The effects of sharpness of needle electode on the spark voltage in needle-plane and needle-needle spark gaps at atmospheric pressure was investigated experimentaly in this paper. As the sharpness of needle electrode increases, the spark voltage increases, and the rate of increase is greater in needle-needle electrode than in needle-plane gap. the effects of sharpness is greater in small gap length. These characteristics can be explained by the electric field strength at the needle tip depending on the sharpness of needle, electro-static capacity between the electrodes, and the polarity effect in needle-plane gap. These experimental results will be able to play an important roles on the design of needle-needle gap as high voltage measurement devices and of needle-plane gap as high voltage rectifier equipments.
A study .to identify an occupational hazards for hospital working health care providers from needle stick injury as an occupational hazards of health care providers in hospital and prevention A survey of 2430 health professionals (2184 nurses, 182 doctors, and 64 Lab technicians) was conducted to describe and provide information about 1) the experience of needle stick. 2) the number of needle stick, 3) the treatment after needle stick. 3) the situation of needle stick, 4) the report of needle stick, 5) the cause of needle stick, 6) the discard method of used needles, and 7) how to worry about getting infection disease after needle stick. Data were collected using questionnarires constructed by the authors and tested by a pilot study. Results of the study showed that 96.7% of the sample had an experience of needle stick (96.8% of the nurses, 96.7% of the doctors, and 92.2% of Lab technicians). Seventy seven percent of the sample experienced less than 10 needle sticks, 19% of the sample experienced 11 to 20 needle sticks, and the rest of the sample experienced more than 20 needle sticks. The situations where needle sticks occurred include intrvenous injection (36.5%), intramuscular injection (21.6%), blood withdraw (17.8%), and preparation(11.8%). The study showed that needle sticks (67.5%) usually occurred after client treatment. Health professionals used recapping method (55%) after they used needles. Needle sticks were predominantly caused by the carelessness of health professionals (61%), After needle sticks, 88.2% of the sample subjects treated needle sticks using disinfection technique by themselves. Most of health professionals (92.6%) did not report the accident. and 95.6% of them did not receive any test or further treatment. After needle sticks, 87.8% of nurses, 83.6% of doctors, and 96.6% of lab technicians worried about hepatitis infection. 'Health professionals also worried about AIDS infection, tetanus, venereal infection, and skin injury. These findings suggest that health professionals are at high-risk of needle stick and fail to report needle stick accidents. They should pay more attention to needle stick in order to avoid unwanted infection.
The heat of sewing needle is generated through the friction during the needle penetration into and withdrawal from fabrics. Therefore, effects of sewing condition for knitted fabric on the heat generation of needle was examined. The needle size was not the large influence factor of heat generation of needle but the needle point shape significantly affects needle temperature. And the super needle coated with fluoro resin had more effect on reducing the heat of needle. The decrease of sewing speed and the increase of stitch rate had more effect on the reduction in needle temperature. Also the Influence of a sewing thread on the needle temperature was very large compared with bare needle. As expected, an increase in the number of fabric layers result in higher needle temperature.
Jared Joseph Tuttle;Andrew Doran Davidson;Gregory Kent Tuttle
Journal of Dental Anesthesia and Pain Medicine
/
제23권5호
/
pp.281-285
/
2023
Background: Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide. Methods: Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded. Results: The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504). Conclusion: Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.
