Negative Corona Onset Characteristic of the UHV Conductors Based on the Corona Cage

  • Liu, Yun-Peng;Zhu, Lei;Lv, Fang-Cheng;Xie, Xiongjie
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2089-2097
    • /
    • 2014
  • Negative corona onset characteristics of the stranded conductors based on the ultra-high voltage (UHV) corona cage were studied in the paper. Based on the corona self-sustaining criterion in extreme uneven electric fields and the secondary emission process of the photoelectrons, the corona onset calculation model in the UHV corona cage is established and the corona current tests of the single LGJ900-75, 6 bundle LGJ900-75, 8 bundle LGJ400-35 conductors in dry and rain conditions were done in the UHV corona cage, and the rain rates are 2.4 mm/h, 20 mm/h and 30 mm/h. Corona onset electric field strength is gained by E-I tangent method, and the onset electric field strength in dry condition proves that the calculation model can be used to calculate the corona onset characteristics of the bundle conductors in the UHV corona cage. A further analysis proves that: the negative corona onset voltage of the conductor increases with the bundle number and the diameter of the sub conductor, but decreases with the bundle space in the corona cage. The onset electric field strength is influenced little by bundle space and bundle number, but decreases with the increase of the diameter of the sub-conductor. The surface irregularity coefficient decreases with the rain rate.

지간적 직류Corona의 실질적 검토 (Experimental Study of DC Coronas in Point-to-Plane Short Gap)

  • 오철한;이성만
    • 대한전기학회논문지
    • /
    • 제32권5호
    • /
    • pp.157-163
    • /
    • 1983
  • Positive and negative coronas in point-to-plane short gap have been investigated with the variations of point radius and gap length. Mainly the onset potentials and current pulses under various conditions were measured with a 70 MHz C.R.O. and a precise-controllable D.C. power supply. In the case of negative corona, the Trichel pulse corona, glow corona and spark regions were distinguished apparently and the critical gap lengths between them were also found clearly. In the case of positive corona, there are streamer corona, spark regions and the critical gap length between them, too. The current pulse forms of Trichel pulse corona of negative and streamer pulse corona of positive are similar in rising time, peak-to-peak time and pulse width. The glow corona current shows D.C. component in form.

  • PDF

온도변화에 따른 $SF_6$ 가스의 절연특성 (Characteristics of Dielectries in $SF_6$ Accoding to a change in Temperature)

  • 이복희;김회구;박건훈;이규선;김동성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1436-1437
    • /
    • 2007
  • This paper presents the experimental results of the dielectric characteristics with temperature changes under highly non-uniform electric field in $SF_6$ gas. The impulse preliminary breakdown developments were investigated by the measurement of predischarge current and breakdown voltage. As a result, the first stremer corona is initiated at the tip of needle electrode, and bridges the test gap. Also the first stremer corona onset and breakdown voltages the negative polarity was much higher than that in the positive polarity in same temperature. In addition, the varition of temperature have a little effect on the positive polarity. On the other hand, in some cases negative polarity corona onset and breakdown voltages increased with increasing a high temperature.

  • PDF

침대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 원통형 3전극의 영향 (Effect of a Cylindrical Third Electrode of a Point-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 문재덕;정호준;정재승
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.933-937
    • /
    • 2007
  • A point plate type nonthermal plasma reactor, with a grounded cylindrical third electrode which closely- encompasses the needle point, have been investigated with an emphasis on the role of the third electrode. It was found that the point plate airgap, with the grounded third electrode, had a switching characteristic on its I V characteristics for negative and positive discharges, which is very different from that of a conventional point plate airgap without a third electrode. The corona discharge and ozone generation characteristics of the plasma reactor with the grounded cylindrical third electrode, such as the corona onset voltage. the breakdown voltage. the corona current. and the amount of output ozone, were influenced significantly by the height of the third electrode. and these characteristics can be controlled by adjusting the height of the third electrode.

선대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 바이어스된 3전극의 영향 (Effect of the Biased Third Electrode of a Wire-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.648-652
    • /
    • 2008
  • Corona discharge and ozone generation characteristics of a wire-plate plasma reactor, with a biased third electrode, have been investigated with an emphasis on the role of the bias voltage and frequency applied on the third electrode. It was found that the wire-plate plasma reactor, with the biased third electrode, had a switching characteristic on its I-V characteristics for negative and positive discharges, which is very different from that of a conventional wire-plate plasma reactor without the third electrode. As a result, the corona discharge and ozone generation characteristics of the proposed plasma reactor could be controlled by adjusting the bias voltage and frequency of the third electrode. The corona onset and breakdown voltages, and ozone generation and yield, were increased compared with those of without the third electrode. These, however, reveal the effectiveness of the biased third electrode.

