• 제목/요약/키워드: NIR laser

검색결과 33건 처리시간 0.023초

Low Cost Omnidirectional 2D Distance Sensor for Indoor Floor Mapping Applications

  • Kim, Joon Ha;Lee, Jun Ho
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.298-305
    • /
    • 2021
  • Modern distance sensing methods employ various measurement principles, including triangulation, time-of-flight, confocal, interferometric and frequency comb. Among them, the triangulation method, with a laser light source and an image sensor, is widely used in low-cost applications. We developed an omnidirectional two-dimensional (2D) distance sensor based on the triangulation principle for indoor floor mapping applications. The sensor has a range of 150-1500 mm with a relative resolution better than 4% over the range and 1% at 1 meter distance. It rotationally scans a compact one-dimensional (1D) distance sensor, composed of a near infrared (NIR) laser diode, a folding mirror, an imaging lens, and an image detector. We designed the sensor layout and configuration to satisfy the required measurement range and resolution, selecting easily available components in a special effort to reduce cost. We built a prototype and tested it with seven representative indoor wall specimens (white wallpaper, gray wallpaper, black wallpaper, furniture wood, black leather, brown leather, and white plastic) in a typical indoor illuminated condition, 200 lux, on a floor under ceiling mounted fluorescent lamps. We confirmed the proposed sensor provided reliable distance reading of all the specimens over the required measurement range (150-1500 mm) with a measurement resolution of 4% overall and 1% at 1 meter, regardless of illumination conditions.

Feasibility Study for the Monitoring of Urea in Dialysate Solution using Raman Spectroscopy

  • Kim, Jae-Jin;Hwang, Jin-Young;Kim, Yong-Dan;Chung, Ho-Eil
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.805-808
    • /
    • 2011
  • We have determined the urea concentration in an aqueous solution using Raman spectroscopy by incorporating a Teflon tube as an effective intensity correction standard as well as sample container. A non-overlapping Teflon band was used as the reference peak to correct Raman intensity variations that occasionally resulted from changes in laser power. To increase the sensitivity, we positioned a copper reflector inside the Teflon tube to maximize the collection of Raman scattering. The obtained accuracy using Raman spectroscopy was 0.53 mM, close to the range of accuracy of previous NIR studies (0.15-0.52 mM).

단일벽 탄소나노튜브의 분산도 정량적 평가 (The Quantitative Characterization of the Dispersion State of Single-Walled Carbon Nanotubes)

  • 윤도경;최재붕;김영진;백승현
    • 대한기계학회논문집A
    • /
    • 제31권4호
    • /
    • pp.483-489
    • /
    • 2007
  • We have investigated quantitative measurement techniques of the degree of dispersion of single-walled carbon nanotubes (SWNTs). SWNTs were suspended in aqueous media using a sodium dodecyl sulfate (SDS) surfactant. SWNTs with different dispersion states were prepared by controlling the intensity and time of sonication and centrifugation. The laser spectroscopic techniques were employed to characterize the dispersion state; i.e., raman fluorescence and absorption spectroscopic techniques. Raman spectroscopy has been used to probe the dispersion and aggregation state of SWNTs in solution. Individually suspended SWNTs show increased fluorescence peaks and decreased roping peaks at a raman shift 267 $cm^{-1}$ compared with the samples containing bundles of SWNTs. The ultraviolet-visible-near infrared (UV-vis-NIR) absorption spectrum of decanted supernatant samples show sharp van Hove singularity peaks

다공성 티타늄 임플란트의 생리활성물질 담지특성에 관한 연구 (A study of loading property of the bioactive materials in porous Ti implants)

  • 김영훈
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.281-286
    • /
    • 2013
  • Purpose: Surface modification is important techniques in modern dental and orthopedic implants. This study was performed to try embedding of bioactive materials in porous Ti implants. Methods: Porous Ti implant samples were fabricated by sintering of spherical Ti powders in a high vacuum furnace. It's diameter and height were 4mm and 20mm. Embedding process was used to suction and vacuum chamber. Loading properties of porous Ti implants were evaluated by scanning electron microscope(SEM), confocal laser scanning microscope(CLSM), and UV-Vis-NIR spectrophotometer. Results: Internal pore structure was formed fully open pore. Average pore size and porosity were $10.253{\mu}m$ and 17.506%. Conclusion: Porous Ti implant was fabricated successfully by sintering method. Particles are necking strongly each other and others portions were vacancy. This porous structure can be embedded to bioactive materials. Therefore bioactive materials will be able to embedding to porous Ti implants. Bioactive materials embedding in the porous Ti implant will induced new bone faster.

