• 제목/요약/키워드: Negative Permeability

검색결과 110건 처리시간 0.025초

시판 한복지의 열.수분이동 특성 (Heat ,rind Moisture Transfer Properties of Fabrics for Korean Folk Clothes)

  • 성수광;성은정
    • 한국의류학회지
    • /
    • 제20권6호
    • /
    • pp.1071-1083
    • /
    • 1996
  • This study was carried out to obtain some fundamental data for designing thermally comfortable Korean folk clothes (KFC) which were classified into 4 groups according to seasons and materials. It was conducted to find the relationship among structural, thermal, and moisture transfer properties, and then the properties of heat and mositure transfer while changing thickness of air layer of selected similar fabrics with various thickness were examined. The summarized results of this study were as follows ; 1. The relationship between the structrual and thermal properties showed high positive correlation with thickness SE thermal insulation value (TIV), porosity & TIV. 2. The relationship between the structural and mositure transfer properties showed high negative correlation with thickness & moisture vapor permeability (Mp), porosity & Mp respectively. 3. The relationship between the heat and moisture transfer properites showed high negative correlation with qmax, air permeability (Ap), Mp & TIV while showed high positive with Ap & Mp respectively. 4. Resistance to dry heat transfer according to thickness of air layer for KFC was increassed rapidly up to 2 mm and above this increasing rate was reduced. Resistance to evaporative heat transfer was remarkable changes in 6∼8 mm but slowly in 6∼8 man. 5. Mioisture permeability index (i) according to thickness of air layer for KFC showed the greatest value at 2 mm but had not difference between groups according to thickness.

  • PDF

모래층에서의 수류의 특성에 관한 실험적 연구 (Experimental Study on the Characteristics of Water Flow Through Sand Layer)

  • 남궁달;김철기
    • 한국농공학회지
    • /
    • 제17권3호
    • /
    • pp.3833-3839
    • /
    • 1975
  • The object of this experiment is to find out some flow characteristics of water through sand layer, to prevent moving sands in the filters of the fill Dam, infiltration gallery, well and Deversion Weir. This experiment was accomplished with different particle Sizes of Six Samples and different hydraulic gradient. The results obtained are Summarized as follows. 1. The critical hydraulic gradients for laminar flow was found to be between 1 and 2 when the sand used had the effective diameter, D10 of between 0.18cm and 0.45cm. 2. The critical hydraulic gradients for different particle sizes of sands were varied considerably. 3. There was a negative correlation between critical hydraulic gradient and critical Velocity, and between effective particle diameter D10 and critical hydraulic gradient respectively. 4. In spite of relatively small variation of void ratio of sands used, the values of the coefficient of permeability varied considerably. There was a negative correlation between coefficient of permeability and void ratio.

  • PDF

DC 마그네트론 스퍼터로 증착한 flexible OLED용 IZO 박막의 기계적 특성과 투습특성에 미치는 반응성 가스 첨가의 효과 (Effects of Reactive Gas Addition on the Mechanical Property and Water Permeability of IZO Films Deposited by DC Sputtering for Application to Flexible OLED)

  • 천고은;이동엽;조영래;송풍근
    • 한국표면공학회지
    • /
    • 제40권6호
    • /
    • pp.245-249
    • /
    • 2007
  • Amorphous IZO films were deposited on PET substrate by DC magnetron sputtering without substrate heating. In order to investigate effect of reactive gas addition on film properties, 0.2-0.4% of $H_2$ or $O_2$ gas was introduced during the deposition. Deposited IZO films were evaluated with mechanical property, electrical property, and water permeability. In the case of $H_2$ gas addition, mechanical property showed clear degradation compared to $O_2$ gas. In the case of $O_2$ gas, water permeability of the IZO film was increased compared to $H_2$ gas which could be attributed to the low adhesion of the film caused by bombardment of high energy negative oxygen ion. As a result, it is confirmed that water permeability of the film could be strongly affected by adhesion of the film.

