• Title/Summary/Keyword: NIR analysis

Search Result 390, Processing Time 0.027 seconds

PREDICTION OF BEEF TENDERNESS USING NEAR-INFRARED REFLECTANCE SPECTRUM ANALYSIS

  • Cho, S.I.;Yeo, W.Y.;Nam, K.C.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11c
    • /
    • pp.521-524
    • /
    • 2000
  • Nearinfra-red(NIR) reflectance NIR a spectra (400 to 2,100 nm) were collected on 32 beef samples to find feasibility of predicting beef tenderness. The study to predict beef tenderness was accomplished with the stepwise second differential data of the collected NIR spectra. Beef tenderness was measured by Warner-Bratzler(WB) shear force using a Universal Testing Machine(UTM). After modeling the relation between Warner-Bratzler shear force and NIR spectrum of 19 samples among the 32 beef samples, the verification was carried out through predicting the other 13 samples. The SEC and R$^2$ values in the prediction equation were 9.07(N) and 0.6463, respectively. The SEP and R$^2$ were 14.8(N) and 0.7082 (wave length 552 nm, 1988 nm) respectively. The result implied that it was possible to predict the beef tenderness using NIR spectrum and that the tenderness could be predicted non-destructively in real time.

  • PDF

Determination of Hydrogen Peroxide Concentration by Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 과산화수소의 농도 측정)

  • 임현량;우영아;장수현;김경미;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.5
    • /
    • pp.324-330
    • /
    • 2002
  • This experiment was carried out to determine non-destructively the hydrogen peroxide concentration of 3% antiseptic hydrogen peroxide solutions by portable near-infrared (NIR) system. Hydrogen peroxide standards were prepared ranging from 0 to 25.6 w/w% and the NIR spectra of hydrogen peroxide standard solutions were collected by using a quartz cell in 1 mm pathlength. We found the variation of absorbance band due to OH vibration of hydrogen peroxide depending on the concentration around 1400 nm in the second derivatives spectra. Partial least square regression (PLSR) and multilinear regression (MLR) were explored to develop a calibration model over the spectral range 1100-1720 nm. The model using PLSR was better than that using MLR. The calibration showed good results with a standard error of prediction (SEP) of 0.16%. In order to validate the developed calibration model, routine analyses were performed using commercial antiseptic hydrogen peroxide solutions. The hydrogen peroxide values from the NIR calibration model were compared with the values from a redox titration method. The NIR routine analyses results showed good correlation with those of the redox titration method. This study showed that the rapid and non-destructive determination of hydrogen peroxide in the antiseptic solution was successfully performed by portable NIR system without very harmful solvents.

A study on the use of FT-NIR spectophotometer for dried laver quality evaluation (마른김 품질 평가를 위한 FT-NIR 분광기 활용 연구)

  • Kyoung-In, Lee;Geun-Jik, Lee;Young-Seung, Yoon
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.14 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • The micro-Kjeldahl method, a common technique for analyzing crude proteins, is time-consuming and dangerous due to the employment of reagents such as sulfuric acid and sodium hydroxide. However, a Fourier transform near-infrared (FT-NIR) spectrophotometer analysis can be completed in under a minute after simple pre-processing if data has been gathered using sufficient reference material in advance. Furthermore, the use of safe reagents in this technique ensures the safety of the experimenter and the environment. In addition, a portable FT-NIR spectrophotometer enables real-time measurement at processing or distribution sites and has recently gained popularity. The standard errors of calibration and regression (r2) for the calibration result for estimating the crude protein content of dried laver were 0.9775 and 1.2526, respectively. The standard error of prediction was 1.1814, and the r2 was 0.9303 in the validation results, which was a good level. In the present study, a method for predicting the crude protein content of dried laver using an FT-NIR spectrophotometer in the range of 29%-40% crude protein content has been reported.

Landuse Analysis by NIR Spectral data (NIR 방사자료에 의한 피복분석 연구)

  • Kim, Dong-Moon
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.404-407
    • /
    • 2011
  • 도시공간은 도시민의 안정적인 경제/문화/기타 활동 유지를 위해 개발 및 관리되어진다. 최근 도시공간 내에 존재하는 다양한 형태의 구조물에 대한 안전에 많은 관심이 쏠리고 있는 상황에서 이러한 도시 구조물에 대한 신속 정확한 형태학적 특성 분석이 요구되고 있다. 그러나 이러한 도시 구조물에 대한 모니터링에 대한 관심에 못지 않게 주변의 다양한 식생이나 피복에 대한 분석에 대한 요구가 증가하고 있다. 따라서 이 연구에서는 도시공간내 존재하는 다양한 식생의 피복을 분석하기 위해 NIR 방사 자료를 활용하는 기초적 연구를 통해 근적외선 방사자료를 통한 피복분석을 효과적으로 실시하였다.

