• Title/Summary/Keyword: NTU

Search Result 315, Processing Time 0.023 seconds

Three-dimensional human activity recognition by forming a movement polygon using posture skeletal data from depth sensor

  • Vishwakarma, Dinesh Kumar;Jain, Konark
    • ETRI Journal
    • /
    • v.44 no.2
    • /
    • pp.286-299
    • /
    • 2022
  • Human activity recognition in real time is a challenging task. Recently, a plethora of studies has been proposed using deep learning architectures. The implementation of these architectures requires the high computing power of the machine and a massive database. However, handcrafted features-based machine learning models need less computing power and very accurate where features are effectively extracted. In this study, we propose a handcrafted model based on three-dimensional sequential skeleton data. The human body skeleton movement over a frame is computed through joint positions in a frame. The joints of these skeletal frames are projected into two-dimensional space, forming a "movement polygon." These polygons are further transformed into a one-dimensional space by computing amplitudes at different angles from the centroid of polygons. The feature vector is formed by the sampling of these amplitudes at different angles. The performance of the algorithm is evaluated using a support vector machine on four public datasets: MSR Action3D, Berkeley MHAD, TST Fall Detection, and NTU-RGB+D, and the highest accuracies achieved on these datasets are 94.13%, 93.34%, 95.7%, and 86.8%, respectively. These accuracies are compared with similar state-of-the-art and show superior performance.

Numerical Model Development of a Microchannel Condenser for Mobile Air-Conditioning Systems (자동차용 에어컨의 마이크로채널 응축기의 수치적 모델 개발)

  • ISHAQUE, SHEHRYAR;ULLAH, NAVEED;CHOI, JUN-HO;KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.4
    • /
    • pp.430-436
    • /
    • 2022
  • This paper presents the numerical model development of a microchannel heat exchanger in mobile air-conditioning and heat pump applications. The model has been developed based on the effectiveness-NTU method using a segment-by-segment modeling approach. State-of-art correlations are used for refrigerant- and air-side heat transfer coefficients and pressure drops. The calculated heat condenser capacities are in good agreement with experimental data, with an average difference of 1.86%. The current model can be used for microchannel condenser simulations under various operating conditions. It is anticipated to improve productivity in designing and optimizing microchannel heat exchangers with folded louver fin geometry.

Study of the Performance of the Fin-Tube Heat Exchanger of the Miniature Joule-Thomson Refrigerator (쥴톰슨냉동기의 열교환기 성능에 관한 연구)

  • Hong, Yong-Ju;Kim, Hyo-Bong;Park, Seong-Je;Choi, Young-Don
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.55-59
    • /
    • 2009
  • Miniature Joule-Thomson refrigerators have been widely used for rapid cooling of infrared detectors, probes of cryosurgery, thermal cameras, missile homing head and guidance system, due to their special features of simple configuration, compact structure and rapid cool-down characteristics. The thermodynamic performance of J-T refrigerator highly depends on the hydraulic and heat transfer characteristics of the recuperative heat exchanger. The typical recuperative heat exchanger of the J-T refrigerator has the double helical tube and fin configuration. In this study, effectiveness-NTU approach was adopted to predict the thermodynamic behaviors of the heat exchanger for the J-T refrigerator. The thermodynamic properties from the REFPROP were used to account the real gas effects of the gas. The results show the effect of the operating conditions on the performance of the heat exchanger and refrigerator for the given heat exchanger. The influences of mass flow rate and the supply pressure on the effectiveness of heat exchanger and the ideal cooling capacity are discussed in details.

Comparing Flotation Efficiency of Algae-Containing Raw Water using PAC Coagulants (PAC 응집제 종류에 따른 조류가 포함된 상수원수의 부상분리효율 비교)

  • Jong-Won Park;Seong-Kee Min;Hye-Yeon Lee;Churl-Jong Yun;Chang-Han Lee
    • Journal of Environmental Science International
    • /
    • v.32 no.5
    • /
    • pp.355-363
    • /
    • 2023
  • This study used a batch DAF (dissolved air flotation) jar tester to evaluate the algae removal efficiency of alum and PAC coagulants during coagulation, flocculation, and flotation. Optimal coagulant dosages were 0.06 ~ 0.15 mL/L (12.0 ~ 26.0 mg Al/L,17%), 0.08 ~ 0.20 mL/L (10.0 ~ 24.0 mg Al/L, 12%), 0.25 ~ 0.30 mL/L (25.0 ~ 30.0 mg Al/L, 10%) for PAC, and 3.0 ~ 5.0 mL/L (81.0 ~ 135.0 mg Al/L, 2.7%) for alum. Turbidity of treated water was 1.0 ~ 2.0 NTU in optimal coagulation, flocculation, and flotation conditions for the four coagulants types. The amount of coagulant injected tended to decrease with increasing Al content in the coagulant, as follows : 17% PAC < 12% PAC < 10% PAC < 2.7% alum. Turbidity removal efficiencies were in the order of 12% PAC (93.6%) > 10% PAC (92.7%) > 17% PAC (91.3%) > 2.7% Alum (88.1%).

