• Title/Summary/Keyword: Naked-eye

Search Result 409, Processing Time 0.025 seconds

Parametric Imaging with Respiratory Motion Correction for Contrast-Enhanced Ultrasonography (조영증강 초음파 진단에서 호흡에 의한 흔들림을 보정한 파라미터 영상 생성 기법)

  • Kim, Ho-Joon;Cho, Yun-Seok
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.9 no.2
    • /
    • pp.69-76
    • /
    • 2020
  • In this paper, we introduce a method to visualize the contrast diffusion patterns and the dynamic vascular patterns in a contrast-enhanced ultrasound image sequence. We present an imaging technique to visualize parameters such as contrast arrival time, peak intensity time, and contrast decay time in contrast-enhanced ultrasound data. The contrast flow pattern and its velocity are important for characterizing focal liver lesions. We propose a method for representing the contrast diffusion patterns as an image. In the methods, respiratory motion may degrade the accuracy of the parametric images. Therefore, we present a respiratory motion tracking technique that uses dynamic weights and a momentum factor with respect to the respiration cycle. Through the experiment using 72 CEUS data sets, we show that the proposed method makes it possible to overcome the limitation of analysis by the naked eye and improves the reliability of the parametric images by compensating for respiratory motion in contrast-enhanced ultrasonography.

The Features of Asian Dust Events Originated in Manchuria (만주에서 발원한 황사현상 (II) -2001년 이후 사례를 중심으로-)

  • Kim, Sumin;Chun, Youngsin;Kim, Seung-Bum
    • Atmosphere
    • /
    • v.20 no.3
    • /
    • pp.273-286
    • /
    • 2010
  • The northeast part of China(hereafter Manchuria) is one of Asian dust source regions along with Gobi, Inner Mongolia and Loess Plateau. In this study, a geographical survey over the area was carried out to determine its soil characteristics in June 2009. It revealed that some parts of the area, especially near Keerchin desert, consist of alkali clay soil mixed up with sand. Manchuria, where is a vast cornfield, can be a potential source region of Asian dust from fall to following spring after harvesting. The frequency of Asian dust over the region from 1996 to 2009 was examined using 3-hourly GTS SYNOP data and it showed that the occurrence of Asian dust over the region is high in the springtime. It was also revealed that snow cover is the key parameter affecting on the frequency through the analysis of NCEP reanalysis data. To scrutinize the path and structure of Asian dust from Manchuria, the event on 3~4 April 2008 and 25 January 2010 were intensively investigated with regard to features of synoptic weather patterns, satellite imagery, airstream, naked eye-observations, concentrations of PM10, 2.5 and 1.0. For this case, the Asian dust from the area reached to Korea less than a day. However, the duration time of the dust in Korea was short (< 7 hours). The average of hourly PM10 reached up to $340{\mu}g/m^{3}$ at Baengnyeondo during the period. The high PM2.5 and PM1.0 concentrations were also observed at several sites in Korea, indicating that air pollutants could be transported along with the dust.

A Study on Underwater-Pipe Video Image Mosaicking using Digital Photogrammetry (수치사진측량을 이용한 수중 파이프 비디오 모자익 영상 제작에 관한 연구)

  • Kang, Jin-A;Kwon, Kwang-Seok;Kim, Byung-Guk;Oh, Yoon-Seuk
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.4
    • /
    • pp.150-160
    • /
    • 2008
  • The present domestic underwater and ocean facilities management depends on analysis with the naked eye. This study performs quantitative analysis to improve conventional methods, analyze spatial situation of underwater facilities. This research is divided into two steps; underwater image distortion correction and image mosaic step. First, underwater image distortion correction step is for the production of underwater target, calculates the correction parameters, and then developed the method that convert the original image point to whose distortion is corrected. Second step is for the obtaining pipe images installed in the underwater, corrects the distortion, and then transforms a coordinates of the correction pipe image. After coordinate transformation, we make the mosaic image using the singularities. As a result, when we measure the distance between pipe and underwater ground and compare with calculation value on mosaic image, it is showed that RMSE is 0.3cm.

