• Title/Summary/Keyword: Near-field Measurement

Search Result 350, Processing Time 0.039 seconds

A Study on the Improvement of Temporary Ventilation of long tunnel Using the Field Measurement data (현장 실측을 통한 장대터널 공사중 환기 문제점 연구)

  • Hong, Chang-Soo;Hwang, Dae-Jin;Kang, Hyun-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1350-1357
    • /
    • 2010
  • In tunnelling, temporary ventilation is very important factor in the safety of worker and the work efficiency which is affected by visibility. There are a lot of problems in the recent tunnel construction, because the longer the tunnel, the more the present design doesn't satisfy the allowable standard about dust and air pollution. Especially, In case the length of tunnel is more than 1,000m, the ventilation efficiency tends to decrease. In this study, the field measurement of the degree of contamination was performed near the face of tunnel. Based on the results obtained, the main factors of problem in temporary ventilation are the difference of temperature between outside and inside, the rate of leakage of ventilation duct and the dust and so on. It maybe helpful to the solution of problems, and also the accurate ventilation estimate.

  • PDF

Vortex dynamics in YBa$_2Cu_3O_7$ single crystals measured by micro Hall-probe array (Micro Hall probe array를 이용한 YBa$_2Cu_3O_7$ 단결정 내부의 자속 운동 측정)

  • Shim, Seong-Yeop;Hwang, Hyeon-Guk;Lee, Chang-Woo;Lee, Tae-Won;Kim, Dong-Ho
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.189-195
    • /
    • 1999
  • We have studied the vortex dynamics in YBa$_2Cu_3O_7$ single crystals with columnar defects using micro Hall-probe array. The Hall-probe array technique allowed a simultaneous measurement of the time and spatial dependence of the vortex density so that more detailed information on flux dynamics could be obtained. We found that field profiles inside sample were similar to the Bean's critical state model from the magnetic hysteresis measurement. Normalized relaxation rates were maximum near the center and decreased toward the edge if applied field H$_{app}$ is greater than the penetration field H. But applied magnetic field H$_{app}$ is less than H, relaxation rates were minimum near the center and increased toward edge. We found that glassy exponent ${\mu}$ has the value of ${\sim}$ 1 whose corresponding vortex motion is half-loop excitation. However, single vortex creep, ${\mu}$ ${\sim}$ 1/7, was also found at 30 K and H$_{app}$ ${\cong}$ H'. Calculation of activation energy, U, was possible from direct analysis of the local relaxation data using the basic diffusion equation. From these results, we found that U increases logarithmically with time and U around center was lower than that at the edge.

  • PDF

Semi-rigid Coaxial Cable Antenna for RTA (RTA용 반강체 동축케이블 안테나)

  • 강철준;박성교;문장원;박종백
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.262-265
    • /
    • 2003
  • Radiofrequency thermal ablation (RTA) as one of the microwave hyperthermia is becoming the treatment of choice for small but inoperable tumors of the liver. In this paper, we designed the applicator composed of semi-rigid coaxial cable antenna with a ring slot for RTA. To optimize the maximum output of radiation at 2450 MHz, we simulated the antenna using Electromagnetic simulation tools Maxwell program and analyzed the return loss and the electric field $E_{tot}$ at the near-field region between the simulation results and measurement results. As a result, we obtained the return loss of -29.786 dB at 2450 MHz when the antenna was placed between two blocks of a pig's liver, and the measurement results agreed with the simulation results well. Therefore, this semi-rigid coaxial cable antenna with a ring slot can be used very usefully as the applicator for RTA.r RTA.A.

  • PDF

The Improvement of Characteristics of The Applicator Using Semi-rigid Coaxial Cable Antenna for RFA (반강체 동축케이블 안테나를 이용한 RFA용 어플리케이터의 특성 개선)

  • 강철준;박성교;김선호;박종백
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.24-27
    • /
    • 2003
  • Radiofrequency ablation (RFA) as one of the microwave hyperthermia is becoming the treatment of choice for small but inoperable tumors of the liver. In this paper, we designed the applicator composed of semi-rigid coaxial cable antenna with a ring slot for RFA. To optimize the maximum output of radiation with omni direction at 2450 ㎒, we simulated the applicator using Electromagnetic simulation program and analyzed the return loss and the electric field E$\_$tot/ at the near-field region between the simulation results and measurement results. As a result, we obtained the return loss of -29.786 dB at 2450 ㎒ when the applicator was placed between two blocks of a pig's liver, and the measurement results agreed with the simulation results well. Therefore, this applicator using semi-rigid coaxial cable antenna with a ring slot can be used very usefully as the applicator for RFA.

  • PDF

A Hybrid Reader Antenna for Near- and Far-Field RFID in UHF Band (근거리장 및 원거리장용 하이브리드 RFID 리더 안테나)

  • Lee, Chu-Yong;Han, Wone-Keun;Park, Ik-Mo;Choo, Ho-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.2
    • /
    • pp.174-182
    • /
    • 2009
  • In this paper, we propose a novel hybrid reader antenna using a triangular and rectangular sub-patch for near- and far-field RFID reader in UHF band. The antenna operates at 912 MHz, and the low-cost mass-production is available, since the antenna can be built by printing on a FR-4 substrate. The triangular patch is designed to produce a circularly polarized radiation along the bore-sight direction and the rectangular sub-patch is designed to generate a strong magnetic field over the antenna aperture. The measurement shows Hz field greater than -25 dBA/m(3 cm above the antenna aperture), and exhibits circularly polarized radiation(AR<3 dB) with a radiation gain of 6 dBi.