  • PDF

Algorithm for finding the best regression models using NIR spectra

  • Cho, Jung-Hwan;Huh, Yun-Jung;Park, Young-Joo
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.402.2-402.2
    • /
    • 2002
  • An algorithm for finding the best regression models has been developed using NIR spectral data. In cases of regression analysis for quantitation with NIR spectral data, it is very critical to find essential features from the spectral data. This task was accessed in two ways. The first one was to use all-possible combinations of varibles (wavelengths). Correlation coefficients at each spectral points were calculated to get initial set of variables and all of the possible combinations of variable sets were tested with SEC. SEP and/or $R^2$. (omitted)

  • PDF

Prediction on the Quality of Total Mixed Ration for Dairy Cows by Near Infrared Reflectance Spectroscopy (근적외선 분광법에 의한 국내 축우용 TMR의 성분추정)

  • Ki, Kwang-Seok;Kim, Sang-Bum;Lee, Hyun-June;Yang, Seung-Hak;Lee, Jae-Sik;Jin, Ze-Lin;Kim, Hyeon-Shup;Jeo, Joon-Mo;Koo, Jae-Yeon;Cho, Jong-Ku
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.29 no.3
    • /
    • pp.253-262
    • /
    • 2009
  • The present study was conducted to develop a rapid and accurate method of evaluating chemical composition of total mixed ration (TMR) for dairy cows using near infrared reflectance spectroscopy (NIRS). A total of 253 TMR samples were collected from TMR manufacturers and dairy farms in Korea. Prior to NIR analysis, TMR samples were dried at $65^{\circ}C$ for 48 hour and then ground to 2 mm size. The samples were scanned at 2 nm interval over the wavelength range of 400-2500 nm on a FOSS-NIR Systems Model 6500. The values obtained by NIR analysis and conventional chemical methods were compared. Generally, the relationship between chemical analysis and NIR analysis was linear: $R^2$ and standard error of calibration (SEC) were 0.701 (SEC 0.407), 0.965 (SEC 0.315), 0.796 (SEC 0.406), 0.889 (SEC 0.987), 0.894 (SEC 0.311), 0.933 (SEC 0.885) and 0.889 (SEC 1.490) for moisture, crude protein, ether extract, crude fiber, crude ash, acid detergent fiber (ADF) and neutral detergent fiber (NDF), respectively. In addition, the standard error of prediction (SEP) value was 0.371, 0.290, 0.321, 0.380, 0.960, 0.859 and 1.446 for moisture, crude protein, ether extract, crude fiber, crude ash, ADF and NDF, respectively. The results of the present study showed that the NIR analysis for unknown TMR samples would be relatively accurate. Use of the developed NIR calibration curve can obtain fast and reliable data on chemical composition of TMR. Collection and analysis of more TMR samples will increase accuracy and precision of NIR analysis to TMR.

IDENTIFICATION OF GEOGRAPHICAL ORIGIN AND VARIETY OF GREEN COFFEE BY NIR

  • Nzabonimpa, Rukundo;Prodolliet, Jacques;Vouilloz, Annick
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1151-1151
    • /
    • 2001
  • The international coffee trade is conducted almost exclusively with green coffee. The main coffee producing countries include Brazil, Columbia, Indonesia, Mexico and the Ivory Coast. About 99 % of the coffee grown throughout the world belong to two coffee plant varieties that are commonly known as Arabica and Robusta. The quality of green coffee can be assessed according to several ISO standards (1,2,3,4,5). However, no official international standards for the authenticity of green coffee have been issued. It is important to know the country of origin of the coffee for the purposes of fair international trade. The geographic origin of the coffee is often stated on the label of coffee products such as speciality roasted and soluble coffees. Near Infrared Spectroscopy (NIR) is an accepted technique for quantitative analysis of various parameters in routine QC analysis of food products. It would appear to be a promising candidate as a tool for identification of green coffee origin and numerous feasibility studies have appeared in the literature on its use for soluble, roasted and green coffee variety identification as well as identification of arabica or robusta coffees. NIR spectrophotometers when configured in the reflectance mode are able to perform a complete profile of the NIR spectrum on whole beans. The data can then be interpreted by discriminant chemometrics data analysis. This is the approach used in the present study.

