• Title/Summary/Keyword: National Forensic Service

Search Result 190, Processing Time 0.024 seconds

The Application of Paewinsky et al.'s Age Estimation Method to Periapical Radiographs (치근단 방사선 사진에서 Paewinsky 연령추정법 적용에 대한 연구)

  • Roh, Byung-Yoon;Seo, Jeong-Uk;Kim, Chang-Gyum;Choi, Chang-Un;Lee, Won-Joon;Lee, Sang-Seob
    • The Korean Journal of Legal Medicine
    • /
    • v.42 no.4
    • /
    • pp.141-145
    • /
    • 2018
  • There have been many radiographic studies on age estimation that evaluate reduction in size of dental pulp cavity with secondary dentin formation. The Paewinsky method reported high accuracy in estimating ages by measuring the width of the pulp cavity in panoramic radiographs. The aim of this study was to evaluate the application of the Paewinsky method to digital periapical radiographs. This study was conducted on 103 cases that reported to the Section of Human Identification of the National Forensic Service. The age was calculated by applying the Paewinsky method that measures the root and pulp canal width at three points in a tooth. The estimation results were compared with those calculated by the Johanson method. When the Paewinsky models were applied to digital periapical radiographs, the errors were significantly greater as compared to the original study. The errors of the maxillary second premolar and mandibular lateral incisor were greater than those of the maxillary central incisor, lateral incisor, mandibular canine, and first premolar. Furthermore, errors of the age estimation models in level C were greater than those in levels A and B. This study could be a reference for the application of the Paewinsky method to digital periapical radiographs.

Comparative study of serological detection methods on old bloodstain samples (오래된 혈흔 시료에 대한 혈청학적 식별법의 비교 연구)

  • Lee, Minji;Ahn, Eu-Ree;Kim, Da-Hye;Shin, Heejin;Jung, Ju Yeon;Lee, Sung-Jin;Chun, Byung-Won
    • Analytical Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.201-207
    • /
    • 2018
  • Blood is a commonly found body fluid at crime scenes, and plays an important role in identifying suspects and in the reconstruction of crime scenes. Although serological detection of blood has been widely used in the field of forensic science, research on the detection of old bloodstains is scarce. This work aimed to compare various methods for the detection of old bloodstains and validate the reliability of their results. Four presumptive tests-Tetramethylbenzidine, $Bluestar^{(R)}$, Leucomalachite Green, Kastle-Meyer tests-and two confirmatory tests-Fecal Occult Blood (FOB) and Rapid Stain $Identification^{(TM)}-Blood$ ($RSID^{TM}-Blood$) tests-were compared. Bloodstain samples from post-mortem cases were collected on gauzes and then stored at room temperature for periods from 7 to 30 years. All the presumptive tests were positive, even for the 30-year-old sample. However, FOB and $RSID^{TM}-Blood$ provided false negative results for some samples stored for 17 years or more (1988 to 2001). The results indicate that FOB and $RSID^{TM}-Blood$ are not reliable for the detection of old bloodstains. These findings can be useful in the selection of an appropriate detection method for serological testing of old bloodstains. In addition, the information will be useful background knowledge when applied in the field of forensic practice.

Identification of Food-Poisoning Bacteria (Bacillus cereus) and the Bacterial Toxin Genes for Application to Forensic Microbiology : A Case Report from National Forensic Service (법미생물 검사를 위한 식중독 세균(Bacillus cereus)의 동정 및 독소 유전자 검사법: 국립과학수사연구원 사례보고)

  • Cho, Yoonjung;Lee, Min Ho;Kim, Hyo Sook;Eom, Kiyoon;Kim, Min-Hee;Kim, Jong-Bae;Lee, Dong Sub
    • Journal of Science Criminal Investigation
    • /
    • v.11 no.3
    • /
    • pp.210-217
    • /
    • 2017
  • In the forensic microbiology laboratories, microorganism analyses from food are requested. There have been several cases of Bacillus cereus isolated from the samples requested to the National Forensic Service. B. cereus is an important pathogenic bacterium which can cause food-borne outbreaks. Therefore, we isolated B. cereus from anchovy aekjeot recently requested for microbial examination and identified using MSId based on the 16S rDNA sequence and real-time PCR method. We also conducted PCR for detection of diarrheal toxin genes and an emetic toxin gene and found the presence of nheABC, bceT and entFM diarrheal toxin genes in the B. cereus isolate. There are several clinically important food-poisoning bacteria that should be noted during inspection. In particular, B. cereus can cause food poisoning even when cooked foods are ingested, because B. cereus forms endo-spore which confers strong environmental resistance and heat resistance to the bacteria, and the bacterial emetic toxin also has heat resistance. Here we highlight the importance to distinguish clinically important bacteria such as B. cereus from food specimens, and we expect this study will provide procedures for identification of B. cereus and detection of the bacterial toxin genes for future cases in the forensic microbiology laboratories.

