• Title/Summary/Keyword: National response system

Search Result 3,085, Processing Time 0.037 seconds

Dynamic and reliability analysis of stochastic structure system using probabilistic finite element method

  • Moon, Byung-Young;Kang, Gyung-Ju;Kang, Beom-Soo;Cho, Dae-Seung
    • Structural Engineering and Mechanics
    • /
    • v.18 no.1
    • /
    • pp.125-135
    • /
    • 2004
  • Industrial structure systems may have nonlinearity, and are also sometimes exposed to the danger of random excitation. This paper proposes a method to analyze response and reliability design of a complex nonlinear structure system under random excitation. The nonlinear structure system which is subjected to random process is modeled by finite element method. The nonlinear equations are expanded sequentially using the perturbation theory. Then, the perturbed equations are solved in probabilistic methods. Several statistical properties of random process that are of interest in random vibration applications are reviewed in accordance with the nonlinear stochastic problem.

A Study of Traffic Signal Progression on a CBD for Reducing Traffic Signal Cycle as Expansion of Permissive Left-Turn (비보호좌회전 확대에 따른 주기감소가 도심연동체계에 미치는 영향 연구)

  • Jung, Jin-Hyoung;Kwon, Young-Suk;Choi, Ki-Joon
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.559-565
    • /
    • 2016
  • For the purpose of the research, it is analyze the influence traffic Signal Progression on a CBD by expansion of Permissive Left-Turn on the advanced traffic management system program compared with traffic response control For this, divided a average distance between intersections, a traffic network on five district in four city. As the result, Volume of the traffic management system on a advanced traffic management system program compared with traffic response control is effective in traffic signal cycle 160sec 286car per lane, in 140sec 308car, 120sec 264car. As well, for a traffic network as the length of a traffic network 2.0~3.0km, under 2.0km, all of traffic signal cycle(160sec, 140sec, 120sec) a passing band and stop is more effective. But the traffic management system on traffic response control compared with the traffic management system on a advanced traffic management system program is effective in the length of a traffic network over 5.0km. For the efficiency of traffic signal system manage, it should be runned the traffic management system on traffic response control in addition to the traffic management system on a advanced traffic management system program on CBD. As the result of simulation the business in chungju-si, the travel speed of the traffic management system on a advanced traffic management system program is 41.2km/h and the travel speed of traffic response control is 37.5km/h. Therefore, it should be runned per length of a traffic network the traffic management system on traffic response control in addition to the traffic management system on a advanced traffic management system program on CBD.

Oil Spill Response System using Server-client GIS

  • Kim, Hye-Jin;Lee, Moon-Jin;Oh, Se-Woong
    • Journal of Navigation and Port Research
    • /
    • v.35 no.9
    • /
    • pp.735-740
    • /
    • 2011
  • It is necessary to develop the one stop system in order to protect our marine environment rapidly from oil spill accident. The purpose of this study is to develop real time database for oil spill prediction modeling and implement real time prediction modelling with ESI and server-client GIS based user interface. The existing oil spill prediction model cannot provide one stop information system for public and government who should protect sea from oil spill accident. The development of multi user based information system permits integrated handling of real time meteorological data from external ftp. A server-client GIS based model is integrated on the basis of real time database and ESI map to provide the result of the oil spill prediction model. End users can access through the client interface and request analysis such as oil spill prediction and GIS functions on the network as their own purpose.

Study on the Effective Stiffness of Base Isolation System for Reducing Acceleration and Displacement Responses

  • Kim, Young-Sang
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.586-594
    • /
    • 1999
  • To limit both the large displacement and acceleration response of the structure efficiently, the relationships between acceleration and displacement responses of the structure under several earthquakes are investigated for various horizontal stiffness of the base isolation system to determine the effective stiffness of the base isolation system in this paper. An example structure is a five-storey steel frame building as the primary structure and the secondary structures are assumed to be located on the fifth floor of the primary structure. Input motions used in the structural analysis are El Centre 1940, Taft 1952, Mexico 1985, San Fernando 1971 Pacoima Dam, and artificially generated earthquakes. The relationships of the absolute peak acceleration and the displacement at the top of the structure are calculated for various natural periods of base isolators under various earthquakes. The peak acceleration response of the fifth floor in the base isolated structure is significantly reduced by a factor of 2.1 through 6.25. Also, the relative displacement response of the floor to the base of the superstructure is very small. The results of this study can be utilized to determine the effective stiffness of the base isolation system.

  • PDF

Approximate Response of a Non-linear Vibration Isolation System Using the Harmonic Balance Method (하모닉 밸런스법을 이용한 비선형 진동절연 시스템의 근사적 응답)

  • Lee, Gun-Myung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.124-129
    • /
    • 2018
  • A non-linear vibration isolation system which is composed of a non-linear spring and a linear damper was proposed in past research. When the support of the isolation system is excited harmonically, the response component of the isolation system mass at the excitation frequency has been calculated approximately using the harmonic balance method. The response was approximated by a single mode, and the result was compared with a numerical result which is assumed as an accurate one. Next, the response was approximated by two modes, and the result was compared with the former one.

