• Title/Summary/Keyword: Near infrared radiation sensor

Search Result 7, Processing Time 0.021 seconds

Development of Near Infrared Radiation Image Board for Performace Improvement of Grain Sorter (곡물선별기의 선별력 향상을 위한 근거리적외선 영상보드 개발)

  • Lee, Chae-Wook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.18 no.1
    • /
    • pp.25-30
    • /
    • 2017
  • Currently, most of the grain sorter uses CCD optic camera to find defective products. The aim of this paper is to use the CCD camera, and aim for improving the sorting power of the grain separator by using NIR(Near Infrared Radiation) sensor based on moisture content measurement algorithm. We intend to develop a system to develop an NFC imaging system in real time by developing an NIR imaging system and developing the grain sorter system that is considered to be defective in real time by checking the internal moisture content of the raw material in the real time.

  • PDF

Possibility and Accuracy of Extracting Room Temperature Information from Mid-Infrared Sensor Satellite Images (중적외선 센서 위성 영상의 상온 온도 정보 추출 가능성 및 정확도)

  • Choi, SeokWeon;Seo, DooChun;Lee, DongHan
    • Journal of Space Technology and Applications
    • /
    • v.1 no.3
    • /
    • pp.356-363
    • /
    • 2021
  • It was common knowledge in textbooks that images acquired using mid-infrared ray were not suitable for measuring temperature near room temperature. But a recent satellite image using a mid-infrared sensor show the possibility that the result measured using the mid-infrared sensor can also measure the temperature near room temperature. In this paper, the possibility and accuracy of extraction room temperature information from satellite images with mid-infrared sensors are reviewed. The mid-infrared satellite image reviewed in this paper showed the temperature of room temperature well, and regarding the reliability as an absolute value of the measured temperature, the effect of the heat transfer amount due to the direct reflection of sunlight on the surface and the effect of the infrared absorption amount absorbed in the atmosphere can be seen as a relatively small or constant value. However, the problem of uncertainty in the radiation coefficient due to physical properties, which is the limit of the non-contact thermometer, remained a problem to be solved.

Implemented of non-destructive intelligent fruit Brix(sugar content) automatic measurement system (비파괴 지능형 과일 당도 자동 측정 시스템 구현)

  • Lee, Duk-Kyu;Eom, Jinseob
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.433-439
    • /
    • 2020
  • Recently, the need for IoT-based intelligent systems is increasing in various fields. In this study, we implemented the system that automatically measures the sugar content of fruits without damage to fruit's marketability using near-infrared radiation and machine learning. The spectrums were measured several times by passing a broadband near-infrared light through a fruit, and the average value for them was used as the input raw data of the machine-learned DNN(Deep Neural Network). Using this system, he sugar content value of fruits could be predicted within 5 s, and the prediction accuracy was about 93.86%. The proposed non-destructive sugar content measurement system can predict a relatively accurate sugar content value within a short period of time, so it is considered to have sufficient potential for practical use.

COASTAL ENVIRONMENT MONITORING USING ADJACENT EFFECT OF RADIATION

  • Takashima, Tsutomu;Jung, Sung-Chul;Yi, San-Oh;Kim, Tu-Hwan
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.430-431
    • /
    • 2006
  • KOMPSAT-2 was successively launched on July 28,06. She carries Fine Spatial Resolution Sensor with three channels. It is 4m monochromatic and 1m panchromatic. The main purposes would derive fine urban map and digital elevation model(DEM).Therefore we extend to coastal environment monitoring using the adjacent effect of radiation due to an interaction of radiation between heterogeneous surface and atmosphere. With data analysis of ASTER on TERA, which is 15m resolution in visible and near infrared wavelengths, we found atmospheric aerosols were always large. Note that data analysis was limited in Nagoya bay, Lake Tahoe, California & La Pozuelos, La Picasa, Argentina. Thus this time we expect data analyses around isolated island and peninsula in west and south coast of Korea.

  • PDF

Non-Invasive HbA1c Measurement Using Two-Wavelength Raman Scattering (2 파장 라만 산란을 이용한 비침습적 HbA1c 측정)

  • Yang, Jooran;Kim, Hyungpyo
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.305-310
    • /
    • 2019
  • The purpose of this study is to classify the concentration of HbA1c (glycosylated hemoglobin), which is an indicator in the management of accurate blood glucose level in diabetic patients, using a non-invasive optical property measurement method. To measure the optical properties of HbA1c, the optical source uses LEDs and laser diodes of 400 nm in the visible region and 1450 nm in the nearinfrared region using thermopile to detect the Raman scattering intensity. An HbA1c control solution was used. As a result, the optical properties of 5% (normal) and 9% (abnormal) HbA1c control solutions showed specificity in which the output values were reversed at 850 nm and 950 nm, respectively. This property was applied to distinguish between normal and abnormal values in diabetes. In addition, considering tissue penetration depths for non-invasive measurements, two wavelengths were determined to be effective in distinguishing the concentrations of HbA1c control solutions at 5%, 7%, and 9%.

