• 제목/요약/키워드: NO Emission Index

검색결과 65건 처리시간 0.022초

탄소고정방식을 활용한 농작물 이모작의 수익성 변화 (Changes in Profitability of a Double Cropping using the Carbon Fixation Method)

  • 모태준;김홍석
    • 농촌계획
    • /
    • 제26권2호
    • /
    • pp.61-70
    • /
    • 2020
  • The purpose of this study is to calculate the annual carbon reduction of crops according to the carbon fixation method of agricultural land, therefore to analyze whether the economic inducement of farmers to switch from single cropping to double cropping if the amount of carbon reduction were traded on the Korea Exchange. The analysis targets were Gyeonggi Province, which was divided into four areas to compare the difference between agricultural income and carbon income by crop and cropping system. Agricultural profit was estimated by multiplying the prior data of 2012 by the change rate of the consumer price index, and carbon income was calculated through the carbon reduction for each crop and the average transaction price of KAU19 traded on the Korea Exchange. According to the analysis, the profit rate of double cropping in all areas is -110.4% to 23% compared to single cropping, when only agricultural profit is taken into account, with no economic inducement for farmers to change the cropping system. However, when carbon income is taken into account together, the profit rate of double cropping rises significantly from 122.5% to 238.9% over a single operation in all areas, resulting in an economic inducement to switch the cropping system. This research is meaningful in that farming households could raise their income by additional carbon income, and that carbon credits could be supplied at Korea Exchange to further boost the carbon emission exchange.

TWO-COLOR VR CCD PHOTOMETRY OF OLD NOVA V603 AQUILAE

  • Andronov Ivan L.;Ostrova Nataliya I.;Kim, Yong-Gi;Burwitz V.
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권3호
    • /
    • pp.211-222
    • /
    • 2005
  • Results of 6 nights of CCD VR photometry of the nova-like variable V603 Aquilae (Nova Aquilae 1918) obtained at the Mallorcian 35-cm telescope in July 2004 are reported. The ephemeris for the superhump maximum is Max.HJD=2453213.60546(96)+0.14813(10)E. The waves with $3.^d9,\;1.^d4,\;0.^d135$ are statistically significant, which may be interpreted as the negative superhump-orbital, the beat periods (negative superhump- positive superhump) and the negative superhump with low amplitude, respectively. Another possible time-scale is $0.^d8,$ which has no coincidence with the beat periods. Quasi-periodic oscillations with an effective period of 18 minutes have been detected, which are close to 15.6 minutes reported by some authors. Their effective semi-amplitudes are $^m.045\;and\;0^m.051$ for V and R, respectively. This corresponds to the 0.12 mag excess in the color index V-R as compared with the mean color, which can be understood as the pulsed emission in the hotter inner parts of the accretion disk, similar to that observed in TT Ari and MV Lyr.

산소부화 조건인 CH4/CH3Cl/O2/N2 예혼합 화염에서 CH3Cl의 영향 (The Influence of CH3Cl on CH4/CH3Cl/O2/N2 Premixed Flames Under the O2 Enrichment)

  • 신성수;이기용
    • 대한기계학회논문집B
    • /
    • 제29권2호
    • /
    • pp.255-262
    • /
    • 2005
  • A comprehensive experimental and numerical study has been conducted to understand the influence of $CH_{3}Cl$ addition on $CH_4/O_2/N_2$ premixed flames under the oxygen enrichment. The laminar flame speeds of $CH_4/CH_{3}Cl/O_2/N_2$ premixed flames at room temperature and atmospheric pressure are experimentally measured using Bunsen nozzle flame technique, varying the amount of $CH_{3}Cl$ in the fuel, the equivalence ratio of the unburned mixture, and the level of the oxygen enrichment. The flame speeds predicted by a detailed chemical kinetic mechanism employed are found to be in excellent agreement with those deduced from experiments. Even though the molar amount of $CH_{3}Cl$ in a methane flame is increased, temperature at the postflame is not significantly varied, but the calculated heat release rate and emission index of NO are largely decreased for the oxygen enhanced flame. The function of $CH_{3}Cl$ as inhibitor on hydrocarbon flames becomes weakened as the level of the oxygen enrichment is increased from 0.21 to 0.5.

