• Title/Summary/Keyword: Needle aspiration biopsy

Search Result 304, Processing Time 0.025 seconds

Diagnostic Correlation and Accuracy Between Fine Needle Aspiration Cytology and Histopathologic Examination (세침흡인 세포검사와 조직검사의 진단 일치율 및 정확도에 대한 조사)

  • Sohn, Jin-Hee;Chae, Seoung-Wan;Cho, Eun-Yoon;Kim, Eo-Jin
    • The Korean Journal of Cytopathology
    • /
    • v.14 no.2
    • /
    • pp.53-59
    • /
    • 2003
  • Fine needle aspiration cytology (FNAC) has been known as a very sensitive and effective method for preoperative diagnosis. We studied cases preoperatively diagnosed by FNAC and confirmed by the histopathologic examination to define the effectiveness of FNAC. A total of 567 cases including breast, thyroid gland, lymph node, and soft tissue confirmed histologically after FNAC were enrolled, among 2,844 FNAC cases from January 1996 to March 2000. Overall sensitivity and specificity of FNAC were 93% and 100%, respectively. Sensitivity and specificity of FNAC by sites or organs were 91% and 100% in breast, 100% and 100% in thyroid, 97% and 100% in lymph node, and 71% and 100% in soft tissue, respectively. Nine cases showed diagnostic discrepancy; eight cases of sampling error and one case of interpretation error. Five cases, diagnosed as fibrocystic change at FNAC but invasive ductal carcinoma after the histopathologic examination, were categorized as sampling error due to the presence of diffuse fibrosis or deep seated location. One case of breast, diagnosed descriptively as atypical ductal and stromal cells suggesting invasive ductal carcinoma at FNAC but malignant phyllodes tumor histologically, was categorized as interpretation error. Other cases of sampling errors were two cases of soft tissue, a case of lymph node, and a case of salivary gland.

Accuracy of Fine Needle Aspiration Cytology of Salivary Gland Lesions: Routine Diagnostic Experience in Bangkok, Thailand

  • Sudarat, Nguansangiam;Somnuek, Jesdapatarakul;Nisarat, Dhanarak;Krittika, Sosrisakorn
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1583-1588
    • /
    • 2012
  • Fine needle aspiration (FNA) cytology is well accepted as a safe, reliable, minimal invasive and cost-effective method for diagnosis of salivary gland lesions. This study evaluated the accuracy and diagnostic performance of FNA cytology in Thailand. A consecutive series of 290 samples from 246 patients during January 2001-December 2009 were evaluated from the archive of the Anatomical Pathology Department of our institution and 133 specimens were verified by histopathologic diagnoses, obtained with material from surgical excision or biopsy. Cytologic diagnoses classified as unsatisfactory, benign, suspicious for malignancy and malignant were compared with the histopathological findings. Among the 133 satisfactory specimens, the anatomic sites were 70 (52.6%) parotid glands and 63 (47.4 %) submandibular glands. FNA cytological diagnoses showed benign lesions in 119 cases (89.5 %), suspicious for malignancy in 3 cases (2.2 %) and malignant in 11 cases (8.3%). From the subsequent histopathologic diagnoses, 3/133 cases of benign cytology turned out to be malignant lesions, the false negative rate being 2.2 % and 1/133 case of malignant cytology turned out to be a benign lesion, giving a false positive rate was 0.8%. The overall accuracy, sensitivity, specificity, positive predictive value and negative predictive value were 97.0% (95% CI, 70.6%-99.4%), 81.3% (95% CI, 54.4%-96.0%), 99.1% (95% CI, 95.4%-100%), 92.9% (95% CI, 66.1%-99.8), 97.5% (95% CI, 92.8%-99.5%), respectively. This study indicated that FNA cytology of salivary gland is a reliable and highly accurate diagnostic method for diagnosis of salivary gland lesions. It not only provides preoperative diagnosis for therapeutic management but also can prevent unnecessary surgery.

