• Title/Summary/Keyword: NDZ

Search Result 25, Processing Time 0.054 seconds

DYNAMIC CHARGE CARRIER TRANSPORT BEHAVIORS IN ZIRCONIUM OXIDE FOR NUCLEAR CLADDING MATERIALS

  • IL-KYU PARK;SANG-SEOK LEE;YONG KYOON MOK;CHAN-WOO JEON;HYUN-GIL KIM
    • Archives of Metallurgy and Materials
    • /
    • v.65 no.3
    • /
    • pp.1063-1067
    • /
    • 2020
  • Dynamic charge carrier transport behavior in the zirconium (Zr) oxide was investigated based on the frequency-dependent capacitance-voltage (C-V) and temperature-dependent current-voltage (I-V) measurements. The Zr oxide was formed on the ZIRLO and newly developed zirconium-based alloy (NDZ) by corrosion in the PWR-simulated loop at 360℃. The corrosion test for 90 days showed that the NDZ exhibits better corrosion resistance than ZIRLO alloy. Based on the C-V measurement, dielectric constant values for the Zr oxide was estimated to be 11.28 and 11.52 for the ZIRLO and NDZ. The capacitance difference between low and high frequency was larger in the ZIRLO than in the NDZ, which was attributed to more mobile electrical charge carriers in the oxide layer on the ZIRLO alloy. The current through the oxide layers on the ZIRLO increased more drastically with increasing temperature than on the NDZ, which indicating that more charge trap sites exist in the ZIRLO than in NDZ. Based on the dynamic charge carrier transport behavior, it was concluded that the electrical charge carrier transport within the oxide layers was closely related with the corrosion behavior of the Zr alloys.

A Novel Hybrid Anti-islanding Method to Improve Reliability of Utility Interactive Inverter for a PMSG-based Wind Power Generation System (PMSG 기반 풍력발전용 계통연계 인버터의 신뢰성 향상을 위한 새로운 하이브리드 단독운전 방지기법)

  • Kang, Sung-Wook;Kim, Kyeong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.11
    • /
    • pp.27-36
    • /
    • 2013
  • Islanding in a gird connected inverter of wind power generation system may influence a bad effect on equipments or yield safety hazards on grid so it should be detected rapidly and exactly. A passive method to detect islanding is comparatively simpler than an active method but suffers from non detection zone (NDZ). On the other hand, the active method can significantly reduce NDZ by injecting a disturbance into inverter output. To improve the reliability of islanding detection, this paper proposes a hybrid anti-islanding detection method combining the conventional passive method as well as the active method based on novel harmonic injection method using fourier transform. The proposed scheme is fast to detect islanding when NDZ does not exist because it has the nature of passive method. Under NDZ, the active method can detect occurrence of islanding reliably. The effectiveness and validity of the proposed scheme is proved through comparative simulations.

A Novel Anti-Islanding Scheme for Distributed Generation System via accurate Analysis of NDZ (정밀한 불검출영역 해석을 통한 분산전원 시스템의 새로운 단독운전 방지기법)

  • Jo, Yeong-Min;Gu, Bon-Ha;Choy, Ick;Song, Seung-Ho;Choi, Ju-Yeop;Lee, Young-Kwoun;Cho, Sang-Yoon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.121-122
    • /
    • 2015
  • 본 논문에서는 기존의 불검출영역(Non Detection Zone; NDZ) 해석보다 수식적으로 더욱 정밀하게 NDZ를 분석한다. 또한, 이런 NDZ를 벗어나게 하는 최소 이득의 Positive-feedback loop를 가지는 새로운 단독운전 방지기법을 설계하고, 이를 시뮬레이션과 실험을 통해 단독운전 검출 성능을 검증하고 제안하는 기법이 전력품질에 끼치는 영향을 분석한다.

  • PDF

A Simulation for Anti-islanding Method in PV-AF System and Existing Anti-islanding Method (PV-AF시스템에서 단독운전 방지기법 및 기존 단독운전 방지기법의 시뮬레이션 해석 및 비교)

  • Kim, Gyeong-Hun;Seo, Hyo-Ryong;Lee, Soek-Ju;Park, Min-Won;Yu, In-Keun;Jeon, Jin-Hong;Kim, Seul-Gi;An, Jong-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.206-207
    • /
    • 2007
  • Islanding is the electrical phenomenon in a part of a power network disconnected from the utility, where the loads are entirely supplied by PV systems, and where the voltage and frequency are maintained around nominal values. But islanding may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards[4]. Therefore, islanding must be detected and stopped. The existing anti-islanding methods have NDZ(None-detection Zone) or power quality degradation. But PV-AF power generation system has the function of not only shunt active filter but also anti-islanding method without NDZ. In this paper, It is proved that PV-AF system has originally the function of anti-islanding without not only NDZ and but current distortion

  • PDF

Comparison of Three Active-Frequency-Drift Islanding Detection Methods for Single-Phase Grid-Connected Inverters

  • Kan, Jia-rong;Jiang, Hui;Tang, Yu;Wu, Dong-chun;Wu, Yun-ya;Wu, Jiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.509-518
    • /
    • 2019
  • A novel islanding detection method is proposed in this paper. It is based on a frequency drooping PLL, which was presented in a previous work. The cause of errors in the non-detection zone (NDZ) of conventional frequency disturbance islanding detection methods (IDM) is analyzed. A frequency drooping phase-locked-loop (FD-PLL) is introduced into a single-phase grid-connected inverter (SPGCI), which can guarantee that grid current is in phase with the grid voltage. A novel FD-PLL IDM is proposed by improving this PLL. In order to verify the performance of the proposed FD-PLL IDM, a full performance comparison between the proposed IDM and typical existing active frequency drift IDMs is carried out, which includes both dynamic performance and steady performance. With the same NDZ, the total harmonic distortion of the grid-current in the dynamic process and steady state is analyzed. The proposed FD-PLL IDM, regardless of the dynamic or steady process, has the best power quality. Experimental and simulation results verify that the proposed FD-PLL IDM has excellent performance.