Aqua-Aware: Underwater Optical Wirelesss Communication enabled Compact Sensor Node, Temperature and Pressure Monitoring for Small Moblie Platforms

  • Maaz Salman;Javad Balboli;Ramavath Prasad Naik;Wan-Young Chung;Jong-Jin Kim
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.50-61
    • /
    • 2022
  • This work demonstrates the design and evaluation of Aqua-Aware, a lightweight miniaturized light emitting diode (LED) based underwater compact sensor node which is used to obtain different characteristics of the underwater environment. Two optical sensor nodes have been designed, developed, and evaluated for a short and medium link range called as Aqua-Aware short range (AASR) and Aqua-Aware medium range (AAMR), respectively. The hardware and software implementation of proposed sensor node, algorithms, and trade-offs have been discussed in this paper. The underwater environment is emulated by introducing different turbulence effects such as air bubbles, waves and turbidity in a 4-m water tank. In clear water, the Aqua-Aware achieved a data rate of 0.2 Mbps at communication link up to 2-m. The Aqua-Aware was able to achieve 0.2 Mbps in a turbid water of 64 NTU in the presence of moderate water waves and air bubbles within the communication link range of 1.7-m. We have evaluated the luminous intensity, packet success rate and bit error rate performance of the proposed system obtained by varying the various medium characteristics.

The Investigation of Rainwater Quality Variation and Rainfall Characteristic for the Effective Usage (우수이용 효율화를 위한 수질변화와 강우특성 검토)

  • Lee, Chang Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3B
    • /
    • pp.355-361
    • /
    • 2008
  • A water quality analysis of rainwater collected from catchment equipment ($2m{\times}1m$) was conducted to determine its suitability for domestic purposes, in this study. As the results of analysis, the pH of rainwater was $6.3{\pm}0.3$, and the turbidity of rainwater was over the 5 times than drinking water guidelines. For the usage of rainwater as the domestic and drinking water, the rainwater is need to treat. The analysis values of heavy metal as the Pb, Cd, Fe, Mn, ${Cr_6}^+$ and Cu was satisfied with drinking guidelines. Rainwater quality was improved in the rainfall duration. Overall results of analysis support the possibility of rainwater as the domestic and drinking water.

An assessment on feasibility of flotation as a secondary clarifier of an activated sludge process (생물반응공정에 대한 고액분리조로서 부상공정의 적용성 평가)

  • Chung, Chong Min;Kim, Yun Jung;Cho, Kang Woo;Lee, Sang Hyup;Hong, Seok Won;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.551-559
    • /
    • 2008
  • An experimental study was carried out to evaluate the potential of flotation process for the secondary clarifier of an activated sludge process. Flotation techniques, applied in this study, include electrofloation (EF) which generated fine bubbles smaller than $35{\mu}m$ in average and diffuser flotation (DF) which generated fine bubbles smaller than $55{\mu}m$ in average. The batch experiments were done with activated sludge displaying various characteristics. It was shown that the efficiency of solids/liquid separation was reduced as the diluted sludge volume index ($DSVI_{30}$) of activated sludge increased. The dependency, however, gradually decreased as the gas to solids (G/S) ratio increased. Thickening efficiency of EF was more than 2~10 times and DF process was more than 1.5~5 times as compared with gravity sedimentation (GS). Stable sludge blanket was maintained regardless of sludge settleability when the G/S ratio was 0.019 in the EF. On the other hand, Serious deterioration in the sludge blanket was observed in the DF depends on G/S ratio and sludge settleability. And For EF and DF, the suspended solids concentration of effluent was not nearly influenced on settleability of activated sludge and more clear than GS. A biological nutrient removal (BNR) process, combined with EF as a secondary clarifier was operated for three months. The mean MLSS (mixed liquid suspended solids) concentration in the reactor and mean solids concentration of return sludge were estimated to be 5,340 mg/L and 16,770 mg/L, respectively. The water quality of effluent was considerably stable and low value was accomplished, that was, standard suspended solids concentration $0.07{\pm}0.51mg/L$ and standard turbidity $1.44{\pm}0.56NTU$. The EF could be applicable for enhancement of efficiency of activated sludge system as well as improvement of the water quality of effluent.

