• Title/Summary/Keyword: National Control Point

Search Result 1,794, Processing Time 0.031 seconds

Improvement of the Cadastral Control Points for an Establishment of the National Cadastral Reform Infrastructures (지적재조사 시행기반 조성을 위한 지적측량기준점체계 정비방안)

  • Kim, Soon-Tae
    • Journal of the Korean association of regional geographers
    • /
    • v.15 no.1
    • /
    • pp.161-178
    • /
    • 2009
  • The introduction of a world geodetic system for cadastral survey will be started the enactment of the law on survey, hydro-graphical examination and cadastre. However, the cadastral control points are not homogeneous and correspond with national control points because of various reasons. To cope with this problem, the 1,600 high accurate control points, which can be interlocked with national GPS control points, has selected from existing 20,000 cadastral control points. These selected control points were calculated as an accurate world geodetic system and it makes a homogeneous cadastral survey network. Through these measures, for the future carrying out national project, this study will be effectively contributed to establish the cadastral infrastructures for the Korea cadastral reform project.

  • PDF

Maximum Power Point Tracking Technique of PV System for the Tracking of Open Voltage according to Solar Module of Temperature Influence (태양광 모듈 온도 영향에 따른 개방전압 추종을 위한 PV 시스템의 최대 전력 점 기법)

  • Seo, Jung-Min;Lee, Woo-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.38-45
    • /
    • 2021
  • The photovoltaic module has the characteristic of changing its output characteristics depending on the amount of radiation and temperature, where the arrays that connect them in series and parallel also have the same characteristics. These characteristics require the MPPT technique to find the maximum power point. Existing P&O and IncCond cannot find the global maximum power point (GMPP) for partial shading. Moreover, in the case of Improved-GMPPT and Enhanced Search-Skip-Judge-GMPPT, GMPP due to partial shading can be found, but the variation in the open voltage during temperature fluctuations will affect the operation of the Skip and will not be able to perform accurate MPPT operation. In this study, we analyzed the correlation between voltage, current, and power under solar module and array conditions. We also proposed a technique to find the maximum power point even for temperature fluctuations using not only the amount of radiation but also the temperature coefficient. The proposed control technique was verified through simulations and experiments by constructing a 2.5 kW single-phase solar power generation system.

Urban Stormwater Capture Curve using 3-Parameter Mixed Exponential Probability Density Function (3변수 혼합 지수 확률밀도함수를 이용한 도시 강우 유출수 포착곡선의 작성)

  • Han, Suhee;Park, Moo Jong;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.4
    • /
    • pp.430-435
    • /
    • 2008
  • In order to design Non-point source management, the aspect of statistical features of the entire precipitation data should be focused since non-point source discharge is driven by continuous rainfall runoffs. 3-parameter mixed exponential probability density function is used to establish urban stormwater capture curve instead of previous single-parameter exponential PDF. Then, recent 10-year data in Busan are applied to establish the curve. The result shows that 3-parameter mixed PDF gives better resolution.

Development of Heliostat Aiming Point Allocation Scheme in Heliostat Field Control Algorithm for 200kW Tower Type Solar Thermal Power Plant (200kW 탑형 태양열발전시스템을 위한 헬리오스타트 필드 운영 알고리즘의 헬리오스타트 반사목표점 할당 방안 개발)

  • Park, Young Chil
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.21-29
    • /
    • 2014
  • Heliostat field control algorithm is the logics to operate the heliostat field of tower type solar thermal power plant and it could include various methodologies of how to control the heliostat field so as to optimize the energy collection efficiency as well as to reduce the system operating cost. This work, as the first part of the consecutive works, presents heliostat aiming mint allocation scheme which will be used in the heliostat field control algorithm for 200kW solar thermal power plant built in Daegu, Korea. We first discuss the structure of heliostat field control system required for the implementation of aiming scheme developed in this work. Then the methodologies to allocate the heliostat aiming points on the receiver are discussed. The simulated results show that the heliostat aiming point allocation scheme proposed in this work reduces the magnitude of peak heat flux on the receiver more than 40% from the case of which all the heliostats in the field aim at the center of receiver simultaneously. Also it shows that, when the proposed scheme is used, the degradation of heliostat field optical efficiency is relatively small from the maximal optical efficiency the heliostat field could have.

The Distribution of Mismatches in Government Policy Response against COVID-19 in Terms of Risk Communication and its Implications

  • BAE, Suk-Kyeong;CHOI, Choongik
    • Journal of Distribution Science
    • /
    • v.19 no.12
    • /
    • pp.91-101
    • /
    • 2021
  • Purpose: This study aims to explore the effects of government's value intervention messages on the prevention and control of infectious disease in the risk communication process in terms of goveremnt policy response to COVID-19 from the mismatch message perspective, and draws the relevant implicaitons. Due to the infeciton spread, some people point out that depression caused by COVID-19 is because of wrong signals of the government and infectious disease prevention and control authorities, namely value intervention messsages. Research design, data and methodology: This study examined the epidcmic situation through message deails regarding the effects of government's mismatch messages on prevention and control of infectious disease and the resulting phenomena. Results: People's lives are under serious threat overall, so the declaration of the end of COVID-19 is almost impossible unlike MERS. Economic downturn due to foreced prevention and control regulaitons of COVID-19, mistruct of social distancing, fatigue on mismatch messages, and moral hazard on the awareness of prevention and control of infectious disease are negative phenomena to risk communiaiton on COVID-19. Conclusions: This study investigated the government authorities' policy sending wrong signals due to mismatching of the reality at this point in time for infectious disease prevention and control from the risk communicaiton perspectrive.