Reactive Power P&O Anti-islanding Method of ESS with Critical Load (중요부하를 갖는 ESS의 무효전력 P&O 단독운전 검출 기법)

  • Park, Sung-Youl;Kwon, Min-Ho;Kang, Su-Han;Choi, Se-Wan
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.213-214
    • /
    • 2016
  • 중요부하를 갖는 ESS용 인버터는 정전 발생 시에도 부하에 안정적인 전원을 공급해야 한다. 이를 위하여 모드전환 시 과도상태를 최소화하면서 clearing time에도 부하에 안정적인 전압을 공급할 수 있는 간접전류제어 기법이 연구된 바 있다. 그러나 계통연계 시에도 전압을 제어해주기 때문에 단독운전 시 NDZ을 벗어나지 않아, 기존 알고리즘으로는 단독운전을 검출하기 어렵다는 문제가 있다. 본 논문에서는 모드 전환 시 과도상태를 최소화하면서 단독운전 검출 전에도 부하 전압을 안정하게 제어할 수 있는 간접전류제어 기반 인버터에서 NDZ이 없는 무효전력 P&O 단독운전 검출 기법을 제안한다.

  • PDF

A Novel Hybrid Islanding Detection Method Using Digital Lock-In Amplifier (디지털 록인 앰프를 이용한 새로운 하이브리드 방식의 단독운전 검출법)

  • Ashraf, Muhammad Noman;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.77-79
    • /
    • 2019
  • Islanding detection is one of the most important issues for the distributed generation (DG) systems connected to the power grid. The conventional passive islanding detection methods inherently have a non-detection zone (NDZ), and active islanding detection methods may deteriorate the power quality of a power system. This paper proposes a novel hybrid islanding detection method based on Digital Lock-In Amplifier with no NDZ by monitoring the harmonics present in the grid. Proposed method detects islanding by passively monitoring the grid voltage harmonics and verify it by injecting small perturbation for only three-line cycles. Unlike FFT for the harmonic extraction, DLA HC have lower computational burden, moreover, DLA can monitor harmonic in real time, whereas, FFT has certain propagation delay. The simulation results are presented to highlight the effectiveness of the proposed technique. In order to prove the performance of the proposed method it is compared with several passive islanding detection methods. The experimental results confirm that the proposed method exhibits outstanding performance as compared to the conventional methods.

  • PDF

Analysis of Islanding Detection with Reactive Power Variation Method (RPV 기법의 단독운전 검출에 대한 분석)

  • Park, Gwon-Sik;Seo, Byeong-Jun;Kim, Hak-Soo;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.171-172
    • /
    • 2017
  • 본 논문에서는 분산전원의 계통 연계형 시스템에서의 단독운전 검출 방식인 RPV(Reactive Power Variation)기법에 대한 고찰과 주파수 검출 방식을 분석한다. IEEE 929 - 2000에 근거하여 RPV 기법에서의 NDZ에 대하여 살펴보고, PLL(Phase Locked Loop) 기법을 이용한 주파수 검출에 대한 분석 및 설계와 이를 통한 단독운전 검출을 하고자 한다. 시뮬레이션을 통하여 타당성을 검증하였다.

  • PDF

Simultaneous Determination of Underivatized Diazepam and Nordiazepam in Plasma Using Gas Chromatography/Mass Spectrometry.

  • Choi, Hwa-Kyung;Park, Mee-Jung;Choi, Sang-Gil;Son, Haeng-Ja;Chung, Hee-Sun
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.285-285
    • /
    • 2002
  • Diazepam (DZ) is one of the most frequently prescribed drugs as an antianxiety agent. muscle relaxant. and anticovulsant and sometimes causes intoxication due to accidental overdose, misuse or abuse. DZ is metabolized to nordiazepam (NDZ, desmethyldiazepam), oxazepam (OX) and temazepam (TM) which are also pharmacologically active, although OX and TM do not accumulate in blood or plasma to an appreciable extent. (omitted)

  • PDF

Analysis results of the Anti-islanding Function for PV-AF System (액티브 필터기능을 갖는 3상 태양광 발전시스템의 단독운전 방지기능의 분석)

  • Kim, Gyeong-Hun;Seo, Hyo-Ryong;Jang, Seong-Jae;Park, Sang-Soo;Park, Min-Won;Yu, In-Keun;Jeon, Jin-Hong;Kim, Seul-Ki;Jo, Chang-Hee;Ahn, Jong-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1085-1086
    • /
    • 2008
  • Shunt active filter can compensate harmonic current of utility results from non-linear loads such as rectifiers, cycloconverters and arc furnaces. It has the same structure as photovoltaic(PV) generation system. So, It was proposed the system that generates PV power and also has active filter function. It is called PV-AF(Photovoltaic and Active Filter) power generation system. Islanding can be occurred in an inverter based dispersed generation system, when the system disconnected from utility and loads are entirely supplied by PV system only. Islanding may result in interference to grid protection devices, equipment damage, and even personnel safety hazards. Therefore, islanding has to be detected and protected. The conventional anti-islanding methods have NDZ(None-Detection Zone) or power quality degradation. But PV-AF power generation system has the function of not only shunt active filter but also anti-islanding method without NDZ. In this paper, a novel anti-islanding method for PV-AF system is proposed and analysed in detail.

  • PDF