AC Breakdown Voltage and Viscosity of Palm Fatty Acid Ester (PFAE) Oil-based Nanofluids

  • Mohamad, Mohd Safwan;Zainuddin, Hidayat;Ab Ghani, Sharin;Chairul, Imran Sutan
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2333-2341
    • /
    • 2017
  • Mineral oils are commonly used as transformer insulation oils but these oils are obtained from non-renewable and non-sustainable sources, which is highly undesirable. For this reason, natural ester oils are now being used in replacement of mineral oils because of their good biodegradability, high cooling stability, good oxidation stability and excellent insulation performance. Nanotechnology has gained prominence in both academic and industrial fields over the years and it has been shown in previous studies that nanoscale materials are useful for transformers due to their favourable dielectric properties. The objective of this study is to compare the AC breakdown voltage and viscosity of natural ester oil with three types of nanofluids. The natural ester oil-based nanofluids are prepared by mixing palm fatty acid ester (PFAE) oil with three types of nanoparticles at a concentration of 0.01 g/l: (1) $Fe_3O_4$ conductive nanoparticles, (2) $TiO_2$ semi-conductive nanoparticles and (3) $Al_2O_3$ insulating nanoparticles. The AC breakdown voltage of the oil samples is analysed using Weibull statistical analysis and the results reveal that the PFAE oil-based $Fe_3O_4$ nanofluid gives exceptional dielectric performance compared to other oil samples, whereby the AC breakdown voltage increases by 43%. It can be concluded that the PFAE oil-based $Fe_3O_4$ nanofluid is a promising dielectric liquid to substitute mineral oils.

Prediction of boil-off gas and boil-off rate in cargo tank of NGH carrier

  • Kang, Ho-Keunn;Kim, Dongeum;Kim, You-Taek;Park, Jung-Dae;Kang, Shin-Baek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.10
    • /
    • pp.1002-1010
    • /
    • 2015
  • Natural gas hydrates are newly emerging as an environment-friendly source of energy to substitute for fossil fuels in the 21stcentury.NGHs are reported to holds much amounts of natural gas (up to 182 standard volumes of gas per volume of hydrate); they are easy to store and safe to carry at about minus 20 degree Celsius under atmospheric pressure because of the self-preservation phenomenon of gas hydrates. The transporting method by gas-ice-hydrate ship carriers has been introduced and developed by a variety of industry and research institutions. Our team has been conducted to develop NGH total systems, including a breakthrough NGH carrier for sea transportation, since 2011. The NGH pellet carrier does not require a separate cooling system for cargo, and the initial temperature is maintained through insulation of the cargo tanks throughout the transport to the final destination. The heat conducted from the exterior and passing through the insulation material of the hull should be cut off as much as possible, but heat inflow inside the cargo tank from an external source is inevitable during transport. In this study, the heat transfer in a cargo tank of a 115K NGH carrier was analyzed through simulation with a commercial CFD code to estimate the boil-off gas/boil-off rate on the developed carrier and understand major hazards that could significantly impact the safety of the vessel.

Preliminary Experimental Study on the Two-phase Flow Characteristics in a Natural Circulation Loop (자연순환 루프에서 이상유동 특성에 관한 예비실험 연구)

  • Kim, Jae-Cheol;Ha, Kwang-Soon;Park, Rae-Joon;Hong, Seong-Wan;Kim, Sang-Baik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.308-311
    • /
    • 2008
  • As a severe accident mitigation strategy in a nuclear power plant, ERVC(External Reactor Vessel Cooling) has been proposed. Under ERVC conditions, where a molten corium is relocated in a reactor vessel lower head, a natural circulation two-phase flow is driven in the annular gap between the reactor vessel wall and its insulation. This flow should be sufficient to remove the decay heat of the molten corium and maintain the integrity of the reactor vessel. Preliminary experimental study was performed to estimate the natural circulation two-phase flow. The experimental facility which is one dimensional, the half height, and the 1/238 channel area of APR1400, was prepared and the experiments were carried out to estimate the natural circulation two-phase flow with varying the parameters of the coolant inlet area, the heat rate, and the coolant inlet subcooling. In results, the periodic circulation flow was observed and the characteristics were varied from the experimental parameters. The frequency of the natural circulation flow rate increased as the wall heat flux increased.

