• Title/Summary/Keyword: Nebulizer

Search Result 70, Processing Time 0.02 seconds

Signal compensation by the light scattering of sample aerosols in ICP-AES (ICP-AES에서 에어로졸의 광산란에 의한 신호의 보정)

  • Yeon, Pyung-Hum;Pak, Yong-Nam
    • Analytical Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.223-229
    • /
    • 2012
  • Analytical signal from ICP was compensated by the light scattering of sample aerosols. Reference scattering signal was generated by a He-Ne or diode laser, monitored for the amount of aerosol producing and used for the compensation of analytical signals. The result showed that significant improvement in precision could be achieved for the short-term signal (within 1 minute) from 3.4% to 0.9% RSD in signal and 14.9% to 4.2% for the long-term (10 minutes) for Be, Pb and Co. This method is very useful not only for the pulse type but for continuous type signals especially when a nebulizer is unstable. To improve long-term precision, higher stability is required in the scattering cell and detector as well as the reduction of noise from the line between a nebulizer and plasma.

A Case Report of Hunter Syndrome (Hunter 증후군 환아 증례 1례 보고)

  • Kim, Yoon-Young;Seo, Young-Min;Kim, Jang-Hyun
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.10
    • /
    • pp.77-85
    • /
    • 2008
  • Objective : The purpose of this study is to report a case that has an important meaning as a result of treating Hunter syndrome patient with oriental medicine for elevation of quality of life and continuous health care. Methods : The patient complained of abdominal dropsy, abdominal pain, constipation, frequent gases and the common cold. So we treated him with herbal medicine, acupuncture, infra red, laser, CEP nebulizer, aroma massage and cupping. Results : After treatment, the girth of abdomen didn't increse any more and abdominal pain, constipation, frequent gases and common cold were improved. Conclusion : This study shows that oriental medicine can elevate the Hunter syndrome patient's quality of life with continuous heath care and treatment for chief complaint. The further study is needed with more cases.

  • PDF

A Retrospective Study of Chronic Sinusitis in Children Treated by Korean Medicine - Using Paranasal Sinus Water's View (한방 요법으로 치료된 소아 만성 부비동염 33례에 대한 후향적 연구 - 부비동 단순 X선 촬영을 이용하여)

  • Choi, Sun Hee;Park, Eun Jung
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.69-81
    • /
    • 2019
  • Objectives The purpose of this study is to examine 33 cases of chronic sinusitis in children who were treated with Korean medicine. Methods Herbal medicine, acupuncture, and nebulizer and laser therapy were used to treat chronic sinusitis, and a plain radiography (paranasal sinus water's view) was used to confirm improvement of the children's sinusitis. Then, the data was classified by sex, age, frequency and duration of common cold, severity of sinusitis, duration of treatment, pattern identification and so on. Results There were 72.7% boys and 27.3% girls. The average age of children is $4.48{\pm}2.18years$. 70% of the children had common cold more than once a month, and 85.1% of the children from the study group had common cold lasting more than a week. The sinusitis severity score ranged from 10 to 200. 81.8% were more than 100. Duration of the treatment was $157.21{\pm}83.4day$, duration of herbal medicine treatment was $79.3{\pm}31.23day$, rate of herbal medicine was $62.12{\pm}29.21%$. The frequency of acupuncture, nebulizer and laser therapy ranged from 1 time to 11 times but was much lower than expected. Conclusions 33 cases of chronic sinusitis in children were treated with Korean medicine, and cure of the illness was confirmed by PNS water's view, and clinical characteristic of the patients with chronic sinusitis was analyzed.