Fine Needle Aspiration Cytologic Findings of Inflammatory Breast Diseases (유방 염증성 질환의 세침흡인소견)

  • Yoon, Hye-Kyoung;Park, Seol-Mi;Kang, Mi-Sun;Yang, Young-Il;Kim, Chan-Hwan
    • The Korean Journal of Cytopathology
    • /
    • v.6 no.2
    • /
    • pp.156-162
    • /
    • 1995
  • Fine needle aspiration of the breast is an important diagnostic tool in malignant lesions, but is also useful in differentiation of inflammatory breast diseases mimicking carcinoma clinically and radiologically. Recently, the authors have experienced eight biopsy-proven cases of chronic inflammatory diseases of the breast, which consisted of 4 cases of duct ectasia, 2 cases of fat necrosis, and a case of tuberculous mastitis and granulomatous mastitis respectively. Their cytologic features mainly based on the components and the relative frequency of inflammatory cells were evaluated for differential diagnosis of chronic inflammatory breast diseases. The results are as follows; 1. In cases of duct ectasia, varying amount of neutrophils, mononuclear leukocytes, histiocytes and multinucleated giant cells were intermixed with benign epithelial cell clusters. 2 Abundant fat tissue fragments were diagnostic for fat necrosis. Histiocytes and mononuclear cells were main components but not rich, and neutrophils and giant cells were infrequently observed. 3. Characteristic granulomas composed of epithelioid cells, mononuclear leukocytes and Langhans' type giant cells and lymphocytic infiltrates were conspicuous in tuberculous mastitis, and occasionally neutrophils, necrotic materials and epithelial cell clusters were found 4. In granulomatous mastitis, epithelioid cell granulomas were also noted but numerous neutrophils and histiocytes were intermingled within or outside the granulomas.

  • PDF

Diagnostic Usefulness and Limitation of Fine Needle Aspiration Cytology of Lymph Node - Analysis of 176 Cases Confirmed by Biopsy - (림프절 세침흡인 세포검사의 진단적 유용성과 한계 - 생검으로 확진한 176 예의 분석 -)

  • Kim, Hee-Sung;Kim, Dae-Soo;Oh, Young-Lyun;Ko, Young-Hyeh;Ree, Howe-J.
    • The Korean Journal of Cytopathology
    • /
    • v.10 no.1
    • /
    • pp.35-42
    • /
    • 1999
  • The accuracy of fine needle aspiration cytology(FNAC) of the lymph node was investigated through a review of 176 FNAC cases and the corresponding biopsies. We chose 157 FNAC cases after the exclusion of 19 inadequate ones. Sensitivity of malignancy was 94.0%, specificity 100%, false negativity 6.0%, and false positivity 0.0%. The overall diagnostic accuracy was 96.8%. Sensitivity of metastatic carcinoma was 98.0% and that of malignant lymphoma was 87.9%. False negative cases included one metastatic carcinoma and four malignant lymphomas. The aspirates of metastatic carcinoma with false negativity exhibited a diffuse smear of keratin debris without viable cells, which led to the difficulty in differentiation from benign epithelial cyst. The cases of malignant lymphoma with false negative diagnosis were two Hodgkin diseases, one Lennert's lymphoma, and one peripheral T cell lymphoma in the histologic sections. On the analysis of 39 cases of tuberculosis, 17 cases(43.6%) were diagnosed as tuberculosis, 4(10.3%) as granulomatous lymphadenitis, 3(7.7%) as necrotizing lymphadenitis, and 15(38.5%) as reactive hyperplasia or pyogenic inflammation. Sensitivity of tuberculosis was 53.9%. In conclusion, lymph node FNAC is an excellent non-invasive diagnostic tool for the diagnosis of metastatic carcinoma. The diagnostic accuracy of malignant lymphoma could be improved with flow cytometry or polymerase chain reaction for antigen receptor genes. For the FNAC diagnosis of tuberculosis, AFB stain, culture, and PCR would be helpful as adjuvant techniques.

  • PDF

A Study of Diagnostic Value on Fine Needle Aspiration Cytology of the Breast Masses (유방종괴의 세침흡인세포학의 진단적 가치에 관한 연구)

  • Kim, Dong-Won;Lee, Dong-Wha
    • The Korean Journal of Cytopathology
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1993
  • This study was performed in order to evaluate the accuracy and the usefulness of the fine needle aspiration cytology (FNAC) on the breast lesions, to compare the FNAC findings between fibroadenoma and fibrocystic disease, and to determine the accuracy of cytologic Black's nuclear grading. The subjects in this study were 110 cases of FNAC, later confirmed by biopsy, between January 1988 and December 1991. The results are as follows ; 1 Comparison between the results of the FNAC and the histologic findings revealed that FNAC had a sensitivity of 96.6%, a specificity of 100%, a false negative rate of 3.4% a false positive rate of 0.0%, and an overall diagnostic accuracy of 98.2%. 2 Semi-quantitative evaluation of epithelial celluarity, stroma, and naked nuclei in the smears of aspirate showed high celluarity in 56.7% of the aspirates from fibroadenoma and in 0% of those from fibrocystic disease. Abundant stroma was found in 46.7% of the fibroadenoma and none of fibrocystic disease. Numerous naked nuclei were found in 60% of the fibroadenoma and 4.5% of the fibrocystic disease. The overall diagnostic accuracy was 98% 3. In order to determine the accuracy of Black's nuclear grading of FNAC on breast carcinoma, we retrospectively studied 38 cases of ductal carcinomas diagnosed by FNAC with subsequent histologic confirmation. The concordance rate with histology was 94.7%. These results suggest that FNAC of breast is a diagnostically accurate method, and provide for the preoperative differential diagnosis between fibroadenoma and fibrocystic disease. Our results also suggest that the evaluation of nuclear grading of FNAC can predict clinical outcome and decide the way of management of breast cancer.

