• Title/Summary/Keyword: National Power

Search Result 19,176, Processing Time 0.049 seconds

Analysis of Laser-protection Performance of Asymmetric-phase-mask Wavefront-coding Imaging Systems

  • Yangliang, Li;Qing, Ye;Lei, Wang;Hao, Zhang;Yunlong, Wu;Xian'an, Dou;Xiaoquan, Sun
    • Current Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • Wavefront-coding imaging can achieve high-quality imaging along with a wide range of defocus. In this paper, the anti-laser detection and damage performance of wavefront-coding imaging systems using different asymmetric phase masks are studied, through modeling and simulation. Based on FresnelKirchhoff diffraction theory, the laser-propagation model of the wavefront-coding imaging system is established. The model uses defocus distance rather than wave aberration to characterize the degree of defocus of an imaging system. Then, based on a given defocus range, an optimization method based on Fisher information is used to determine the optimal phase-mask parameters. Finally, the anti-laser detection and damage performance of asymmetric phase masks at different defocus distances and propagation distances are simulated and analyzed. When studying the influence of defocus distance, compared to conventional imaging, the maximum single-pixel receiving power and echo-detection receiving power of asymmetric phase masks are reduced by about one and two orders of magnitude respectively. When exploring the influence of propagation distance, the maximum single-pixel receiving power of asymmetric phase masks decreases by about one order of magnitude and remains stable, and the echodetection receiving power gradually decreases with increasing propagation distance, until it approaches zero.

Development of Automatic Power Measurement System for Electrosurgical Unit (전기 수술기 파워 자동 측정 시스템 개발)

  • Kim, SooHong;Yun, SungUk;Joh, MyoungHun;Jeon, GyeRok
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.4
    • /
    • pp.183-189
    • /
    • 2017
  • Electrosurgical Unit(ESU) is medical equipment that cut or coag tissues using electrical energy. It is used in hospitals' outpatient clinic room and operating room. Improper use of an ESU may cause fatal injuries to the patient, such as burns. So, before using an ESU, make sure that it is supplying enough energy for cut and coag by measuring the output power and checking the output power cable. In this study, we developed a simple ESU power measurement system PW100 that allows anyone to check the basic output power. And PW100 can check the state of the cable associated with the output power before using ESU. Then, we compared the measured output power of the PW100 with an ESU Analyzer which was commercialized, and compared the performance. In the experiment, the output power measured by the PW100 was lower value than an ESU Analyzer's that. However, the PW100's output power measured in the 5% error range and showed stable reproducibility by a low %RSD value.

Analysis of losses within SMES system for compensating output fluctuation of wind power farm

  • Park, S.I.;Kim, J.H.;Le, T.D.;Lee, D.H.;Kim, D.J.;Yoon, Y.S.;Yoon, K.Y.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.57-61
    • /
    • 2014
  • Output fluctuation which is generated in wind power farm can hinder stability of total power system. The electric energy storage (EES) reduces unstable output, and superconducting magnetic energy storage (SMES) of various EESs has the proper performance for output compensation of wind power farm since it charges and discharges large scale power quickly with high efficiency. However, because of the change of current within SMES, the electromagnetic losses occur in the process of output compensation. In this paper, the thermal effect of the losses that occur in SMES system while compensating in wind power farm is analyzed. The output analysis of wind power farm is processed by numerical analysis, and the losses of SMES system is analyzed by 3D finite element analysis (FEA) simulation tool.

Power Quality Control of Wind/Diesel Hybrid Power Systems Using Fuzzy PI Controller (퍼지 PI 제어기를 이용한 풍력/디젤 하이브리드 발전시스템의 품질제어)

  • Yang, Su-Hyung;Ko, Jung-Min;Boo, Chang-Jin;Kang, Min-Jae;Kim, Jeong-Uk;Kim, Ho-Chan
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.5
    • /
    • pp.1-10
    • /
    • 2012
  • This paper proposes a modeling and controller design approach for a wind-diesel hybrid system including dump load. Wind turbine depends on nature such as wind speed. It causes power fluctuations of wind turbine. Excessive power fluctuation at stand-alone power grid is even worse than large-scale power grid. The proposed control scheme for power quality is fuzzy PI controller. This controller has advantages of PI and fuzzy controller. The proposed model is carried out by using Matlab/Simulink simulation program. In the simulation study, the proposed controller is compared with a conventional PI controller. Simulation results show that the proposed controller is more effective against disturbances caused by wind speed and load variation than the PI controller, and thus it contributes to a better quality wind-diesel hybrid power system.

Reliability Evaluation of Power system considering Wind Turbine Generators and Multi-Energy Storage System In JeJu Island (풍력발전원과 다개 ESS를 고려한 제주도 계통에서의 신뢰도 평가)

  • Oh, Ungjin;Lim, Jintaek;Lee, Yeonchan;Phuong, Do Nguyen Duy;Choi, Jaeseok;Yoon, Yongbeum;Chang, Byunghoon;Cho, Sungmin
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.473-474
    • /
    • 2015
  • This paper proposes probabilistic reliability evaluation model of power system considering Wind Turbine Generator(WTG) integrated with Energy Storage System(ESS). Monte carlo sample state duration simulation method is used for the evaluation. The power output from WTG units usually fluctuates randomly. Therefore, the power cannot be counted on to continuously satisfy the system load. Although the power output at any time is not controllable, the power output can be utilized when needed if ESS is available. The ESS may make to smooth the fluctuation of the WTG power output. The detail process of power system reliability evaluation considering Multi-ESS cooperated WTG is presented using case study of Jeju island power system in the paper.