Design of Ultrasonic Nebulizer for Inhalation Toxicology Study of Cadmium with Application of Engineering Methodology and Performance Evaluation with Light-Scattering Photometer (공학적 기법을 응용한 카드뮴의 흡입독성 연구를 위한 초음파 네뷸라이져의 설계 그리고 광산란 광도계를 이용한 성능평가)

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.464-471
    • /
    • 2002
  • Author applied several engineering methodologies to classical ultrasonic nebulizer to cope with it's demerits. After several trials and errors, we got the several meaningful results. To evaluate the modified ultrasonic nebulizer for inhalation toxicology of cadmium, author used light-scattering photometer. This paper is the one part of inhalation exposure systems for inhalation toxicology study of cadmium. According to the testing conditions, source temperature 50℃ and inlet-duct band temperature 150℃, aerosol generation results for sodium chloride and cadmium chloride were as followings: Coefficients of variation(CV) of sodium chloride and cadmium chloride for repeated trials were 3.38 and 4.77 for 10g, 2.47 and 5.02 for 5g, and 4.70 and 2.98 for 2.5g. All the CVs were within 10% of acceptance variability. Count Per Minute(CPM) changes of NaCl and CdCl₂ for 5 repeated trials were similar. CPM ratios of CdCl₂/NaCl were 1.13 for 10g, 0.76 for 5g, and 1.06 for 2.5g. Relative aerosol generation of cadmium chloride to sodium chloride was the highest in 10g. Efficiency increases of 24.50% for 5g NaCl, 14.91 % for 2.5g NaCl, and 16.48% for 2.5g CdCl₂ with respect to theoretical efficiency were observed but 0.04% efficiency decrease was observed in 5g CdC₂. According to the modifications of source temperature(20, 50, 70℃) and inlet-duct band temperature(20, 50, 100, 150, 200℃), aerosol generation results for NaCl and CdCl₂ were as followings: CPM trends for each quantity excepting 10g NaCl in inlet-duct band temperature 200℃ were similar, and the highest CPM was observed in source temperature 70℃ to each inlet-duct band temperature. The highest CPMs to 10, 5, and 2.5g NaCl were observed in source temperature 70℃ and inlet-duct band temperature 20℃. Aerosol generation of cadmium chloride was increased with the higher source temperature, excepting inlet-duct band temperature 200℃. The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this trend was similar to NaCl aerosol generation The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this result was similar to NaCl aerosol generation. Observed efficiencies of 5 and 2.5g NaCl were similar to ifs theoretical efficiency but -3.08% efficiency decrease of 5g CdCl₂, 17.47% efficiency increase of 2.5g CdCl₂ were observed. CPM ratio of CdCl₂/NaCl of 10g was different to 5 and 2.5g, and 2.5g ratio was higher than 5g ratio. In conclusion, to get maximum aerosol generation for NaCl and CdCl₂ will be the conditions that set the appropriate inlet-duct band temperature for each materials and increase the source temperature. Sodium chloride can be used to evaluate the performance and predict the concentration for cadmium aerosol in aerosol generator and inhalation exposure system.

A Case Report of Hunter Syndrome (Hunter 증후군 환아 증례 1례 보고)

  • Kim, Yoon-Young;Seo, Young-Min;Kim, Jang-Hyun
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.145-152
    • /
    • 2007
  • Objectives The purpose of this study is to report a case that has an important meaning as a result of treating. Hunter syndrome patient with oriental medicine for elevation of quality of life and continuous health care. Methods The patient had abdominal dropsy, abdominal pain, constipation, frequent gases and the common cold, so we treated him with herbal medicine, acupuncture, infra red, laser, CEP nebulizer, aroma massage and cupping. Results After the treatment, the girth of abdomen didn't Increase any more, and abdominal pain, constipation, frequent gases and common cold were improved. Conclusions This study shows that oriental medicine can elevate the Hunter syndrome patient's quality of life with continuous heath care and treatment for major problem. For more accurate studies, further studies would be needed with more cases.

