3개 구동방식(SI, PI, DPI)별 디젤HEV용 인젝터의 분무 특성 비교 (Comparison on Spray Characteristics of Diesel HEV Injectors for 3-different Driving Type (SI, PI, DPI))

  • 정명철;성기수;김상명;이진욱
    • 한국분무공학회지
    • /
    • 제19권1호
    • /
    • pp.9-14
    • /
    • 2014
  • Performance of DI diesel engine with high-pressure fuel injection equipment is directly related to its emission characteristics and fuel consumption. So, the electro-hydraulic injector for the common-rail injection system should be designed to meet the precise high fuel delivery control capability. Currently, most high pressure injector in use has a needle driven by the solenoid coil energy or the piezo actuator controlled by charge-discharge of output pulse current. In this study, macroscopic spray approaching method was applied under constant volume chamber to research the performance of three different injectors : solenoid, indirect-acting piezo and direct-acting piezo type for CR direct-injection. LED back illumination for Mie scattering was applied on the liquid spray visible of direct-acting piezo injector, including hydraulic-servo type solenoid and piezo-driven injectors. As main results, we found that a direct-acting piezo injector had better a spray tip penetration than hydraulic-servo injectors in spray visualization.

커먼레일 고압분사용 인젝터의 분공수 및 니들구동특성이 Pilot 분무에 미치는 영향 (Effect of Injection Hole and Needle-driven Characteristics on Pilot Spray in High Pressure Injector with Common-rail System)

  • 이진욱;배장웅;김하늘;강건용;민경덕
    • 한국분무공학회지
    • /
    • 제9권1호
    • /
    • pp.8-14
    • /
    • 2004
  • future exhaust emission limits for diesel-driven passenger cars will force the automotive company to significantly develop of the new technologies of diesel engine respectively of the drive assemblies. As we know, the contributions of soot and nitrogen oxide is the main problems in diesel engine. Recently, as a result, the pilot injection of common-rail fuel injection system recognizes an alternative function to solve an environmental problem. This study describes the effect of the nozzle structure and driven characteristic of injector on pilot injection fur a passenger car common-rail system. The pilot spray structure such as spray tip penetration, spray speed and spray angle were obtained by high speed images, which is measured by the Mie scattering method with optical system fur high-speed temporal photography. Also the CFD analysis was carried out for fuel behavior under high pressure in between needle and nozzle of injector for common-rail system to know the condition of initial injection at experiment test. It was found that solenoid-driven injector with 5-hole was faster than 6-hole injector in spray speed at same conditions and piezo-driven injector showed faster response than solenoid injector.

  • PDF

공압시험을 이용한 추력가변 노즐의 정상상태 성능 연구 (A study on steady state performance of variable thrust nozzle by cold-flow test)

  • 김중근;이지형;오종윤;장홍빈;김신회
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.289-294
    • /
    • 2007
  • 고체 추진기관은 높은 비추력, 운용 안전성, 설계/제작하기가 쉽다는 장점이 있으나 추력 크기를 조절할 수 없다. 본 논문에서는 고체 추진기관의 추력을 조절할 수 있는 핀틀 노즐성능에 대한 연구로 Needle형 핀틀을 사용하여 수행한 공압 시험결과와 수치해석 결과를 수록하였다. 연구의 결과, 핀틀 노즐의 추력성능과 추력변화 범위는 핀틀 팁의 형상과 노즐의 Contour형상에 크게 의존하기 때문에 핀틀 팁의 형상과 노즐의 Contour형상은 중요한 설계 변수임을 알 수 있었고 특히, 시험에 적용된 Needle형 핀틀 노즐의 성능은 기존 노즐 대비 약 13%의 추력상승이 예측됨을 알 수 있었다.

  • PDF

가교폴리에틸렌 지중케이블에서 화상계측을 이용한 수트리 열화현상 분석 (The Analysis of Water Tree Degradations in Underground Distribution Cables Using Image Measurement)

  • 김덕근;임장섭;이진;이준웅;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.19-23
    • /
    • 1998
  • Water tree degradations have been considered as one of the most important causes of failure in underground distribution cables with polymeric insulation. Water tree growth is a preliminary step in the sequence of electrical tree initiation and electrical breakdown of the insulation. In this paper, needle electrode is made use of the etching methods and the pellet type specimen is made to observe the water tree in succession. In previous methods are able to observe the tree degradations without cutting and dyeing. The water tree image is recorded on VTR with CCD camera. The tree length of X, Y axis direction and aging area(treeing area) are calculated with image measurement. As a result of this study, water tree is observed by non-destructive method. Electrical tree is initiated from needle electrode tip only but water tree is initiated from total area of water electrode. Electrical tree owing to water treeing is initiated at low electric field and grown with discontinuously. Namely, water tree is shown up a different characteristics of tree growth.

