• Title/Summary/Keyword: NO determination

Search Result 1,450, Processing Time 0.029 seconds

Attitude Determination Algorithm Design and Performance Analysis for CNUSAIL-1 Cube Satellite (CNUSAIL-1 큐브위성의 자세결정 알고리듬 설계 및 성능분석)

  • Kim, Gyeonghun;Kim, Seungkeun;Suk, Jinyong;Kim, Jong-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.7
    • /
    • pp.609-618
    • /
    • 2015
  • This paper discusses the attitude determination of the CNUSAIL-1 cube-satellite. The primary mission of the CNUSAIL-1 is sail deployment and operation in low Earth orbit, and the secondary mission is to look into influence of the sail deployment on satellite attitude and orbit. The attitude determination strategy is proposed depending on three mission phases, and its performance and applicability are verified through numerical simulations. This study considers the following sensors: Sun sensors and a three-axis magnetometer as attitude reference sensors, and a three-axis MEMS gyroscope as an inertial attitude sensor. Because sensors used for cube satellites have relatively low performances and worse noise characteristics, an Extended Kalman filter (EKF) is applied to attitude determination. Additionally, it has the merits to deal with the Gaussian noises and to predict the attitude even with no measurements from reference attitude sensors, especially in the eclipse of the cube satellite. The performance of the EKF is compared to a deterministic attitude determination technique, QUEST(QUaternion ESTimation).

Confirmation of Male Specific Fetal Free RNA in Maternal Plasma and Comparison of Accuracy on the Sex Determination using Real-time PCR Method in Korean Native Cattle

  • Lee, Sang-Ho;Park, Chul-Ho;Park, Jun-Tae;Park, Sang-Guk;Lee, Jin-A;Suh, Guk-Hyun;Oh, Ki-Seok;Son, Chang-Ho
    • Journal of Embryo Transfer
    • /
    • v.28 no.4
    • /
    • pp.343-348
    • /
    • 2013
  • Cell-free fetal RNA has been highlighted as useful tools for the fetal sex determination or other genetic inherent disorder. However, there is no knowledge about the sex determination using cell free fetal RNA in bovine field. Thus, the present study aimed to evaluate the presence of transcripts of DDX3Y, USP9Y and ZRSR2Y genes in maternal plasma of pregnant cows to determine the sex of the fetus using real-time quantitative polymerase chain reaction assay, and verify its accuracy, sensitivity and specificity compared with the molecular testing and the calf sex at birth. Transcripts of USP9Y and DDX3Y genes were expressed in the all plasma of males and females both the control group and the experimental group. However, ZRSR2Y gene was matched up with the molecular testing and the true sex in control group and has an overall accuracy of 82.6%, a sensitivity of 75%, and a specificity of 100% in experimental group. Therefore, these results indicated that real time PCR technique, as a noninvasive and cost-efficient method, is possible to determination fetal sex in the bovine species using circulating cell free RNA in maternal plasma and especially ZRSR2Y gene could be a good candidate for the RNA based sex determination work.

Wi-Fi-Based Low-Complexity Floor Number Determination Method Based for Multistory Buildings (다층 건물을 위한 Wi-Fi 기반의 저 복잡도 층간 위치 측위 기법)

  • Shi, Jian;Li, Xiang;Jung, Honggyu;Kim, Jinoh;Shin, Yoan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • Floor number determination has attracted considerable attention because many applications require accurate floor number information for providing better localization services in multistory buildings. This paper describes a Wi-Fi-based, low-complexity floor number determination method for multistory buildings. In our scheme, with the exception of floor ID and received signal strength of each WAP, detailed information on the wireless access point (WAP) coordinates is not needed. The multi-wall-floor model is used for the simulation and analysis. The simulation results show that the floor determination accuracy is nearly 100 given an adequate deployment density of WAPs on each floor. The results also show that the proposed method provides a good estimate of floor number even when only a few WAPs are implemented on each floor. Specifically, the proposed method can work under extreme conditions, i.e., where there are no WAPs on a floor.

