• 제목/요약/키워드: Narrow pulse

검색결과 109건 처리시간 0.017초

세폭소거 펄스 방식을 적용한 AC PDP에서의 동특성 전압 마진 (Dynamic Voltage Margin of AC PDP with the Narrow Erase Pulse Method)

  • 안양기;윤동한
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권11호
    • /
    • pp.541-545
    • /
    • 2002
  • This paper proposes the new narrow erase method to erase wall charges formed in an AC plasma display panel (PDP) cell. In the proposed method, pulse timing of switch at the sustain period is adjusted for inducing, a weak discharge. Then, after the narrow erase, the voltage of the X electrode is set to differ from that of the Y electrode. For the proposed method, the measured maximum address voltage margin was 38.3V at Y_Rest voltage of 100V and sustain voltage of 180${\sim}$185V. However, for the conventional method, in which the X and Y electrodes are set to be of equal voltage after the narrow erase, the measured maximum address voltage margin was 31.3V at Y_Rest voltage of 150V and sustain voltage of 180V. This result shows that the measured maximum voltage margin for the proposed method is about 7V(22%) higher than that for the conventional method.

헤테로다인 방법을 이용한 펄스 증폭된 레이저빔의 주파수 Chirping연구 (Study of frequency chirping of pulse amplified laser beam by using heterodyne method)

  • 김진태
    • 한국광학회지
    • /
    • 제13권1호
    • /
    • pp.70-72
    • /
    • 2002
  • 좁은 선폭을 갖는 연속 레이저 빔이 제이조화된 Nd:YAG레이저빔과 Bethune셀을 사용하여 좁은 선폭을 갖는 펄스 레이저빔이 생성되었다. 증폭된 펄스빔의 주파수 chirping정도는 헤테로다인 방법을 이용하여 측정되었으며, 헤테로다인 맥놀이신호로부터 순간적인 위상 변화량을 추출함으로서 분석되었다. 10 ns 펄스에 의해 MHz 이하의 선폭을 가지는 연속 레이저빔으로부터 증폭된 주파수 chirping은 80MHz정도로 매우 좁은 선폭의 증폭된 펄스 레이저빔이 얻어졌다.

Improved Space Vector Modulation Strategy for AC-DC Matrix Converters

  • Liu, Xiao;Zhang, Qingfan;Hou, Dianli;Wang, Siyao
    • Journal of Power Electronics
    • /
    • 제13권4호
    • /
    • pp.647-655
    • /
    • 2013
  • In this paper, an approach to reduce the common-mode voltage and to eliminate narrow pulse for implemented AC-DC matrix converters is presented. An improved space vector modulation (SVM) strategy is developed by replacing the zero space vectors with suitable pairs of active ones. Further, while considering the commutation time, the probability of narrow pulse in the conventional and proposed SVM methods are derived and compared. The advantages of the proposed scheme include: a 50% reduction in the peak value of the common-mode voltage; improved input and output performances; a reduction in the switching loss by a reduced number of switching commutations and a simplified implementation via software. Experimental results are presented to demonstrate the correctness of the theoretical analysis, as well as the feasibility of the proposed strategy.

Designing Optimal Pulse-Shapers for Ultra-Wideband Radios

  • Luo, Xiliang;Yang , Liuqing;Giannakis, Georgios-B.
    • Journal of Communications and Networks
    • /
    • 제5권4호
    • /
    • pp.344-353
    • /
    • 2003
  • Ultra-wideband (UWB) technology is gaining increasing interest for its potential application to short-range indoor wireless communications. Utilizing ultra-short pulses, UWB baseband transmissions enable rich multipath diversity, and can be demodulated with low complexity receivers. Compliance with the FCC spectral mask, and interference avoidance to, and from, co-existing narrow-band services, calls for judicious design of UWB pulse shapers. This paper introduces pulse shaper designs for UWB radios, which optimally utilize the bandwidth and power allowed by the FCC spectral mask. The resulting baseband UWB systems can be either single-band, or, multi-band. More important, the novel pulse shapers can support dynamic avoidance of narrow-band interference, as well as efficient implementation of fast frequency hopping, without invoking analog carriers.