  • PDF

고체유전체의 장벽과 도전성 파티클이 섬락전압에 미치는 영향 (Influence of Flash-over Voltage on Conductive Particle-Initiated and Solid Dielectric Barrier)

  • 이용길;김동의;이세헌;김재호;김정달
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권3호
    • /
    • pp.54-63
    • /
    • 1994
  • 본 연구에서는 판상스페이서 위에 침전극을 고정하고 gap간격 40[mm]에 평판전극을 설치한 gap 간에 10[mm]간격으로 나누어 각 구간내에 스페이서와 같은 재질의 Barrier를 설치하고 파티클을 두었을 때 AC 및 정극성 DC 전압에서의 방전로와 FOV에 대해 연구한 결과 다음과 같은 결론을 얻엇다. 1) Barrier가 고전위측에 위치한 경우와 파티클이 Barrier뒤에 은폐된 경우가 FOV가 높다. 2) 침전극 선단에 파티클 위치할 때 심한 FOV의 감소가 있다. 3) 파티클이 전극간에 게재되면 방전로는 파티클을 경유하므로 FOV는 감소한다.

  • PDF

Electrical Properties Associated with Discharge Developments in Water Subjected to Impulse Voltages

  • Choi, Jong-Hyuk;Lee, Bok-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.156-162
    • /
    • 2010
  • This paper describes electrical and optical characteristics of discharge developments in water under inhomogeneous fields caused by impulse voltages. Predischarge current and discharge light images were observed for different water resistivities and applied voltages between the hemispherical water tank and the needle electrode. The electrical parameters characterizing discharge developments are analyzed based on the discharge light images and voltage-current (V-I) curves, and electrical resistances derived by voltage and current waveforms. As a result, when the streamer corona is initiated at the tip of the needle electrode, the transient resistance suddenly drops and V-I curves form a 'loop'. The length of streamer propagation is increased with increasing peak value of the applied voltage, and the streamer corona extension is enlarged with increasing water resistivity. The electrical resistances before streamer corona initiation are rarely changed by different applied voltages. On the other hand, the electrical resistances after streamer corona initiation are found to be inversely proportional to the peak value of the applied voltage, and the decreasing rates for higher water resistivities are much higher than those for lower water resistivities. The time to streamer corona initiation and the time to the second current peak become shorter as the voltage increases. Finally, the calculated resistances after streamer corona initiation are almost the same trace of measured resistances, but they are smaller than the measured values.

비전도성 액체의 전기수력학적 미립화를 위한 전하 주입 특성에 관한 실험적 연구 (An Experimental Study on Charge Injection to Non-Conducting Liquid for Electrohydrodynamic Atomization)

  • 이기준;박종승;이상용
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1376-1383
    • /
    • 2004
  • In the present work, a series of experiments have been performed on electro-hydrodynamic atomization of non-conducting liquid using a charge injection type nozzle. Effects of liquid flow rate, input voltage, and distance between the needle and the ground electrode (nozzle-embedded metal plate) have been examined. For fixed electrode distances, total and spray currents increase with the increase of liquid flow rate and input voltage. When the distance between the needle tip and the ground electrode becomes closer, the total, leakage and spray currents increase, while the onset voltage for the dielectric breakdown decreases. When the electric field strength of the liquid jet exceeds that for the air breakdown, a portion of the electric charges in the liquid jet is dissipated into the ambient air, and the charge density shows a limiting value. Atomization quality can be improved by increasing the liquid flow rate due to the higher charge density and the enhanced aerodynamic effect.

경사 LIGA 공정을 이용한 미세 바늘 어레이의 제작 (Fabrication of Microneedle Array Using Inclined LIGA Process)

  • 문상준;이승섭
    • 대한기계학회논문집A
    • /
    • 제28권12호
    • /
    • pp.1871-1876
    • /
    • 2004
  • We demonstrate a novel fabrication technology for the microneedle array that can be used in the medical test field, which is transdermal drug delivery and blood analyte sampling. Previous researchers have used silicon-processed micromachining, a reactive ion etching, and molding techniques for the fabrication of microneedle array. However, these fabrication techniques have somewhat limitations apply to the microneedle array fabrication according to its application. Inclined LIGA process is suggested to overcome these problems. This process provides easier, sharper and longer out-of-plane microneedle array structure than conventional silicon-processed fabrication method did. Additionally, because of the advantage of the LIGA process based on mold fabrication for mass production, the polymer, PMMA(PolyMethylMethAcrylate), based microneedle array is useful as the mold base of nickel electroplating process; on the other hand, silicon-processed microneedle array is used in itself. In this research, we fabricate different types of out-of-plane microneedle array, which have different shape of tip, base and hole structure, using the inclined LIGA process. The fabricated microneedles have proper mechanical strength, height and sharpness to puncture human hand epidermis or dermis with less pain and without needle tip break during penetrating the skin.

