• 제목/요약/키워드: Negative corona discharge

검색결과 54건 처리시간 0.023초

고전계하에서 유전체 전극에 나타나는 코로나 현상 (Corona Discharge Phenomena on the Dielectric Electrodes in High Field)

  • 김정달;이덕진;주성철;정장근;장기혁;이세훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1598-1600
    • /
    • 1998
  • When dielectric surface electric field exceed any electric field strength on air, corona discharge is occurred from the dielectric surface. This paper presents corona discharge phenomena on the dielectric in high field were studied under application of ${\pm}DC$ voltage, constitute of the point to plane 20mm gap. The results obtained in experimental are summarized as follow :(1) Corona pulse is appeared periodically after first corona pulse is occurred and the number of corona pulse increases with the instantaneous applied voltage but peak value is not changed greatly.(2)Applied voltage to beccrite and characteristics and peak value of current are almost a straight line. That kind of tendency accorded with characteristics of beccrite resistance.(3)In case of Positive corona, Positive streamers, were progressed greatly to plane electrodes but In case of negative corona, negative streamers smaller than that of Positive corona.

  • PDF

DC 코로나 방전이 적용된 에틸렌 정상 확산 화염의 Soot 배출 저감 (Reduction of Soot Emitted from a $C_2$$H_4$ Normal Diffusion Flame with Application of DC Corona Discharge)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.496-506
    • /
    • 2001
  • The effect of corona discharge on soot emission was experimentally investigated. Size and number concentrations of soot aggregates were measured and compared for various voltages. Regardless of the polarity of the applied voltage, the flame length decreased and the tip of flame spreaded with increasing voltage. For the experimental conditions selected, the flame was blown off toward the ground electrode by corona ionic wind. When the negative applied voltage was greater than 3kV(for electrode spacing = 3.5cm), soot particles in inception or growth region were affected by the corona discharge, resulting in the reduction of number concentration. The results show that the ionic wind favored soot oxidation and increased flame temperature. Number concentration and primary particle size greatly increased, when the corona electrodes were located the region of soot nucleation or growth(close to burner mouth).

코로나 선전극의 직경과 극성변화에 따른 오존발생특성 (Characteristics of Ozone Generation by Diameter and Polarity Variation of Corona Wire Electrode)

  • 정재승;김진규
    • 조명전기설비학회논문지
    • /
    • 제26권5호
    • /
    • pp.85-90
    • /
    • 2012
  • In this paper, it was investigated experimentally that diameter and polarity variation of corona wire electrode affected to ozone generation of the ozone generator using a wire-to-plate type electrode. The change in the diameter(D) of the corona wire electrode has a great effect upon ozone generation, higher influence appears in the positive corona discharge than the negative corona discharge. In the case of D=0.50[mm], maximum ozone generation and power efficiency could be obtained. However, in the case of smaller D than this, the ozone generation and efficiency decreases slowly and in the case of larger D, the ozone generation decreases rapidly. It means performance decline as an ozone generator. Therefore, ozone generation and power efficiency would increase through simple optimization of the corona electrode specification.

선대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 바이어스된 3전극의 영향 (Effect of the Biased Third Electrode of a Wire-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 정재승;문재덕
    • 전기학회논문지
    • /
    • 제57권4호
    • /
    • pp.648-652
    • /
    • 2008
  • Corona discharge and ozone generation characteristics of a wire-plate plasma reactor, with a biased third electrode, have been investigated with an emphasis on the role of the bias voltage and frequency applied on the third electrode. It was found that the wire-plate plasma reactor, with the biased third electrode, had a switching characteristic on its I-V characteristics for negative and positive discharges, which is very different from that of a conventional wire-plate plasma reactor without the third electrode. As a result, the corona discharge and ozone generation characteristics of the proposed plasma reactor could be controlled by adjusting the bias voltage and frequency of the third electrode. The corona onset and breakdown voltages, and ozone generation and yield, were increased compared with those of without the third electrode. These, however, reveal the effectiveness of the biased third electrode.

이종방전 중첩에 의한 방전 플라스마반응기의 효율개선의 시도 - 연면.직류코로나 방전 중첩형 반응기의 특성 - (A Trial for Improvement of Energy Efficiency of Plasma Reactor by Superposing Two Heterogeneous Discharges - Characteristics of Surface and Corona Discharge Combined Plasma Reactor -)

  • 우인성;;황명환
    • 한국안전학회지
    • /
    • 제15권3호
    • /
    • pp.66-70
    • /
    • 2000
  • In order to cope with environmental problems caused by harmful gases emitted from various industrial sources, a new technology which employs discharge plasma formed in ordinary atmospheric pressure has been intensively investigated in many industrialized nations. Although a plenty of useful outcomes and suggestions have been made public by scientists in this field, few commercial products which effectively decompose pollutant gases have appeared as yet. This is partly because that the energy efficiency of a most effective plasma reactor has not reached a satisfactory level in comparison with those of devices using conventional technologies. In an attempt to solve the problem mentioned above, we noticed to combine heterogeneous electrical discharges. This concepts is based on that each plasma reactor has its specific spatial region in which chemical reaction are active and by electrically affected with another reactor of different type, the activated region would increase - which may lead to cutting down the energy consumption. To prove this concept experimentally, two different discharge equipments, a plane ceramic-based surface discharge electrode and a corona electrode with tungsten needle may, are selected and combined to fabricate a hybrid plasma reactor. The results are summarized as follows; (1) Ozone concentration generated in the plasma region drastically increases when the positive corona discharge is added to the surface discharge. The rate of increase of ozone depends on the frequency of the surface discharge. The negative corona, however, does not contribute to the improvement of the ozone generation. (2) NO(nitrogen monoxide) decomposition rate also improves by simultaneously applying the surface and the positive corona discharges. The effect of the corona superposition is more evident when the level of the surface discharge is moderate. (3) By adjusting the corona level, the net energy efficiency during NO decomposition improves in comparison with the simple surface discharge reactor.