Eclipse Spectrum of Her X-1 Observed by ASCA in the Low Intensity State

  • Choi, C.S.;Seon, K.I.
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1995년도 한국우주과학회보 제4권2호
    • /
    • pp.30-30
    • /
    • 1995
  • We present the results of analysis on the X-ray observations of the binary X-ray pulsar Her X-I. made with ASCA/SIS on August 13-14. 1993. An eclipse transition from ingress to egress was fully covered by the observations. The main findings are as follows; (1) a model of power-law plus black-body is required to interpret the entire eclipse spectrum. and the black-body component appears at < 0.7 keV. (2) the power-law continuum which has photon index ${\alpha}\;=\;{0.84^{\;+0.14}}_{\;-0.19}$ is very similar to that of detected by Ginga/LAC (${\alpha}\;=\;0.80\;{\pm}\;0.04$), (3) the calculated eclipse flux of $2^{-10}\;keV.{\;}~{\;}1.8{\pm}10^{-11}{\;}ergs{\;}cm^{-2}s^{-1}$, is consistent with the Ginga observation carried out in the high intensity state ~2.0{\pm}10^{-11}{\;}ergs{\;}cm^{-2}s^{-1}$, (4) there is no significant absorption feature. and an upper limit of the aborption column $NH{\;}\leq{\;}3{\pm}10^{20}\;cm^{-2}$ is determined at the 90% confidence limit. Based on these results, we suggest that extended matter surrounding the binary system should be existed persistently with stable conditions, and scattering of the source continuum by the matter is responsible for the eclipse emission.ission.

  • PDF

선미의 불균일 유동장에서 받음각을 고려한 비대칭 전류고정날개 설계 (Design of Asymmetric Pre-swirl Stator for KVLCC2 Considering Angle of Attack in Non-uniform Flow Fields of the Stern)

  • 이기승;김문찬;신용진;강진구
    • 대한조선학회논문집
    • /
    • 제56권4호
    • /
    • pp.352-360
    • /
    • 2019
  • International Maritime Organization (IMO) regulates an emission of greenhouse gases by creating an Energy Efficiency Design Index (EEDI) to reduce environmental pollution. In propulsion system field, studies are under way on Energy Saving Device (ESD), which can improve propulsion efficiency with the propeller, to reduce the EEDI. Among the studies, the study of Pre-Swirl Stator (PSS) has been actively conducted from long time ago. Recently the variable pith angle type pre-swirl stator has been studied to improve the propulsion efficiency in non-uniform flow fields of the Stern. However, for traditional design methods, no specific design method has been established on the blade or location of radius. In this study, proper design method is proposed for each blade or location for radius according to hydrodynamic pitch angle.

Value of Bone Scintigraphy and Single Photon Emission Computed Tomography (SPECT) in Lumbar Facet Disease and Prediction of Short-term Outcome of Ultrasound Guided Medial Branch Block with Bone SPECT

  • Koh, Won-Uk;Kim, Sung-Hoon;Hwang, Bo-Young;Choi, Woo-Jong;Song, Jun-Gul;Suh, Jeong-Hun;Leem, Jeong-Gill;Shin, Jin-Woo
    • The Korean Journal of Pain
    • /
    • 제24권2호
    • /
    • pp.81-86
    • /
    • 2011
  • Background: Facet joint disease plays a major role in axial low-back pain. Few diagnostic tests and imaging methods for identifying this condition exist. Single photon emission computed tomography (SPECT) is reported that it has a high sensitivity and specificity in diagnosing facet disease. We prospectively evaluated the use of bone scintigraphy with SPECT for the identification of patients with low back pain who would benefit from medial branch block. Methods: SPECT was performed on 33 patients clinically suspected of facet joint disease. After SPECT, an ultrasound guided medial branch block was performed on all patients. On 28 SPECT-positive patients, medial branch block was performed based on the SPECT findings. On 5 negative patients, medial branch block was performed based on clinical findings. For one month, we evaluated the patients using the visual analogue scale (VAS) and Oswestry disability index. SigmaStat and paired t-tests were used to analyze patient data and compare results. Results: Of the 33 patients, the ones who showed more than 50% reduction in VAS score were assigned 'responders'. SPECT positive patients showed a better response to medial branch blocks than negative patients, but no changes in the Oswestry disability index were seen. Conclusions: SPECT is a sensitive tool for the identification of facet joint disease and predicting the response to medial branch block.