  • PDF

Cytologic Findings of Fine Needle Aspiration Biopsy of 23 Schwannomas (슈반세포종 23예의 세침흡인 세포검사에 대한 세포소견)

  • Chang, Sun-Hee;Joo, Mee;Kim, Han-Seong
    • The Korean Journal of Cytopathology
    • /
    • v.19 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • In an attempt to better define the cytologic characteristics of schwannomas, we have reviewed aspirates and corresponding histologic sections from 23 schwannomas. Of this number, the original cytologic diagnoses were: schwannoma in 14 cases (61%), benign soft tissue tumor in 2 cases (9%), and insufficient specimen in 7 cases (30%). The cytologic findings common to all cases of schwannoma included fragments of tightly cohesive fascicles with variable cellularity and corresponding Antoni type A area. The Antoni type B area, consisting of scattered spindle cells and some histiocytes and lymphocytes against a myxoid background, was seen in 14 cases. Fibrillary stroma was seen in 12 cases. The tumor cells had spindle- or ovalshaped nuclei, with pointed ends and indistinct cell borders. Nuclear palisading was seen in 10 cases, and distinctive Verocay bodies were seen in 5 cases. In ancient schwannomas, there were no Verocay bodies. Most schwannomas have distinct cytomorphologic features that allow correct diagnosis. The major problem with fine needle aspiration cytology of these tumors is the high frequency of poor cellularity, particularly in lesions with cystic degeneration. Of 7 cases with insufficient specimen, 4 showed marked cystic changes and 1 showed marked hyaline changes on histologic sections. In conclusion, we believe that if cytopathologist reminds the situation such as cystic degeneration or hyaline degeneration, the correct diagnosis of the schwannoma will be easily made.

Incidence and Risk Factor of Pneumothorax After Percutaneous Fine Needle Aspiration Biopsy of the Lung (경피폐세침흡인생검시 기흉의 발생빈도와 위험인자)

  • Choi, Cheon Woong;Yoo, Jee Hong;Chin, Hyoun Jung;Park, Myoung Jae;Kang, Hong Mo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.6
    • /
    • pp.628-637
    • /
    • 2004
  • Background : Percutaneous needle aspiration biopsy(PNAB) of the lung is a safe procedure for diagnosis of various pulmonary diseases but complications such as pneumothorax can occasionally develop. We reviewed the complications arising after PNAB and analysed the risk factors of pneumothorax. Method : We collected data by reviewing medical records and radiographic studies of 403 patients who underwent PNAB of the lung between 1988 and 2002 and analyzed the risk factors of pneumothorax. Result : The incidence of complication was 12.9%, 48 patients with pneumothorax and 4 patients with mild hemoptysis. Among the 48 pneumothorax patients, 35 patients showed mild(<20%) and was treated by only oxygen supply, 11 patients had severe pneumothorax(>50%) and chest tube insertion was done and 2 patients were treated by needle aspiration. As the results of multivariate analysis, size and location of lesion, location of approach, diagnosis of lesion showed no significant relationship, while age and gender of patients(p<0.05) and the depth of approach(p<0.001) were significantly related to pneumothorax. Smoking amount(p<0.001) as well as the smoking history(p<0.005) were also significantly related and the examiner displaying various incidence of pneumothorax from 4.0% to 23.1% among individuals also was a significant independent risk factor(p<0.05). While the average depth of approach for 13 patients treated by chest tube insertion or needle aspiration was $8.2{\pm}1.2cm$, 35 patiens treated only by oxygen supply was $6.7{\pm}1.6cm$ suggesting that the depth of approach was lead to a severe pneumothorax. Conclusion : The independent risk factors of pneumothorax, the most common complication after PNAB, are age and gender of patients, depth of approach, examiner of procedure, smoking history and smoking amount.

