• Title/Summary/Keyword: NaI(T1) detector

Search Result 18, Processing Time 0.031 seconds

An Analysis of ${\gamma}-ray$ Energy Spectra Using the NaI(T1) Scintillation Detector in the Air and Water (NaI(T1) 섬광검출기를 이용한 공기 및 수중에서의 감마선 에너지스펙트럼 분석)

  • Kim, Eun-Sug;Park, Jae-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.4
    • /
    • pp.285-296
    • /
    • 1996
  • The energy spectra in the air and water of several ${\gamma}-ray$ sources such as Cr-51, Cs-137, Mn-54, Zn-65 have been investigated using the NaI(T1) scintillation detector. General response functions, which can curve fit the measured spectra, have been constructed. We have found that the constructed response functions can successfully represent the measured spectra in the water as well as in the air, It is possible, by comparing the relevant parameters of the response functions, to quantitatively characterize the changing features of the measured spectra as obtained with varying the water depth. Of the response function parameters, those which affect the shape of the full-energy Peak have most notably changed. Besides, those parameters which affect the shapes of the flat continuum, the Compton continuum and edge have also shown slight changes with varying the water depth.

  • PDF

Application of an Energy Sensitive CZT Detector to a DXA Type of Bone Densitometer

  • Yoon, Je-Woong;Lee, Hyung-Koo;Lee, Heung-Kyu
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.422-424
    • /
    • 2002
  • The accuracy of DXA(Dual Energy X-ray Absorptiometry) highly depends on the detection and separation capability of dual energy X-ray X-ray photons. In addition both of scan time and patient exposure are affected by detection efficiency. A CZT detector with a good energy resolution and high detection efficiency was evaluated for the application of bone densitometry. Its performance was compared to a photomultiplier tube with a NaI(T1) scintillator in terms of energy resolution, detection efficiency and the accuracy of bone mineral density measurement. The comparison study was performed with CZT detector and PM tube using DXA equipments(OSTEO Plus, OSTEO Prima, ISOL Technology). The energy spectrum was acquired using MCA(Multi-Channel Analyzer). The used X-ray energy ranged from 20keV to 86keV. The MCA result of the CZT detector showed a slightly sharper energy spectrum than that of NaI(T1). Detection efficiency of the CZT detector at 59.5keV was 1.4 times better. Remarkably the final results of bone mineral density measurements demonstrate only less than 1% difference. The CZT detector appears to have many benefits for the application of bone densitometry. Its excellent energy resolution can enhance the counting accuracy of dual energy X-ray spectrum. Furthermore its compactness in physical dimension and no cooling requirement will be additional benefits for a more compact and accurate bone densitometer.

  • PDF

Field tests of the radiation detectors for environmental radiation monitoring around KORI nuclear power plants (고리원자력 주변 환경방사선 감시를 위한 방사선 측정기의 현장 성능 시험)

  • 최성수;신대용;조규성;하달규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1371-1374
    • /
    • 1997
  • We had developed the on-line environmental monitoring system which has installed around Kori Nuclear Power Plants and will be taken the place of the existing system. The system consists of a main computer and 11 sets of radiation monitoring post equipments. Nal(Tl) scintillation detectro was adopted in addition to ion-chamber detector and implemented with DCU(Dose Conversion Unit) and SCA(Single Channel Analyzer). Compared with the existing system, it has revised feature in the radiation measurements which are detection of artificial radioactivity and 2-ways of the radiatiion detectors. The field test trsults show that the developed radiation detecting equipments can measure environmental radiation withn 5.0% of the theoretical value.

  • PDF

Radioactive Nuclide Identification of a Fall-Out Sample in Korea (放射能 落塵의 核種檢出의 一例)

  • Kim, Chong-Kuk
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.155-157
    • /
    • 1962
  • A tiny dust found at the balcony of the Institute indicated about 8,0000 counts per minute by T.G.C.-2 Geiger-Muller tube (1.8mg/$cm^2$ window-thickness) at the distance of 2cm from the window. The main fission fragments, as identified by the present analysis, are 12.5day Ba-140 and 33.1 day Ce-141. The gamma energies were determined using $2"{\times}2"$ NaI(Tl) scintillation detector connected to RCL-256 channel pulse heigt analyzer. The beta energies were evaluated by Feather plot.

  • PDF

Automatic Determination of the Energy Pulse-height Relationship in NaI(TI) Spectra (NaI(T1) 검출기 스펙트럼의 에너지-채널 관계 자동결정)

  • Lee, M.S.
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.3
    • /
    • pp.143-151
    • /
    • 1997
  • As the pulse heights from a NaI(Tl) detector vary with the temperature of the measuring environment a significant change in temperature may affect the energy calibration of the spectrometer. The auto-adjustment of the channel corresponding to a pulse heights can be achieved by introducing an external reference source to compensate the temperature dependency of pulse heights, but unfavorable increases of the Compton continuum are caused due to the external source. In this study, the total absorption peaks dominant in the typical environmental gamma spectrum-239 keV from $^{212}Pb$, 351 keV from $^{214}Pb$, 1460 keV from $^{40}K$ and 2614 keV from $^{208}Tl$ for examples - were used as reference in the correction of energy calibration. With these peaks, the program to calibrate the energy of the s spectrum was developed using Microsoft Visual Basic language. The program developed here was applied to the environmental spectra measured at intervals of 30 minutes in the temperature range of from $-20^{\circ}C$ to $10^{\circ}C$ to demonstrate the validity and applicability. As a result of the test, the correction scheme appeared to be effective in the temperature changes encountered in the usual environment.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