UV 기반 백색 LED용 청색 형광체의 발광특성 및 백색 LED 제조 (Luminescence Characteristics of Blue Phosphor and Fabrication of a UV-based White LED)

  • 정형식;박성우;김태훈;김종수
    • 한국광학회지
    • /
    • 제25권4호
    • /
    • pp.216-220
    • /
    • 2014
  • UV용 청색 형광체 $CaMgSi_2O_6:Eu^{2+}$를 환원 분위기 속에서 고상반응법(Solid-state reaction)으로 합성하였다. 합성된 형광체의 결정성을 확인하기 위해 X-선 회절(X-ray diffraction) 패턴 측정결과 C2/c(15)의 공간군과 단사정계(Monoclinic) 구조를 가지는 JCPDS No.75-1092와 일치하는 단일상임을 확인하였다. 광 여기 및 발광 스펙트럼을 통하여 350 nm 부근에서 최대 흡수치가 나타나며, 450 nm의 청색 발광을 보인다. 이는 $Eu^{2+}$이온의 $4f^7-4f^65d$의 천이에 기인한다. 온도에 따른 형광체의 발광 스펙트럼을 확인한 결과 $100^{\circ}C$에서 54%의 휘도 유지율을 보였다. 상기 합성된 $CaMgSi_2O_6:Eu^{2+}$와 400 nm의 Ultra Violet 발광 다이오드를 이용하여 상용 녹색, 적색 형광체와 혼합하여 백색 LED를 구현 하였다. 구현된 백색 LED는 구동 전류 350 mA, 구동 전압 3.45 V에서 색좌표 x=0.3936, y=0.3605, 색온도(CCT) 3500 K, 연색성(CRI) 87, 발광 효율 18 lm/w로 나왔다. 또한 400시간 기준 수명 시험 결과 초기광도 대비 97%의 유지율을 보였다. 따라서 본 연구를 통해 합성한 청색 형광체 $CaMgSi_2O_6:Eu^{2+}$는 UV LED기반의 백색 조명용 형광체로서의 가치가 있는 것으로 생각된다.

$^{99m}Tc$-HMPAO SPECT를 이용한 알쯔하이머병의 진단에서 허혈성 뇌병변이 미치는 영향 (Influence of Ischemic Lesions on $^{99m}Tc$-HMPAO SPECT Findings in the Diagnosis of Alzheimer's Disease)

  • 이경한;이명철;이동수;권준수;김종호;정준기;우종인;고창순
    • 대한핵의학회지
    • /
    • 제28권3호
    • /
    • pp.282-292
    • /
    • 1994
  • 본 연구에서는 $^{99m}Tc$-HMPAO SPECT를 이용한 AD의 진단에서 허혈성 뇌병변의 유무와 대조군의 선정방법이 진단성적에 미치는 영향을 조사하기 위하여 지역주민을 대상으로 진단된 PAD군 11례와 연령을 맞춘 대조군 12례에서 SPECT를 시행하여 국소 혈류비를 분석하였다. MRI 소견을 조사한 결과 PAD군의 27%(3/11)와 대조군의 25%(3/12)에 유의한 뇌허혈 또는 경색 병변이 관찰되었다. 뇌병변의 유무와 관계없이 두군을 비교한 결과 측두엽이나 두정엽에 평균혈류비의 유의한 차이가 없었으며 두군을 신뢰성있게 감별할 만한 특징적인 혈류양상을 발견하지 못하였다. 그러나 뇌허혈병변이 있는 자를 대조군에서 제외시켰을 때 두군의 측두엽 및 두정엽 혈류비의 차이가 증가하였다. 또 별도로 설정한 건강한 대조군과 비교한 결과 같은 부위의 혈류비에 현저한 차이가 관찰되었다. 이상의 결과로 뇌혈류 SPECT에 의한 AD의 진단성적은 연구대상의 선정에 의해 영향을 받으며 특히 허혈성 뇌병변의 유무는 연구결과에 많은 영향을 미친다고 생각되었다. 향후 허혈성 뇌병변에 의한 영향을 해결하기 위해 SPECT 영상을 방사선학적 검사와 함께 평가하는 방법에 대한 연구가 필요하다고 사료되었다.