Analysis of Spatial Correlation between Surface Temperature and Absorbed Solar Radiation Using Drone - Focusing on Cool Roof Performance - (드론을 활용한 지표온도와 흡수일사 간 공간적 상관관계 분석 - 쿨루프 효과 분석을 중심으로 -)

  • Cho, Young-Il;Yoon, Donghyeon;Lee, Moung-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_2
    • /
    • pp.1607-1622
    • /
    • 2022
  • The purpose of this study is to determine the actual performance of cool roof in preventing absorbed solar radiation. The spatial correlation between surface temperature and absorbed solar radiation is the method by which the performance of a cool roof can be understood and evaluated. The research area of this study is the vicinity of Jangyu Mugye-dong, Gimhae-si, Gyeongsangnam-do, where an actual cool roof is applied. FLIR Vue Pro R thermal infrared sensor, Micasense Red-Edge multi-spectral sensor and DJI H20T visible spectral sensor was used for aerial photography, with attached to the drone DJI Matrice 300 RTK. To perform the spatial correlation analysis, thermal infrared orthomosaics, absorbed solar radiation distribution maps were constructed, and land cover features of roof were extracted based on the drone aerial photographs. The temporal scope of this research ranged over 9 points of time at intervals of about 1 hour and 30 minutes from 7:15 to 19:15 on July 27, 2021. The correlation coefficient values of 0.550 for the normal roof and 0.387 for the cool roof were obtained on a daily average basis. However, at 11:30 and 13:00, when the Solar altitude was high on the date of analysis, the difference in correlation coefficient values between the normal roof and the cool roof was 0.022, 0.024, showing similar correlations. In other time series, the values of the correlation coefficient of the normal roof are about 0.1 higher than that of the cool roof. This study assessed and evaluated the potential of an actual cool roof to prevent solar radiation heating a rooftop through correlation comparison with a normal roof, which serves as a control group, by using high-resolution drone images. The results of this research can be used as reference data when local governments or communities seek to adopt strategies to eliminate the phenomenon of urban heat islands.

THE NONDESTRUCTIVE MEASUREMENT OF THE SOLUBLE SOLID AND ACID CONTENTS OF INTACT PEACH USING VIS/NIR TRANSMITTANCE SPECTRA

  • Hwang, I.G.;Noh, S.H.;Lee, H.Y.;Yang, S.B.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.210-218
    • /
    • 2000
  • Since the SSC(soluble solid contents) and titratable acidity of fruit are highly concerned to the taste, the need for measuring them by non-destructive technology such as NIR(Visual and Near-infrared) spectroscopy is increasing. Specially, in order to grade the quality of each fruit with a sorter at sorting and packing facilities, technologies for online measurement satisfying the tolerance in terms of accuracy and speed should be developed. Many researches have been done to develop devices to measure the internal qualities of fruit such as SSC, titratable acidity, firmness, etc. with the VIS(Visual)/NIR(Near Infrared) reflectance spectra. The distributions of the SSC, titratable acidity, firmness, etc. are different with respect to the position and depth of fruit, and generally the VIS/NIR light can interact with fruit in a few millimeters of pathlength, and it is very difficult to measure the qualities of inner flesh of fruit. Therefore, to measure the average concentrations of each quality factor such as SSC and titratable acidity with the reflectance-type NIR devices, the spectra of fruit at several positions should be measured. Recently, the interest about the transmittance-type VIS/NIR devices is increasing. NIR light can penetrate through the fruit about 1/10-1/1,000,000 %. Therefore, very intensive light source and very sensitive sensor should be adopted to measure the transmitted light spectra of intact fruit. The ultimate purpose of this study was to develop a device to measure the transmitted light spectra of intact fruit such as apple, pear, peach, etc. With the transmittance-type VIS/NIR device, the feasibility of measurement of the SSC and titratable acidity in intact fruit cultivated in Korea was tested. The results are summarized as follows; A simple measurement device which can measure the transmitted light spectra of intact fruit was constructed with sample holder, two 500W-tungsten halogen lamps, a real-time spectrometer having a very sensitive CCD array sensor and optical fiber probe. With the device, it was possible to measure the transmitted light spectra of intact fruit such as apple, pear and peach. Main factors affecting the intensity of transmitted light spectra were the size of sample, the radiation intensity of light source and the integration time of the detector. Sample holder should be designed so that direct light leakage to the probe could be protected. Preprocessing method to the raw spectrum data significantly influenced the performance of the nondestructive measurement of SSC and titratable acidity of intact fruit. Representative results of PLS models in predicting the SSC of peach were SEP of 0.558 Brix% and R2 of 0.819, and those in predicting titratable acidity were SEP of 0.056% and R2 of 0.655.

  • PDF