  • PDF

The Evaluation of Image Quality According to the Change of Reconstruction Algorithm of CT Images (재구성 알고리즘 변화에 따른 CT 영상의 화질 평가)

  • Han, Dong-Kyoon;Park, Kun-Jin;Ko, Shin-Kwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • In this study, the correlation among the changes of Modulation Transfer Function(MTF) in the noise and high-contrast resolution and the change of Contrast to noise ratio(CNR) in the low-contrast resolution will be examined to investigate the estimation of image quality according to the type of algorithms. The image data obtained by scanning American Association of Physicists in Medicine(AAPM) phantom was applied to each algorithm and the exposure condition of 120 kVp, 250 mAs, and then the CT number and noise were measured. The MTF curved line of the high-contrast resolution was calculated with Point Spread Function(PSF) by using the analysis program by Philips, resulting in 0.5 MTF, 0.1 MTF and 0.02 MTF respectively. The low-contrast resolution was calculated with CNR and the uniformity was measured to each algorithm. Since the measurement value for the uniformity of the equipment was below ${\pm}$ 5 HU, which is the criterion figure, it was found to belong to the normal range. As the algorithm got closer from soft to edge, the standard deviation of CT number increased, which indicates that the noise increased as well. As for MTF, 0.5 MTF, 0.1 MTF and 0.02 MTF were all sharp algorithms, and as the algorithm got closer from soft to edge, it was possible to distinguish more clearly with the naked eye. On the other hand, CNR gradually decreased, because the difference between the contrast hole CT number and the acrylic CT number was the same while the noise of hole increased.

  • PDF

Algorithm Development of a Visibility Monitoring Technique Using Digital Image Analysis

  • Pokhrel, Rajib;Lee, Hee-Kwan
    • Asian Journal of Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.8-20
    • /
    • 2011
  • Atmospheric visibility is one of the indicators used to evaluate the status of air quality. Based on a conceptual definition of visibility as the maximum distance at which the outline of the selected target can be recognized, an image analysis technique is introduced here and an algorithm is developed for visibility monitoring. Although there are various measurement techniques, ranging from bulk and precise instruments to naked eye observation techniques, each has their own limitations. In this study, a series of image analysis techniques were introduced and examined for in-situ application. An imaging system was built up using a digital camera and was installed on the study sites in Incheon and Seoul separately. Visual range was also monitored by using a dual technology visibility sensor in Incheon and transmissometer in Seoul simultaneously. The Sobel mask filter was applied to detect the edge lines of objects by extracting the high frequency from the digital image. The root mean square (RMS) index of variation among the pixels in the image was substantially correlated with the visual ranges in Incheon and Seoul with correlations of $R^2$=0.88 and $R^2$=0.71, respectively. The regression line equations between the visual range and the RMS index in Incheon and Seoul were VR=$2.36e^{0.46{\times}(RMS)}$ and VR=$3.18e^{0.15{\times}(RMS)}$, respectively. It was also confirmed that the fine particles ($PM_{2.5}$) have more impacts to the impairment of visibility than coarse particles.

Comparative Study of the Standard Plaque Assay with Solid-overlay and Immunofocus Assay for Varicella-zoster Virus Titration (수두바이러스의 정량에 있어서 Solid-overlay Standard Plaque Assay와 Immunofocus Assay의 효용성 비교 연구)