  • PDF

Unambiguous Evidence for Phase Transitions of Oleic Acid in Pure Liquid State by Near-Infrared Spectroscopy and Pricipan Comaonent Analysis

  • Nobuya Yokochi;Makio Iwahashi;Masao Suzuki;Yukihiro Ozaki
    • Near Infrared Analysis
    • /
    • v.1 no.2
    • /
    • pp.21-27
    • /
    • 2000
  • Temperature-dependent changes in near-infrared (NIR) spectra have been measured for oleic acid, and nonanoic acid in the pure liquid state. Particular attention has been paid to the 5400-4800 cm$\^$-1/ region where a number of combination bands appear. The NIR spectra of oleic acid show that a band at 5303 cm$\^$-1/ increases with temperature while that at 5270 cm/sup-1/ decreases. It ha been found from their second derivative spectra that these spectral changes take place stepwisely with two break points at 30 and 53$\^{C}$, which correspond to the phase transition temperatures oleic acid reported previously. Principle component analysis (PCA) has been carried out for the NIR spectra of oleic acid in the 5400-4800 cm$\^$-1/ region measured over a temperature range of 15-80$\^{C}$. core plots of the first and second principal components (PCs) show that the NIR spectra are classified into three groups; the spectra measured in the temperature range of 15-30$\^{C}$, those in the range of 31-53$\^{C}$, and those in the range of 54-80$\^{C}$. These temperature ranges correspond to those for quasi-smectic liquid crystal, disordered liquid crystal, and isotropic liquid of oleic acid in the pure liquid state. In other words, PCA provides unambiguous evidence for the phase transitions. similar studies have been carried out for petroselinic acid and nonanoic acid in the pure liquid states, but they do not show any evidence for phase transitions.

Measurement of Deproteinization and Deacetylation of Chitin and Chitosan by Near Infrared Spectroscopy (근적외선 분광분석법을 이용한 Chitin 및 Chitosan의 탈단백 및 탈아세틸화도 측정)

  • SONG Ho-Su;LEE Keun-Tai;PARK Seong-Min;KANG Ok-Ju;CHEONG Hyo-Sook
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.2
    • /
    • pp.88-93
    • /
    • 2003
  • NIR spectroscopic analysis was used for the measurement of deproteinization and deacetylation to apply the merits of NIR spectroscopic analysis to the quality management in the process of chitin and chitosan production. In measuring squid pen and red snow crab shell, which are raw materials of chitin and chitosan by NIR there were typical peaks in 1200 nm, 1510 nm, 2050 nm and 2180 nm. Squid pen had somewhat higher peak than red snow crab shell. In producing chitin, amount of protein was decreased. Measuring it by NIR, reduction of protein caused by deproteinization was identified in producing chitin. Chitosan is a derivative material made from chitin by processing the deacetylation. During this processing, acetyl groups were removed and amide bends were appeared. From NIR spectra, peaks at 1530 nm and 2030 nm indicated amide II peak of chitosan, and these peaks were used for identifying the differences of structure between chitin and chitosan. The error in measurement of nonidentified sample was below $1\%$ and the error in the standard curve was below 0.006. These errors were very low and the accuracy of NIR was considered to be superior to the existing methods.

Near Infrared Reflectance Spectroscopy for Non-Invasive Measuring of Internal Quality of Apple Fruit

  • Sohn, Mi-Ryeong;Park, Woo-Churl;Cho, Rae-Kwang
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.27-30
    • /
    • 2000
  • In this study, we investigated the feasibility of non-destructive determination of internal quality factors of Fuji apple fruit using near infrared(NIR) reflectance spectroscopy and developed the calibration models. As the reference methods, refractometer, titration and texture analyzer for sugar content, acidity and firmness were used, respectively. Samples were scanned from 1100∼2500nm with InfraAlyzer 500C spectrometer and SESAME software was used for data analysis. A multiple linear regression(MLR) analysis was performed to develop the calibrations. The correlation coefficient(R) and standard error of prediction(SEP) were as follows; 0.91, 0.41$^{\circ}$Brix for sugar content, 0.90, 0.04% for acidity and 0.84, 0.094 kg for firmness, respectively. This study shows that NIR spectroscopy can be used to evaluate the sugar content acidity and firmness of apple fruit with acceptable accuracy.