Objectives : In this study, we intended to make the foundation of the development of acupuncture tissue model as comparing the needle sensation of six kinds of tissue models and Zusanli ($ST_{36}$) with the needle force measurement system. Methods : When practitioners did twisting-rotating acupuncture needle manipulation after inserting the needle into six kinds of tissue models, they quantified the similarity sense to the sensation of Zusanli ($ST_{36}$) with the NRS (Numeric Rating scale). As needle force measurement system did twisting-rotating Acupuncture needle manipulation after inserting needle into Zusanli ($ST_{36}$) of human and six kinds of tissue models, it can calculate the coefficient of viscosity by measuring the torsion friction. We compare the NRS of practitioners' needle sensation to the coefficient of viscosity of needle force measurement systems. Result : As practitioners' NRS assessment to quantify needle sensation, apple and cucumber showed 70% similarity to Zusanli ($ST_{36}$). As needle force measurement system's coefficient of viscosity, apple and cucumber's coefficient of viscosity were similar to Zusanli ($ST_{36}$)'s. Conclusions : In this study, We compared the practitioners' needle sensation of Zusanli ($ST_{36}$) and six kinds of tissue models with needle force measurement system that can quantify the needle sensation. As the result, we concluded that practitioners' needle sensation is similar to measured needle sensation. It seems that the acupuncture practice model implementing the needle sensation to specific acupuncture points can be built based on the system in this study.
Kim, Jae Yun;Kim, Soo Nyoung;Park, Chulmin;Lim, Ho Young;Kim, Jae Hun
The Korean Journal of Pain
/
제32권1호
/
pp.39-46
/
2019
Background: Lumbosacral transforaminal epidural injection (TFEI) is an effective treatment for spinal disease. However, TFEI may have several types of complications, some of which can be attributed to intravascular injection. We reviewed studies to compare the intravascular injection rate among different needle types. Methods: We searched the literature for articles on the intravascular injection rate among different needle types used in TFEI. The search was performed using PubMed, MEDLINE, the Cochrane Library, EMBASE, and Web of Science. Results: A total of six studies comprising 2359 patients were identified. Compared with the Quincke needle, the Whitacre needle reduced the intravascular injection rate (OR = 0.57, 95% CI = [0.44-0.73], P < 0.001). However, compared with the Quincke needle, the Chiba needle did not reduce the intravascular injection rate (OR = 0.80, 95% CI = [0.44-1.45], P = 0.46). In one study, the intravascular injection rate using a blunt-tip needle was lower than that using a sharp needle. In another study, the Whitacre and the blunt-tip needle have similar intravascular injection rates, while, the catheter-extension needle showed a reduced intravascular injection rate. Conclusions: This meta-analysis showed that the Whitacre needle reduced the intravascular injection rate as compared with the Quincke needle, but failed to establish that the Chiba needle can decrease the intravascular injection rate in TFEI. Moreover, the blunt-tip needle can reduce the intravascular injection rate compared with the Quincke needle, and the catheter-extension needle can reduce the intravascular injection rate compared with the Whitacre and the blunt-tip needle.
Background: The phrase "Nine Needles" refers to the 9 types of acupuncture needles describing their shapes, sizes, and uses in Huangdi's Internal Classic Ling-shu. The aim of this study was to present 3D illustrations of the "Nine Types of Needles" based on Huangdi's Internal classic Ling-shu, taking into consideration the conformation and application of the Nine Needles. Methods: Sketches of the "Nine Needles" were based on references to those needles cited in Huangdi's Internal Classic Ling-shu, the Great Compendium of Acupuncture and Moxibustion, and the Golden Mirror of Medicine. The computer programs Creo 3.0, Keyshot 5, Adobe Photoshop CS5, and Adobe Illustrator CS5 were used for 3D modelling and visualization. Results: Based on a review of Huangdi's Internal Classic Ling-shu, illustrations of the Spade needle, Round-Pointed needle, Pressure needle, Sharp-Edged needle, Sword-Shaped needle, Round-Sharp needle, Fine needle, Long needle, and Large needle, 3D models were created. The Spade needle had a sharp, large head, the Round-Pointed needle had an egg-shaped tip, and the Pressure needle had a blunt head like a grain of millet. The Sharp-Edged needle had a sharp blade with a triangular edge for bloodletting. The Sword-Shaped needle resembled a sword. The Round-Sharp needle resembled a horse's tail. The Fine needle and the Long needle had sharp points and thin bodies. The Large needle had a cylindrical shaft and rounded tip. Conclusion: This study demonstrated that 3D illustrations could be generated for the Nine Needles according to the descriptions and figures provided in the ancient literature.
