save the muscle-belt seemed to be the most important point during this procedure, utilizing the nerve-stimulator. After complete removal of the tumor and the coccyx, the levator muscles and the skin were closed in vertical fashion along the midline. For the caudally extending tumors in 3 cases, the muscle complex was divided in midline. Nothing by mouth and total parenteral nutrition was maintained for 1 week and then laxatives were given for 2 weeks in order to give the sphincters rest. Operative scars were acceptable resembling natural vertical midline folds, and the sphincter function was continent in all cases. In conclusion, vertical elliptical incision in sacrococcygeal teratoma is recommended because of the acceptable scar, functional restoration, and because it is a familiar procedure particularly for the pediatric surgeons who are accustomed performing posterior sagittal approach for imperforate anus.

  • PDF

Development of an Electric Pulp Tester with Constant Current Source (정 전류원을 이용한 치수 검사기의 개발)

  • 김재성;남기창;김수찬;이승종;김덕원
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.2
    • /
    • pp.61-68
    • /
    • 2004
  • Electric stimulation of teeth has been used for assessing pulp vitality. The principle is based upon the assumption that a subject feels the pain produced by electrical current stimulation of intradental nerve. Because of very high and wide range of impedance of the enamel, it is very difficult to determine stimulation levels regardless of teeth status. Most pulp testers adopt voltage stimulation method and thus, their stimulating threshold levels significantly depend on each individual. Therefore, a constant current stimulator is necessary to minimize the effect of wide variation due to different enamel thickness. And it is also necessary to test teeth vitality with a wide current range regardless of tooth impedance. In this study, we constructed a burst-wave type pulp tester to reduce the pain using a current stabilizing circuit with the maximum current of 150 uA.

The Effects of Visual and Auditory Feedback on Pain Reduce (시각과 청각되먹임이 통증감소에 미치는 영향)

  • Bae, Young-Sook;Kim, Soon-Hoe;Min, Kyung-Ok
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.1
    • /
    • pp.1-8
    • /
    • 2002
  • This study set out to investigate what kind of effects the consistent visual stimuli and verbal and non verbal auditory stimuli have on pain alleviation, as well as to see the influence of joint application of visual and auditory stimuli at the same time on pain alleviation, according to lightness of 50lux and 200lux, ultimately providing basic data in setting up an environment in case of treating pain. The subject were comprised of 30 male and female adults with pain in the neck and back area. The subject were treated in their pain area with Transcutaneous Electrical Nerve Stimulator(TENS) 100HZ for 20 minutes in the research set where each visual, auditory, and joint visual and auditory stimuli was given. For analysis methods, Visual Analogue Scale(VAS) and McGill Pain Questionnaire were adopted to see the changes before and after treatment, and the electrocardiogram, systolic and diastolic pressure, number of heart rate and breathing frequence and endorphin were compared and analyzed using the Wilcoxon singed-rank test. And The Kreskal-walllis test was used to compare the two subgroups from each group. Wilcoxon singed-rank test and the Kreskal-walllis test was used to compare the two subgroups from each group. The results were as follows: 1. The group of 50lux and 200lux were compared given varying degrees of visual stimuli. The group of 200lux showed more reduction in pain points, average systolic and diastolic pressure and average endorphin. 2. The group of verbal and non verbal were compared given varying degrees of auditory stimuli. The group of non-verbal showed more reduction in average systolic and diastolic pressure. 3. The group of 200lux+verbal and 200lux+non verbal were compared given varying degrees of joint visual and auditory stimuli. There was found a statistical significance(p<0.05) in endorphin between the two groups, with more endorphin reduction for 200lux+non verbal group. And there was a statistically significant reduction in VAS and McGill before and after the treatment between the two groups.

  • PDF

The Analgesic Effects of Transcutaneous Electrical Nerve Stimulation and Interferential Currents on the Experimental Ischemic Pain Model: Frequency 50 Hz (실험적 허혈 통증 모델에서 경피신경전기자극과 간섭파전류의 진통 효과 비교 : 주파수 50 Hz를 중심으로)

  • Bae, Young-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2617-2624
    • /
    • 2012
  • Interferential currents (IFC) and transcutaneous electrical nerve stimulation (TENS) are used for pain management. This study compared the analgesic effects of IFC and TENS on experimentally induced ischemic pain in otherwise pain-free subjects using a modified version of the submaximal-effort tourniquet technique. The subjects were 14 volunteers (7 male, 7 female) without known pathology that could cause pain. Their mean age was $26.7{\pm}2.0$ years. A single-blind, sham controlled, parallel-group method was used. The primary outcome measure was the change in the self-report of pain intensity during 1 of 3 possible interventions: (1) IFC, (2) TENS, or (3) sham electrotherapy. The IFC and TENS were administered on the forearm, and the sham electrotherapy group received no current output via a dummy stimulator. The results show that a 2-way repeated-measures analysis of variance revealed that there was no change in pain intensity during treatment when all 3 groups were considered together. The mean to pain intensity with the IFC intervention was no different than with TENS. Thus, Statistical analysis showed that both interventions decreased the pain intensity ratings significantly and the difference between interventions was not simply insignificant. IFC has been shown to be more comfortable than TENS in present studies and is likely to be better accepted and tolerated by patients, clinical investigation is warranted.

Blood Flow Changes in the Masseter Muscle and Overlying Skin Following Various Functional Waves of Transcutaneous Electrical Nerve Stimulation (경피신경자극치료기(TENS)의 기능별 주파수에 따른 교근과 피개상피의 혈류변화에 관한 연구)

  • Cho, Sung-Guk;Auh, Q-Schick;Chun, Yang-Hyun;Hong, Jung-Pyo
    • Journal of Oral Medicine and Pain
    • /
    • v.34 no.1
    • /
    • pp.115-122
    • /
    • 2009
  • The following results were obtained, after experimenting on change of masseter muscle and bloodstream epithelium with Transcutaneous Electrical Nerve Stimulator(TENS), among 16 male adults. 1. According to applying TENS, it was observed that bloodstream in muscle increases at 1.5, 3.0 Hz. 2. According to applying TENS, it was observed that concentration of moving blood cells in muscle increase at 1.5, 3.0, 6.0 Hz. 3. According to applying TENS, it was observed that velocity of bloodstream in muscle increases only at 1.5 Hz 4. Through experiment, applying TENS at level of 6.0 and 10.0 Hz, all bloodstream, concentration of moving blood cells, and velocity of bloodstream increasing rates were lower in muscle compared to of them in overlying epithelium; and especially increasing bloodstream and its velocity were most frequent at 6.0 Hz, and bloodstream of 10.0 Hz. From the results above when a physical therapy of TENS is carried out the frequency of 1.5, 3.0 H is effective, and as the frequency increases it is disadvantageous to the muscle.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF