• Title/Summary/Keyword: Near Infrared ray

Search Result 114, Processing Time 0.027 seconds

Non-destructive evaluation technology using infrared thermography and near infrared heating for detecting inside-defects of concrete structures (근적외선과 열화상 기법을 이용한 콘크리트 내부 공극 검출)

  • Sim, Jun-Gi;Zi, Goang-Seup;Lee, Jong-Seh
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1021-1024
    • /
    • 2008
  • Near infrared heating as an alternative to the conventional heating techniques for thermography -NDT is tried in this paper. A concrete specimen containing a defect was heated by the near infrared ray and the thermography-NDT technique was applied. Using a dimensinless temperature, the defects were detected. It was found that the near infrared ray could efficiently heat up the concrete specimen compared to others conventional methods like lamps, heat flow, etc.

  • PDF

Materials Characterization Using A Novel Simultaneous Near-Infrared/X-ray Diffraction Instrument

  • Yeboah, S.Agyare;Blanton, Thomas;Switalski, Steve;Schuler, Julie;Analytical, Craig Barnes
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1288-1288
    • /
    • 2001
  • X-ray powder diffraction (XRD) is utilized for determination of polymorphism in crystalline organic materials. Though convenient to use in a laboratory setting, XRD is not easily adapted to in situ monitoring of synthetic chemical production applications. Near-Infrared spectroscopy (NIR) can be adapted to in situ manufacturing schemes by use of a source/detector probe. Conversely, NIR is unable to conclusively define the existence of polymorphism in crystalline materials. By combining the two techniques, a novel simultaneous NIR/XRD instrument has been developed. During material's analysis, results from XRD allow for defining the polymorphic phase present, and NIR data are collected as a fingerprint for each of the observed polymorphs. These NIR fingerprints will allow for the development of a library, which can be referenced during the use of a NIR probe in manufacturing settings.

  • PDF

Application Study of Chemoinfometrical Near-Infrared Spectroscopic Method to Evaluate for Polymorphic Content of Pharmaceutical Powders (일본의 근적외선분광법에 대한 제약회사 응용 및 현황)

  • Otsuka, Makoto
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2002.11a
    • /
    • pp.97-117
    • /
    • 2002
  • A chemoinfometrical method for quantitative determination of crystal content of indomethacin (IMC) polymorphs based on fourie-transformed near-infrared (FT-NIR) spectroscopy was established. A direct comparison of the data with the ones collected from using the conventional powder X-ray diffraction method was performed. Pure $\alpha$ and ${\gamma}$ forms of IMC were prepared using published methods. Powder X-ray diffraction profiles and NIR spectra were recorded for six kinds of standard materials with various content of ${\gamma}$ form IMC. The principal component regression (PCR) analyses were performed based on normalized NIR spectra sets of standard samples of known content of IMC ${\gamma}$ form. A calibration equation was determined to minimize the root mean square error of the prediction. The predicted ${\gamma}$ form content values were reproducible and had a relatively small standard deviation. The values of ${\gamma}$ form content predicted by two methods were in close agreement. The results were indicated that NIR spectroscopy provides for an accurate quantitative analysis of crystallinity in polymorphs compared with the results obtained by conventional powder X-ray diffractometry.

  • PDF

Effect of Flocculant Injection Ratio in NIR (Near-Infrared Ray) Drying for BIO-SRF (Solid Recovered Fuel) of Swage Sludge (하수슬러지 BIO-SRF (Solid Recovered Fuel) 생산을 위한 NIR (Near Infrared Ray) 건조시 응집제 주입비율이 미치는 영향)

  • Lee, Kang-min;Lee, Seung-Won
    • Journal of Environmental Science International
    • /
    • v.30 no.2
    • /
    • pp.135-143
    • /
    • 2021
  • This study executed evaluation of drying characteristics based on the polymer injection rate (8%, 10% and 12%) and the drying method[NIF(near-infrared ray). According to this study analyzed VS, VS/TS, and calorific value compared with 'the auxiliary fuel standard of the thermoelectric power plant and the combined heat & power plant'. The results are as follows. In the case of NIR, the VS was slightly changed at the early stage of the material preheating period and the constant drying rate period with low moisture evaporation. But VS reduction was shown higher as moisture was dried. In the case of non-digested sludge with high VS content, the VS reduction rate by drying was shown lower than that of digested sludge. As the flocculant injection rate increased, the VS loss due th drying was found to be small. Also, the higher the flocculant injection rate was the longer the drying time. Especially, in the case of the NIR drying equipment, as the moisture content of sewage sludge decreased(moisture content 20~40%), the loss of net VS also showed a tendency to increase sharply. It is shown that the high calorific value according to the drying time of the non-digested sludge was changed from 590 kcaℓ/kg to 3,005 kcaℓ/kg and from 539 kcaℓ/kg to 2,796 kcaℓ/kg.