Objectives : A dermal needle is one of the therapeutic method by stimulating or tapping on the certain points of skin. Recently, roller or stamp-needle have been applied to various diseases in combination with microneedle technology. In this study, we analyzed the trend of roller and stamp-needle in Korean patent. Methods : Electronic search for Korean patent of roller or stamp needle was performed in Korea Intellectual Property Right Information Service database to April, 2019. Results : Sixty seven patents (51, roller-needle; 15, stamp-needle; 1, both types of needle) met the inclusion criteria. According to patent details, 34 of 67 patents were skin stimulation, 14 patents were intended to increase the efficiency of drug delivery through skin stimulation, 16 patents combined skin stimulation with technologies such as electrode or high frequency, and three patents applied both electrode or high frequency stimulation, and drug application as well as physical skin stimulation. Each of these patents aims to increase the efficiency of the needle manufacturing process (n=24), to facilitate the use of tools or to increase the efficiency of the technology (n=61), or to increase the technical skill of the needle itself (n=23). Conclusions : This study confirms that technological advances were being made by combining various types of stimuli to dermal needle and there have been attempts to expand the scope of drug delivery in terms of application of dermal needle. In the future, more research and development is needed in order to apply the dermal needle to modern technology.
Objectives : We were studied the retaining needle to offer basic materials for the study of it. methods: To study the retaining needle, we were reviewed the ancient, the present text and the thesis. Results: 1. There are many ways form general acupuncture technique to needle-embedding therapy by the spending time of the retaining needle. 2. The method retaining needle is divided into Active method of the retaining needle(動留針法) and Passive methoid of the retaining needle(靜留針法) by the existence of Qi-promoting. 3. In case of Deficiency Syndrome, protracted discase, dolorific disorder, convulsive disorder, and Cold Syndrome, the spending time of the retaining needle takes longer, in case of Heat Syndrome and exterior Syndrome, the spending time of the retaining needle takes shorter. 4. In case of acute disease and attack of chronic disease, we can use Active methoid of the retaining needle(動留鍼法) with retaining needle for a long time, in case of chronic disease, we can use Passive methoid of the retaining needle(靜留針法). 5. In case of Young people, a man in the prime of life, and a people who can stand the stimulation of needle, we can make the spending time of the retaining needle be longer and use Active methoid of the retaining needle(動留針法), but in case of a baby and a weak people, we had better shorten the spending time of the retaining needle or not do it. 6. The spending time of the retaining needle must be shorter in spring and summer, must be longer in fall and winter. 7. The spending time of the retaining needle is various by acupuncture point. 8. When the spending time of the retaining needle is too longer, we can injure Vital-qi of a patient, otherwise in opposite situation, Pathogenic is stagnated so pathogenic stage is repeated.
Objectives : The warm needling technique is the method combining the effects of acupuncture needle with those of moxibustion. We need to standardize the characteristics of the warm needling technique, in order to get more systematic and objective results in operation and effects and then get more clinical abilities in these fields. Methods : In this study, using labview system on the warm needling technique, we measured and compared partial temperature changes according to the kind of needle. We studied relations of moxa cones of various sizes with the peak combustion temperature. Results and Conclusions: When we measured the warm needling's partial temperature, temperature measured at 1 and 2 cm below the head, according to the kind of needle, gold needle got the higher result on the peak than SS304 stainless steel needle. In the case of combustion of the moxa cones, cones weighing 0.4 g and 0.8 g, respectively, and the apex ignition method with gold needle showed the higher result than the apex ignition method with stainless steel needle, when we measured the effective stimulus time at 2 cm below the head and the mean temperature during the effective stimulus time. Although more research to standardize the characteristics of the warm needling technique will be needed, we suggest, according to these results, that warm needling of gold needle combined with moxa cone of 0.4 or 0.8 g is effective.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.