Error Investigation in use of Near-field Acoustic Holography in the Underwater Environment of Reflected Wave (수중반사파 환경에서의 근접음장 홀로그래피 적용에 대한 오차 고찰)

  • Yi, Jongju;Kang, Myunghwan;Han, Seungjin;Jeong, Hyunjoo;Bae, Sooryong;Jung, Woojin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.12
    • /
    • pp.969-976
    • /
    • 2014
  • Nowadays, it is required for naval ships to estimate 3D underwater radiated noise pattern in all direction at peak frequencies of hull vibration for the reduction of being detected and doing the effective operation. For this purpose, the numerical method has to be developed to calculate 3D underwater radiated noise pattern with experimental data. It is very difficult to obtain the experimental data for the real ship. Alternative to get the experimental results is to use NAH(near-field acoustic holography) in acoustic tank with experimental model. Application of NAH in acoustic tank for the experimental model needs some investigation of reflection wave from the wall of the acoustic tank and unmeasured zone of the experimental model due to the supporting structure for it. In this study, the effect of reflection wave in the acoustic tank and unmeasured area of the experimental model when using the NAH was investigated with experiment and numerical model. From these, it is known for the error due to reflection wave can be reduced when the distance between the measurement plane and source is being shorten. Also, unmeasured area of the experimental model gives rise to some error in the estimation of the far-field acoustic pressure.

통신방송위성 안테나 얼라인먼트 측정

  • Yoon, Yong-Sik;Park, Hong-Chul;Son, Young-Seon;Lee, Byoung-Gi
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.117-125
    • /
    • 2004
  • The three-dimensional precision measurement technology for industrial product of middle and/or large scale has been developed. Theodolite measurement system which is one of the technology is widely used in aerospace industry. This paper describes a range alignment method of parabolic antenna to RF probe in the near field range by using the theodolite system. The range alignment of the Ku-band and Ka-band antennas has been accomplished within the requirements, ±1 mm and ±$0.05^{circ}$.

  • PDF

Near-Field Analysis of Vehicle LF Antennas for Estimating the Reading Range of a Smart Key (스마트 키 인식 거리 예측을 위한 차량 LF 안테나의 Near-Field 분석)

  • Kim, Heeyoung;Byun, Gangil;Seong, Jaeyong;Jung, Hankil;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.7
    • /
    • pp.671-677
    • /
    • 2013
  • In this paper, we propose a method of near-field analysis for vehicle LF antennas in order to estimate the accurate reading range of a smart key. The LF antenna consists of a ferrite core and a conducting wire which is coated with polyethylene for insulation, and it is mounted at the rear bumper frame of a commercial vehicle. The reading range of a smart key is measured at nine azimuthal directions distributed around the rear bumper, and then, the received power at each maximum reading range is measured by using a spectrum analyzer. The measurement shows that the maximum reading range exists between 1.38 m and 1.53 m, and the radiated power is between -83.6 dBmW and -75.0 dBmW. We further conducted EM simulation to estimate the reading range and the received power under the same condition that we applied for the measurement. The results demonstrate that an accurate reading range and received power can be achieved by simulation.

Development of Planar Active Phased Array Antenna for Detecting and Tracking Radar (화포탐지 레이다용 C-대역 평면형 능동위상배열 안테나 개발)

  • Kim, Ki-Ho;Kim, Hyun;Kim, Dong-Yoon;Jin, Hyung-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.924-934
    • /
    • 2018
  • This paper describes the development and measurement results of C-band planar active phase array antenna for detecting and tracking radar(weapon-locating radar). The antenna is designed with 14 sub-arrays(12 main channels and 2 sidelobe blanking channels and approximately 3,000 elements of transmit-receive channel) to generate transmit and digital receive patterns. Using a near-field measurements facility, G/N, transmit patterns, and received patterns are measured. Receive patterns are implemented with digital beamforming by signal processing. The measurement results demonstrate that antenna design specifications were fulfilled.

A Study on the Airflow near the Cold Heat Source Using CFD in Merchandising Store (CFD를 이용한 대형매장 냉열원 주변의 공기유동에 관한 연구)

  • Cho Sung Woo;Park Min Young;Im Young Bin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.7
    • /
    • pp.629-634
    • /
    • 2005
  • This paper performed to predict vertical temperature distribution and air flow near cold heat source in the mass merchandising store. At the height of 150 cm, the vertical air temperature difference between the results of CFD and of measurement field showed $10\%$ near the refrigeration zone and $8.8\%$ near the freezing zone. Therefore, it regarded as appropriate for the using CFD to investigate airflow near the heat sources. The 3 kinds of CFD model were divided by the disposition of diffuser/exhaust and diffuser air temperature. At the refrigeration and freezing zone in the Model 2 and 3, the temperature difference between the front and the back of human model were showed $6.8^{\circ}C\;and\;3.9^{\circ}C$ with diffuser air temperature $17^{\circ}C$ and were showed $6.8^{\circ}C$ and $4^{\circ}C$ with diffuser air temperature $19^{\circ}C$.