Distribution of Acanthamoeba spp. in Raw Water and Water Treatment Process (상수원수 및 정수처리공정별 가시아메바 분포특성에 관한 연구)

  • Jung, Eun-Young;Jung, Mi-Eun;Park, Hong-Gi;Jung, Jong-Moon;Rho, Jae-Sun;Ryu, Pyung-Jong
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1121-1127
    • /
    • 2008
  • The free-living amoeba and Acanthamoeba sp. are widely distributed in fresh water, soil, air and dust in the world. We studied distribution of amoeba from low Nakdong River(Mulgum and Maeri) and removal efficiency in water treatment process of Busan metropolitan city. During this investigation, water quality showed pH $7.4{\sim}9.6({\pm}1.1)$, water temperature $2.0{\sim}29.0({\pm}17)^{\circ}C$, turbidity $4.8{\sim}27.4({\pm}11.0)$ NTU, chlorophyll-a $10.3{\sim}109.0({\pm}44.3)\;mg/m^{3}$, BOD $1.7\sim4.9({\pm}2.6)$ mg/L, COD $3.1\sim-6.9({\pm}5.0)$ mg/L and total coliform $17\sim920({\pm}200.5)$ MPN/100 mL. The free-living amoeba were detected highly than Acanthamoeba sp., 11 out of 22 in raw water samples were positive (50%) for Acanthamoeba sp. from February 2005 to December 2005. The seasonal characteristics of tree-living amoeba and Acanthamoeba sp. in raw water were mainly distributed through the spring to the early fall. When tree-living amoeba and Acanthamoeba sp. were passed through the water treatment of pilot-plant, approximately 80% was sure to be removed through pre-ozonation, sedimentation, send filtration. 100% was removed after post-ozonation process. All of the isolated amoebas from Nakdong River were Acanthamoeba sp. AC311 18S ribosomal RNA gene with 98% nucleotide sequence homology.

A study on sanitary emprical for specific property removal of pollution material inter a water tank by ozone (오존을 이용한 수조속의 오염물질 제거특성에 관한 실험적 연구)

  • Lee, Kwan-young;Ahn, Seoung-Seop;Park, Sang-hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 2002
  • In this study, the initial number of bacteria before ozone sterilizing shows 290 per $1m{\ell}$ in RUN 1 and RUN 2 equally, but the removal rate shows more than 50% in RUN 1, and 100% in RUN 2 respectively when ozone injection amount is $0.28mg/{\ell}$. It is regarded as a satisfactory result that E-coli concentration without ozone contact is 890, rapid removal effect of E-coli is observed in $0.28mg/{\ell}$ of ozone, and E-coli is removed perfectly in $0.84mg/{\ell}$ of ozone. It is thought that an excellent efficiency is obtained for vibrio alginolyticus because the initial number of bacteria before ozone contact is positive, but it is altered to negative after ozone contact. CODcr shows the tendency which is somewhat reduced as the ozone injection is increased, but the general effect is appeared not so much, and it is thought that the tendency is caused by the reason that sea water contains much salt which is estimated as a component of CODcr, therefore it is regarded that ozone contact has not an important effect on salinity. It is thought that the frequency of changing salt water in the fish preserve of a sliced raw fish restaurant can be reduced to under the standard because NTU of 7 days after sea water injection is 0.70 in the experiment of turbidity, hut more than 50% of turbidity removal efficiency is appeared at $0.28mg/{\ell}$ of ozone injection, and it shows 70% at $0.84mg/{\ell}$ of ozone injection in RUN 1 and RUN 2 commonly.

  • PDF

Impact of Design Parameters on Length and Application Effect of Surface Water Heat Exchanger(SWHE) (지표수 열교환기의 용량과 적용 효과에 대한 설계 인자의 영향)

  • Sohn, Byonghu;Min, Kyong-Chon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.4 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Commercial buildings are generally cooling-dominated and therefore reject more heat to a vertical ground heat exchanger(GHE) than they extract over the annual cycle. Shallow ponds can provide a cost-effective means to balance the thermal loads to the ground and to reduce the length of GHE. The objective of this work has been to develop a design tool for surface water heat exchanger(SWHE) submerged in shallow pond. This paper presents the analysis results of the impact of design parameters on the length of SWHE and its application effect on geothermal heat pump(GHP) system using vertical GHE. In order to analysis, We applied ${\epsilon}-NTU$ method on designing the length of SWHE. Analysis results show that the required pipe length of SWHE was decreased with the increase of approach temperature difference and with the decrease of pipe wall thickness. In addition, when the SWHE was applied to the GHP system, the temperature of vertical GHE was more stable than that of standalone GHE system.