A Sub-Wavelength Focusing Lens Composed of a Dual-Plate Metamaterial Providing a Negative Refractive Index

  • Kim, Dong-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제12권1호
    • /
    • pp.26-31
    • /
    • 2012
  • We have proposed a metamaterial lens that enables sub-wavelength focusing, which is shorter than an operating wavelength. Our lens is a two dimensional array of a unit cell consisting of a metallic dual-plate printed on a dielectric substrate. The unique dual-plate structure provides negativeness both in permittivity and permeability, with no help from conventional additional structures, which are normally printed on the opposite of metallic patterns. Therefore, we can focus a source (or an image) in a tiny distance shorter than the free space wavelength (${\lambda}$) at the frequencies of interest. Furthermore, since the proposed geometry does not need separate supplementary structures to acquire negative permittivity or permeability, our lens is much simpler than conventional metamaterial lenses, which is a strong point in practical applications. We have validated sub-wavelength focusing ability in a 6 GHz frequency band through an experiment of near field scanning, which provided the width of about 0.19 ${\lambda}$ at a half maximum of a peak value of an measured image. The width of the focused image through the lens is more than 4 times shorter than that without the lens, which confirms the validity of our design approach.

두 쌍의 ELC 공진기를 이용한 이중 대역 메타 흡수체의 설계 (Design of Dual-band Metamaterial Absorber using Two Pairs of ELC Resonators)

  • 이형섭;이홍민
    • 한국정보전자통신기술학회논문지
    • /
    • 제5권1호
    • /
    • pp.26-32
    • /
    • 2012
  • 본 논문에서는 4개의 ELC 공진기 구조를 사용하여 메타 흡수체 구조의 단위 셀을 설계하였다. 제안된 구조의 단위 셀의 크기는 $9mm{\times}9mm{\times}2mm$ 이다. 메타 흡수체의 대역폭 확장을 위하여 흡수체 단위 셀은 서로 다른 크기를 갖는 2 쌍의 ECL가 사용되었다. 제안된 흡수체는 전계가 ELC 갭에 수평하게 여기되고 자계가 단위 셀 면에 수직으로 여기 될 경우에 음의 유전율과 음의 투자율 특성을 나타낸다. 제안된 단위 셀은 8.53 GHz, 9.08 GHz에서 공진을 하며 각 주파수에서 90%이상의 흡수율을 갖는다.

Theoretical considerations on the giant magnetoimpedance effect in amorphous ribbons

  • Phan, Manh-Huong;Nguyen Cuong;Yu, Seong-Cho
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2003년도 하계학술연구발표회 및 한.일 공동심포지엄
    • /
    • pp.60-61
    • /
    • 2003
  • Theoretical considerations on a giant magneto-impedance (GMI) effect in amorphous ribbons (i.e., thin films) have been made in terms of the expressions of effective permeability and impedance derived in the frame of classical electrodynamics and ferromagnetism. The dependence of GMI effect on the external do magnetic field (H$\_$ext/) and the frequency of alternating current are simulated and discussed in the knowledge of energy conversion consisting of the current energy loss, the ferromagnetic energy consumption, and the magnetic energy storage in the film. The obtained results are summarized as follow: (a) As frequency f< 20 ㎒, the real part of effective permeability (${\mu}$′) changes slightly. The peak of the ${\mu}$′curve always locates at H$\_$ext/=H$\_$ani/ - the anisotropy field. However, the peak value of ${\mu}$′ tends to increase with increasing frequency in the frequency range of 11-20 ㎒. (b) In the frequency range, f= 21-23 ㎒, a negative peak additionally appears. Meanwhile, both the positive and negative peak values rapidly increase with increasing frequency and their peak positions shift towards a high H$\_$ext/. (c) The positive peak value of ${\mu}$′ starts to decrease at f= 29 ㎒ and its negative peak does so at about 35 ㎒. Then, both peaks keep such a tendency and their peak positions move to high H$\_$ext/, as increasing frequency. (d) The dependence of the imaginary part of effective permeability (${\mu}$") on the external dc magnetic field and the frequency of the alternating field indicates that there is only one peak involved in ${\mu}$" for the whole frequency range. (e) The impedance vs. magnetic field curves at various frequencies show that there is a critical value of frequency around f= 18-19 ㎒ where the transition between two frequency regimes occurs; the one (low frequency) in which ${\mu}$′ predominantly contributes to the GMI effect and the other (high frequency) in which ${\mu}$" determines the GMI effect.