  • PDF

A Study on PV Power Generation System Adding the Function of Shunt Active Filler Using DSP (DSP를 이용한 엑티브 필터 기능 추가형 태양광발전시스템의 운전특성에 관한 연구)

  • Seo, Hyo-Ryong;Park, Young-Gil;Kim, Jong-Hyun;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1169-1170
    • /
    • 2006
  • Grid connected PV(Photovoltic) generation systems are becoming and actual and general. The power output of PV system is directly affected by the weather conditions. And when AC power supply is needed, power conversion by an inverter and a MPPT control are necessary. The PV power generation system can be treated to a harmonics source for the power distribution system. So, the PV system combined the function of active filter system can be useful applied in power distribution system. AF(Active Filters) intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer. With the test analysis of the proposed control strategy of PV-AF system, the outcome of the test shows the stability and effectiveness of the proposed PV-AF system. The various capability of AF has been proved in previous research and usage. In this paper, authors present a DSP controlled PV-AF system for power conditioning in three-phase industrial or commercial power systems and verify it through experimental results.

  • PDF

Maximum Efficiency Point Tracking Control Algorithm for Improving Electric Power Transmission Efficiency between Photovoltaic Power Generating system and the Grid (태양광발전시스템과 계통간의 전력 전송 효율 개선을 위한 최대효율점 추적 제어 알고리즘)

  • Kwon, Cheol-Soon;Kim, Kwang Soo;Do, Tae Young;Park, Sung-Jun;Kang, Feel-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.342-348
    • /
    • 2013
  • It proposes an efficient control algorithm to increase electric power transmission efficiency between photovoltaic power generating system and the grid. The main controller finds a maximum efficiency condition by considering the quantity of power generated from PV arrays, the number of inverters, and efficiency of PV inverter. According to the condition, a relay board arranges a point of contract of PV arrays. By the disposition of PV arrays, it assigns the optimized power on each PV inverter. Operational principle of the proposed maximum efficiency point tracking algorithm is given in detail. To verify the validity of the proposed approach, computer-aided simulation and experiment carried out.

A Brief Scrutiny of Malawi's Policy on Nuclear Power

  • Katengeza, Estiner Walusungu
    • Journal of Radiation Protection and Research
    • /
    • v.45 no.4
    • /
    • pp.147-153
    • /
    • 2020
  • Background: Malawi's 2018 National Energy Policy includes nuclear power as an energy option with an operational 100 MW targeted for 2035. Materials and Methods: This paper challenges the scope of the policy on nuclear power by reviewing its implementation strategy and comparing it to: the strategy established for coal in the same policy; some experiences from other countries; and documents by the International Atomic Energy Agency (IAEA) relating to establishing a national position on nuclear power and infrastructural requirements for a nuclear power program. Results and Discussion: It is found that the pro-nuclear position is uninformed, and targets are unrealistic owing to a lack of understanding of nature of nuclear power including the requirements for safety, security and safeguards, and nuclear infrastructure. It is apparent that neither consultation nor a proper analysis were comprehensively conducted for nuclear. Though the national energy policy suggests a national position for nuclear energy, the content does not demonstrate that the position was arrived at knowledgeably. Conclusion: Thus, nuclear power may presently be viewed as a potential energy option that is yet to be seriously considered. It is important to build an appropriate level of literacy on nuclear science and technology for policy makers, key stakeholders, and the public to be better positioned for strategizing on nuclear power.

Power Quality Measurement and Analysis of Extra-High Voltage Customer (특고압 수용가의 전력품질 측정 및 분석)

  • Cho, Jae-Hyeong;Lee, Jong-Pil;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.286-290
    • /
    • 2015
  • Power system is composed of a number of power devices and equipment. This factor affects the power quality is also displayed very complicated and varied. The accurate measurement and analysis of the causes of power quality problems is difficult. In preparing for these issues, there are many difficulties. In this study, Power quality of A public establishment of Chungbuk province were measured and analyzed. Measurement results of the fifth harmonic current was very large. Accordingly, the harmonic reduction will be needed. This research will be utilized as fundamental data to improve power quality for power utility and customer.

Implementation of inside the computer power supply with UPS (UPS 기능을 갖는 내장형 컴퓨터 전원장치의 구현)

  • Lee S. R.;Ko S. S.;Mun J. M.;Kwon H. D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.202-205
    • /
    • 2003
  • Recently, UPS(Uninterruptible Power Supply) have been largely used to improve power souse quality as well as to protect critical loads such as computer, industrial system, medical equipment, etc, against power outage by providing clean and uninterrupted power under power supply disturbance or interruptions. But UPS is bulky because used battery. So, UPS size issue have received attention in the power electronics industry. Therefore, this paper proposed a implementation of inside of the computer power supply with UPS by the one-chip microprocessor to minimize UPS size. To verify the proposed power supply, the detail simulation and experiment results indicate that high-frequency switching and operation UPS can be achieved.

  • PDF