A Basical Study about Ventilation Performance of Natural Smoke Ventilators through Stack Effect in High-rise Building (고층건축물에서의 연돌효과에 따른 배연창의 배연성능에 관한 기초적 연구)

  • Kim, Hye-Won;Jin, Seung-Hyun;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.54-55
    • /
    • 2017
  • The High-rise building has a problem the ventilation performance of natural ventilator by stack effect that it occurs by pressure difference. For that reason the study about natural smoke ventilator of High-rise building consistently needs. Therefore on this study does analysis of difference with abroad through investigate of Natrual smoke ventilator's law, it conducts of natural smoke ventilator's research on the actual condition. As a result on this study, in the case of abroad that it states more specific standards than domestic. Also the result of a field study, it shows that the natural smoke ventilator is installed same size and the number regardless of building's pressure difference.

  • PDF

The Performance Evaluation of Natural Smoke Ventilators Due to Stack Effect and Wind Velocities in High-rise Buildings (고층건물에서 연돌효과 및 외기풍속에 따른 배연창의 배연성능 평가)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.82-90
    • /
    • 2009
  • Natural smoke ventilator is one of domestic prescriptive methods to be used to exhaust smoke in case of fire in a high-rise buildings. The goal of this study is to evaluate the stack effect and the smoke exhaust performance in high-rise buildings with the opening of natural smoke ventilators using computer modeling technology, thus to estimate its effectiveness as a tool of smoke exhaust. For this purpose, the pressure differential in a domestic high-rise building with natural smoke ventilators was experimentally measured to analyze the stack effect with the closure or the opening of natural smoke ventilators and to calculate compensated air leakage of the building. Computer modeling based on experimentally measured data was carried out to estimate effectiveness of natural smoke ventilators in high-rise buildings using CONTAMW network program.

Study of the Problems and Improvements of the Installation and Maintenance for Natural Smoke Ventilators in Buildings (국내 배연창 설치 및 유지관리의 문제점과 개선방안에 관한 연구)

  • Yun, Hi-Won;Choi, Seung-Hyuck;Ryu, Hyung-Kyou
    • Fire Science and Engineering
    • /
    • v.30 no.6
    • /
    • pp.118-123
    • /
    • 2016
  • In the event of a building fire, it is important to control the smoke generated to ensure the safe evacuation of occupants. A natural smoke ventilator should be installed to exhaust the fire smoke in accordance with the Korean building Act and Code. On the other hand, the present law does not specify the contents regarding natural smoke ventilators sufficiently. The problems that occur in various parts, such as the installation target, installation location, free area, and the control and maintenance of natural smoke ventilators need to be solved. In this study, the problem of the current system was examined through domestic and foreign standards, preliminary research, and field investigations. In addition, suggestions for improvement are provided.

Performance Evaluation of a Natural Smoke Ventilator in Jeju (배연창의 개방층 설정방식에 따른 배연성능 평가 연구(제주지역 중심으로))

  • Lim, Chae-Hyun
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • This study analyzed the performance of smoke exhaustion installed to secure the life safety from the smoke each opening modes, as performing the simulation on the Jeju regions generating to strong windy using CONTAM. We assessed the effectiveness of the system under conditions of high external winds as well as an ambient wind conditions. It also assessed the relative effectiveness of opening all vents versus opening only those vents which served rooms in which the fire was located. This study revealed external winds exerted a substantial impact on the performance of the smoke ventilation system. It was found that opening the ventilation system in the room containing the fire resulted in a greater performance than opening vents in both fire in all rooms. The reduced performance of the smoke ventilation system upon the opening of all vents is thought to be due to the intrusion of outside air, and the establishment of unfavorable air circulation, caused by the negative pressure generated in the building.

Experiments on the Influence of Opening of Natural Smoke Ventilators on the Stack Effect in High-rise Mixed-use Residential Buildings (초고층주상복합건물에서 배연창 개방이 연돌효과에 미치는 영향에 대한 실험적 연구)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.3
    • /
    • pp.89-94
    • /
    • 2009
  • The stack effect in high-rise buildings is expected more significant at nights in winter due to the large temperature difference between the inside and outside of the buildings. However, the existence of large openings such as natural ventilators on the floor may effect the position of neutral plane, smoke spread at fire and thus obstruct the door openings for rescue. In this paper, the vertical and horizontal pressure distribution with different openings of natural smoke ventilators was experimentally analyzed by investigating pressure differentials.

Mass Flow Rates and Performance of Natural Smoke Ventilators in High-rise Buildings (초고층건물에서 배연창의 풍량해석 및 배연성능)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.23 no.6
    • /
    • pp.91-97
    • /
    • 2009
  • The mass flow rates and performance of natural smoke ventilators in high-rise buildings with 40, 80, 120 stories were evaluated using CONTAMW tool. The results showed that only limited part of smoke ventilators can have positive exhaust flow in high-rise buildings due to stack effect and wind velocities. In the higher story buildings larger stack effect can overcome outside strong wind effect to give more ventilation performance. The air tightness of the building have strong effect on the exhaust performance of the ventilators to give lower performance with loose air tightness of the exterior walls.

The Influence of Natural Smoke Ventilators and Wind Velocities on the Stack effect in High-rise Buildings (배연창 및 외기풍속이 초고층 건축물의 연돌효과에 미치는 영향)

  • Lim, Chae-Hyun;Kim, Bum-Gyu;Yeo, Yong-Ju;Park, Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.20-26
    • /
    • 2008
  • The performance of natural smoke ventilators in High-rise buildings was analyzed by investigating the stack effect depending on the wind velocities using CONTAMW tool. The results showed that the opening of smoke ventilators can influence on the stack effect in the building thus moving the position of the neutral plane toward the opened smoke ventilators. The outside wind velocities can move up the neutral plane toward the top of the building thus increasing pressure differentials at the bottom of the building. The smoke ventilators can maintain its normal performance without outside wind, however, strong outside wind can prevent natural smoke exhaust due to the infiltration of outside air at the ventilators.

Performance requirement and Evaluation of Natural Smoke Exhaust Ventilator for High rise building (고층건물용 배연창의 성능기준 및 시험평가연구)

  • Kwark, Ji-Hyun;Choi, Jung-Min;An, Byung-Ho;Kim, Bum-Kyue;Park, Yong-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.129-138
    • /
    • 2009
  • 화재발생시 가장 주요한 사망원인인 유독가스의 제어와, 소방관의 소화활동을 돕기 위한 제연설비는 각 구성품이 유기적으로 동작하는 시스템을 이루기 때문에 전체의 조화도 중요하지만, 기본적으로 각 설비요소가 제 기능을 발휘할 때 전체 시스템의 제연성능을 확보할 수 있게 된다. 그러나 현재 법으로 규정된 국내기준은 주요 구성품별 성능을 제대로 평가할 수 있는 방법 및 기준이 없어 본 연구를 통하여 배연창의 성능평가기술을 개발하고 항목별 성능시험을 실시하여 평가방법의 적합성을 검토하고 국가표준을 만들기 위한 기초 자료로 제공하고자 한다.