Effects of Wearable Near-Infrared Rays on Knee Pain in Korean Elderly Adults

  • Lee, Jin-Min;Kim, Kye-Ha
    • Journal of Integrative Natural Science
    • /
    • v.13 no.4
    • /
    • pp.121-127
    • /
    • 2020
  • To investigate the effects of wearable near-infrared ray-emitting knee pads on knee pain among elderly adults in Korea. Randomized controlled trial evaluating the effects of near-infrared rays (NIR) on knee pain in Korean elderly adults. Five community-based research facilities (two welfare centers, a senior citizen center, and two churches). Forty-seven participants aged 65 years and older who had experienced knee pain. The experimental group (n = 25) wore NIR-emitting knee pads for one month at nighttime while sleeping. The control group (n = 22) wore knee pads without NIR. Demographic characteristics, intensity and duration of knee pain, amount of analgesic medication used, range of motion, gait speed, and health-related quality of life were collected using questionnaires. The experimental group showed decreased intensity (t = -6.17, p < 0.001) and duration (t = -3.34, p = 0.002) of knee pain and reduced analgesic use (t = -2.30, p = 0.026) compared to the control group. NIR may be an effective non-pharmacological option for relieving knee pain in elderly adults.

Effect of Linear Polarized Near-Infrared Ray Radiation on the Experimental Pain Threshold in Healthy Subjects (직선 편광 근적외선 조사가 건강인의 실험적 통증역치에 미치는 영향)

  • Lee, Jae-Hyoung;Song, In-Young;Choi, Eun-Young
    • Journal of Korean Physical Therapy Science
    • /
    • v.2 no.4
    • /
    • pp.771-778
    • /
    • 1995
  • The purpose of this study was to determine the effects of linear polarized near-infrared ray radiation on experimental pain threshold in healthy adult subjects. Thirty healthy adult subjects were divided into 5 groups: 1) group 1, super lizer radiation at 0 % ; 2) group 2, super lizer radiation at 10 % ; 3) group 3, super lizer radiation at 20 % ; 4) group 4, super lizer radiation at 40 % ; 5) group 5, super lizer radiation at 80 %. The polarized near-infrared ray radiation was applied on LI 4 point of subject's right hand at a fixed time for 30 second. Experimental pain threshold were measured with electrical current on the right hand at 5 intervals for each radiation: 1) pretreat; 2) posttreat ; 3) posttreat of 1/2 hr ; 4) posttreat of 1 hr ; and 5) posttreat of 2 hrs. Data were analyzed using analyses of variance with repeated measures for pain threshold. No significant interaction between power output and time for pain threshold was found. Significant effects of power output and time for experimental pain threshold were found. Significant increase was noted in experimental pain threshold in group 4 and group 5 at posttreat, posttreat of 1/2, 1 hr and 2 hrs as a result of the applications of the polarized near-infrared ray radiation. This study indicate that polarized near-infrared ray radiation with above 40 % of power output increases pain threshold, thus possibly increasing options in choosing radiation output for treating pateint with pain. Further study is needed to compare the effects of these radiation in patients with clinical pain.

  • PDF

A study on the Drying Characteristics of NIR Dryer (근 적외선 건조기의 건조특성에 대한 연구)

  • Jang, Yeong-Suk
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • Near Infrared Ray (NIR) are primarily of interest to the high energy physicist. It is the intermediate portion of the spectrum, which extends from approximately 0.8 to 1.5 ${\mu}m$ and include a portion of the all of infrared, that is thermal radiation and is pertinent to heat transfer. It is important to study that temperature distribution of the drying materials by surface encompasses a range of NIR wave lengths. This study is to investigate the characteristics of NIR dryer by experimental results. it was made a comparison with various textiles, velocity ratio and distance of lamp and textiles. In case of spongy type textile the drying performance is the superior of all. The 0.15m distance drying effect of improvement 30% more than 0.26m distance between lamp and textiles. As the contained water increases, the drying speed for textile can be increased.