Fine Needle Aspiration Cytology in Bone and Soft Tissue Tumor (골 및 연부 조직 종양에서의 미세 침 흡입 세포 검사)

  • Lee, Soo-Yong;Jeon, Dae-Geun;Lee, Jong-Seok;Kim, Sug-Jun;Cho, Kyung-Ja;Oh, Hyung-Ho;Park, Min-Hyo;Park, Hyun-Soo;Jang, Jin-Dae
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.33-37
    • /
    • 1996
  • From January 1994 to August 1995 we performed 270 cases of fine needle aspiration cytology for bone and soft tissue lesions. Among them 137 cases were diagnosed histologically. Sixty-seven cases were benign and 70 cases were malignant. We analysed these on the aspect of sensitivity, specifity, positive predictive value, negative predictive value of the cytologic examination. Malignant cases consisted of bone tumor 29 cases; soft tissue tumor 25 cases; and metastatic tumor 16 cases. The sensitivity and specifity of the aspiration cytology for malignant tumor were 67.8% and 97%, respectively. The positive and negative predictive value of aspiration cytology were 97.4% and 72.7%, respectively. Among them 40 cases were primary bony lesions; 14 benign lesions, 26 malignamt bone tumors. Sensitivity of aspiration cytology for these primary bony lesion was 90%(18/20) and its specifity was 100%(13/13). Three cases showed atypical cells in cytology but with biopsy we could find them as one benign and two malignancies. Two cases of manignancy showed negative result in cytology; one was parosteal sarcoma of proximal femur and the other was osteosarcoma of proximal tibia which was biopsied already at other hospital. Although the overall sensitivity and specifity for malignant bone and soft tissue tumors were relatively low and not so predictable, the fine needle aspiration cytology for primary bony lesion was useful in the differential diagnosis of benign or malignancy.

  • PDF

Accuracy, Sensitivity and Specificity of Fine Needle Aspiration Biopsy for Salivary Gland Tumors: A Retrospective Study from 2006 to 2011

  • Silva, William P P;Stramandinoli-Zanicotti, Roberta T;Schussel, Juliana L;Ramos, Gyl H A;Ioshi, Sergio O;Sassi, Laurindo M
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.4973-4976
    • /
    • 2016
  • Objective: This article concerns evaluation of the sensitivity, specificity and accuracy of FNAB for pre-surgical diagnosis of benign and malignant lesions of major and minor salivary glands of patients treated in the Department of Head and Neck Surgery of Erasto Gartner Hospital. Methods: This retrospective study analyzed medical records from January 2006 to December 2011 from patients with salivary gland lesions who underwent preoperative FNAB and, after surgical excision of the lesion, histopathological examination. Results: The study had a cohort of 130 cases, but 34 cases (26.2%) were considered unsatisfactory regarding cytology analyses. Based on the data, sensitivity was 66.7% (6/9), specificity was 81.6% (71/87), accuracy was 80.2% (77/96), the positive predictive value was 66,7% (6/9) and the negative predictive value was 81.6% (71/87). Conclusion: Despite the high rate of inadequate samples obtained in the FNAB in this study the technique offers high specificity, accuracy and acceptable sensitivity.

Metastatic Melanoma Mimicking a Papillary Carcinoma of the Thyroid in Fine Needle Aspiration Cytology -A Case Report- (갑상샘 유두암을 닮은 전이성 흑색종의 세침 흡인 세포 소견 -1예 보고-)

  • Hong, Young-Ok;Suh, Jae-Hee;Cha, Hee-Jeong;Choi, Hye-Jeong;Kim, Young-Min
    • The Korean Journal of Cytopathology
    • /
    • v.18 no.2
    • /
    • pp.161-164
    • /
    • 2007
  • Metastasis to the thyroid gland is very rare in clinical practice. We recently encountered a 65-year-old woman who presented with a large thyroid nodule that mimicked the cytologic features of a papillary thyroid carcinoma on fine needle aspiration biopsy (FNAB). Although initially diagnosed as a papillary thyroid carcinoma, a thorough clinical work-up revealed multiple lesions in the bones, liver, and nasal cavity, which were confirmed as metastases of a malignant melanoma. Despite a thorough physical examination, however, the primary skin lesion could not be identified. Although FNAB shows a high degree of accuracy in diagnosing primary thyroid tumors, it is less accurate in diagnosing metastases to the thyroid gland. A thorough clinical history with appropriate immunohistochemical staining assays is necessary for the accurate diagnosis of metastatic malignant melanoma.