완관절(腕關節) 결정종(結節腫)에 대한 배담(排痰)·양자침구치료(揚刺鍼灸治療)의 임상적(臨床的) 관찰(觀察) (Clinical Study on Wrist Ganglion by Newly Transformed Centro-Square Acupuncture·Moxibustion)

  • 김기현
    • Journal of Acupuncture Research
    • /
    • 제17권4호
    • /
    • pp.113-119
    • /
    • 2000
  • Objectives : Wrist ganglion is one of the most common diseases on the wrist joint. So far acupuncture, medication, drainage and local anesthetic excision therapy have been used for this disease, but the development of more effective treatment method is being expected because of frequent recurrence and side effect. Considered that most ganglion is polycystic, on the basis of classic centro-square acupuncture, newly transformed centro-square acupuncture was applied to this report. Methods : All the patients with wrist ganglion was divided into two groups. Newly transformed centro-square acupuncture was app(ied to one group composed of 11 patients and classic centro-square acupuncture to the other group with 19 patients. Classic centro-square acupuncture is made up of slanting and straight insertion. the former is a method that tips of 4 needles are inserted from the outersurface of wrist ganglion oriented to the center of the ganglion, the latter is that tip of one needle is inserted on the center of the ganglion straightly. In the newly transformed centro-square acupuncture, straight insertion of dry needle was taken place of by syringe needle in order to drain phlegm. In this report, classic and newly transformed centro-square acupuncture were used somewhat differently from original ones. Moxibustion was applied after removing all the needles. In newly transformed centro-square acupuncture, moxibustion was also applied after drainage of phlegm and slanting insertion. Results : 1. Wrist ganglion was frequently developed around the acupoint of Tae-Yeon(Tai Yuan, LU9) and Yang-Ji(Yang Chi, TE4) and the difference between occurrence of development on the left and right hand had no significancy. 2. The mean number of treatment for recovery : The newly transformed centro-square acupuncture had fewer treatment than classic one. 3. The newly transformed centro-square acupuncture was more effective than classic one. 4. As a result of following up 6 to 72 months after wrist ganglion had been eliminated, there was no recurrence. Conclusion : In the treatment of wrist ganglion, newly transformed centro-square acupuncture can be regarded as more useful method in the clinical practice, because it has comparatiely shorter duration of treatment and is more effective.

  • PDF

Comparison of the mechanical efficacy of sonic activated irrigation and passive ultrasonic irrigation for intracanal medicaments removal

  • Jang, Ju-Kyong;Kwak, Sangwon;Choi, Ga Young;Ha, Jung-Hong;Choi, Sung-Baik;Kim, Hyeon-Cheol
    • 대한치과의사협회지
    • /
    • 제53권10호
    • /
    • pp.743-750
    • /
    • 2015
  • Objectives: This study compared the mechanical efficacy of sonic activated and passive ultrasonic irrigation for removing intracanal medicament from a simulated root canal under controlled conditions. Materials and Methods: Thirty simulated root canal in resin blocks were randomly divided into 3-groups. The canals were enlarged using ProTaper files and K3XF (#30/0.06). After cleaning and drying, canals were filled with Calcipex. Overfilled materials were wiped out and measured their weight to the unit of 1/10mg. After one week storage in 100% humidity $37^{\circ}C$ temperature, canals were irrigated using 20mL of saline with one of following methods according to the designated groups (n = 10). For group-NI, 30-gauge nickel-titanium irrigation needle was used. During irrigation with every 5mL, needle was moved in-and-out with 4-mm amplitudes. EndoActivator and ultrasonic tip were used for group-EA and group-UT respectively for 20 seconds after every 5mL irrigation using needle. Then the weight was measured again to calculate the weight of residual remnants. The data were analyzed by one-way ANOVA and Duncan's post-hoc test at a significance level of 95%. Results: The weight of the residual medicaments were $3.62{\pm}0.81mg$, $2.84{\pm}0.28mg$, and $2.73{\pm}0.90mg$ for group-NI, -EA, and -UT, respectively. Group-EA and group-UT had no significant differences to remove intracanal medicament and left significantly less amount of paste than group-NI (p < 0.05). Conclusions: Under the controlled conditions of this study, the sonic activation and PUI have similar mechanical efficacy for removing intracanal medicament.