• Title/Summary/Keyword: Natural Tooth

Search Result 298, Processing Time 0.028 seconds

The level of buccal gingival margin around single and two adjacent implant restorations: a preliminary result

  • Kim, Young-Bum;Shim, June-Sung;Han, Chong-Hyun;Kim, Sun-Jai
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.140-144
    • /
    • 2009
  • STATEMENT OF PROBLEM. Little information is available about the buccal gingival level of multiple implant restorations. PURPOSE. This study was aimed to evaluate the relationship between width and height of buccal soft tissue around single and 2 adjacent implant restorations. MATERIAL AND METHODS. Four implant restoration groups (first and second molars, single second molars, posterior single restorations between teeth, and anterior single restorations between teeth) were randomly chosen from one dental institute. Each group comprised of 6 patients. After 6 months of function, silicone impressions were taken and stone models were fabricated for each restoration group. The stone models were cut in bucco-lingual direction at the most apical point of buccal gingival margin. The height and width of buccal supra-implant soft tissue were measured. One way ANOVA and Tukey HSD post hoc tests were performed to analyze the data obtained (P < .05). RESULTS. The most unfavorable width-height ratio was noted for the group, which was comprised of the second molar in the multiple adjacent (first and second molar) implant-supported restorations. The group also resulted in the shorter height of buccal supra-implant mucosa rather than that of anterior single implant restorations between natural teeth. CONCLUSION. To achieve a favorable level of buccal gingival margin, greater thickness of buccal supra-implant mucosa is required for the implant restorations without a neighboring natural tooth compared to the implant restorations next to a natural tooth.

A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelain

  • Jung, Yu-Seok;Lee, Jae-Whang;Choi, Yeon-Jo;Ahn, Jin-Soo;Shin, Sang-Wan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.3
    • /
    • pp.111-115
    • /
    • 2010
  • PURPOSE. This study was conducted to evaluate clinical validity of a zirconia full-coverage crown by comparing zirconia's wear capacity over antagonistic teeth with that of feldspathic dental porcelain. MATERIALS AND METHODS. The subject groups were divided into three groups: the polished feldspathic dental porcelain group (Group 1), the polished zirconia group (Group 2), and the polished zirconia with glazing group (Group 3). Twenty specimens were prepared from each group. Each procedure such as plasticity, condensation, and glazing was conducted according to the manufacturer's manual. A wear test was conducted with 240,000 chewing cycles using a dual-axis chewing simulator. The degree of wear of the antagonistic teeth was calculated by measuring the volume loss using a three-dimensional profiling system and ANSUR 3D software. The statistical significance of the measured degree of wear was tested with a significant level of 5% using one-way ANOVA and the Tukey test. RESULTS. The degrees of wear of the antagonistic teeth were $0.119{\pm}0.059\;mm^3$ in Group 1, $0.078{\pm}0.063\;mm^3$ in Group 3, and $0.031{\pm}0.033\;mm^3$ in Group 2. Statistical significance was found between Group 1 and Groups 2 and between Group 2 and 3, whereas no statistical significance was found between Group 1 and Group 3. CONCLUSION. Despite the limitations of this study on the evaluation of antagonistic teeth wear, the degree of antagonistic tooth wear was less in zirconia than feldspathic dental porcelain, representing that the zirconia may be more beneficial in terms of antagonistic tooth wear.

FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION ACCORDING TO THE METHOD OF RESTORATION AFTER ROOT CANAL THERAPY (상악 소구치 근관치료후 수복방법에 따른 응력 분포의 유한 요소 분석)

