• 제목/요약/키워드: Nagasaki

검색결과 294건 처리시간 0.026초

Flexible 3-dimension measuring system using robot hand

  • Ishimatsu, T.;Yasuda, K.;Kumon, K.;Matsui, R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.700-704
    • /
    • 1989
  • A robotic system with a 3-dimensional profile measuring sensor is developed in order to measure the complicated shape of the target body. Due to this 3-dimensional profile measuring sensor, a computer is able to adjust the posture of the robot hand so that complicated global profile of the target body can be recognized after several measurements from the variant directions. In order to enable fast data processing, a digital signal processor and a look-up table is introduced.

  • PDF

An approach for real-time 3-dimensional shape measurement of human head

  • Ishimatu, T.;Ohata, T.;Usiroda, H.;Taguchi, N.;Matui, R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.993-998
    • /
    • 1989
  • This paper describes a system which enables a fast 3-dimensional measuring of a human head using a slit-ray projection method . One feature of our system is that almost all calculations are executed using a look-up table, so that, forty thousands of sample point scan be processed in a few seconds. The feasibility of our system for practical applications is demonstrated measuring a human head.

  • PDF

Digital control of active magnetic bearing using digital signal processor

  • Shimomachi, T.;Ishimatsu, T.;Taguchi, N.;Fukata, S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.760-765
    • /
    • 1989
  • Digital control laws are implemented on an active magnetic bearing system with DSP. The results of tests using a experimental apparatus are (1) in a case that conventional PID, PIDD2 controls are employed, implemention of digital control law has similar characteristics to that of analogue control law. (2)The experiments reveal the results that the dynamic compensation based on the observer may be better than that of the other conventional controllers.

  • PDF

A THREE-DINENSIONAL MEASURING TECHNIQUE APPLIED TO FORGING PRESS MACHINE

  • Xiao, Sun;Shimomoto, Yoichi;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1995년도 Proceedings of the Korea Automation Control Conference, 10th (KACC); Seoul, Korea; 23-25 Oct. 1995
    • /
    • pp.138-141
    • /
    • 1995
  • This paper describes a 3-dimensional measuring method for cylindrical huge ingot pressed with forging machine. Target ingot we consider here is rotated around a fixed axis during measurement. Using an image processing technique every profile of cross-section is obtained, and 3D image is reconstructed. One method to calibrate the system setting is also presented. Experimental results reveal that the method are applicable and the algorithm is feasible.

  • PDF

Vibration control of active magnetic bearing systems using digital signal processor

  • Shimomachi, T.;Fukata, S.;Kouta, Y.;Ishimatsu, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1990년도 한국자동제어학술회의논문집(국제학술편); KOEX, Seoul; 26-27 Oct. 1990
    • /
    • pp.1178-1183
    • /
    • 1990
  • A digital signal processor(DSP) is applied to realizing a compensator of control system of active magnetic bearings, to restrict a resonance caused by the first-order bending vibration of a flexible rotor, and to run the rotor beyond the critical speed. A full-order observer is applied to the translatory rotor-motion with the first-order vibration mode. A PID control is used for the conical motion. The rotor used in the experiments is symmetric, and an electromagnet and a displacement sensor are set in collocation.

  • PDF

Cardiorespiratory responses to environmental hypoxia in the yellowtail, Seriola quinqueradiata

  • Lee, Kyoung-Seon;Atsushi Ishimatsu;Tatsuya Oda
    • 한국어업기술학회:학술대회논문집
    • /
    • 한국어업기술학회 2001년도 추계 수산관련학회 공동학술대회발표요지집
    • /
    • pp.265-266
    • /
    • 2001
  • Cardiovascular and respiratory responses of fish exposed to environmental hypoxia have on the subject of a number of investigations. Although relatively few species have been examined, generalized responses to ambient hypoxia include an elevation of blood pressure, increased systemic vascular resistance and bradycardia (Fritsche and Nilsson, 1990; Bushnell and Brill, 1991). The degree of bradycardia experienced by fish during hypoxia is highly variable and may depend upon the severity of the hypoxia and the rapidity with which it is imposed. (omitted)

  • PDF

Tele-Operation of Dual Arm Robot Using 3-D vision

  • Shibagami, Genjirou;Itoh, Akihiko;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.386-390
    • /
    • 1998
  • A master-slave system is proposed as a teaching device for a dual arm robot. The slave robots are remotely controlled by two delta-type master arms. In order to help the operator to observe the target object from the desired position and desired direction, cameras are mounted on a specialized manipulator, Movements of two slave arms are coordinated with that of the cameras. Due to this coordinated movements, the operator needs not to care the geometrical relation between the cameras and the slave robots.

  • PDF

Effect of Load and Sliding Speed on Corrosive Wear of Metals in Seawater

  • Kawazoe, T.;Ura, A.;Nakashima, A.;Moritaka, H.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.245-246
    • /
    • 2002
  • The objective of this study is to evaluate corrosive wear resistance of metals used for bearings and gears in seawater. Sliding wear test of ferrous and copper materials against $Al_2O_3$ were carried out in artificial seawater using an electrochemical potentiostat. As the results, the wear rate and the coefficient of friction of the copper materials are lower than those of the ferrous materials. The corrosive wear of stainless steel is remarkably affected by normal load and sliding speed in view of tribological characteristics including adhesion and corrosion products.

  • PDF

Communication device to use slight body movement for ALS patients

  • Fukuda, Yoshio;Yamanaka, Yuuki;Tanaka, Motohiro;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1963-1967
    • /
    • 2003
  • Communication device to use slight movement for serious disabled is proposed. This device is developed mainly for patients suffering from ALS or a cerebral infarction. They often have communication difficulty because of deterioration of muscular functions. Features of this device are that the device is wearable on the user’s body and that it detects the movement of eyebrow. Because of these features, it is quite easy to install the sensor on the patient’s body, not like the conventional sensors. Furthermore, an adaptive communication software is incorporated. A feature of this software is that the arrangement and size of the button and window on the display can be optimized depending on the user's physical ability. In the field test it is confirmed that the communication device developed in this study is successfully helped the people with disability for increasing their communication ability.

  • PDF

Application of 3-D Scanner to Analysis of Functional Instability of the Ankle

  • Han, Cheng-Chun;Kubo, Masakazu;Matsusaka, Nobuou;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1971-1975
    • /
    • 2003
  • This paper describes a technique, which analyzes the functional instability of the ankle using three-dimensional scanner. The technique is based on the structured light pattern projection method, which is performed by using one digital still camera and one LCD projector. This system can be easily realized with the low cost. The measuring result has high accuracy. The measuring error is about 0.2 mm or less. Using this technique the three-dimensional posture of the leg and foot of the target person are measured and analyzed.

  • PDF