  • Lee, Hwa-Kyung;Jeong, Yong-Seok
    • The Journal of Korean Society of Virology
    • /
    • v.30 no.1
    • /
    • pp.61-70
    • /
    • 2000
  • Standard plaque assay using agarose-overlay has long been used for titration of many infectious virus particle. Plaque assay for the titration of varicella-zoster virus and its live vaccine requires three intermittent agarose overlay to visualize plaques. Overall procedure of the assay takes at least nine days from virus inoculation and microbe contamination including fungi is frequently accompanied during incubation period. We studied whether an immunofocus assay in conjunction with peroxidase-mediated immunohistochemical reaction may replace the standard plaque assay for the virus titration by comparing the two methods. A linear relationship was observed between number of foci and virus dilution. The number of foci in a given dilution of virus appeared a little higher than counted plaques formed in standard plaque assay. Independent titration results obtained from two assay methods for a given dilution of virus demonstrated a strong correlation ($r^2=0.99$). Foci of virus infected cells as revealed by the enzyme reaction could be counted either 4 days post-infection (p.i.) under low magnification (40X) microscopy, or 6 days p.i. by naked eye observation. Larger size of cell cuture plate, virus adsorption at $35^{\circ}C$, and 10% FBS in diluent appeared to be better conditions for the assay. Immunofocus assay will be an effective and dependable titration method for varicella-zoster virus and its live vaccine in place of the standard plaque assay in respect to accuracy, costs, and experimental convenience.

  • PDF

Sarcocystosis among Wild Captive and Zoo Animals in Malaysia

  • Latif, Baha;Vellayan, Subramaniam;Omar, Effat;Abdullah, Suliman;Desa, Noryatimah Mat
    • Parasites, Hosts and Diseases
    • /
    • v.48 no.3
    • /
    • pp.213-217
    • /
    • 2010
  • Sarcocystis sp. infection was investigated in 20 necropsied captive wild mammals and 20 birds in 2 petting zoos in Malaysia. The gross post-mortem lesions in mammals showed marbling of the liver with uniform congestion of the intestine, and for birds, there was atrophy of the sternal muscles with hemorrhage and edema of the lungs in 2 birds. Naked eye examination was used for detection of macroscopic sarcocysts, and muscle squash for microscopic type. Only microscopically visible cysts were detected in 8 animals and species identification was not possible. Histological examination of the sections of infected skeletal muscles showed more than 5 sarcocysts in each specimen. No leukocytic infiltration was seen in affected organs. The shape of the cysts was elongated or Circular, and the mean size reached $254{\times}24.5{\mu}m$ and the thickness of the wall up to $2.5{\mu}m$. Two stages were recognized in the cysts, the peripheral metrocytes and large numbers of crescent shaped merozoites. Out of 40 animals examined, 3 mammals and 5 birds were positive (20%). The infection rate was 15% and 25% in mammals and birds, respectively. Regarding the organs, the infection rate was 50% in the skeletal muscles followed by tongue and heart (37.5%), diaphragm (25%), and esophagus (12.5%). Further ultrastructural studies are required to identify the species of Sarcocystis that infect captive wild animals and their possible role in zoonosis.

Study on Mensurability of Internal Defect Prediction and of Classification of Log by NDE(Non-Destructive Evaluation) (I) - Focused on Cross Direction of Log - (비파괴 시험방법을 이용한 원목 내부결함 예측 및 분류의 계량화(計量化)에 관한 연구 (I) - 원목의 횡단방향을 중심으로 -)

  • Park, Heon;Gang, Eun-Chang;Chun, Sung-Jin;Yoon, Kyung-Seob
    • Journal of the Korean Wood Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.47-54
    • /
    • 1995
  • This study was to measure the properties of logs and classify them by non-destructive methods. The purpose of this experiment was focused at mensurability of logs by non-destructive methods. The non-destructive instrument, Stress-Wave Timer 239A which was made by Metriguard in U.S.A., was used. The stress wave velocities of log's cross direction were measured and compared with three different methods; 1. with hammer, 2. with hammer and D.B.H. meter, 3. with manufactured instrument. Number of used logs were seven logs, which were classified by naked eye into six groups; very severe rot, severe rot, mild rot & knot, mild rot & check, mild rot, sound log, and in diameter were into three groups; large(57.4cm), medium(36~41.2cm), small(28.9cm) log. The results, which were classified by mensurability with non-destructive methods, were followed; 1. The stress wave velocities were very different between rot and sound log. So it meant the possibility of mensurability of logs by non-destructive method even if high standard error. 2. The stress wave velocities decreased with checks more than with rots, which meant the checks affected speeds more. 3. The stress wave velocities increased with knot. 4. The velocities with manufactured instrument showed lower standard error, so more accurate results than other methods. Especially the required labour decreased from 3~4 to 2 persons. 5. Finally, the mensurability showed more accurate results and made the classification of logs scientific.

