• Title/Summary/Keyword: NOx gas

Search Result 1,118, Processing Time 0.03 seconds

The Study for Designs of Lean-Premixed low NOx Combustor (희박-예혼합 저 NOx 연소기 설계에 대한 연구)

  • Lim, Am-Ho;Kim, Han-Suck;Ann, Kuk-Young;Lee, Sang-Min;Kim, Yong-Mo
    • 한국연소학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.83-88
    • /
    • 2003
  • The concept of lean-premixed combustion in gas turbine combustor operation has become a standard in recent years as an effective means to meet stringent environmental standards on NOx emissions. Various types of air-fuel premixer, which affect greatly NOx emission and stability of lean-premixed low NOx combustor, were investigated experimentally to reduce the NOx emission. One type of the premixers is selected by experiments and applied it to 70kW class lean-premixed gas turbine combustor. The exit temperature and emissions of CO and NOx were measured with equivalence ratios at ambient pressure. From the results, the emissions of CO and NOx were influenced by the type of air-fuel premixer. As the mixing length of air and fuel is longer, the NOx and CO emission were decreased in the primary reaction zone. Compared with of conventional combustor, the lean-premixed low NOx combustor has low NOx emission characteristics.

  • PDF

A Study of NOx Removal in Flue Gas by Selective Catalytic Reduction (선택적 촉매환원법에 의한 배기가스중 NOx 저감에 관한 연구)

  • 박해경;김경림;최병선;이인철;최익수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.38-46
    • /
    • 1988
  • NOx is an important air pollution material which is generated when fossil fuels are burning, NOx removal in flue gas by selective catalytic reduction was studied over various catalysts in a fixed bed continuous flow reactor. The ranges of experimental conditions were at the temperatures between $200^\circ$C and $350^\circ$C, the $NH_3/NOx$ mole ratios between 0.8 and 1.4, oxygen concentrations between 1.5% and 3% and the space velocities between 5, 000 $hr^-1$ and 12, 500 $hr^-1$. The efficiency of NOx removal in the ranges of experimental conditions was highest at the temp. of 300$^\circ$C, oxygen concentration of 2.5-2.6% and $NH_3/NOx$ mole ratios of 1.0-1.2. The catalyst with high activity for NOx removal in flue gas was found to be $MoO_3-V_2O_5/TiO_2$.

  • PDF

NOx Gas Absorption in the Green Tobacco

  • Oh, In-Hyeog;Michael D. Boyette
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.26 no.1
    • /
    • pp.64-72
    • /
    • 2004
  • On-going research has recently documented the certain tobacco specific nitrosamines (TSNAs) are formed during the curing process by an interaction of nitrogen oxides (NOx) contained in combustion gases and naturally occurring compounds in the tobacco leaves. Although the role of TSNAs in human health have been extensively investigated, little research has been conducted on the physical and chemical phenomena relating to their formation during curing. In this paper, we developed a mathematical model for describing NOx absorption into green (uncured) tobacco. We found considerable uptake of NOx by green tobacco with variations related to several factors. Specifically, tobacco from the lower stalk positions (bottom one third) absorbs more NOx gas per unit weight than tobacco from upper stalk positions. Additionally, the green tobacco packed with a density of 0.103 g/㎤ absorbs more NOx gas per unit weight than either 0.0443 g/㎤ or 0.0739 g/㎤. Further, the NOx absorption increases proportionally with temperature with the maximum absorption point around 4$0^{\circ}C$.

Nox reduction of exhaust gas using corona discharge (코로나방전을 이용한 배기가스중의 Nox제거)

  • 김종달;박재윤;고희석
    • Electrical & Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.721-726
    • /
    • 1995
  • In this paper, reduction characteristics of NOx gas produced from diesel engine combustion is studied by using pulse corona discharge. Nox concentration of 1900ppm (NO 1870, NO$\sub$2/ 30 ppm, N$\sub$2/ balance gas) was controlled in a fixed quantity of 280ppm, using a flow meter. Reactors are composed of cylinder type. NOx reduction rate is investigated with discharge electrode diameter[0.5,1,3,4.phi.], reactor length [130,300mm], reactor materials[Copper, Poly Vinyl Chloride] and Input voltage[DC, AC, DC Pulse square voltage]. In the result, NOx reduction rate is the best of all in copper reactor, small electrode diameter[0.5.phi.], DC pulse voltage and long reactor[300mm]. Then Teduction rate of NOx is about 93%.

  • PDF

Fabrication of Fiber Gas Sensor and Analysis of NOx Gas Detection Characteristics (화이버 가스 센서 제작 및 NOx 가스 검출 특성 분석)

  • Son, Ju Hyeong;Kim, Hyun Soo;Yoon, Young Ki;Jang, Kyung Uk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.5
    • /
    • pp.432-436
    • /
    • 2019
  • In this study, we produced a light, flexible, wearable gas sensor by depositing MWCNTs (Multi-walled Carbon Nanotubes) into nylon. MWCNTs are widely used as a gas sensor material due to their excellent mechanical, electrical and physical characteristics. We produced a gas sensor to detect NOx gases by depositing nylon yarn in a MWCNT solution. The MWCNT solution was made by mixing 3 mg MWCNT in 5 ml of ethanol. Nylon yarn was placed in the manufactured solution and ultrasonic waves were applied using an ultrasonicator for 3 h, resulting in MCWNT deposition. The MWCNT-deposited nylon yarn was dried at room temperature for 24 h. The MWCNT-thin-film-coated nylon yarn was masked 1 mm apart, and gold was then deposited on the masked nylon yarn to create the gas sensor. The sensor then was installed in a chamber with a controlled atmospheric environment and exposed to NOx gas. The changing signal from the sensor was amplified to analyze its gas detection characteristics.