  • PDF

An Optimized Design and Simulation Analysis of Natural Ventilation Window System classified by Apartment type (주거용 건물 유형별 자연환기시스템의 최적 설계 및 해석)

  • Choi, Gyeong-Seok;Jeong, Young-Sun;Kang, Jae-Sik;Lee, Seung-Eon;Jeong, Yeong-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.685-688
    • /
    • 2009
  • On account of Indoor Air Quality(IAQ) deterioration by reason of high insulation and air tightness for energy saving, absence of energy efficiency ventilation system development that can be domestic existing window system, the cost increase and the energy addition loss by mechanical ventilation for IAQ improvement, the ventilation obligation making design standard was prepared by a social and technical background and the necessity. In this study, an optimized design and simulation Analysis of natural ventilation window system classified by Apartment type was evaluated by CFD Computational analysis.

  • PDF

On the Design of Cold Storage for Fruits and Vegetables (1) -Design of Natural Ventilating Type Store for Citrus Furits in Jejudo- (청과물 저온저장고의 설계에 관한 연구 (1) -자연환기를 이용한 제주산밀감저장고의 설계-)

  • Hur Jong-Wha;Kim Hyo-Kyung
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.5 no.4
    • /
    • pp.272-280
    • /
    • 1976
  • A natural ventilating type store was designed for the economic and effective storage of citrus fruits in Jejudo. The material used for the wall is scoria, widely distributed in Jejudo and known for high strength and insulation. Design condition was chosen for the period till March of a year and the dry bulb temperature was taken from TAC $5\%$ base. The temperature of the store can be maintained below the limiting temperature of $8^{\circ}C$ for the time length of $7\frac{1}{2}$ hours under the condition of the atmospheric temp, $15.3^{\circ}C$ and the solar insolation. The limiting temperature can he recovered to the initial temperature $(7^{\circ}C)$ by the natural ventilation for 8 hours in the night.

  • PDF

Vibration Analysis in Reinforced Concrete Slab Using Tables of Orthogonal Arrays (직교배열표을 활용한 슬래브 구조체의 진동 해석)

  • Seo, Sang-Ho;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.372-378
    • /
    • 2005
  • Finite element analysis of concrete slab system in apartment building was executed using the tables of orthogonal arrays, and optimal design process was proposed. At first, experimental results show that sound peak components to influence the overall level and the rating of floor impact sound insulation were coincident with natural frequencies of the reinforced concrete slab. Finite element model of concrete slab was compared with experimental results, and well corresponded with an error of less than 10%. The tables of orthogonal arrays were used for finite element analysis with 8 factors. 3 related to material properties and 5 related to slab shape parameters and its results were analyzed by statistical method, ANOVA. The most effective factor among them was slab thickness, and main effect factor from slab shape parameters was different from each natural frequency. The interaction was found in the higher mode over $3^{rd}$ natural frequency. From main effect plot and interaction plot, the optimal design factor to increase the natural frequency was determined.

