• 제목/요약/키워드: Negative voltage

검색결과 941건 처리시간 0.027초

NCFET (negative capacitance FET)에서 잔류분극과 항전계가 문턱전압과 드레인 유도장벽 감소에 미치는 영향 (Impact of Remanent Polarization and Coercive Field on Threshold Voltage and Drain-Induced Barrier Lowering in NCFET (negative capacitance FET))

  • 정학기
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.48-55
    • /
    • 2024
  • The changes in threshold voltage and DIBL were investigated for changes in remanent polarization Pr and coercive field Ec, which determine the characteristics of the P-E hysteresis curve of ferroelectric in NCFET (negative capacitance FET). The threshold voltage and DIBL (drain-induced barrier lowering) were observed for a junctionless double gate MOSFET using a gate oxide structure of MFMIS (metal-ferroelectric-metal-insulator-semiconductor). To obtain the threshold voltage, series-type potential distribution and second derivative method were used. As a result, it can be seen that the threshold voltage increases when Pr decreases and Ec increases, and the threshold voltage is also maintained constant when the Pr/Ec is constant. However, as the drain voltage increases, the threshold voltage changes significantly according to Pr/Ec, so the DIBL greatly changes for Pr/Ec. In other words, when Pr/Ec=15 pF/cm, DIBL showed a negative value regardless of the channel length under the conditions of ferroelectric thickness of 10 nm and SiO2 thickness of 1 nm. The DIBL value was in the negative or positive range for the channel length when the Pr/Ec is 25 pF/cm or more under the same conditions, so the condition of DIBL=0 could be obtained. As such, the optimal condition to reduce short channel effects can be obtained since the threshold voltage and DIBL can be adjusted according to the device dimension of NCFET and the Pr and Ec of ferroelectric.

강유전체를 이용한 음의 정전용량 무접합 이중 게이트 MOSFET의 문턱전압 모델 (Analytical Model of Threshold Voltage for Negative Capacitance Junctionless Double Gate MOSFET Using Ferroelectric)

  • 정학기
    • 한국전기전자재료학회논문지
    • /
    • 제36권2호
    • /
    • pp.129-135
    • /
    • 2023
  • An analytical threshold voltage model is presented to observe the change in threshold voltage shift ΔVth of a junctionless double gate MOSFET using ferroelectric-metal-SiO2 as a gate oxide film. The negative capacitance transistors using ferroelectric have the characteristics of increasing on-current and lowering off-current. The change in the threshold voltage of the transistor affects the power dissipation. Therefore, the change in the threshold voltage as a function of theferroelectric thickness is analyzed. The presented threshold voltage model is in a good agreement with the results of TCAD. As a results of our analysis using this analytical threshold voltage model, the change in the threshold voltage with respect to the change in the ferroelectric thickness showed that the threshold voltage increased with the increase of the absolute value of charges in the employed ferroelectric. This suggests that it is possible to obtain an optimum ferroelectric thickness at which the threshold voltage shift becomes 0 V by the voltage across the ferroelectric even when the channel length is reduced. It was also found that the ferroelectric thickness increased as the silicon thickness increased when the channel length was less than 30 nm, but the ferroelectric thickness decreased as the silicon thickness increased when the channel length was 30 nm or more in order to satisfy ΔVth=0.

Improved Grid Voltage Control Strategy for Wind Farms with DFIGs Connected to Distribution Networks

  • Zhang, Xueguang;Pan, Weiming;Liu, Yicheng;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제12권3호
    • /
    • pp.495-502
    • /
    • 2012
  • This paper presents an improved grid voltage control strategy for wind farms with doubly-fed induction generators (DFIGs) connected to distribution networks based on an analysis of the operation limits of DFIG systems. A modified reactive power limit calculation method in different operation states is proposed and a reactive power control strategy during grid voltage dips/rises is further discussed. A control strategy for compensating unbalanced grid voltage, based on DFIG systems, by injecting negative sequence current into the grid through the grid side converter (GSC) is proposed. In addition, the negative current limit of the GSC is discussed. The distribution principle of the negative sequence current among the different DFIG systems in a wind farm is also introduced. The validity of the proposed voltage control strategy is demonstrated by Matlab/Simulink simulations. It is shown that the stability of a wind farm and the power grid can be improved with the proposed strategy.

Pulse-Sequence Analysis of Discharges in Air, Liquid and Solid Insulating Materials

  • Suwayno, Suwayno;Mizutani, Teruyoshi
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.528-533
    • /
    • 2006
  • Electrical discharges may occur in gas, liquid as well as solid insulating materials. This paper describes the investigation results on the discharges in air, silicone oil and low density polyethylene (LDPE) using needle plane electrode system under AC voltage of 50 Hz. The experimental results showed that for discharge in air (corona), discharge pulses were concentrated around the peak of applied voltage at negative half cycle. For silicone oil positive as well as negative discharges were observed which concentrated around the peak of applied voltage. The positive pulse number was smaller but the magnitude was higher than that of negative discharge. Discharges in void took place at wider range of phase of applied voltage. The unbalance in pulse number and magnitude similar to that of oil discharges were observed. For electrical treeing in LDPE, the discharges were spread before the zero cross of the applied voltage up to the peak at both positive and negative half cycles. The discharge pulse sequence analysis indicated that the PD occurrence in air, oil and void were strongly affected by the magnitude of applied voltage. However, for electrical treeing it was observed that the discharge occurrence was strongly affected by the time derivative of the applied voltage (dv/dt).

