• Title/Summary/Keyword: National measurements standards

Search Result 169, Processing Time 0.027 seconds

APMP (Asia Pacific Metrology Programme) Regional Intercomparison Results of Acoustic Calibrators (음향교정기의 아시아.태평양 지역 국제비교 결과)

  • 서상준;서재갑;조문재
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.463-471
    • /
    • 2003
  • The results of the APMP (Asia Pacific Metrology Programme) regional intercomparison of acoustic calibrators were reviewed and analyzed. The artefacts used in intercomparison are a sound level calibrator and a pistonphone. The microphones used to measure the output pressure level are 1" and 1/2" standard microphones (LS1P, LS2P) as well as 1" and 1/2" reference microphones (WS1P/F, WS2P/F). The results obtained using standard microphones are satisfactory, but those obtained by the reference microphones, even though E/sub n/ values are within ±1.0, showed great deviations. Such results had come from the inaccurate calibration of reference microphones. By using the correct calibration results which were obtained by the recently established international standards, the new results were very similar to those of the foreign standard institutes.

A Case Study on the Air Quality Impact Assessment for the Large Scale Urban Development (대규모 도시개발사업에 대한 대기질 평가 사례 연구)

  • Kim, Sang-Mok;Lee, Sang-Hun;Park, Keun-Hyoung;Woo, Jae-Kyun;Koo, Youn-Seo;Kim, Sung-Tae;Han, Jin-Seok
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.6
    • /
    • pp.381-391
    • /
    • 2007
  • The air quality modeling was carried out to assess the impact of air quality for large scale urban development. The site for the assessment is Multi-fuctional Administrative City which locates in Yeongi-gun, Chungcheongnam-do and estimated population in 2030 is 500,000. Two automatic weather monitoring stations were installed to monitor the meteorological variables for a year and upper air meteorological parameters were measured using radiosonde for 5 days with 4 hours interval in every season. The air quality of standard air pollutants were also measured for 5 days continuously in every season. The results of wind field analysis based on the site measurements and CALMET modeling showed that the valley and mountain winds were prevailed when the sypnotic wind was weak. It also showed that wind speed and directions were highly space-variable within the site basin. The variable wind characteristics implies that the Gaussian dispersion model such ISC3 and AERMOD are not appropriate and the unsteady-sate Lagrangian model such as CALPUFF is preferable. CALPUFF model was applied to assess air quality impact of new sources. The new sources were those for individual and group heating facilities as well as the traffic increases. The results showed that the estimated concentrations of CO and $SO_2$ pollutants by summing the impact concentration of new sources by the dispersion model and the ambient air concentrations by the site measurements were acceptable but those of PM-10 and $NO_2$ would violate ambient air quality standards at several locations due to high ambient air concentrations. It is recommended that the emission reductions near the site should be enforced to improve the ambient air quality.

Packet Data Performance Measurement in D-TRS Wireless Network Environment (D-TRS 무선망 환경에서의 패킷 데이터 성능 측정)

  • Song, Byung-Kwen;Jin, Myung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.6
    • /
    • pp.902-908
    • /
    • 2009
  • TETRA is the standard of Digital Trunked Radio System developed by the ETSI (European Telecommunications Standards Institute). It is currently adopted as Electric Power IT Wireless Backbone Network in Korea, and a national enterprise is going on for versatile utilization of TETRA. To use TETRA wireless network, TETRA modem is very necessary such that performance measurements are very crucial for each TETRA modem by various manufacturers. In this paper, PED (Protocol Evaluation Data) is suggested for PD performance measurement in D-TRS wireless network environment. The performance measurements for different data lengths and transmission intervals are done using TG (Traffic Generator) on Test Bed. The data size is increased by 10 bytes from 10-byte to 400-byte, and it is measured 1,000 times for each transmission interval of 0.5, 1.0, and 1.5 seconds. Based on the transmission time measured, average transmission speed and MER (Message Error Rate) are derived for TETRA Modem performance measurement. Two TMR880i's of EADS are used for TETRA modem, and SwMI (Switching and Management Infrastructure) of EADS is used for switching system in this paper.