Suppression of IEEE 802.11a Interference in TH-UWB Systems Using Singular Value Decomposition in Wireless Multipath Channels

  • Xu, Shaoyi;Kwak, Kyung-Sup
    • Journal of Communications and Networks
    • /
    • 제10권1호
    • /
    • pp.63-70
    • /
    • 2008
  • Narrow-band interference (NBI) from the coexisting narrow-band services affects the performance of ultra wideband (UWB) systems considerably due to the high power of these narrow-band signals with respect to the UWB signals. Specifically, IEEE 802.11a systems which operate around 5 GHz and overlap the band of UWB signals may interfere with UWB systems significantly. In this paper, we suggest a novel NBI suppression technique based on singular value decomposition (SVD) algorithm in time hopping UWB (TH-UWB) systems. SVD is used to approximate the interference which then is subtracted from the received signals. The algorithm precision and closed-form bit error rate (BER) expression are derived in the wireless multipath channel. Comparing with the conventional suppression methods such as a notch filter and a RAKE receiver, the proposed method is simple and robust and especially suitable for UWB systems.

'맥상(脈狀)의 환측(患側)' 취혈(取穴)과 침(鍼) 치료(治療) 경과 확인 기준으로서의 촌구맥진(寸口脈診)의 의의(意義) (Significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'The affected part of the pulse wave')

  • 심소현;강민정;김재규;백진웅
    • 대한한의학원전학회지
    • /
    • 제27권1호
    • /
    • pp.47-56
    • /
    • 2014
  • Objective : The aim of this study is to find out the significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' based on the literature. Method : (1) The clear concepts of the 'unaffected part' and the 'affected part' were organized. (2) The relation between the pulse diagnosis and the acupuncture in Hwangjenaekyung was studied. (3) The indications of Mu acupuncture treatment(繆刺法) and Geo acupuncture treatment(巨刺法) in Hwangjenaekyung was studied. (4) The types and changes of pulse diagnosis in Hwangjenaekyung was studied, especially based on the relation between Sambuguhu pulse diagnosis(三部九候脈診) and Chongu pulse diagnosis(寸口脈診). (5) By synthesizing these results, the significance of Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' was found. Result & Conclusion : 1. When the affected part and the unaffected part are defined, it is necessary to make clear that which one of next three definitions is used ; Firstly, 'the broad sense of definition of the affected part and the unaffected part of the symptom', which contains the pulse wave. Secondly, 'the narrow sense of definition of the affected part and the unaffected part of the symptom', without the pulse wave. And thirdly, 'the definition of the affected and the unaffected part of the pulse wave', which has the only independent standard of the pulse wave. 2. Geo acupuncture treatment(巨刺法) is an acupuncture treatment which means the needling on 'the affected part of the pulse wave' based on Sambuguhu pulse diagnosis (三部九候脈診), and Mu acupuncture treatment(繆刺法) is an acupuncture treatment which means the needling on 'the unaffected part of the symptom based on the narrow sense of the definition'. The range of the indications of Mu acupuncture treatment(繆刺法) and Geo acupuncture treatment(巨刺法) contains most of the diseases which contains Rakbyung(絡病), Kyungbyung(經病) and Ojangbyung(五臟病). 3. Chongu pulse diagnosis(寸口脈診) contains not only the range of the indications of Sambuguhu pulse diagnosis(三部九候脈診), but also most of the diseases. 4. From synthesizing these results of the study on the literature, we infer that Chongu pulse diagnosis as the standard of measuring the result of the acupuncture on 'the affected part of the pulse wave' is significant.