A study on the Determination and Solvent Extraction Efficiencies of Rare Earth Elements by TBP and Nitrate Salt (TBP와 질산염을 이용한 희토류원소의 용매추출과 분석에 관한 연구)

  • Lee, Jung Min;Lee, Yong Ju;Kim, Sook Young;Kim, Young Man;Choi, Beom Suk
    • Analytical Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.103-108
    • /
    • 2001
  • Rare earth elements(REE) were separated by solvent extraction with tri-n-butyl phosphate(TBP) and $NaNO_3$, followed by back extraction with water. The method was applied to the determination of REE to circumvent the spectral interferences of ICP-AES analysis. The effects of the $NaNO_3$ concentration and the addition of hydrophobic solvents on the extraction efficiencies were investigated. Increases of the $NaNO_3$ concentration enhanced the extraction efficiencies of REE, and more than 95% recoveries were obtained at 5M of $NaNO_3$ concentration. On the other hand, addition of hydrophobic solvents lowered the extraction efficiencies. The method was applied to determine the REE in the monazite sample. But the precisions of the analytical results were more than 20%.

  • PDF

Rapid Simultaneous Determination of Anions in Mineral Water by Single Column Ion Chromatography (단일 컬럼이온크로마토그래피에 의한 광천수중 음이온의 신속한 동시정량)

  • Kim, Jong Hun;Choi, Yong Wook;Chung, Taek Kyun
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.910-917
    • /
    • 1995
  • Analytical conditions for single column ion chromatographic determination of five anions such as F-, Cl-, NO2-, NO3-, and SO42- were optimized with respect to analysis time and separation efficiency. At the optimum condition of 2.0 mM phthalic acid at pH 4.5, five anions were effectively separated in 10 minutes so that analysis time could be reduced by 40% compared to other recommended conditions. Under this condition all the calibration curves of five anions were linear with a correlation coefficient > 0.999. Analytical results for nine commercial bottled waters were presented.

  • PDF

Study on Isolative Determination Methylephedrine Hydrochloride and Ephedrine Hydrochloride in the Mixed Preparation (혼합제제중 Methylephedrine Hydrochloride와 Ephedrine Hydrochloride의 분리정량에 관한 연구)

  • Ko, In-Suk
    • Korean Journal of Pharmacognosy
    • /
    • v.1 no.3
    • /
    • pp.93-99
    • /
    • 1970
  • There have been reported by several workers for the isolation and determination of the amine derivatives as Metbylephedrine Hydrochloride and Ephedrine Hydrochloride adopting neutralization method, steam distillation method, non-aqous titration method, ion-exchange resin method, titration method after acetylation, colorimetric method, gravimetric method, iodine titration method and gas chromatography. Those methods mentioned in above, can be practically applied for the sample which is not mixed one mith the other amine compounds. Presently, it has not shown on the isolative determination of the mixed sample of amine derivatives. In this paper, it is discussed on the isolative determination of Methylephedrine Hydrochloride as the tertiary amine compound and Ephedrine Hydrochloride as the secondary amine compound. According to the results of the experiment, it could be summarized as follows: 1. There is no time-variation on the color reaction of Methylephedrine Hydrochloride and Ephedrine Hydrochloride with the color reagent, bromcresolgreen. And Methylephedrine Hydrochloride and Ephedrine Hydrochloride, respectively, can be determined spectrophotometrically by means oft his color reaction. 2. For the isolation of Methylephedrine Hydrochloride and Ephedrine Hydrochloride from the mixed sample, Methylephedrine Hydrochloride can be eluted by chloroform, while Ephedrine Hydrochloride by the mixed solvent of chloroform and ethylalcohol (2:1), from the celite column adsorbed at pH6.4 followed by extraction with ether undersodium hydroxide alkali re action. 3. When the sample is mixed with quinine hydrochloride, dihydrocodeine bitartate, and noscapine, these mixed compounds can be eliminated by means of stram distillation. 4. When the sample is mixed with chlorpheniramine maleate, dextromethorphan hydrobromide and diphenhydramine hydrochloride, the mixed compounds can be eliminated by means of steam distillation and celite adsorption column chromatography, In conclusion, the isolative determination method for Methylephedrine Hydrochloride and Ephedrine Hydrochloride studied in this paper, indicates with the excellent reproducibility and accuracy.