ANTIOXIDATIVE ACTIVITIES OF SOME DIETARY FIBERS DETERMINED BY AN NIR EMISSION SPECTROSCOPY

  • Suzuki, Nobutaka;Nagai, Takeshi;Tokunou, Kazunari;Mizumoto, Iwao;Matsuya, Hiroko;Yoda, Binkoh;Itami, Toshiaki;Takahashi, Yukinori;Kozawa, Akiya
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3102-3102
    • /
    • 2001
  • Constituents of several .representative seaweeds, such as wakame Undaria pinnatifida; hijikia Hizikia fusifome; and kombu Laminaria japonica, were found to have fairly large reaction rates determined by quenching experiments of emission spectra in the near-infrared region (1max: 1270 nm) from singlet oxygen (102). Emission spectra of singlet oxygen generated from an aqueous solution of Rose Bengal under irradiation with a green laser (330 nm) were measured by a near-infrared (NIR) emission spectrometer constructed in our laboratory. The quenching experiments were as follows: Intensities of emission spectra were measured in the absence (I0) and in the presence of the seaweed constituents (I): Ratios of I0/I were plotted against every concentration of the quenchers (Stern-Volmer plots) which gives a straight line. The slope of each line gives a kqt value which gives a quenching constant kq value (an antioxidative constant against singlet oxygen) when the t value (half-life time of singlet oxygen in the solvent used) was given. The determined reaction rates are between 103-105 (g/l)-ls-1; the larger ones are as large as that of ascorbic acid, 8.4 ${\times}$ 104 (g/1)-ls-1. Most of these seaweed constituents also showed antioxidative activity against auto-oxidation and superoxide as well as their immunological enhancing activity. These results suggest a possibility that dietary fibers which are supposed to prevent the large-intestine cancer by their physical properties may prevent the cancer, at least in parts, by their chemical, antioxidative activity.

  • PDF

TeOx(22 1차원 광자결정의 광학 특성평가 (Optical Properties of TeOx(2x One-dimensional Photonic Crystals)

  • 공헌;여종빈;이현용
    • 한국전기전자재료학회논문지
    • /
    • 제27권12호
    • /
    • pp.831-836
    • /
    • 2014
  • One-dimensional (1D) photonic crystals (PCs) were prepared by $TeO_x(2<x<3)/SiO_2$ with the difference refractive index, and fabricated by sputtering technique from a $TeO_2$ and $SiO_2$ target. The $TeO_x$(2$Ar:O_2=40:10$). A 10-pair $TeO_x(2<x<3)/SiO_2$ 1D PCs were fabricated with the structure parameters of filling factor=0.5185, and period=410 nm. The properties of 1D PCs with and without a defect layer were evaluated by UV-VIS-NIR. A normal mode 1D PC have a photonic band gap (PBG) in the near infrared (NIR) region from 1,203 to 1,421 nm. In the case of 1D PC containing a defect layer, a defect level appears at 1,291 nm. The measured transmittance (T) spectra are nearly corresponding to calculated results. After He-Cd laser exposure, the defect level is shifted from 1,291 nm to 1,304 nm.

LIBS 분광기를 이용한 폐소형가전 플라스틱 패턴 분류기의 설계 (Design of Pattern Classifier for Electrical and Electronic Waste Plastic Devices Using LIBS Spectrometer)

  • 박상범;배종수;오성권;김현기
    • 한국지능시스템학회논문지
    • /
    • 제26권6호
    • /
    • pp.477-484
    • /
    • 2016
  • 선풍기, 오디오, 전기밥솥 등의 소형 산업가전제품들은 대부분 ABS, PP, PS 등의 재질로 이루어져 있다. 색깔이 있는 플라스틱은 근적외선(NIR) 분광기에 의해 분류가 가능하지만, 반면에 검은색 플라스틱은 빛을 흡수하는 특성으로 인해 분류하기가 어렵다. 그래서 본 연구에서는 LIBS(Laser Induced Breakdown Spectroscopy) 분광기를 통해 폐소형가전 플라스틱을 선별하는 RBFNNs(Radial Basis Function Neural Networks) 패턴 분류기를 소개한다. 전처리부분에는 차원축소 알고리즘 중 하나인 PCA(Principal Component Analysis)를 사용해 처리 속도를 향상시킬 뿐만 아니라 효과적인 데이터의 특성을 추출한다. 조건부에는 FCM(Fuzzy C-Means) 클러스터링을 사용한다. 결론부에는 다항식의 형태 중 하나인 1차 선형식을 연결가중치로서 사용한다. PSO와 5-fold cross validation은 성능의 신뢰도를 향상시키고, 분류율을 높이는데 사용된다. 제안된 분류기의 성능은 최적화한 것과 최적화하지 않은 것 두 가지의 관점에서 보여준다.