Unexpected Death by Sepsis of Staphylococcus aureus with Infective Endocarditis and Paravertebral Abscess in a Fisherman during Sailing out for Fish: An Autopsy Case (심내막염과 척추 주위 농양을 동반한 황색포도알균에 의한 출어 중의 선상 패혈증 사망: 증례 보고)

  • Kim, Youn Shin;Hwang, In Kwan;Moon, Seohyun;Park, Ji Hye;Lee, Young Seok
    • The Korean Journal of Legal Medicine
    • /
    • v.42 no.4
    • /
    • pp.153-158
    • /
    • 2018
  • Staphylococcus aureus is an important cause of human infections, and it is also a commensal that colonizes the nose, axillae, vagina, throat, or skin surfaces. S. aureus has increasingly been recognized as a cause of severe invasive illness, and individuals colonized with this pathogen are subsequently at increased risk of its infections. S. aureus infection is a major cause of skin, soft tissue, respiratory, bone, joint, and endovascular disorders, and staphylococcal bacteremia may cause abscess, endocarditis, pneumonia, metastatic infection, foreign body infection, or sepsis. The authors describe a case of a fisherman who died of sepsis on a fishing boat during sailing out for fish. The autopsy shows paravertebral abscess, pus in the pericardial sac, infective endocarditis with vegetation on the aortic valve cusp, myocarditis, pneumonia and nephritis with bacterial colonization, and also liver cirrhosis and multiple gastric ulcerations.

Simulation of Indoor Shooting Range Fire in Busan by Using FDS (FDS를 이용한 부산 실내사격장 화재 시뮬레이션)

  • Cho, Young-Jin;Seo, Young-Il;Moon, Byung-Sun;Kim, Sung-Jin;Jeon, Woo-Jeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.143-146
    • /
    • 2011
  • 2009년 11월 14일 발생한 부산 실내사격장 화재와 관련하여 조사내용을 토대로 화재 시뮬레이션용 전선유체역학 모델인 FDS를 이용하여 재현하였으며, 시뮬레이션 결과와 화재당시 녹화된 CCTV 영상을 비교하였다. 2층 발사실에서 시작된 화재는 급격히 연소가 진행되어 약 3초 후에 휴게실로 확산되며, 약 7초 후에는 계단 및 1층 홀을 지나 사람들이 통행하는 인도에까지 연기가 분출되는 것으로 나타났다. 시뮬레이션 결과는 2층 발사실과 휴게실에 녹화된 CCTV 영상 및 1층 홀 옆의 귀금속가게에 녹화된 CCTV 영상과 거의 일치하였다.

  • PDF

Application and evaluation of machine-learning model for fire accelerant classification from GC-MS data of fire residue

  • Park, Chihyun;Park, Wooyong;Jeon, Sookyung;Lee, Sumin;Lee, Joon-Bae
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.231-239
    • /
    • 2021
  • Detection of fire accelerants from fire residues is critical to determine whether the case was arson or accidental fire. However, to develop a standardized model for determining the presence or absence of fire accelerants was not easy because of high temperature which cause disappearance or combustion of components of fire accelerants. In this study, logistic regression, random forest, and support vector machine models were trained and evaluated from a total of 728 GC-MS analysis data obtained from actual fire residues. Mean classification accuracies of the three models were 63 %, 81 %, and 84 %, respectively, and in particular, mean AU-PR values of the three models were evaluated as 0.68, 0.86, and 0.86, respectively, showing fine performances of random forest and support vector machine models.

Combustion of a Female Body Due to an External Ignition Source (외부 점화원에 의한 여성 신체의 연소)

  • Cho, Young Jin;Ji, Hong Keun;Kim, Sun Jae;Lim, Kyu Young;Lee, Dong Kyu;Choi, Gyeong Won;Park, Jong Taek;Moon, Byung Sun;Goh, Jae Mo;Park, Nam Kyu
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.94-96
    • /
    • 2020
  • In November 2013, a case of sustained combustion of a female body was encountered in a Korean farming village. The body was almost completely incinerated from the neck to the knees, and other parts of the body, such as the head, arms, lower legs, and feet, were slightly damaged. The most likely external ignition source was the flame from a matchstick. The elderly woman was found incinerated on the floor of the living room, while other objects in the house were largely undamaged except for having a brown oily or greasy coating. Flammable substances were not detected from the woman's intact pieces of clothing and socks, and her muscular tissues did not contain toxic chemicals. The concentration of carboxyhemoglobin in her peripheral blood was 11% and that of ethyl alcohol in her aqueous humor was below 0.010%. An autopsy failed to determine the exact cause of death because of excessive charring.