  • PDF

Investigation and Testing of Location Systems Using WiFi in Indoor Environments

  • Retscher, Guenther;Mok, Esmond
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.83-88
    • /
    • 2006
  • Many applications in the area of location-based services and personal navigation require nowadays the location determination of a user not only in outdoor environment but also indoor. To locate a person or object in a building, systems that use either infrared, ultrasonic or radio signals, and visible light for optical tracking have been developed. The use of WiFi for location determination has the advantage that no transmitters or receivers have to be installed in the building like in the case of infrared and ultrasonic based location systems. WiFi positioning technology adopts IEEE802.11x standard, by observing the radio signals from access points installed inside a building. These access points can be found nowadays in our daily environment, e.g. in many office buildings, public spaces and in urban areas. The principle of operation of location determination using WiFi signals is based on the measurement of the signal strengths to the surrounding available access points at a mobile terminal (e.g. PDA, notebook PC). An estimate of the location of the terminal is then obtained on the basis of these measurements and a signal propagation model inside the building. The signal propagation model can be obtained using simulations or with prior calibration measurements at known locations in an offline phase. The most common location determination approach is based on signal propagation patterns, namely WiFi fingerprinting. In this paper the underlying technology is briefly reviewed followed by an investigation of two WiFi positioning systems. Testing of the system is performed in two localization test beds, one at the Vienna University of Technology and the second at the Hong Kong Polytechnic University. First test showed that the trajectory of a moving user could be obtained with a standard deviation of about ${\pm}$ 3 m.

  • PDF

An Analysis of Age Estimation Cases Based on Teeth (치아에 의한 생체 연령감정 사례의 분석)

  • Jang, Hee-Young;Shin, Kyoung-Jin;Choi, Jong-Hoon;Kim, Chong-Youl
    • Journal of Oral Medicine and Pain
    • /
    • v.25 no.2
    • /
    • pp.253-263
    • /
    • 2000
  • We collected age determination cases which were done at Yonsei university dental hospital, department of oral medicine from 1976 to 1999 to analyze it's tendency among Koreans. We analyzed 435 clients cases which were stored by age estimation program from January 1993 to December 1999. The results are as follows: 1. There were no significant difference in the sexual distribution (male : 52.0%, female : 48.0%) and more than half percent (51%) were 20's and 30's. 2. Among the age determination clients, those who wanted to decrease their age (50.3%) and those who wanted to increase their age (49.7%) shows similar in number. And the former case were predominant in the female clients, but the latter case in the male clients. Also the clients below six years of age were predominant in the former case, but the clients more than sixty were predominant in the latter case. 3. The purposes of age correction showed different distribution for ages: job or employment for 20's and 30's, marriage for 20's, registration for school for below six, welfare and other social services for 50 and older. 4. Age was estimated by Nolla's growth stage for 12 and under, calcification of the second and third molar for 12~20, and for 20 and over, Takei's tooth abrasion model was used. 5. The alleged age was in accordance with the documents and other information given by clients, but in the 20.6% of the estimation cases, the alleged age was discarded. In the results of the analysis of age determination cases in Koreans, many of the cases resulted from our historical turbulence and social distinctiveness, causing an increase in the necessity for age correction in each age group. For more accurate determination for each age group, further studies with Koreans must be done continuously.

  • PDF

Simultaneous determination and acute toxicity study of Fructus mume extracts in ICR mice (오매(烏梅)의 다성분동시분석 및 마우스를 이용한 경구 단회투여 급성독성시험)

  • Lee, In-Sun;Han, Chang-Hyun;Lee, Chul;Hwang, Bang-Yeon;Jung, Sang-Hyeok;Lee, Young-Joon;Jeon, Won-Kyung
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.37-47
    • /
    • 2011
  • Objectives : Previous studies have shown that Fructus mume (FM) has anti-platelet effects. The present study was performed to determine the acute oral toxicity and quality control of a crude extract of FM in ICR mice. Methods : We investigated the in vivo single dose acute toxicity of FM 95% ethanol extract. This test was orally administered once by gavage to 20 male and 20 female mice at dose levels of 0 (control group), 1250, 2500 and 5000mg/kg body weight, respectively. Mortalities, clinical findings, autopsy findings and body weight changes were monitored daily for the 14 days following the administration. HPLC analysis was performed for the simultaneous determination of ursolic acid and p-hydroxycinnamic acid in FM. Reverse-phase chromatography using a C18 column and photodiode array detection at 211 nm was used for quantification of the two maker components. The mobile phase for gradient elution consists of water and acetonitrile. Results : We observed survival rates, general toxicity, change of body weight, and autopsy. The mice did not die after single oral administration of maximum dose of FM. Autopsy of animal revealed no abnormal gross finding. Therefore, $LD_{50}$ value of FM for ICR mice was more than 5000mg/kg on oral route. The HPLC analysis showed that ursolic acid and p-hydroxycinnamic acid amounts to 9.75- and 0.12% in the extract with the retention times of 47.99- and 15.38 minutes, respectively. Conclusions : These results suggest that no toxic dose level of FM in mice is considered to be more than 5000mg/kg. Consequently, it was concluded that FM have no effect on acute toxicity and side effect in ICR mice. For the quality control of FM extract, simultaneous determination of ursolic acid and p-hydroxycinnamic acid was established.