  • PDF

Two Cases Report of Oriental Medical Therapy for Sinusitis in the Overweight Children (과체중 소아의 부비동염에 대한 한방 치료 2례)

  • Jang, Jung-Hee;Park, Jun-Hong
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.29 no.2
    • /
    • pp.149-160
    • /
    • 2016
  • Objectives : The purpose of this clinical study is to investigate effectiveness of oriental medical treatment for sinusitis in the two overweight children. Methods : This study was performed for two 5-years old of age and overweight (BMI>90th percentile) children with sinusitis who visited the clinic. The symptoms of sinusitis are rhinorrhea, poor sleep due to nasal congestion, cough, sputum. Oriental herb medicines(Kami-Hyunggyeyungyotang and Kami-Cheonggeumganghwatang), moxibustion, nebulizer and aroma nasal spray were treated to two children. The progress of treatment for sinusitis was evaluated through the subjective symptoms and endoscope inspection. Results & Conclusions : After oriental medical treatment, the subjective symptoms and endoscope inspection were improved in all two children. Our results suggested that oriental medical treatment have effective to alleviate the symptoms of sinusitis in overweight children.

A Case Report of Medically Unexplained Dyspnea (원인불명의 호흡곤란을 호소한 증례 보고 1례)

  • Kim, Hyun-Ji;Lee, Hai-Ja;Park, Eun-Jung
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.21 no.3
    • /
    • pp.97-107
    • /
    • 2007
  • Objectives The purpose of this study is to report a case showed significant consult in treating Idiopathic chronic hyperventilation patient with oriental medicine. Methods The patient had suffered from dysypnea for 7 months, so we treated her with herbal medicine, acupuncture, laser, CEP nebulizer and cupping. Results and Conclusions This study shows that oriental medicine works for treating Idiopathic chronic hyperventilation. For more accurate studies, further studies are needed with more clinical cases.

  • PDF

Distribution of Rare Earth Elements and Their Applications as Tracers for Groundwater Geochemistry - A Review

  • Hwang, Heejin;Nyamgerel, Yalalt;Lee, Jeonghoon
    • Journal of the Korean earth science society
    • /
    • v.42 no.4
    • /
    • pp.383-389
    • /
    • 2021
  • Several studies investigating the behavior and environmental distribution of rare earth elements (REEs) have been reviewed to determine the geochemical processes that may affect their concentrations and fractionation patterns in groundwater and whether these elements can be used as tracers for groundwater-rock interactions and groundwater flow paths in small catchments. Inductively coupled plasma-mass spectrometry (ICP-MS), equipped with an ultrasonic nebulizer and active-film multiplier detector, is routinely used as an analytical technique to measure REEs in groundwater, facilitating the analysis of dissolved REE geochemistry. This review focuses on the distribution of REEs in groundwater and their application as tracers for groundwater geochemistry. Our review of existing literature suggests that REEs in ice cores can be used as effective tracers for atmospheric particles, aiding the identification of source regions.

Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경)

  • Jeung Jae Yeal;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

Prestenotic Bronchial Radioaerosol Deposition: A New Lung Scan Sign of Bronchial Obstruction (기관지 협착 근위부의 연무 침착: 폐스캔에서 기관지 폐색의 특이한 지표)

  • Chung, Soo-Kyo;Kim, Hak-Hee;Choi, Byung-Gil;Lee, Sang-Hoon;Kang, Si-Won;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.3
    • /
    • pp.307-312
    • /
    • 1995
  • The present study has been carried out to assess the diagnostic usefulness of radioaerosol lung scan in complete bronchial obstruction (n=7) and bronchial narrowing (n=1) of varying causes. $^{99m}Tc$-phytate lung scan was performed using the aerosol generated by a BARC nebulizer. Scan alterations were correlated with those of chest radiography, bronchography, lung CT and/or brochoscopy. In every case scan showed characteristic intense deposition of radioaerosol in a short slightly dilated, bronchial segment immediately proximal to obstruction or stenosis. Characteristically it was accompanied by an airspace aerosol deposition defect distally. The finding of a short, clubbed, bronchial radioaerosol deposition with distal airspace defect is a sensitive, specific indicator of bronchial obstruction or stenosis. It was especially useful in the detection of the obstruction of a small bronchus at the lobar and sublobar levels. We propose to name it the prestenotic aerosol deposition sign.

  • PDF