A Fast Neutron Time-of-Flight Spectrometer with High Resolution

  • Cho, Mann
    • Nuclear Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.116-131
    • /
    • 1972
  • A fast neutron time-of-flight spectrometer has been constructed with suitable choice of target thickness and proton bombarding energy in Li$^{7}$ (p, n) Be$^{7}$ nuclear reaction for a continuous keV spectrum of neutrons at 0 degree in 1-nsec pulse from a Van do Graaff and a time-pick-up fast neutron detector assembled with a 5 mm-thick 92% enriched B$^{10}$ slab and four heavily shielded 4"$\times$3" NaI scintillation detectors. Energy resolution of this spectrometer is better than 0.3% at 50 keV and the signal-to-background ratio is also improved. Total cross section measurements of several separated single isotopes have been carried out with this spectrometer and analyzed by Rmaxtrix multi-level computer code. The spin values and resonance parameters of each individual resonances are given.

  • PDF

Fiber Volume Fraction Measurement of Fiber Reinforced Plastics by Using Gamma-Ray (감마선을 이용한 복합재료의 섬유체적분율 측정)

  • Jang, J.H.;Cho, K.S.;Chang, H.K.;Park, J.H.;Lee, J.O.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.17 no.3
    • /
    • pp.151-155
    • /
    • 1997
  • In this research, nondestructive test using a radioisotope, $^{241}Am$ gamma-ray, was accomplished in order to evaluate the fiber volume fraction of the accumulated composite layers such as glass fiber/epoxy and carbon fiber/epoxy. Attenuation coefficients of the fiber and resin were measured respectively by NaI(T1) detector The fibers volume fraction was measured for various thickness of composite layers between 2 and 20mm. Fiber volume fraction of the composite layers were also measured for various amount of fibers. The experimental errors from nondestructive test using gamma-ray were in the range of ${\pm}1{\sim}2.5%$ in comparison with those from observation by optical microscopy. By selecting the optimum energy and activity of radioisotope, this method can provide a new means for the evaluation of the fiber volume fraction.

  • PDF

A Simultaneous Determination of Chromium, Iron, Lanthanum, Scandium and Zinc in River Water by Neutron Activation (중성자 방사화에 의한 시료중의 크롬, 철, 란탄, 스칸듐 및 아연의 동시정량)

  • Lee Ihn Chong;Kim Si-Joong;Lee Chul
    • Journal of the Korean Chemical Society
    • /
    • v.21 no.6
    • /
    • pp.427-433
    • /
    • 1977
  • A neutron activation method has been developed for the simultaneous determination of chromium, iron, lanthanum, scandium and zinc in river-water samples. The sample is sealed in the silica ampoule without pretreatment and irradiated for a week at a thermal neutron flux of $1{\times}10^{13}n{\cdot}cm^{-2}{\cdot}sec^{-1}$. After cooling for about two days, the elements in the sample are sequentially extracted at different pH by 0.1M oxine-chloroform solution. The organic layers are checked by Gamma-ray spectrometry with $″3\;{\times}\;3″$ NaI (T1) detector connected to a 800-channel pulse hight analyzer. The ppb concentration of the elements in most of river-water samples could be determined by this method. The tracer study for the quantitative separation of the elements was also carried out.

  • PDF

A Study on the Nuclear Structure through the Multipurpose Coincidence Measurement System Development (II) - Double ionization of the K-shell in $^{125}I$- (다목적 동시측정 장치 개발에 의한 원자핵 구조 연구 (II) - $^{125}I$ 붕괴시 K 각 이중 이온화 현상 -)

  • Chung, Won-Mo;Chung, Kap-Soo;Joo, Koan-Sik;Nam, Kie-Yong;Choi, Hey-Jin;Jeon, Woo-Ju;Na, Sang-Kyun;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.1
    • /
    • pp.63-70
    • /
    • 1993
  • Double ionization of the K- shell accompanying K- shell electron capture of the 0.035 MeV transition of $^{125}I$ has been studied by counting coincidences between $K_{\alpha}$ hypersatellite X-rays and Ka satellite X-rays emitted when double vacancies are filled. The $^{125}I\;and\;^{125}Te^m$ source materials were used in the measurement. We obtained the coincidence spectrum using two NaI(T1) detectors and a Ge(Li) detector and TAC(Time-to-Amplitude Converter), and then analysed the measured coincidence number $N(K_{\alpha}^{II},\;K_{\alpha}^s)$, the total number $N(K_{\alpha})$ of K X-ray. The probability per K-shell electron capture that a double vacancy is formed, $P_{KK}$ is formed, $P_{KK}$ is found to be $2.15{\times}10^{-4}$.

  • PDF