Realization of Primary Thermometer from Electrical Shot Noise in a Metal-Insulator-Metal Tunnel Junction (Metal-Insulator-Metal 터널접합의 산탄잡음을 이용한 일차 온도계 구현)

  • Park, J.H.;Rehman, M.;Choi, J.S.;Khim, Z.G.;Ryu, S.W.;Song, W.;Chong, Y.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.96-99
    • /
    • 2010
  • We measured electrical shot noise in a metal-insulator-metal tunnel junction, which was made by using electron-beam lithography and double-angle evaporation technique. Since the dependence of the shot noise on bias voltage and temperature is theoretically well known, we can determine the temperature of the junction by measuring the noise as the voltage across the junction is changed. A cryogenic low noise amplifier was used to amplify the noise signal in the frequency range of 600-800 MHz, which enabled fast measurement of noise signal and thus temperature. With further study, this method could be useful for primary thermometry in cryogenic temperatures.

Improvement of Measuring Capacity of the DC High-voltage Divider for a National High-voltage Standard (국가 고전압 표준용 직류고전압 분압기의 측정능력 향상)

  • Lee, Sang-Hwa;Jang, Seok-Myeong;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1622-1625
    • /
    • 2014
  • The main measurement uncertainty factors in DC high-voltage dividers for a national high-voltage standard are the measurement uncertainty of low-voltage arm and the stability of a high-voltage supply. In this study, the uncertainties by the two factors are greatly improved. As a result the measurement uncertainty for the DC high-voltage divider is reduced from $16{\times}10^{-6}(k=2)$ to $8{\times}10^{-6}(k=2)$ which is at international level.

Sizing System Development of Korean Structural Firefighting Protective Clothing (한국 소방용 방화복의 치수체계 개발)

  • Han, Sul-Ah;Nam, Yun-Ja;Choi, Young-Lim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.5
    • /
    • pp.827-839
    • /
    • 2009
  • Sizing system of Korean structural firefighting protective clothing that is national approved should be met for specification of structural firefighting protective clothing that is identified by Ministry of Public Administration and Security(MOPAS). However if you look over the specification of sizing system, the standard is based on only 'height' and the others are indicated as the size of completed product. KS K ISO 13688 and EN 340 which is met on ISO 13688 which indicates sizing system about protective clothing has the standards of height, chest and waist circumference. Also NFPA 1971 that has standards of sizing system is based on chest circumference, cervical to wrist length, waist circumference and inseam. That is different from Korean standards. Therefore, fire fighting protective clothing standards which is based on only height should be compensated and not be relied on foreign standards like ISO. It is indispensable for developing our own sizing system of structural fire fighting protective clothing. In this studying, Korean new sizing system of structural fire fighting protective clothing was developed for providing basic information of ergonomic structural fire fighting protective clothing. The analyzed target age was between 20 and 59 years old fire fighter who extinguish the fire. And it was analyzed by 3D measurement among data of the $5^{th}$ Size Korea. On conclusion, in case of structural fire fighting protective clothing coat, physical dimension was to be chest circumference, cervical to wrist length. Three dimensions as 5cm space of circumference and four dimensions as 2.5cm space of cervical to wrist length were derived, which means that totally 12 dimensions were defined. Dimension standards of pants was based on the analysis of waist circumference and crotch height. Six dimensions as 5cm space of waist circumference and three dimensions as 5cm space of crotch height were derived, which means that totally 14 dimensions were defined.

Energy Efficient Wireless Data Transmission for Personal Health Devices

  • Kim, Sang-Kon;Kim, Tae-Kon;Koh, Jin-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1559-1570
    • /
    • 2013
  • The family of ISO/IEEE11073 standards is the basis of the e-health system and provides interoperability for personal health devices. In the early stage of e-health business, it was expected that people would use a health device individually. In this case, a measurement datum was episodically acquired and generally transmitted for one person at a time. Recently, a health device is expected to be used by multiple people, and large amounts of measurement data are gathered in a short time interval. In addition, mobile health devices have become more popular, so that energy efficient measurement data transmission is required, to prolong the use of a device. In IEEE11073 PHD standards, data transmission is classified into three different types: immediate individual transfer, small block transfer, and large block transfer. The large block transfer using PM-store concept provides efficient transmission. However, an existing PM-store has problem when a device is used by multiple people. To address the defined problem, a modified PM-segment that is in compliance with 11073 standards is proposed in this paper. In particular, the proposed PM-segment is designed to minimize the additional complexity of an agent instead of a manager and it is interoperable with the existing manager. The proposed PM-segment shows better performance than the existing PM-segment, in terms of memory requirements and expected queue time. Also, performance comparison among the three transfers is performed in regard to the delay time and communication power consumption points of view.

Roughness Measurement Performance Obtained with Optical Interferometry and Stylus Method

  • Rhee Hyug-Gyo;Lee Yun-Woo;Lee In-Won;Vorburger Theodore V.
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.1
    • /
    • pp.48-54
    • /
    • 2006
  • White-light scanning interferometry (WLI) and phase shifting interferometry (PSI) are increasingly used for surface topography measurements, particularly for areal measurements. In this paper, we compare surface profiling results obtained from above two optical methods with those obtained from stylus instruments. For moderately rough surfaces ($Ra{\approx}500\;nm$), roughness measurements obtained with WLI and the stylus method seem to provide close agreement on the same roughness samples. For surface roughness measurements in the 50 nm to 300 nm range of Ra, discrepancies between WLI and the stylus method are observed. In some cases the discrepancy is as large as 109% of the value obtained with the stylus method. By contrast, the PSI results are in good agreement with those of the stylus technique.