LIBS를 이용한 흑색 플라스틱의 자동선별 시스템 개발 (Development of Automatic Sorting System for Black Plastics Using Laser Induced Breakdown Spectroscopy (LIBS))

  • 박은규;정밤빛;최우진;오성권
    • 자원리싸이클링
    • /
    • 제26권6호
    • /
    • pp.73-83
    • /
    • 2017
  • 소형가전 제품은 종류가 다양할 뿐만 아니라 구성부품의 재질도 복잡하여 폐기시 재활용이 매우 어려운 실정이다. 특히, 폐소형가전의 경우 흑색 플라스틱의 함유량이 높을 뿐만 아니라 재질이 다양하여 재활용 공정에서 발생하는 플라스틱의 재질을 인식하여 효율적으로 선별 회수하는 것이 매우 어렵다. 본 연구에서는 기존 선별기술이 가지고 있는 흑색 플라스틱의 재질별 선별에 대한 기술적 한계 및 단점을 보완하기 위하여 레이저유도붕괴분광법(Laser-Induced Breakdown Spectroscopy, LIBS)을 기반으로 하는 흑색 플라스틱의 재질별 자동선별 시스템을 개발하였다. 본 시스템은 정량 공급장치, 위치 자동인식 장치, 레이저유도기반분광분석(LIBS) 장치, 선별분리장치 및 Control unit 등으로 구성되어 있다. 레이저유도붕괴분광법(LIBS)을 이용하여 흑색 플라스틱의 재질별 특성 스펙트럼 데이터를 획득하고, 인공지능형 알고리즘을 적용한 분류기를 설계하여 적용함으로써 흑색 플라스틱의 재질을 효율적으로 인식하고 분류할 수 있다. 본 연구에서 개발한 방사형기저함수신경회로망(RBFNNs) 분류기의 분류율은 약 97% 이상으로 나타났으며, 자동선별 시스템의 흑색 플라스틱의 재질별 인식률은 약 94.0% 이상, 선별효율은 80.0% 이상으로 조사되었다. 본 연구에서는 실험실 규모의 자동선별장치를 개발하였으며, 본 장치에 대한 실험결과를 바탕으로 흑색 플라스틱 재질인식 및 선별효율 등을 분석하므로써 향후 폐소형가전의 재활용 현장에 적용할 예정이다.

Synthesis and Characterization of Peripherally Ferrocene-modified Zinc Phthalocyanine for Dye-sensitized Solar Cell

  • An, Min-Shi;Kim, Soon-Wha;Hong, Jong-Dal
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3272-3278
    • /
    • 2010
  • Synthesis and structural characterization of peripherally ferrocene-substituted zinc phthalocyanine (ZnPc-Fc) were carried out for efficient far-red/near-IR performance in dye-sensitized nanostructured $TiO_2$ solar cells. Incorporating ferrocene into phthalocyanine strongly improved the dye solubility in polar organic solvents, and reduced surface aggregation due to the steric effect of bulky ferrocene substituents. The involvement of electron transfer reaction pathways between ferrocene and phthalocyanine in ZnPc-Fc was evidenced by completely quenched fluorescence from S1 state (< 0.08% vs ZnPc). Strong absorption bands at 542 and 682 nm were observed in the transient absorption spectroscopy of ZnPc-Fc in DMSO, which was excited at a 670 nm laser pulse with a 15 ps full width at half maximum. Also, the excited state absorption signals at 450 - 600 and 750 - 850 nm appeared from the formation of charge separated state of phthalocyanine's anion. The lifetime of the charge separate state in ZnPc-Fc was determined to be $170{\pm}8$ ps, which was almost 17 times shorter than that of the ZnPc.

2 파장 라만 산란을 이용한 비침습적 HbA1c 측정 (Non-Invasive HbA1c Measurement Using Two-Wavelength Raman Scattering)

  • 양주란;김형표
    • 센서학회지
    • /
    • 제28권5호
    • /
    • pp.305-310
    • /
    • 2019
  • The purpose of this study is to classify the concentration of HbA1c (glycosylated hemoglobin), which is an indicator in the management of accurate blood glucose level in diabetic patients, using a non-invasive optical property measurement method. To measure the optical properties of HbA1c, the optical source uses LEDs and laser diodes of 400 nm in the visible region and 1450 nm in the nearinfrared region using thermopile to detect the Raman scattering intensity. An HbA1c control solution was used. As a result, the optical properties of 5% (normal) and 9% (abnormal) HbA1c control solutions showed specificity in which the output values were reversed at 850 nm and 950 nm, respectively. This property was applied to distinguish between normal and abnormal values in diabetes. In addition, considering tissue penetration depths for non-invasive measurements, two wavelengths were determined to be effective in distinguishing the concentrations of HbA1c control solutions at 5%, 7%, and 9%.