• 제목/요약/키워드: National Fire Safety Codes

검색결과 16건 처리시간 0.026초

성능에 기반을 둔 목조건축물 화재안전기준 개선방안 (Improvement of Performance based wooden building National Fire Safety Codes)

  • 오택흠;박찬석
    • 대한안전경영과학회지
    • /
    • 제18권2호
    • /
    • pp.83-92
    • /
    • 2016
  • Because National Fire Safety Codes is mixed performance criteria and specification, and it defines the fire extinguish equipment type and standards that need to be installed in a building as one method. Therefore, to fully reflect the fire risk characteristics of the building, such as the wooden building there is a limit. In this study, suggested to the performance criteria drawn methodologies through fire load of wooden buildings studies, theory on performance and performance analysis to fire extinguish equipment of the wooden buildings is installed according to current fire safety codes.

초고층 건축물 소방안전관리의 기본방향에 관한 연구 (A Study on the general direction of Fire-Fighting Safety management in high-rise buildings)

  • 최만철;김병석
    • 대한안전경영과학회지
    • /
    • 제13권2호
    • /
    • pp.67-75
    • /
    • 2011
  • Contrast a general building high rise buildings itself has a kind of risk. In this study, the risk of a number of high rise buildings have fire fighting safety management of the particular risks associated with looking for ways to minimize focused. Issues include self fire protection. disaster management, building code and fire code of the mismatch, such as fire protection facilities aspects are explained in terms of three kinds, and for it to take steps in the direction suggested an alternative for high rise buildings. Although differences of opinion between departments will not be easy to fire fighting and building codes regarding conflicts of codes above all require immediate resolution, and high rise buildings to create a standard for effective risk management manual countermeasures will also be ensured.

LATEST INTERNATIONAL DEVELOPMENTS IN PASSIVE FIRE PROTECTION

  • Marx, Olliver
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.227-243
    • /
    • 1997
  • Fire and smoke can from a small ignition source develop rapidly. Active systems in combination with Passive Fire Protection measures will offer highest safety standards to the building's developers and occupants. Nevertheless, the fire growth is very unpredictable and it is therefore essential at the planning stage that tested solutions are well selected according to National codes and later on installed by qualified contractors to ensure optimum performance. This demonstrates that Passive Fire Protection as safety measure cannot be neglected. Recent fire cases all over the world still proof that fire can develop any time and any where even in countries of high safety standards.

  • PDF

FIRE WATER SYSTEM RELIABILITY IN INDUSTRIAL APPLICATIONS

  • James M. Dewey;Kim, Yong-Dal
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.526-533
    • /
    • 1997
  • Reliability of fire protection systems is often discussed, written about, and even put into codes and standards. However, reliability is seldom considered for the fire protection system as a whole. Why does this happen and why should the designer consider the system as a whole\ulcorner Existing codes and standards incorporate the concept of reliability usually In the form of key component redundancy for some parts of a system. The "Fire Safety Concepts Tree" presented in the National Fire Protection Association Guide 550, Guide to the Fire Safety Concepts Tree, provides a starting point for considering the performance of a water based fire suppression system. Considering fire protection objectives for water based fire suppression systems, means of evaluating system reliability can be developed. This development requires identification of system components that are significant to the overall system reliability.

  • PDF

스프링클러설비 화재안전기준 개정에 대한 고찰 (A Study on the Revision of the National Fire Safety Codes of Sprinkler System)

  • 정기신
    • 한국화재소방학회논문지
    • /
    • 제27권5호
    • /
    • pp.32-37
    • /
    • 2013
  • 스프링클러설비의 화재안전기준 중 불합리한 것에 대하여 개정할 것을 제안을 하였다. 배관의 용어 중 "수평주행배관"의 용어정의를 추가하도록 하였으며 "격자형배관방식"에 대한 정의를 수정하도록 제안하였다. 스프링클러헤드의 소화수 방출압력을 규정한 조항을 합리적으로 운영하기 위하여 NFPA 13의 스케줄방식의 최소 유량과 압력기준을 확인하였고 이와 유사한 최소 요구량 기준을 제정할 것을 제안하였다. 압력수조의 평상 시 유지 압력 산출식을 바르게 개정할 것을 제시하였으며 압력단위의 변화에 의한 올바른 K값의 사용을 제시하였고 기존의 K값 등을 사용하기 위하여 압력단위를 [bar]를 사용할 것을 제안하였다.

방화문의 누설틈새 계산 및 연돌효과 분석 (The Leakage Crack Calculation of the Fire Door and the Stack Effect Analysis)

  • 김일영;권창희
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.46-53
    • /
    • 2013
  • 건축의 환경이 변하면 그에 따른 설계기준도 변하여야 한다. 방화문의 시험기준이 2005년 7월 27일 차연성 시험이 적용되면서 문틈이 기밀한 구조로 바뀌었다. 그러나 국가화재안전기준은 영국의 자료를 인용한 과거의 문틈규정을 적용함으로서 현실과 설계 규정의 차이가 오차나 안전율 이상으로 과도하다. 설계와 현실의 차이로 인하여 발생하는 결과 및 현상을 분석하고 개정되어야 할 국가화재안전기준의 누설틈새면적 계산법을 제시하고 연돌효과로 인한 방연풍속의 차이를 분석하였으며 생활패턴 및 피난패턴을 반영한 공동주택의 방연풍속 측정법에 대해 고찰하고 합리적인 측정법을 제시하였다.