New Programmable RF DFT Circuit for Low Noise Amplifiers (LNA를 위한 새로운 프로그램 가능 고주파 검사용 설계회로)

  • Ryu, Jee-Youl;Noh, Seok-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.4
    • /
    • pp.28-39
    • /
    • 2007
  • This paper presents a programmable RF DFT (Radio Frequency Design-for-Testability) circuit for low noise amplifiers. We have developed a new on-chip RF DFT circuit that measures RF parameters of low noise amplifier (LNA) using only DC measurements [1, 2]. This circuit is extremely useful for today's RFIC devices in a complete RF transceiver environment. The DFT circuit contains test amplifier with programmable capacitor banks and RF peak detectors. The test circuit utilizes output DC voltage measurements and these measured values are translated into the LNA specifications such as input impedance and gain using the mathematical equations. Our on-chip DFT circuit can be self programmed for 1.8GHz, 2.4GHz and 5.25GHz low noise amplifiers for GSM, Bluetooth and IEEE802.11g standards. The circuit is simple and inexpensive.

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.8 no.4
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

Comparison of OC and EC Measurement Results Determined by Thermal-optical Analysis Protocols (열광학적 분석 프로토콜에 의한 유기탄소와 원소탄소 측정값 비교)

  • Kim, Hyosun;Jung, Jinsang;Lee, Jinhong;Lee, Sangil
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.449-460
    • /
    • 2015
  • Carbonaceous aerosol is generally classified into OC (organic carbon) and EC (elemental carbon) by thermal optical analysis. Both NIOSH (National institute of occupational safety and health) with high temperature (HighT) and IMPROVE-A (Interagency monitoring of protected visual environments) with low temperature (LowT) protocols are widely used. In this study, both protocols were applied for ambient $PM_{2.5}$ samples (Daejeon, Korea) in order to underpin differences in OC and EC measurements. An excellent agreement between NIOSH and IMPROVE-A protocol was observed for TC (total carbon). However, significant differences between OC and EC appeared and the differences were larger for EC than OC. The main differences between two protocols are temperature profile and charring correction method. For the same charring correction method, HighT_OC was 10% higher than LowT_ OC, while HighT_EC was 15% and 33% lower than LowT_EC for TOT (thermal-optical transmittance) and TOR (thermal-optical reflectance), respectively. This difference may be caused by the temperature of OC4 in He step and possibly difference in POC (pryorilized OC) formation. For the same temperature profile, OC by TOT was about 26% higher than that by TOR. In contrast, EC by TOT was about 50% lower than that by TOR. POC was also dependent on both temperature profile and the charring correction method, showing much distinctive differences for the charring correction method (i.e., POC by TOT to POC by TOR ratio is about 2). This difference might be caused by different characteristics between transmittance and reflectance for monitoring POC formation within filters. Results from this study showed that OC and EC depends on applied analysis protocol as shown other studies. Because of the nature of the thermal optical analysis, it may not be possible to have an absolute standard analysis protocol that is applicable for any ambient $PM_{2.5}$. Nevertheless, in order to provide consistent measurement results for scientists and policy makers, future studies should focus on developing a harmonized standard analysis protocol that is suitable for a specific air domain and minimizes variations in OC and EC measurement results. In addition, future elaborate studies are required to find and understand the causes of the differences.

A LONGITUDINAL CEPHALOMETRIC STUDY OF THE CRANIOFACIAL GROWTH CHANGES OF ADOLESCENCE WITH NORMAL OCCLLUSION (청소년기 정상교합자의 악안면 성장에 관한 두부방사선 규격사진 분석에 의한 누년적 연구(Ricketts분석법에 의한 연구))

  • KIM, Yun-Jeong;Park, Kyung-Duk;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.287-297
    • /
    • 1995
  • This study was performed to establish the cephalometric standards and growth changes necessary to create the Growth Forecast without Treatment at adolescence. The data from biennial serial cephalometric radiographs of 25 male and 21 female subjects aged from 8 to 16 years of Normal Koreans were used for this study. The following results were obtained. 1. There were no significant value changes of facial axis angle, fn to palatal plane angle, BA-NA-A angle, lower facial height and lower incisor protrusion as the age increased. 2. From continuous increasing measurements(anterior and posterior cranial babe length, facial axis length, condyle axis length, corpus axis length), the annual growth changes, average annual growth changes and changes for 8 years were obtained. 3. From continuous increasing measurements, significant differences were observed between male and female subjects in most annual growth changes after age of 12 years, average annual growth changes and changes for 8 years (p<0.05). 4. All linear and angular measurements were plotted by using X-Y plotter and personal computer. The visual norms for both sexes were obtained. There was considerable growth, for male, for each period especially the most remarkable growth from the age of 12 to 14. For female, the upmost growth was showed from the age of 10 to 12, and gradually decreased since then.