불평형 전압 조건에 강인한 모듈형 멀티레벨 컨버터의 순환전류 억제기법 (Robust Circulating Current Control in MMC Under the Unbalanced Voltage Condition)

  • 문지우;박정우;강대욱;김장목
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.996-997
    • /
    • 2015
  • This paper proposes parameter design principle of the sub-module capacitance, Arm inductance and a control method to reduced the circulating currents in modular multilevel converter(MMC) under unbalanced voltage conditions. Under balanced voltage conditions, only negative-sequence circulating currents exist. Consequently, the conventional method has considered only negative-sequence circulating currents in MMC. However, under unbalanced voltage conditions, there are positive-sequence, zero-sequence and negative-sequence circulating currents in MMC. Thus, under unbalanced voltage conditions, a control method should consider these all components. This study proposes the control method to reduced the circulating currents under the unbalanced voltage.

  • PDF

3상 PWM 인버터를 이용한 순간전압보상기의 해석 (Analysis of Instantaneous Voltage Compensator Using 3-Phase PWM Inverter)

  • 최연규;이승요;최규하;목형수;함형원
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.222-227
    • /
    • 1997
  • Unbalanced source voltages due to unbalanced loads in the 3-phase power system is decomposed into positive, negative and zero sequence components. Also, assuming there is no neutural path in the system, the zero sequence component is not shown. Therefore, it is possible to compensate unbalanced source voltage by canceling the negative sequency component of the voltages of the source. In this paper, an algorithm compensating unbalanced source voltages by canceling the negative sequence component is presented and analysis of instantaneous voltage compensator using 3-phase PWM inverter is carried out through computer simulation.

  • PDF

Control the growth direction of carbon nanofibers under direct current bias voltage applied microwave plasma enhanced chemical vapor deposition system

  • Kim Sung-Hoon
    • 한국결정성장학회지
    • /
    • 제15권5호
    • /
    • pp.198-201
    • /
    • 2005
  • Carbon nanofibers were formed on silicon substrate which was applied by negative direct current (DC) bias voltage using microwave plasma-enhanced chemical vapor deposition method. Formation of carbon nanofibers were varied according to the variation of the applied bias voltage. At -250 V, we found that the growth direction of carbon nanofibers followed the applied direction of the bias voltage. Based on these results, we suggest one of the possible techniques to control the growth direction of the carbon nanofibers.

음이온 발생을 위한 저온 플라즈마 반응기 개발에 관한 연구 (A study on non-thermal plasma reactor for generation of negative ions)

  • 유광훈;채재우;김우형;위위;왕혜
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2344-2347
    • /
    • 2007
  • To generate negative ion, a small dielectric barrier discharge (DBD) plasma reactor was used in this study and operated by high AC voltage. With increasing of voltage, we can get more negative ions. However unfortunately, if the input voltage is too high, it will also cause formation of ozone which is very harmful to human being health. So the work of finding out the best condition of Voltage and frequency was carried out firstly. After several times of measurement, operating at 20 kHz frequency is the best condition generating high ion concentration without ozone. For the purpose of finding out the best reactor structure, two types of surface dielectric barrier discharge (DBD) reactors were examined to produce negative oxygen ions at the conditions of 20 kHz frequency. The results indicated that the surface DBD reactor with several small tips showed better characteristics for generation of negative oxygen ions at the same condition.

  • PDF

역상분 전압 주입을 이용한 태양광 인버터의 단독 운전 검출 (Anti-islanding Detection of Photovoltaic Inverter Based on Negative Sequence Voltage Injection to Grid)

  • 김병헌;박용순;설승기;김우철;이현영
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.546-552
    • /
    • 2012
  • This paper presents an active anti-islanding detection method using negative sequence voltage injection to the grid through a three-phase photovoltaic inverters. Because islanding operation mode can cause a variety of problems, the islanding detection of grid-connected photovoltaic inverter is the mandatory feature. The islanding mode is detected by measuring the magnitude of negative sequence impedance calculated by the negative sequence voltage and current at the point of common coupling. Simulation and experimental test are performed to verify the effectiveness of the proposed method which can detect the islanding mode in the specified time. The test has been done in accordance with the condition on IEEE Std 929-2000.

One-Cycle Control Strategy for Dual-Converter Three-Phase PWM Rectifier under Unbalanced Grid Voltage Conditions

  • Xu, You;Zhang, Qingjie;Deng, Kai
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.268-277
    • /
    • 2015
  • In this paper, a dual-converter three-phase pulse width modulation (PWM) rectifier based on unbalanced one-cycle control (OCC) strategy is proposed. The proposed rectifier is used to eliminate the second harmonic waves of DC voltage and distortion of line currents under unbalanced input grid voltage conditions. The dual-converter PWM rectifier employs two converters, which are called positive-sequence converter and negative-sequence converter. The unbalanced OCC system compensates feedback currents of positive-sequence converter via grid negative-sequence voltages, as well as compensates feedback currents of negative-sequence converter via grid positive-sequence voltages. The AC currents of positive- and negative-sequence converter are controlled to be symmetrical. Thus, the workload of every switching device of converter is balanced. Only one conventional PI controller is adopted to achieve invariant power control. Then, the parameter tuning is simplified, and the extraction for positive- and negative-sequence currents is not needed anymore. The effectiveness and the viability of the control strategy are demonstrated through detailed experimental verification.