  • Lee, Chung-Sik;Lee, Jae-Young;Cho, Hyo-Sun
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.339-352
    • /
    • 1996
  • Many dentists have been taken an interest in restoration of severly damaged teeth after endodontic treatment and it is a true that there are lots of studies about it. In these days, although we have used Para-Post, pins, threaded steel post, cast gold post and core, and so on, as a method of restoration frequently, it has been in controversy with the effects of them on the teeth and surrounding periodontal tissue. In this study, we assume that the crown of the upper 1st premolar was severly damaged, and after the root canal therapy, two most common types of restoration were carried out ; 1) coronal-radicular amalgam restoration, 2) after setting up the Para-Post, restore with amalgam core and gold crown. After restoration, in order to present the concentration of stress at internal portion of the tooth and the surrounding periodontal tissue, we doveloped a 2-dimensional finite element model of labiopalatal section, then loaded forces from 2 long perpendicular to the lingual incline of buccal ridge an the middle point, parallel to the long direction axis of tooth at the fossa-were applied. The analyzed results were as follows : 1. Stress of the normal first premolar was concentrated on the most weakest anatomical structure, that is, cervical area, and no stress on the bifurcated area of the canal. 2. Crown restoration after root canal therapy causes large stress concentration on the bifurcated area of the canal. This stress concentration has larger value in case of lateral movement of mandible, and there are decrease in the stress concentration compared with natural tooth. 3. Coronal-radicular amalgam restoration method transports more stress to the tooth structure than restoration using Para-Post. 4. There are more stress concentration around Para-Post in the case of lateral movement, and we have more favo rable result when restored with Para-Post. 5. Generally, stress in the lateral movement is larger than stress in the perpendicular load.

  • PDF

Esthetic restoration of subgingival crown-root fractured maxillary anterior tooth using surgical extrusion (외과적 정출술을 통한 치은 하방 치경부 파절선이 있는 상악 전치부의 심미 보철 치료)

  • Lee, So-Jin;Kim, Yu-Jin;Park, Young-Bum;Cho, Kyoo-Sung;Chung, Moon-Kyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.204-209
    • /
    • 2012
  • Surgical extrusion, immediate extrusion following tooth luxation, is a method to preserve one's natural tooth and achieve esthetic restoration without additional periodontal surgery when subgingival dental caries or crown fracture occurs. A 16-year-old male was referred to the clinic from the department of operative dentistry for the esthetic restoration of maxillary left lateral incisor. Due to the crown to root fracture, the tooth was endodontically treated with a buccal crown length of 4 mm. When the palatal flap was elevated, the mesiopalatal cervical fracture area was situated 3-4 mm subgingivally. Crown lengthening was achieved through surgical extrusion. After 3 months of clinical observation and provisional restoration, the maxillary left central incisor was restored with all ceramic crown and obtained a satisfactory clinical result.

A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS ON STRESS AND DISPLACEMENT RELATED TO ISTHMUS WIDTH OF GOLD INLAY CAVITY (금인레이 와동의 폭경이 응력분포와 변위에 미치는 영향에 관한 3차원 유한요소법적 연구)

  • Hwang, Ho-Keel;Im, Mi-Kyung
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.384-408
    • /
    • 1994
  • The purpose of this study was to evaluate the fracture resistance of tooth restored with gold inlay. A profound understanding of the isthmus width factor, which is one of the several parameters of cavity designs, would facilitate the appropriate cavity preparation in a specific clinical situation. In this study, the cavities for gold inlay were prepared in maxillary left first premolar. A three-dimensional model was designed using I-DEAS program. The model was composed of 2515- nodes and 2172 isoparametric brick elements. In the model isthmus width was varied into 1/4, 1/3 and 1/2 of intercuspal width respectively, and numeric values of the material properties of enamel, dentin and gold was set. Three types of load : concentrated load, divided load and distributed load was 500N. The empty cavities in the model were also examined using divided load and distributed load. The three - dimensional Finite Element Method was used to analysis the displacement and stress distribution. The results were as follows : 1. All of the experimental models which were filled with gold inlay revealed similar direction of displacement to that of the natural tooth model under the same load type. But in the models with empty cavities, as the isthmus width increased, the degree of displacement increased in the case of divided load type. 2. All experimental models which were filled with gold inlay showed stress concentration at load points, but in the models with empty cavities at divided load type, as isthmus width increased, stress was concentrated at the comer of the pulpal floor. 3. In the models with empty cavities at divided load type, tooth fracture was expected regardless of isthmus width, but all experimental models which were filled with gold inlay after cavity preparation were not susceptible to fracture. 4. In all experimental models which were filled with gold inlay after cavity preparation, displacement patterns were similar under both concentrated and divided load types. In the models with empty cavities, a divided load resulted in a bucco-lingual cuspal displacemenat in both sides, but a distributed load resulted in a lingual displacement of the tooth.