  • PDF

Evaluation of the Concentration Distribution and the Contamination Influences for Beryllium, Cobalt, Thallium and Vanadium in Soil Around the Contaminated Sources (오염원 인근 토양 중 베릴륨(Be), 코발트(Co), 탈륨(Tl), 바나듐(V)의 농도분포 및 오염영향 평가)

  • Lee, Hong-gil;Noh, Hoe-Jung;Yoon, Jeong Ki;Lim, Jong-hwan;Lim, Ga-Hee;Kim, HyunKoo;Kim, Ji-in
    • Journal of Soil and Groundwater Environment
    • /
    • v.23 no.4
    • /
    • pp.48-59
    • /
    • 2018
  • Beryllium (Be), cobalt (Co), thallium (Tl) and vanadium (V) are candidates of 21 priority soil pollutants in Korea. The distribution of their concentration in soils from three contamination sources including industrial, roadside and mining areas was investigated. Concentrations of the metals were evaluated quantitatively using pollution indices and the fractionation of metals was conducted using modified SM&T (Standards Measurements and Testing programme) sequential extraction. Concentrations of the metals for all samples from industrial and roadside soils were within the range of natural background levels, while some of Be in soils from abandoned mines exceeded that the range. Enrichment Factor (EF) and Nemerow Integrated Pollution Index (NIPI) for Be, Co, Tl and V showed that there are effects or possibilities of anthropogenic activities. Pollution Load Index (PLI) analyses indicated all investigated sites needed further monitoring. The results of sequential extractions indicated mobile fractions (F1+F2) of Be, Tl and V were below 30% except some of Co in soil, which implies their low mobility to neighboring environment media. Variable tools like sequential extraction, comparison with background/actual concentration and pollution indices, as well as aqua regia extraction should be considered when evaluating Be, Co, Tl, V in soil.

Improved accuracy in periodontal pocket depth measurement using optical coherence tomography

  • Kim, Sul-Hee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Jun-Min;Yi, Won-Jin;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • Purpose: The purpose of this study was to examine whether periodontal pocket could be satisfactorily visualized by optical coherence tomography (OCT) and to suggest quantitative methods for measuring periodontal pocket depth. Methods: We acquired OCT images of periodontal pockets in a porcine model and determined the actual axial resolution for measuring the exact periodontal pocket depth using a calibration method. Quantitative measurements of periodontal pockets were performed by real axial resolution and compared with the results from manual periodontal probing. Results: The average periodontal pocket depth measured by OCT was $3.10{\pm}0.15mm$, $4.11{\pm}0.17mm$, $5.09{\pm}0.17mm$, and $6.05{\pm}0.21mm$ for each periodontal pocket model, respectively. These values were similar to those obtained by manual periodontal probing. Conclusions: OCT was able to visualize periodontal pockets and show attachment loss. By calculating the calibration factor to determine the accurate axial resolution, quantitative standards for measuring periodontal pocket depth can be established regardless of the position of periodontal pocket in the OCT image.

Purity assignment of 17α-hydroxyprogesterone by mass balance method to establish traceability in measurement

  • Lee, Hwa Shim;Park, Su Jin
    • Analytical Science and Technology
    • /
    • v.32 no.6
    • /
    • pp.225-232
    • /
    • 2019
  • Traceability establishment in chemical measurements is a like a linkage established through an unbroken chain from the measured results to the international system (SI) of units. The primary process for traceability establishment is the purity assignment of a target material to be measured. In this study, we studied the purity assignment of 17α-hydroxyprogesterone (17-OHP). The presence of 17-OHP is indicative of congenital adrenal hyperplasia (CAH) and it builds up due to the deficiency of 21-hydroxylase and 11β-hydroxylase enzyme in the human blood. The purity assignment of 17-OHP was performed by the mass balance method, in which the impurities are categorized into four classes: total related structural impurities, water, residual organic solvents, and nonvolatiles/inorganics. The total related structural impurities were characterized by HPLC-UV; water content was determined by Karl-Fisher coulometer; and the total residual solvents and nonvolatiles/inorganics were determined by TGA. The purity of 17-OHP from a commercial manufacturer was calculated as 993.30 mg/g, and the expanded uncertainty was 0.58 mg/g. The proposed method was validated by uncertainty evaluation and comparing with the actual value of purity.