Development of a Maxwell-Wein Bridge for Precise Measurement of a 10 mH Inductance Standard (10 mH 인덕턴스 표준기 정밀측정용 Maxwell-Wein Bridge 개발)

  • Kim, Han-Jun;Lee, Rae-Duk;Kang, Jeon-Hong;Yu, Kwang-Min;Semenov, Yu.P.;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.769-771
    • /
    • 2000
  • 저 주파수에서 인덕턴스를 정밀하게 측정하는 방법은 RLC를 이용한 resonance 방법과 교류브리지를 이용한 방법이 있다. 현재 선진 국가표준기관에서의 인덕턴스 표준유지는 약 5 ppm정도이고, 인덕턴스 측정브리지는 국가에 따라 자체 개발하여 사용하며 평균적으로 약 20 ppm의 불확도로 보급을 하고 있다. 이러한 세계적 수준으로 인덕턴스 표준을 유지, 보급하기 위하여 10nF의 전기용량 표준으로부터 10 mH의 인덕턴스를 유도할 수 있는 Maxwell-wein bridge가 개발이 되었다. 이 브리지가 개발됨으로서 10 mH의 경우 400 Hz$\sim$5 kHz의 주파수 범위내에서 약 8 ppm($2{\sigma}$)의 불화도로서 인덕턴스 표준을 유지할 수가 있게 되었다.

  • PDF

Design of an Antireflection Coating for High-efficiency Superconducting Nanowire Single-photon Detectors

  • Choi, Jiman;Choi, Gahyun;Lee, Sun Kyung;Park, Kibog;Song, Woon;Lee, Dong-Hoon;Chong, Yonuk
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.375-383
    • /
    • 2021
  • We present a simulation method to design antireflection coating (ARCs) for fiber-coupled superconducting nanowire single-photon detectors. Using a finite-element method, the absorptance of the nanowire is calculated for a defined unit-cell structure consisting of a fiber, ARC layer, nanowire absorber, distributed Bragg reflector (DBR) mirror, and air gap. We develop a method to evaluate the uncertainty in absorptance due to the uncontrollable parameter of air-gap distance. The validity of the simulation method is tested by comparison to an experimental realization for a case of single-layer ARC, which results in good agreement. We show finally a double-layer ARC design optimized for a system detection efficiency of higher than 95%, with a reduced uncertainty due to the air-gap distance.

Rat Magnetocardiograms Measured by YBCO SQUID Magnetometer (YBCO SQUID를 이용한 실험쥐의 심자도 측정)

  • Ahn, San;Kim, I.S.;Song, J.H.
    • Progress in Superconductivity
    • /
    • v.12 no.2
    • /
    • pp.124-128
    • /
    • 2011
  • We have developed a high-$T_C$ SQUID magnetometer system to measure magnetocardiograms of laboratory rats. White noise of the measurement system was about 50 fT/$Hz^{1/2}$ when measured in a magnetically shielded box. We optimized the measurement position to obtain clear MCG wave from rat's small heart by using grid measurements. With the optimization, the MCG signal was successfully detected with the peak amplitude of about 50 pT. We could observe well defined P-, QRS-, and T-wave from the rat MCG. The results suggest that the developed system has a strong potential to monitor the progress of heart disease model using laboratory rat.

Cure Monitoring and Nondestructive Evaluation of Carbon Fiber/Epoxy Composites by the Measurements of Electrical Resistance and AE

  • Lee Sang-Il;Yoon Dong-Jin;Park Joung-Man
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.10a
    • /
    • pp.264-267
    • /
    • 2004
  • Cure monitoring and nondestructive characteristics of carbon fiber/epoxy composites were evaluated by the measurements of electrical resistance and acoustic emission (AE). Logarithmic electrical resistivity of the untreated single-carbon fiber composite increased suddenly to infinity when the fiber fracture occurred, whereas that of the electrodeposited composite increased relatively broadly up to infinity. As curing temperature increased. logarithmic electrical resistivity of steel fiber increased. On the other hand, electrical resistance of carbon fiber decreased due to the intrinsic electrical properties based on the band theory. The apparent modulus of the electrodeposited composite was higher than that of the untreated composite due to the improved interfacial shear strength (IFSS).

  • PDF

Effects of Fan-Aspirated Radiation Shield for Temperature Measurement in Greenhouse Environment

  • Yang, Seung-Hwan;Lee, Chun-Gu;Kim, Joon-Yong;Lee, Won-Kyu;Ashtinai-Araghi, A.;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.4
    • /
    • pp.245-251
    • /
    • 2012
  • Purpose: Provision of accurate temperature measurement is an essential element to ensure a precise control in greenhouse environment. This study was organized to compare the effects of six solar radiation shields with different shapes for temperature measurement and find the most appropriate shield for greenhouse environment. Methods: A fan-aspirated radiation shield was designed and manufactured. Using the fan-aspirated radiation shield and five other shapes i.e., the cup shape, horizontal pipe, vertical pipe, parallel boards and commercial shields, temperature measurement was conducted over the lawn surface as well as greenhouse indoor environment. The measurement height varied at 0.5, 1.0 and 1.5 m from the floor. Results: The measured temperatures by the fan-aspirated radiation shield were 1.30-$1.49^{\circ}C$ lower than the values recorded by other different-shaped shields at 1.5 m of measurement height. As the measurement height decreases, observed differences between measured temperatures of the fan-aspirated radiation shield and other shields demonstrate a declining trend. However, at low measurement heights, the radiation emitted from the bottom surface would be the source of error in temperature measurement. Conclusions: The fan-aspirated radiation shield is a required tool for exact measurement of air temperature in greenhouse temperature control.