ON OPTIMAL CONTROL OF A BOUNDARY VALUE PROBLEM

  • Kim, Hongchul;Rim, Gye-Soo
    • Korean Journal of Mathematics
    • /
    • v.6 no.1
    • /
    • pp.27-46
    • /
    • 1998
  • We are concerned with an optimal control problem governed by a Poisson equation in which body force acts like a control parameter. The cost functional to be optimized is taken to represent the error from the desired observation and the cost due to the control. We recast the problem into the mixed formulation to take advantage of the minimax principle for the duality method. The existence of a saddle point for the Lagrangian shall be shown and the optimality system will be derived therein. Finally, to attain an optimal control, we combine the optimality system with an operational technique. By achieving the gradient of the cost functional, a convergent algorithm based on the projected gradient method is established.

  • PDF

The MPPT Control oh Photovoltaic System using FVSS-PO Method (FVSS-PO를 이용한 태양광 발전시스템의 MPPT 제어)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.20-26
    • /
    • 2013
  • This paper proposes the maximum power point tracking(MPPT) control of photovoltaic system using fuzzy based variable step size perturbation & observation(FVSS-PO) method. Conventional PO and incremental conductance(IC)MPPT control algorithm generally uses fixed step size. A small fixed step size will cause the tracking speed to decrease and tracking accuracy of the MPP will decrease due to large fixed step size. Therefore, the fixed step size can't be satisfying both the tracking speed and the tracking accuracy. This paper proposes FVSS-PO MPPT algorithm that adjusts automatically step size of PO by fuzzy control according to operating conditions. The validity of MPPT algorithm proposed in this paper prove through compare with conventional PO MPPT algorithm.

An adaptive predictive control of distillation process using bilinear model (쌍일차 모델을 이용한 증류공정의 적응예측제어)

  • Lo, Kyun;Yeo, Yeong-Koo;Song, Hyung-Keun;Yoon, En-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.99-104
    • /
    • 1991
  • An adaptive predictive control method for SISO and MIMO plants is proposed. In this method, future predictions of process output based on a bilinear CARIMA model are used to calculate the control input. Also, a classical recursive adaptation algorithm, equation error method, is used to decrease the uncertainty of the process model. As a result of the application on distillation process, the ability of the set-point tracking and the disturbance rejection is acceptable to apply to the industrial distillation processes.

  • PDF

ACOUSTIC EMISSION CHARACTERISTIC OF THE RAT FEMUR AFTER ADMINISTRATION OF SODIUM FLUORIDE (불소섭취에 따른 백서 대퇴골의 파절특성에 관한 Acoustic Emission 연구)

  • Song, Keun-Bae;Lee, Young-Eun;Kim, Hye-Young;Lee, Sang-Han
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.1
    • /
    • pp.16-23
    • /
    • 2002
  • To understand the micro-mechanical changes and the effects of the fluoride on rat's femur after administration of sodium fluoride, the three-point bending test, acoustic emission analysis during the three-point bending test and scanning electron microscopy were performed. The obtained results were as follows: 1. Bone strength increased in the rats given 1, 5, 10 and 20 ppm of fluoride but, there were no statistical significances (p>0.05). 2. With increasing the concentration of fluoride, most AE events released rapidly just before the maximum load and smaller events were recorded than the control group's. The average of cumulative AE event counts until maximum load of the femur in 20 ppm group were significantly small with respect to the control group's (p<0.05). 3. Fracture surfaces were well coincide with the results of acoustic emission behavior. Analyses of fracture surfaces indicated that, consistent with its the highest load, rat femur in 20 ppm fluoride group displays the roughest surface.

Application Evaluation of Best Management Practices for Agricultural Non-Point Source Pollution using Delphi Survey Method (전문가 델파이 방법을 이용한 농업 비점오염 저감 기술의 현장 적용성 조사)

  • Kim, Min-Kyeong;Jung, Goo-Bok;Kim, Min-Young;Kim, Myung-Hyun;Cho, Kwang-Jin;Choi, Soon-Kun;Hong, Seong-Chang;So, Kyu-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.2
    • /
    • pp.144-147
    • /
    • 2014
  • BACKGROUND: It is essential to prioritize the exact and clear understanding of agricultural nonpoint source pollution (NPS) controls. The realistic policies and systems should also be developed based on this understanding. Therefore, this study aimed to present agricultural Best Management Practices (BMPs) applicable for the fields based on the Delphi survey result. METHODS AND RESULTS: This study deduced the evaluation items to assess each BMP for agricultural NPS control and conducted the surveying using the Delphi method based on agricultural BMP experts. In addition, its on-the-spot application were evaluated. Considering its importance, technical, social and economic proprieties showed that political support was ranked first and followed by cost investment, labor investment, reduction effect and resident participation. The survey findings by agricultural BMP experts showed the good performance of on-the-spot application can be achieved from fertilization by soil testing, residue and green manure application and contour plowing which are applicable within a field. Agricultural BMPs, highly applicable for the fields, were the countermeasures that farmers who are the principal bodies of agricultural NPS control could be participated directly. CONCLUSION: The active participation of farmers is essential for effective control of agricultural NPS. It is necessary to establish various incentive systems.