  • PDF

Dental trauma patients visiting the emergency room in H hospital (H 병원 치과응급실에 내원한 치아 외상 환자에 대한 임상적 고찰)

  • An, So-Youn;Kim, Ah-Hyeon;Shim, Youn-Soo
    • Journal of Korean society of Dental Hygiene
    • /
    • v.13 no.5
    • /
    • pp.819-826
    • /
    • 2013
  • Objectives : The purpose of this study was to analyze the types of dental emergencies. This study was carried out for dental trauma patients visiting the emergency room in H hospital from 2005 to 2006. Methods : Subjects were 252 patients. Demographic characteristics consisted of age, gender, dentition, and dental related injury. Results : Male patients had 1.65 times higher tooth injury than female. Teenagers had higher prevalence of tooth injury. Main cause of dental injury was falling down. Young children accounted for 41.7% of the injuries. Late evening was the highest outbreak time of injury. The most commonly affected teeth were central incisor and lateral incisor. The damage of oral soft tissue was more common than the that of alveolar bone. Main area of primary tooth loss was gingiva(10.7%), tongue or soft palate(7.5%), and frenulum(6.0%). Subluxation(28.6%) and luxation(28.6%) were main cause for the primary teeth. Tooth fracture(50.0%) were the most common injury. Conclusions : Thus, to understand the incidence, causes and patterns of dental trauma is to help preserving natural teeth. The results of this study could provide the clinical guidelines on the treatment of dental emergency patients.

Full mouth rehabilitation of a patient with severe tooth erosion with a digital crown lengthening guide (심한 부식 환자의 디지털 치관연장술 가이드를 이용한 전악 수복 증례)

  • Park, Yunjae;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.280-287
    • /
    • 2019
  • In the oral cavity, the teeth undergo wear and corrosion throughout their lives. Progressive and constant tooth wear is a natural phenomenon of aging, but wear and corrosion due to specific factors are pathological factors. It can cause pathological damage of the occlusal surface, aesthetic problems, dimensional loss and jaw joint disorders. This case is a 26-year-old female patient with general tooth abrasion and erosion on the entire dentition. Diagnostic wax-up was fabricated based on the information including digital facial analysis, physiological stabilization, and evaluation of anterior crown length. Through the digital analysis, the necessary guides for crown lengthening were prepared and the mastication function and esthetics were evaluated by using temporary crowns. Definitive prosthesis was fabricated with the zirconia restorations. The results were satisfactory when they were observed 3 months of follow-up.

Efficacy of live NNV immersion vaccination in three grouper species (Seven band grouper Hyporthodus septemfasciatus, Red spotted grouper Epinephelus akaara, Long tooth grouper Epinephelus bruneus) (바리과 어류 3종(능성어 Hyporthodus septemfasciatus, 붉바리 Epinephelus akaara, 자바리 Epinephelus bruneus)에 대한 신경괴사증바이러스(Nervous Necrosis Virus, NNV)의 생백신 처리 효과)

  • Kim, Si-Woo;Park, Jung-Jun;Hong, Chang-Gi;Oh, Myung-Joo
    • Journal of fish pathology
    • /
    • v.34 no.1
    • /
    • pp.99-104
    • /
    • 2021
  • In this study, we investigated safety and efficacy of a low temperature immunization protocol with NNV in red spotted grouper, Epinephelus akaara and long tooth grouper, Epinephelus bruneus and seven band grouper, Hyporthodus septemfasciatus. Further, growth rate between immunized and naïve fish was evaluated during the experiment to check side effect of immunization. Three grouper species were immunized by immersion method with live NNV at 105.0 TCID50/mL at 16.5℃ for 30 min and reared for 120 days at natural sea water temperature. To evaluate growth rate, total length and wet weight was measured 7 times after immunization. Immunized three grouper species were challenged by intramuscular inoculation with NNV at 104.2 TCID50/100 µL/fish. Immunization at low temperature with live NNV did not show any clinical symptoms of infection, mortality and inhibition of growth. After challenge, cumulative mortality of naïve seven band grouper, red spotted grouper, long tooth grouper were 45, 10, 20 %, respectively. However no mortality was observed at immunized groupers. Thus, it was demonstrated that immunization at low temperature with live NNV are able to protect three different species of groupers without inhibition of growth.