Evacuation Safety Evaluation of Tourist Hotels with the Fire Alarm Method

  • Moon, Sung-Chun;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.363-375
    • /
    • 2021
  • The purpose of this study is to analyze the safety of evacuation using the Pathfinder program for the alert at once, the priority alarm method, the priority alarm method for the four floors above, and the sequential priority alarm method, which is a modification of the priority alarm method specified in the tourist hotel building. Currently, in Korea's National Fire Safety Codes (NFSC), fire alarm methods are compulsorily applied differently depending on the number of floors and total floor area of a building. Although the growth rate is getting faster due to the diversification of building structures, it is still an obstacle to improving evacuation safety to comply with the standardized fire alarm method in NFSC. As a result of the experiment, the evacuation time was found to be faster with the priority alarm method for the four floors above than the priority alarm method applied to the specific firefighting object. Compared to the priority alarm method applied to the tourist hotel, which is a specific firefighting target with 5 or more floors and a total floor area of more than 3,000m2, the time was shortened by 3.7 seconds when measured by applying the priority alarm method for the four floors directly above. This indicates that it is necessary to take measures to select a fire alarm method suitable for the structure and environmental conditions of the building rather than applying the uniform NFSC regulations.

The Chinese Performance-based Code for Fire-resistance of Steel Structures

  • Li, Guo-Qiang;Zhang, Chao
    • 국제초고층학회논문집
    • /
    • 제2권2호
    • /
    • pp.123-130
    • /
    • 2013
  • In the past two decades, researchers from different countries have conducted series of experimental and theoretical studies to investigate the behaviour of structures in fire. Many new insights, data and calculation methods have been reported, which form the basis for modern interdisciplinary structural fire engineering. Some of those methods are now adopted in quantitative performance-based codes and have been migrated into practice. Mainly based on the achievements in structural fire research at China, the Chinese national code for fire safety of steel structures in buildings has been drafted and approved, and will be released in this year. The code is developed to prevent steel structures subjected to fire from collapsing, ensure safe evacuation of building occupants, and reduce the cost for repairing the damages of the structure caused by fire. This paper presents the main contents of the code, which includes the fire duration requirements of structural components, fundamental requirements on fire safety design of steel components, temperature increasing of atmosphere and structural components in fire, loading effect and capacity of various components in fire, and procedure for fire-resistant check and design of steel components. The analytical approaches employed in the code and their validation works are also presented.

열해석을 이용한 가스 실린더 캐비닛의 내화성능 최적설계 (Optimum Design on Fire Resistance of Gas Cylinder Cabinets using Thermal Analysis)

  • 남민서;김지유;김의수
    • 한국가스학회지
    • /
    • 제26권1호
    • /
    • pp.34-40
    • /
    • 2022
  • 특정 고압가스 등을 사용하기 위해 배관과 안전장치 등이 일체로 구성된 가스 실린더 캐비닛은 화재 발생 시 고온의 열로 인한 급격한 압력상승으로 실린더 폭발 및 파편 비산 등의 위험성을 가지고 있다. 이러한 위험성은 용기 내부에 충전된 가스의 유출을 초래하여 중독, 질식 등의 2차 피해를 발생시킬 가능성이 크므로 내부 용기로 인한 피해를 줄이기 위해서는 가스 실린더 캐비닛의 내화성능 확보가 매우 중요하다. 국외의 경우 가스 실린더 캐비닛이 화염에 노출되는 상황에서 일정 시간동안 내부의 실린더를 보호할 수 있도록 미국 NFPA code, 유럽 EN-14470-2 등에서 가스 실린더 캐비닛 내화시험 기준을 규정하고 있다. 하지만 국내의 경우 내압성능과 기밀성능 기준만 명시되어 있고, 그 대상은 배관계로 한정되어 있으며 국외보다 가스 실린더 캐비닛의 내화성능을 위한 연구 및 규정이 미흡한 실정이다. 이에 본 연구에서는 국내 가스 실린더 캐비닛의 내화성능 기준 확립을 위해 유한요소해석 프로그램인 ANSYS를 이용하여 열해석을 수행함으로써 화재 발생 시 구조, 재질 측면에서의 최적 조건을 도출하고자 한다.

CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구 (Smoke Control Performance of a Serial Structure Using "CONTAM")

  • 김미선;서동길;구선환;유영민;송영주
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.53-62
    • /
    • 2019
  • 최근 건축물은 대지 이용의 효율성을 높이기 위해 주상 복합화·고층화되는 추세이며, 이에 따른 화재의 발생빈도 및 잠재적인 위험요소도 증가하고 있다. 특히, 고층 공동주택의 경우 비상용승강기와 별도로 승용승강기 중 1대 이상을 피난용승강기로 설치하게 되어 특별피난계단 부속실, 비상용승강기 승강장 겸용의 경우 피난용승강기 승강장과 직렬형태의 구조가 되어 새로운 형태의 제연구역 이 발생한다. 따라서 비상용승강기 승강장과 피난용승강기 승강장의 직렬형태 구조에 대한 제연구역 선정의 제시가 필요하며, 새로운 형태에서 제연성능을 달성하는 것에 대한 문제가 대두되고 있다. 따라서 본 논문에서는 이러한 문제를 해결하기 위해 CONTAM을 이용하여 각 제연구역 형식(비상용승강기 승강장 단독제연, 피난용승강기 승강장 단독제연, 비상용승강기 승강장과 피난용승강기 승강장 동시제연 누설틈새 적용·미적용)의 방연풍속, 차압을 확인하고, 직렬형태 구조에 대해 제연성능을 확보하기 위한 방안을 제시하고자 한다.