  • PDF

A Study on the elementary school design based on ecological approach - Focused on the shared space of the elementary school of in Osaka Japan and Busan Korea - (Ecoloy개념을 적용한 초등학교 공간디자인에 관한 연구 - 일본 오사카시 초등학교와 부산시 초등학교 사례분석 -)

  • Yun, Ji-Young;Song, Ju-Eun
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2004.05a
    • /
    • pp.136-140
    • /
    • 2004
  • This study starts from the premise that future elementary school should be designed based on ecological approach. In order to restore the emotionality of children, school should provide and protect our natural environment by greening and energy saving. The research was conducted in Osaka and Busan to analyze the present condition of elementary schools in terms of ecology. The shared spaces such as halls, corridors, stairs and rest areas of fourteen schools were chosen and analyzed by the design analysis list. The list included the guidelines including greening, lighting, heating and cooling, ventilation and use of materials. The results showed that Korean schools require void space for more natural lighting, ventilation and insulation, while Japanese schools have problems in use of environmentally friendly materials, natural lighting and interior greening. This study reveals that ecological approach including greening and natural lighting should be considered in future elementary school design to make the school environment more agreeable and economical.

  • PDF

Compression Dynamic Performance of Glass Bubble/Epoxy Resin Adhesion (글라스버블/에폭시 수지 접착부의 극저온 압축 동적 성능)

  • Bae, Jin-Ho;Hwang, Byeong-Kwan;Lee, Jae-Myung
    • Composites Research
    • /
    • v.32 no.2
    • /
    • pp.90-95
    • /
    • 2019
  • Sloshing impact loads on liquefied natural gas (LNG) carr iers are the main issue of damage to the insulation system in LNG cargo containment system (LNG CCS). The damage to the insulation system would be fatal in maintaining a temperature-savings environment in LNG CCS. The typical method is to enhance the insulation materials that can maintain a constant cryogenic temperature. Insulation materials consist of polyurethane foam and plywood, an adhesive for bonding these two materials. This study intends to improve the absorption energy of the material when the impact load is applied by creating a glass bubble/epoxy composite resin as part of the insulation. The experimental scenarios consider the effect of temperature ($20^{\circ}C$, $-163^{\circ}C$), glass bubble weight fraction in epoxy resin through free fall experiments. Experiments have shown that if the glass bubble additive reaches 20 wt.%, the cryogenic absorption energy is a maximum performance and that 0 wt.% has a maximum ambient absorption energy. However, the agglomeration has been occurred due to deterioration of the stirring performance if weight fraction was 20 wt.% and the result of 0 wt.% have been revealed that ambient absorption energy is significantly lower.

A Study on the Envelop to Improve Interior Environment Performance of High-rise Residential Building (초고층 주상복합 건물의 실내 환경 성능 향상을 위한 외피부 개선방향에 관한 연구)

  • Park, Sang-Hoon;Cho, Ga-Young;Lee, Sun-Woo;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.306-309
    • /
    • 2006
  • The architectural difference between the existing residence and high-rise residential building causes changes on environmental conditions such as ventilation and insulation. The object of this study is to present the improvement on envelop of high-rise residential buildings to reduce heating and cooling load. To improve the environmental performance of envelop, it is necessary to modify envelop vent system and ensure intermediate space. In this study, the shape of vents in high-rise residential buildings has been inspected, and the survey about the interior environmental conditions related to the envelop of high-rise residential building has been conducted. Environmental measurement has been done to examine out door air quality for natural ventilation.

  • PDF

A Study on the Thermal and Electrical Characteristics with Manufacture of the Heating Element by Using Carbon with Bar Type (봉상 카본 발열체의 제조와 열 및 전기적 특성에 관한 연구)

  • 배강열;이광성;정한식;정희택;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.430-437
    • /
    • 2004
  • This paper is intended as an investigation of study on the thermal and electrical characteristics of the carbon heating element. In this experimentation, the electric material used is the crystalline graphite a kind of natural graphite. The bentonite is used to solidify the heating element and the vacuum furnace is used for sintering it. It is noted that the natural drying time should be at least 58 hours. The plating of the electric pole with the electroless nickel showed the lowest contact resistance among others. The resistance shows linear variation with regard to length. For the insulation and resolution, the glaze coating is best with 80% of water content. The temperature rising characteristic of the heating element is better than sheath heater saving 43% of rising time. The correlation equation for temperature was obtained with the electric power.