Design of Robust Linear Multivariable Optimal Model Following Servo System Incorporating Feedforward Compensator (피이드포워드 보상기를 갖는 강인한 선형 다변수 최적 모델 추종 서보계의 구성에 관한 연구)

  • Hwang, C.S.;Kim, C.T;Kim, D.W.;Kim, M.S.;Lee, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.338-340
    • /
    • 1993
  • In this paper, the method for designing a robust linear multivariable model following servo system is proposed. This model following servo system for the (n)th order reference input and the (n)th order disturbance is treated, and is designed so that the (n)th order response of the plant should be kept close to the (n)th order response of the given model by LQ(Linear Quadratic) optimal regulator approach. It is proved that the characteristics of the model following servo system is robust in the presence of the disturbances and the parameter perturbations of the plant dynamics.

  • PDF

Control techniques for improving response of the AVR (AVR의 응답속도개선을 위한 제어기법에 관한 연구)

  • Lee, Hyung-ki;Kim, Song-Hyun;Kim, Hyun-soo;Kim, Gi-ryang;Kim, Gwan-Hyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2534-2539
    • /
    • 2015
  • Method for regulating voltage using a generator voltage regulating device (AVR) is divided in an existing analog system and a digital replacement. Typically, to adjust the voltage by using a brushless excitation system of the type to be reduced for a voltage change under all. The control method of the AVR as a PID (proportional-integral-differential) control method is widely used. However, the control scheme is to reduce the transient response of the control parameters of the controller to the control object. Therefore, if the control target should change, there is a problem, reset the parameters of the controller again. In this study, without having to reset the parameters of the controller for the parameter variations to be controlled iPID (intelligent PID) using a controller designed to obtain a generator AVR system voltage variation is small in response to full load is applied to and through simulations and experiments improved transient response.

Dynamic Response based Reliability Analysis of Structure with Passive Damper - Part 1: Assessment of Member Failure Probability (수동형 댐퍼를 장착한 구조물의 동적응답기반 신뢰성 해석 - 제1편: 부재별 파괴확률 산정)

  • Kim, Seung-Min;Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.90-96
    • /
    • 2016
  • This study proposes a dynamic reliability analysis of control system as a method of quantitative evaluation of its performance in probabilistic terms. In this dynamic reliability analysis, the failure event is defined as an event that the dynamic response of the structural system exceeds a displacement limit, whereas the conventional reliability analysis method has limitations that do not properly assess the actual time history response of the structure subjected to dynamic loads, such as earthquakes and high winds, by taking the static response into account in the failure event. In this first paper, we discuss the control effect of the viscous damper on the seismic performance of the member-level failure where the failure event of the structural member consists of the union set of time-sequential member failures during the earthquake excitations and the failure probability of the earthquake-excited structural member is computed using system reliability approach to consider the statistical dependence of member failures between the subsequent time points. Numerical results demonstrate that the proposed approach can present a reliable assessment of the control performance of the viscous damper system in comparison with MCS method. The most important advantage of the proposed approach can provide us more accurate estimate of failure probability of the structural control system by using the actual time-history responses obtained by dynamic response analysis.

A Parametric Study on the Seismic Response Analysis of LNG Storage Tank with Disconnected Pile Foundation Subjected to Horizontal Seismic Input Considering Fluid-Structure-Soil Interaction (유체-구조물-지반 상호작용을 고려한 비결합 말뚝기초에 지지된 LNG 저장탱크의 수평지진입력에 대한 지진응답 매개변수해석)

  • Son, Il-Min;Kim, Jae-Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.21-32
    • /
    • 2024
  • This study performed the seismic response analysis of an LNG storage tank supported by a disconnected piled raft foundation (DPRF) with a load transfer platform (LTP). For this purpose, a precise analytical model with simultaneous consideration of Fluid-Structure Interaction (FSI) and Soil-Structure Interaction (SSI) was used. The effect of the LTP characteristics (thickness, stiffness) of the DPRF system on the seismic response of the superstructure (inner and outer tanks) and piles was analyzed. The analytical results were compared with the response of the piled raft foundation (PRF) system. The following conclusions can be drawn from the numerical results: (1) The DPRF system has a smaller bending moment and axial force at the head of the pile than the PRF system, even if the thickness and stiffness of the LTP change; (2) The DPRF system has a slight stiffness of the LTP and the superstructure member force can increase with increasing thickness. This is because as the stiffness of the LTP decreases and the thickness increases, the natural frequency of the LTP becomes closer to the natural frequency of the superstructure, which may affect the response of the superstructure. Therefore, when applying the DPRF system, it is recommended that the sensitivity analysis of the seismic response to the thickness and stiffness of the LTP must be performed.

PD+I-type fuzzy controller using Simplified Indirect Inference Method

  • Kim, Ji-Hoon;Jeon, Hae-Jin;Chun, Kyung-Han;Park, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.179.5-179
    • /
    • 2001
  • Generally, while PD-type fuzzy controller has good performance in transient period, it has uniform steady state error of response. To improve limitations of PD-type fuzzy controller, we propose a new fuzzy controller to improve the performance of transient response and to eliminate the steady state error of response. In this paper, PD-type fuzzy controller is used a simplified indirect inference method(SIIM). When the SIIM is applied, the proposed method has the capability of the high speed inference and adapting with increasing the number of the fuzzy input variables easily. The outputs of this controller are the output calculated by PD-type fuzzy controller and the accumulated error scaling factor. Here, the accumulated error scaling factor is adjusted by fuzzy rule according to the system state variables. To show the usefulness of the proposed controller, it is applied to 0-type 2nd-order linear system.

  • PDF