  • PDF

Design and Evaluation of a High Concentration, High Penetration Unipolar Corona Ionizer for Electrostatic Discharge and Aerosol Charging

  • Intra, Panich;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1175-1181
    • /
    • 2013
  • The aim of this paper is to design and evaluate a high concentration, high penetration unipolar corona ionizer. The electrostatic characteristics in terms of voltage-current relationships of the present ionizer in the discharge zones for positive and negative coronas were discussed. Using ion current measurement, the concentration and penetration of ions were evaluated at corona voltages across the needle electrodes between 1 and 4 kV, flow rates between 1 and 5 L/min, and an operating pressure of 1 atm. In the discharge zone of the ionizer, the highest ion concentrations were found to be about $1.71{\times}10^{14}$ and $5.09{\times}10^{14}\;ions/m^3$ for positive and negative coronas, respectively. At the outlet of the ionizer, it was found that the highest ion concentration was about $1.95{\times}10^{13}$ and $1.91{\times}10^{13}\;ions/m^3$ for positive and negative coronas, respectively. The highest ion penetration for positive and negative coronas through the ionizer was found to be about 98 % and 33 %, respectively. The $N_it$ product for positive and negative coronas was also found to $1.28{\times}10^{13}$ and $7.43{\times}10^{13}\;ions/m^3s$, respectively. From the findings, this ionizer proved to be particularly useful as an aerosol charger for positive and negative charge before the detector in an electrical aerosol detector.

수성(水性)펜침(針) 대(對) 절연지부착평판간(絶緣紙附着平板間)의 방전특성(放電特性) (Discharge Characteristics from a Water-Penpoint-to - Insulator-Paper-Covered-Plate Airgap)

  • 문재덕;이대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1586-1588
    • /
    • 1994
  • Some interesting corona characteristics of a airgap of penpoint-to-plate with a tracing insulator paper has been investigated in a temperature and humidity controlled metal chamber. It is found that the positive and the negative carriers in the plasma region could be understood from the waterdrop traces on the paper, which indicate the bombardment by the one of electron or positive gas particle from the plasma region of near the point. It is also found that a corona discharge could be used as a means of a humidifying, since the discharge makes dispersion of watersprays from the penpoint. And the negative corona was more effective for waterspray dispersion than the positive ones.

  • PDF

침대 평판형 플라즈마장치의 코로나 방전 및 오존발생 특성에 미치는 원통형 3전극의 영향 (Effect of a Cylindrical Third Electrode of a Point-Plate Type Plasma Reactor on Corona Discharge and Ozone Generation Characteristics)

  • 문재덕;정호준;정재승
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.933-937
    • /
    • 2007
  • A point plate type nonthermal plasma reactor, with a grounded cylindrical third electrode which closely- encompasses the needle point, have been investigated with an emphasis on the role of the third electrode. It was found that the point plate airgap, with the grounded third electrode, had a switching characteristic on its I V characteristics for negative and positive discharges, which is very different from that of a conventional point plate airgap without a third electrode. The corona discharge and ozone generation characteristics of the plasma reactor with the grounded cylindrical third electrode, such as the corona onset voltage. the breakdown voltage. the corona current. and the amount of output ozone, were influenced significantly by the height of the third electrode. and these characteristics can be controlled by adjusting the height of the third electrode.

A New Type of Nonthermal Plasma Reactor

  • Geum, Sang-Taek;Moon, Jae-Duk;Jun, Sun-Gon
    • The Korean Journal of Ceramics
    • /
    • 제5권3호
    • /
    • pp.245-249
    • /
    • 1999
  • A new type of nonthermal plasma reactor utilizing ferroelectric pellets is proposed to generate nonthermal plasma efficiently, which is used for simultaneous control of various pollutant gases. Electric charges stored on ferroelctric pellets by corona discharge between a corona tip and a mesh electrode provide partial electrical discharges among ferroelectric pellets. These partial electrical discharges can enhance partial discharges around the surface of ferroelectric pellets. This method utilizes wide reacting area of ferroelectric pellets and partial discharge. Positive and negative dc voltage are applied to the corona tip to generate partial discharges, and corona currents are estimated to investigate charge storage on ferroelectric pellets as function of time and charge relaxation time constants of ferroelectric pellects. As a result, charge relaxationtime, dielectric constants of ferroelectric pellets, polarity of applied voltage and applied time influence partial discharges among ferroelectric pellect.

  • PDF