Development of Rapid and Simple Drug Identification and Semi Quantitative Analytical Program by Gas Chromatography-Mass Spectrometry (가스크로마토그래피/질량분석기를 이용한 약물의 확인 및 간이 정량분석 프로그램 개발)

  • Kim, Eun-Mi;Han, Eun-Young;Hong, Hyo-Jeong;Jeong, Su-Jin;Choe, Sang-Gil;Rhee, Jong-Sook;Jung, Jin-Mi;Yeom, Hye-Sun;Lee, Han-Sun;Lee, Sang-Ki
    • YAKHAK HOEJI
    • /
    • v.55 no.2
    • /
    • pp.106-115
    • /
    • 2011
  • Systematic toxicological analysis (STA) means the process for general unknown screening of drugs and toxic compounds in biological fluids. In order to establish STA, in previous study we investigated pattern of drugs & poisons in autopsy cases during 2007~2009 in Korea, and finally selected 62 drugs as target drugs for STA. In this study, rapid and simple drug identification and quantitative analytical program by gas chromatography-mass spectrometry(GC-MS) was developed. The in-house program, "DrugMan", consisted of modified chemstation data analysis menu and newly developed macro modules. Total 55 drugs among 62 target drugs were applied to this program, they were 14 antidepressants, 8 anti-histamines, 5 sedatives/hypnotics, 5 narcotic analgesics, 3 antipsychotic drugs, and etc. For calibration curves, fifty five drugs were divided into four groups of range considering their therapeutic or toxic concentrations in blood specimen, i.e. 0.05~1 mg/l, 0.1~1 mg/l, 0.1~5 mg/l or 0.5~10 mg/l. Standards spiked bloods were extracted by solid-phase extraction (SPE) with trimipramine-D3 as internal standard. Parameters such as retention times, 3 mass fragment ions, and calibration curves for each drug were registered to DrugMan. A series of identification, semi quantitation of target drugs and reporting the results were performed automatically. Calibration curves for most drugs were linear with correlation coefficients exceeding 0.98. Sensitivity rate of DrugMan was 0.90 (90%) for 55 drugs at the level of 0.5 mg/l. For standard spiked bloods at the level of 0.5 mg/l for 29 drugs, semi quantitative concentrations were ranged 0.36~0.64 mg/l by DrugMan. If more drugs are registered to database in DrugMan in further study, it will be useful tools for STA in forensic toxicology.

Sensitivity study of the Yfiler® PLUS PCR Amplification Kit in forensic casework samples (법과학 현장시료에서 Yfiler® PLUS PCR Amplification Kit의 민감도 연구)

  • Jung, Ju Yeon;Kim, Kyoung Sook;Park, Sun Wha;Lim, Si Keun;Lee, Dong Sub;Lee, Yang Han
    • Analytical Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.43-48
    • /
    • 2016
  • A variety of Y-STR analysis kits have been developed and used in the forensic field. Prior to the forensic application of a new kit, laboratory validation and sensitivity tests are essential processes in selecting suitable alternatives and for assuring that standard operating procedures are followed. In this paper, we have performed a sensitivity study of a new commercial kit, the Yfiler® PLUS PCR Amplification Kit (Yfiler plus kit, released in 2014) by comparing it with the AmpF/STR® YfilerTM PCR Amplification Kit (Yfiler kit, released in 2004). The Yfiler plus kit includes the 17 Y-STR loci of the Yfiler kit and has been supplemented with 10 new Y-STR loci. First, we analyzed the sensitivity difference between the two kits using commercial control DNA 2800M and 007. In addition, we compared the detection rate between the two kits from the 16 selected forensic casework samples of less than 0.5 ng concentrations. The results show that the sensitivity and detection rate of the Yfiler plus kit are higher than the corresponding rates of the Yfiler kit. In addition, we were able to obtain more Y-STR profiles with the use of the new kit. Thus, we suggest that Yfiler plus kit is a more effective forensic tool to detect Y-STR profiles from forensic casework samples of low concentrations.

An Experimental Study on Melting Characteristics of Low-voltage Miniature Cartridge Fuse (저압용 소형 관형퓨즈의 용단 특성에 관한 실험적 연구)

  • Ji, H.K.;Kim, J.P.;Song, J.Y.;Choi, Y.W.;Park, C.S.;Park, N.K.;Kil, G.S.
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.5
    • /
    • pp.15-20
    • /
    • 2013
  • This paper dealt with melting characteristics of low-voltage miniature cartridge fuse used for 220 V electronic equipment. The experimental sample is low-voltage miniature cartridge fuse with rating of 250 V(3A) and size of $5{\times}20$ mm. In order to evaluate melting and scattering characteristics of the fuse, we applied to 8/20 ${\mu}s$ surge current, overload current and external thermal stress such as flame of fire. From the experimental results, the fuse element was melted and scattered by applied surge current(above 0.79 kA) and overload current(above 4.5 A). It was also attached to the inner surface of the fuse tube. The fuse element was attached as a thin film on inner surface of fuse tube when large surge current was applied. It was confirmed, however, the fuse element was not changed by external thermal stress such as flame and hot-air.