Full mouth rehabilitation on the patient with maxillary anterior diastema and posterior bite collapse with orthodontic treatment (상악 전치부 치간 이개와 구치부 교합지지 상실을 가진 환자에서 교정치료를 동반한 완전 구강회복 증례)

  • Lee, Seon-Ki
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.60-68
    • /
    • 2022
  • A patient with severe periodontitis has causative factors that cause pathological tooth movement, the occlusion is disintegrated, and the vicious cycle of worsening periodontitis is repeated. In particular, when pathological tooth movement occurs in the maxillary anterior region, the patient has an aesthetic sense of atrophy, and the quality of life was reduced. Therefore, when orthodontic treatment was added to patients with severe periodontitis, it promotes the formation of new bone, reduces periodontal cysts, and obtains clinical attachment, which leads to favorable results in prosthetic restoration, thereby enabling ideal occlusion, function and aesthetics. Periodontal treatment, orthodontic treatment, natural tooth restoration, and implant prosthesis were planned for patients with pathological tooth movement in the anterior region due to loss of occlusal support in the posterior region. As a result, an ideal restoration space was secured, a stable restoration of occlusal contact was formed, and the maxillary anterior teeth were aesthetically improved.

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY FIXED PROSTHESES WITH RIGID OF NONRIGID CONNECTION BETWEEN NATURAL TOOTH AND OSSEOINTEGRATED IMPLANT (골육착성 보철 치료시 임플랜트와 자연 지대치와의 연결 방법에 따른 관탄성 응력 분석)

  • Kim, Young-Il;Chung, Chae-Heon;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.271-300
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of connection modality between implant and tooth in the superstrcture. This investigation evaluated the stress patterns in a photoelastic model produced by three different types of dental implants such as Branemark, Steri-Oss, IMZ and resin tooth using the techniques of quasi three dimensional photoelasticity. The teeth-supported bridge had a first molar pontic supported by second premolar and second molar as a control group. The implant and toothsupported bridge had a first molar pontic supported by second premolar and implant posterior retainer as an experimental group. Prostheses were mechanically connected to an adjacent second premolar by the rigid of nonrigid connection, Nonrigid connection used an attachment placed between the tooth-supported and fixture-supported component. The female(keyway) of attachment was placed on the distal end of the retainer supported by the tooth ; the male(Key) of attachment connected to the osseointegrated bridge was engaged into the keyway. All prostheses were casted in the same nonprecious alloy and were cemented and screwed on their respective abutments and implants. 16㎏ of vertical loads on central fossae of second premolar, first molar pontic, implant of second molar were applied respectively and 6.5㎏ of inclined load on middle buccal surface of first molar pontic was applied. The results were as follows : 1. Under the vertical load on the central fossa of first mloar pontic, the stress developed at the apex of tooth of implat was more uniformly distributed in the case of nonrigid connection than in the case of rigid connection. 2. Under the vertical load on the central fossa of first molar pontic, the stress developed around the cervical area of tooth of implant was larger in the case of rigid connection than in the case of nonrigid connection because the bending moment was more occured in the case of rigid connection than in the case of nonrigid connection. 3. Stress was more restricted to the loaded side of nonrigid connection than to that of rigid connection 4. Under the inclined load. The set screw loosening of implant was more easily occured in the case of nonrigid connection than in the case of rigid connection due to torque moment. 5. In the case of Branemark implant, the stress concentration in second premolar was larger and the stress developed around the cervical area of implant was lower than any other cases under the vertical load, because Branemark implant with the flexible gold screw was showed in incline toward second premolar by a bending moment. 6. The stress developed around the apex of tooth or implant was more uniformly distributed in the case of Steri-Oss implant with stiff screw than in the case of Branemark implant under the vertical load. But, the stress developed around the cervical area of the Steri-Oss implant was larger than that of any other implants because bending moment was occured by vertical migration of second premolar. 7. The stress distribution in the case of IMZ implant was similar to the case of natural teeth under small vertical load. But, the residual stress around the implant was showed to occurdue to deformation of IMC and sinking of screw under larger vertical load.

  • PDF