  • PDF

다양한 환경요인과 난분해성 유기물에 따른 고온산화 및 UV산화방식 총 유기탄소 산화율 변화 (Influences of Environmental Conditions and Refractory Organic Matters on Organic Carbon Oxidation Rates Measured by a High Temperature Combustion and a UV-sulfate Methods)

  • 정헌재;이보미;이근헌;신현상;허진
    • 한국물환경학회지
    • /
    • 제32권1호
    • /
    • pp.98-107
    • /
    • 2016
  • This study examined the effects of environmental conditions and the presence of refractory organic matter on oxidation rates of total organic carbon (TOC) measurements based on high temperature combustion and ultraviolet-sulfate methods. Spectroscopic indices for prediction of oxidation rates were also explored using the UV spectra and fluorescence excitation-emission matrix (EEM) of humic acids. Furthermore, optimum TOC instrument conditions were suggested by comparing oxidation rates of a standard TOC material under various conditions. Environmental conditions included salts, reduced ions, and suspended solids. Salts had the greatest influence on oxidation rates in the UV-sulfate method. However, no effect was detected in the high temperature combustion method. The UV-sulfate method showed lower humic substance oxidation rates, refractory natural organic matter, compared to the other methods. TOC oxidation rates for the UV-sulfate method were negatively correlated with higher specific-UV absorbance, humification index, and humic-like EEM peak intensities, suggesting that these spectroscopic indices could be used to predict TOC oxidation rates. TOC signals from instruments using the UV-sulfate method increased with increasing chamber temperature and increasing UV exposure durations. Signals were more sensitive to the former condition, suggesting that chamber temperature is important for improving the TOC oxidation rates of refractory organic matter.

Pelvic insufficiency fracture after radiotherapy in patients with cervical cancer in the era of PET/CT

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong-Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • 제29권4호
    • /
    • pp.269-276
    • /
    • 2011
  • Purpose: To determine the incidence, risk factors, and clinical characteristics of pelvic insufficiency fracture (PIF) in patients with cervical cancer. Materials and Methods: Between July 2004 and August 2009, 235 patients with non-metastatic cervical cancer were treated with definitive chemoradiation or postoperative radiotherapy. Among 235 patients, 117 (49.8%) underwent the first positron emission tomography/computed tomography (PET/CT) within 1 year after radiotherapy. The median radiation dose was 55 Gy (range, 45 to 60 Gy). Medical charts and imaging studies, including PET/CT, magnetic resonance imaging (MRI), CT. bone scintigraphy were reviewed to evaluate the patients with PIF. Results: Among 235 patients, 16 developed PIF. The 5-year detection rate of PIF was 9.5%. The 5-year detection rate of PIF in patients who underwent the first PET/CT within a year was 15.6%. The median time to development of PIF was 12.5 months (range, 5 to 30 months). The sites of fracture included 12 sacroiliac joints, 3 pubic rami, 3 iliac bones, and 1 femoral neck. Eleven of 16 patients having PIF complained of hip pain requiring medications. One patient required hospitalization for pain control. The significant risk factors of PIF were old age, body mass index less than 23, bone mineral density less than -3.5 SD, and the first PET/CT within a year after radiotherapy. Radiation dose and concurrent chemotherapy had no impact on PIF rate. Conclusion: PIFs were not rare after pelvic radiotherapy in cervical cancer patients in the era of PET/CT. Timely diagnosis and management of PIF can improve quality of life in patients with cervical cancer, in addition to reducing unnecessary medical expenses.