Control of SCR System for NOx Reduction in a Refuse Incineration Plant Using Repetitive Control Method (반복제어법을 이용한 소각장 NOx 저감용 SCR 시스템의 제어)

  • 김인규;여태경;김환성;김상봉
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.11
    • /
    • pp.2762-2770
    • /
    • 2000
  • The refuse incineration plant has an important role in saving the combustion energy for local heating system. But harmful combustion gas(NOx etc.) leads to some serious environmental problem. To reduce the gas, a SCR(Selective Catalytic Reduction)system is installed and it is controlled by adjusting the flow of ammonia gas(NH3) . In this paper, we apply a repetitive control method to reduce NOx by adjusting the flow of ammonia gas for SCR system in a refuse incineration plant which is located in Haeundae, Pusan, Firstly, we analyze the inlet NOx period by FFt method, and verify its periodic variations. Secondly, we design a repetitive control system by using state space model method. Lastly, the effectiveness of repetitive control system is shown by comparing to a conventional PID control in simulation and experimental results.

An Experimental Study on NOx Emission under the High Temperature Air Combustion with Oil (오일이용 고온공기 연소시 NOx 저감기술)

  • Yang, J.B.;Kim, W.B.
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.81-88
    • /
    • 2002
  • It's well known that with the increase of preheated air temperature NOx is increasing ,while the energy consumption is decreasing. In this study the experimental study was carried out to find out a new method breaking the above-mentioned old concept. From the variation of configuration of gas nozzle and hot test on the temperature distribution and NOx, it was found out that the reduction of NOx was due to the effect of internal gas recirculation, which will be caused by air emitting velocity from burner nozzle.

  • PDF

Research about room air quality of department store underground parking lot (백화점 지하 주차장의 실내 공기질에 관한 연구)

  • Kim Ki-Tae;Yang Sung-Su;Son Bu-Soon;Jeon Young-Taek;Jang Bong-Ki;Lee Jong-Dae
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.1 s.59
    • /
    • pp.44-51
    • /
    • 2006
  • This study was conducted to investigate air quality in the underground parking lot of department store. Sampling sites were selected to the three sites in one department store. Measuring instrument started from November 3rd, 2005 to November 9, 2005. Target air quality parameters include a number of criteria pollutants such as NOx, $O_3$. The purpose of this study was to find out the present condition of indoor air quality in underground parking space of department store. Through the field measurement, the current situation and the behavior of contaminants were investigated and then was compared with the advice standards. The result of this study was as follows; The Average density of NOx gas and $O_3$ gas was maintained below the indoor air advice standards. The Average density of NOx gas and $O_3$ gas was highly measured during the weekend than during the week day. Average density of NOx gas and $O_3$ gas was highly measured at daytime than that of afternoon. Average density of NOx gas was highly measured in the center area than the other area. Average density of $O_3$ gas was highly measured at the entrance than the other area. NOx gas concentration was maintained below 0.3ppm, an average for 1 hours, as defined in the parking space law. $O_3$ gas concentration was maintained below 0.08ppm, an average for 1 hours, as defined in the parking space law.

Low NOx MILD Combustion for Sawdust Fuel (폐목 톱밥 연료의 저NOx MILD연소)

  • Shim, Sung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.153-156
    • /
    • 2008
  • MILD combustion has been successfully applied to gaseous fuels and few commercial systems are now in operation. Extending MILD combustion applicability to solid fuel of sawdust is the focus of the present work. The MILD combustion furnace at the University of Adelaide in Australia was used in this study. A measurement of $O_2$ and CO emissions have been carried out in parallel with consideration of NOx emission and compared in each modes of conventional natural gas combustion, natural gas MILD combustion, NOx emission in natural gas MILD combustion mode can be reduced to 20% in comparison with conventional combustion. Emission in cases of air carrying sawdust combustion and $CO_2$ carrying sawdust combustion were also compared. Air and $CO_2$ were sued as a carry gas for the sawdust. It was found that MILD conditions are possible for sawdust particles of less than $355{\mu}m$ without additional air pre-heating. It was also found that when using $CO_2$ as the carry gas the flame inside the furnace was not visible anymore and that NOx emission dropped to less than two folds.

  • PDF

An Experimental Study on NOx Reduction in Exhaust Gas from Agricultural Diesel Engine with Plasma and Catalyst (플라즈마와 촉매를 이용한 농용 디젤기관 배기가스 중의 NOx 저감에 관한 실험적 연구)

  • 이승규;조기현;황의현
    • Journal of Biosystems Engineering
    • /
    • v.24 no.6
    • /
    • pp.465-472
    • /
    • 1999
  • To remove nitrogen oxides(NOx) in exhaust gas of diesel engine, three-way catalytic process with plasma discharger has great possibilities. Characteristics of NOx removal depends on NO conversion to NO$_2$and/or HNO$_3$due to high activation energies for NO oxidation and reduction. NOx removal efficiency by using three-way catalytic with plasma discharger indicated about 50% at 40watt power consumption condition.

  • PDF