불평등전장에서 $SF_6/CO_2$ 혼합기체의 뇌임펄스 전구방전특성 (Characteristics of lightning impulse preliminary breakdown discharge under non-uniform electric field in $SF_6/CO_2$ mixtures)

  • 이복희;오성균;백영환;안창환;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2140-2142
    • /
    • 2005
  • This paper presents the experimental results on the preliminary breakdown characteristics under a highly non-uniform electric field in $SF_6/CO_2$ gas mixtures. The impulse preliminary breakdown developments are investigated by the measurements of corona current and light emission images. As a result, the preliminary breakdown development mechanisms for both positive and negative polarities are same. The first streamer corona is initiated at the tip of needle electrode, and the leaders develop with a stepwise propagation and bridge the test gap. The pause time of leader pulses in the positive polarity is significantly shorter than that in the negative polarity. Also, the time interval between the first streamer corona onset and breakdown in the negative polarity was much longer than that in the positive polarity The discharge channel paths in the positive polarity were zigzag. On the other hands, the leader channel in the negative polarity was thicker than that in the positive polarity.

  • PDF

SF6/CO2혼합기체 중에서 뇌임펄스코로나방전의 특성 (Characteristics of lightning Impulse Corona Discharges in SF6/CO2 Mixtures)

  • 이복희;백영환;오성균;안창환
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.85-90
    • /
    • 2006
  • 본 논문은 불평등 전계의 $SF_6/CO_2$혼합기체 중에서 전구방전특성에 대한 실험결과를 제시한다. 임펄스 전구방전 진전을 코로나 전류와 방전광 이미지의 측정으로 조사하였다. 정 부극성의 전구방전 진전메커니즘은 기본적으로 같았으며, 초기스트리머코로나는 침전극의 끝단에서 발단되어 계단상으로 진전하는 리더에 의해 시험갭을 교락시킨다. 정극성에서 리더펄스의 휴지시간은 부극성에서보다 매우 짧았다. 또한 부극성에서 초기스트리머코로나와 절연파괴사이의 시간간격은 정극성에서보다 매우 길게 나타났다. 정극성에서 방전채널경로는 임의적으로 나타났으며, 부극성에서 리더 채널은 정극성에서 보다 굵고 밝게 나타났다.

임펄스전압에 의한 침 대 평판전극에서 수중방전특성 (Discharge Characteristics between Needle and Plane Electrodes in Water under Impulse Voltages)

  • 최종혁;박건훈;이복희
    • 조명전기설비학회논문지
    • /
    • 제22권8호
    • /
    • pp.67-74
    • /
    • 2008
  • 이 논문은 수중의 침 대 평판 전극에서 임펄스전안의 크기와 극성, 물의 저항률 등과 같은 다양한 조건에 따른 방전특성을 나타낸다. 스트리머코로나가 침전극 끝단에서 발생하며 평판전극을 향하여 진전하여 최종적으로 전극 사이가 섬락에 이르게 된다. 동일한 전압에서 물의 저항률이 작을 때 스트리머코로나의 분기로는 물의 저항률이 클때 보다 더욱 굵고 밝게 나타났다. 정극성에 비해서 부각성 스트리머코로나가 더욱 많은 분기로를 형성하며 더욱 넓게 퍼지는 것으로 나타났다. 스트리머코로나의 개시 후 방전의 진전과 더불어 수 백 [mA]에서 수 [A]에 이르는 많은 수의 전류펄스가 발생하였다. 정극성의 절연파괴까지의 지연시간은 부극성에 비하여 매우 짧았으며, 전극에 공급되는 전구방전에너지는 물의 저항률에 반비례하였다.

$SF_6$$SF_6/CO_2$ 혼합기체 중에서의 뇌임펄스 전구방전의 특성 (Characteristics of lightning impulse pre-breakdown discharge in $SF_6\;and\;SF_6/CO_2$ mixtures)

  • 이복희;오성균;백영환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.57-60
    • /
    • 2005
  • This paper describes the experimental results of the pre-breakdown phenomena in $SF_6/CO_2$ mixtures under non-uniform electric fields caused by positive and negative lightning negative voltages. $SF_6/CO_2$ mixtures have an advantage of an environmental aspect and cost reduction, and safety aspects. In order to analyze the pre-breakdown processes in $SF_6/CO_2$ mixtures stressed by impulse voltages, pre-breakdown current and luminous signals were measured by a shunt and a photo-multiplier tube, respectively. Dielectric strengthes of $SF_6/CO_2$ mixtures were investigated. Additionally, characteristics of discharge channels were observed by high speed cameras and the physical properties were discussed. The pre-breakdown propagates with a stepwise process. The in to breakdown from the corona onset point in positive polarity was shorter than that in negative polarity. The time intervals of positive leaders are shorter than those of negative leaders, and the path of positive leader channel is zigzag.

  • PDF