  • PDF

Optimization for Permeability and Electrical Resistance of Porous Alumina-Based Ceramics

  • Kim, Jae;Ha, Jang-Hoon;Lee, Jongman;Song, In-Hyuck
    • 한국세라믹학회지
    • /
    • 제53권5호
    • /
    • pp.548-556
    • /
    • 2016
  • Recently, porous alumina-based ceramics have been extensively applied in the semi-conductor and display industries, because of their high mechanical strength, high chemical resistance, and high thermal resistance. However, the high electrical resistance of alumina-based ceramics has a negative effect in many applications due to the generation of static electricity. The low electrical resistance and high air permeability are key aspects in using porous alumina-based ceramics as vacuum chucks in the semi-conductor industry. In this study, we tailored the pore structure of porous alumina-based ceramics by adjusting the mixing ratio of the starting alumina, which has different particle sizes. And the electrical resistance was controlled by using chemical additives. The characteristics of the specimens were studied using scanning electron microscopy, mercury porosimetry, capillary flow porosimetry, a universal testing machine, X-ray diffraction, and a high-resistance meter.

Relationship Between AC and DC Magnetic Properties of an Iron-Based Amorphous Alloy for High Frequency Applications

  • Choi, Y.S.;Noh, T.H.;Lim, S.H.
    • Journal of Magnetics
    • /
    • 제1권1호
    • /
    • pp.24-30
    • /
    • 1996
  • The relationship between effective permeability and the remanence ratio of an Fe-based amorphous alloy (Metglas 2605S3A) is investigated over a wide frequency range, in an effort to understand magnetization behavior of the alloy. In the frequency range from 1 to 200 kHz, the permeability is maximum at the remanence ratio of 0.4-0.5 and, at frequencies over 500 kHz, the correlation with negative coefficients emerges indicating that the permeability decreases with the remanent ratio, except for the ribbon coated with an insulating layer of MgO which exhibits both high values of the effective permeability and remanence ratio. It is considered from the correlation results that the boundary at which the dominant magnetization mechanism changes from domain wall motion to spin rotation is near 500 kHz. The core loss is also investigated as a function of annealing time when the samples are annealed at a fixed temperature of $435^{\circ}C$. The core loss in most cases decreases with the annealing time, the degree of the loss may consist of the hysteresis loss and anomalous eddy current loss. The two loss components are considered to be of similar magnitudes at low frequencies while, at high frequencies, the dominant contribution to the total loss is the anomalous loss.

  • PDF

Novel Planar Metamaterial with a Negative Refractive Index

  • Kim, Dong-Ho;Choi, Jae-Ick
    • ETRI Journal
    • /
    • 제31권2호
    • /
    • pp.225-227
    • /
    • 2009
  • A new planar metamaterial (MTM) with simultaneous negative values of permittivity (${\varepsilon}$) and permeability (${\mu}$) is proposed. Our MTM is composed of two identical copper patterns etched on both sides of dielectric laminate, which is very thin and easy to fabricate. Unlike conventional MTMs, the proposed structure shows a negative refractive index (NRI) behavior with respect to a normally incident wave. To explain the underlying principle of the NRI characteristics, an equivalent resonant circuit model based on surface current density distribution is investigated. An eigenmode analysis and a three-dimensional wave simulation for the stacked MTM prism are also performed to verify the existence of negative refraction. The experimental results from the transmission and reflection measurement ensure the validity of our design approach and show good agreement with the theoretically predicted effective medium parameters.

  • PDF

Antimicrobial Agents That Inhibit the Outer Membrane Assembly Machines of Gram-Negative Bacteria

  • Choi, Umji;Lee, Chang-Ro
    • Journal of Microbiology and Biotechnology
    • /
    • 제29권1호
    • /
    • pp.1-10
    • /
    • 2019
  • Gram-negative pathogens, such as Klebsiella pneumoniae, Pseudomonas aeruginosa, and Acinetobacter baumannii, pose a serious threat to public health worldwide, due to high rates of antibiotic resistance and the lack of development of novel antimicrobial agents targeting Gram-negative bacteria. The outer membrane (OM) of Gram-negative bacteria is a unique architecture that acts as a potent permeability barrier against toxic molecules, such as antibiotics. The OM is composed of phospholipids, lipopolysaccharide (LPS), outer membrane ${\beta}-barrel$ proteins (OMP), and lipoproteins. These components are synthesized in the cytoplasm or in the inner membrane, and are then selectively transported to the OM by the specific transport machines, including the Lol, BAM, and Lpt pathways. In this review, we summarize recent studies on the assembly systems of OM components and analyze studies for the development of inhibitors that target these systems. These analyses show that OM assembly machines have the potential to be a novel attractive drug target of Gram-negative bacteria.