  • PDF

Fire Performance Testing Method for Fire Retardant EPS Sandwich Panel Using X-ray Analysis (X-선 분석법을 이용한 난연 EPS 샌드위치 패널의 화재성능평가 방법에 관한 연구)

  • Shim, Ji-Hun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.76-83
    • /
    • 2015
  • EPS sandwich panel contains flame retardants that slow down ignition during fires,reduce the amount of heat generated, and block the spread of combustion. However, if a sandwich panel does not satisfy standards for fire-retardant performance, it may increase damage to property and human life. It is difficult to test the fire-retardant performance of a finishing material with the naked eye, so it is necessary to develop convenient and fast evaluation methods that are convenient and fast. In this study, a fire safety evaluation method for EPS sandwich panel was analyzed using X-ray to detect specific components related to the fire-retardant performance X-ray fluorescence analysis (XRF) indicated that suitable panel products contained more aluminum in comparison to unsuitable products. Gibbsite was identified as the main crystalline material of flame retardant EPS through X-ray diffraction analysis (XRD) and was included in both suitable products and unsuitable products, but there was a difference in crystalline structure. This study was verifies the possibility of evaluating fire-retardant performance using ultimate analysis and crystal analysis through these X-ray methods.

The Effect of Microcurrent Stimulation on Histological Structure of Wound in Rat (미세전류전기자극이 흰쥐 창상의 조직학적 구조에 미치는 영향)

  • Oh, Hye-Jin;Kim, Jung-Woo;Kim, Moon-Su;Park, Jang-Sung
    • The Journal of Korean Physical Therapy
    • /
    • v.20 no.1
    • /
    • pp.67-73
    • /
    • 2008
  • Purpose: The purpose of this study was to investigate the effect of the intensity of microcurrent stimulation (with currents of 50 ${\mu}A$, 100 ${\mu}A$ and 300 ${\mu}A$ using a pulse frequency of 5 pps) on wound healing in rats. Methods: Sixty male Korean rats were randomly divided into four groups of 15 rats that were subjected to four different treatment protocols (control group, no treatment; experimental groups, treated with currents of 50 ${\mu}A$, 100 ${\mu}A$ or 300 ${\mu}A$). An experimental 20 mm linear wound was made in each animal and all animals in the experimental groups received microcurrent stimulation once a day for 20 minutes until the day of sacrifice on day 1, day 3 and day 6. An optical microscope was used to determine any histological changes. Results: The experimental results were as follows. 1. In an examination with the naked eye, all groups showed similar changes until the first day. However, from the third day, a little intercellular fluid soaked through wound region in the control group rats. In the experimental group animals, little intercellular fluid soaked through wound region, and swelling and redness did not appear, from the third day. 2. In an examination with histological evaluation, more significant changes were observed in all of the experimental group rats than the control group animals. Especially, a stimulation intensity of 50 ${\mu}A$ caused a more significant effect than the use of the other intensities by day 6 of wound healing. In addition, rapid recovery was observed. Conclusion: It was determined that microcurrent stimulation had a positive effect on wound healing. A stimulation intensity of 50 ${\mu}A$ was more effective than the other intensities (100 ${\mu}A$ and 300 ${\mu}A$) utilized for wound healing. Furthermore, low-intensity microcurrent stimulation was more effective for the purpose of wound healing.

  • PDF