촬상소자를 이용한 맥동의 2차원 계측 (2-dimensional Measurement of Arterial Pulse by Imaging Devices)

  • 김기왕
    • 대한한의진단학회지
    • /
    • 제12권2호
    • /
    • pp.8-17
    • /
    • 2008
  • Objectives: For the traditional pulse diagnosis in Oriental Medicine, not only the pulse shape in time domain, but the width, length and depth of arterial pulse also should be measured. However, conventional pulse diagnostic systems have failed to measure the spatial parameters of the arterial pulse e.g. effective length of arterial pulse in the wrist. In fact, there are many ways to measure that kind of spatial features in arterial pulsation, but among them, the method using image sensor provides relatively cheap and simple way, therefore I tested feasibility of measuring 2-dimensional pressure distribution by imaging devices. Methods: Using widely used PC cameras and dotted balloons, the subtle oscillation of skin over the radial artery was recorded continuously, and then the displacement of every dot was calculated. Consequently, the time course of that displacements shows arterial pulse wave. Results: By the proposed method I could get pressure distribution map with 30Hz sampling rate, 21steps quantization resolution, and approximately 1mm spatial resolution. With reduced quantization resolution, $3cm{\times}4cm$ view angle could be achieved. Conclusion: Although this method has some limitations, it would be useful method for detecting 2-dimensional features of arterial pulse, and accordingly, this method provides a novel way to detect 'narrow pulse', 'wide pulse', 'long pulse', 'short pulse', and their derivatives.

  • PDF

소아맥진(小兒脈診)의 특성(特性)에 대한 소고(小考) (A study on The Characteristic of Traditional Pediatric Pulse Diagnosis)

  • 백유상
    • 대한한의학원전학회지
    • /
    • 제27권1호
    • /
    • pp.111-122
    • /
    • 2014
  • Objective : The region, observation period, figuration of pulse, pulse frequency, process of diagnosis and related diagnostic methods in traditional pediatric pulse diagnosis were studied in this article. Method : The articles related to traditional pediatric pulse diagnosis in Traditional medical classics, and analysis to the characteristics of it was done, then lastly, the principle of pulse manifestation and the meaning of application to modern times were considered. Result & Conclusion : It is difficult to catch the figuration of pediatric pulse because of dynamic change of body conditions, fast heartbeat and narrow region of pulse. Therefore, the pulse diagnosis appropriated for children have been developed and combined with the special diagnosis methods, for example, palpation of forehead and observation of index finger. The traditional pediatric pulse diagnosis is done with just one finger palpation in the period of 3 to 5 years old to identify the speed, length, size and height of pulse. The standard average of pulse frequency is 7~8 par breath in the period of 3 to 5 years old according to traditional medical classic.

플라즈마 디스플레이 패널의 고속 구동을 위한 세폭 펄스 어드레스 방전특성 (Discharge Characteristics of Narrow Width Pulse Addressing for the High-Speed Driving of Plasma Display Panels)

  • 염정덕
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.13-19
    • /
    • 2007
  • 본 연구는 1,080개의 주사선수를 가지는 full-HD PDP를 위한 새로운 고속구동방식에 관한 것으로 고속 어드레스에 의한 표시방전의 방전특성을 고찰하여 새로운 구동방식의 특성을 평가하였다. 이 구동방식에서 어드레스 펄스의 폭이 좁아지면 최초 표시방전의 상대적 방전강도와 방전지연시간은 그 영향을 받는다. 어드레스 펄스의 인가위치의 변화는 방전강도와 무관하나 방전지연시간에는 영향을 미친다. 그러나 어드레스 펄스의 인가위치가 [$6{\mu}s$]이내이고 펄스의 폭이 [$0.7{\mu}s$]이내라면, 어드레스 펄스의 인가위치나 폭에 무관하게 안정된 표시방전을 유도할 수 있다. 실험결과로부터 폭이 좁은 어드레스 펄스를 사용하는 고속구동기술은 축적되는 벽전하의 부족으로 인해 공간전하의 영향에 매우 민감하다는 것을 알았다.