• 제목/요약/키워드: NDIR gas sensor

검색결과 34건 처리시간 0.026초

써모파일 센서를 이용한 NDIR CO2 가스검출기의 개발 (Development of NDIR CO2 Gas Detector Using Thermopile Sensor)

  • 조시형;박찬원
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.35-38
    • /
    • 2012
  • We present a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. Using this thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

무선센서네트워크 기반 공기질 측정을 위한 비분산적외선 복합가스측정시스템 (NDIR Multi-Gas Measurement System for Air Quality based on Wireless Sensor Network)

  • 백승현;이준영;정상우;박홍배
    • 대한임베디드공학회논문지
    • /
    • 제11권5호
    • /
    • pp.299-304
    • /
    • 2016
  • As public interest in air quality and environment problem is increasing, many researches are being carried out the gas measurement system. Especially, Non-dispersive infrared (NDIR) measurements using Beer-Lambert gas sensing principle with very high selectivity and long life time are noted for reliable method. It is possible to detect various gases such as carbon dioxide (CO2), carbon monoxide (CO), and nitrogen dioxide (NO2), but many researches are mostly concentrated on CO2 sensor. The multi-gas measuring instrument is high price and unwieldy, therefore it is not suitable for wide area required numerous instrument. So we study the NDIR multi-gas measurement system for air quality based on wireless sensor network, and experiment the realized measurement system.

저 농도 감지를 위한 NDIR 방식의 초소형 고정도 메탄센서 모듈 (Development of the Smallest, High-accuracy NDIR Methane Sensor Module to Detect Low Concentration)

  • 김동환;이인;방일순;천동기;김일호
    • 센서학회지
    • /
    • 제27권3호
    • /
    • pp.199-203
    • /
    • 2018
  • In this study, we develop a methane sensor module that can detect low concentrations below 5,000 ppm and measure up to the detection limit of 50 ppm with the NDIR method, with a long lifetime and high accuracy. Methane ($CH_4$) is one of a representative greenhouse gas, which is very explosive. Thus, it is important to quickly and accurately measure methane concentration in the air. To adjust the methane sensor for industrial field applications, a NDIR-based small sensor was implemented and characterized, where its volume was $4cm{\times}4cm{\times}2cm$ and its response time ($T_{90}$) was less than 30 sec. These results demonstrate that the proposed sensor is commercially available for low-concentration measurement, low volume, and fast response application, such as IoT sensor nodes and portable devices.

이산화탄소 검출을 위한 고감도 비분산 적외선 가스센서의 광도파관 구조 설계 (Optical waveguide structure design of Non-dispersive Infrared (NDIR) CO2 gas sensor for high-sensitivity)

  • 윤지영;이준엽;도남곤;정대웅
    • 센서학회지
    • /
    • 제30권5호
    • /
    • pp.331-336
    • /
    • 2021
  • The Non-dispersive Infrared (NDIR) gas sensor has high selectivity, measurement reliability, and long lifespan. Thus, even though the NDIR gas sensor is expensive, it is still widely used for carbon dioxide (CO2) detection. In this study, to reduce the cost of the NDIR CO2 gas sensor, we proposed the new optical waveguide structure design based on ready-made gas pipes that can improve the sensitivity by increasing the initial light intensity. The new optical waveguide design is a structure in which a part of the optical waveguide filter is inclined to increase the transmittance of the filter, and a parabolic mirror is installed at the rear end of the filter to focus the infrared rays passing through the filter to the detector. In order to examine the output characteristics of the new optical waveguide structure design, optical simulation was performed for two types of IR-source. As a result, the new optical waveguide structure can improve the sensitivity of the NDIR CO2 gas sensor by making the infrared rays perpendicular to the filter, increasing the filter transmittance.

실내 공기질 향상을 위한 비분산 적외선 이산화탄소 가스센서 (NDIR CO2 Gas Sensor for Improving Indoor Air Quality)

  • 이승환;박정민;박영환;한승오
    • 한국전기전자재료학회논문지
    • /
    • 제18권7호
    • /
    • pp.628-634
    • /
    • 2005
  • We have simulated and proposed novel optical cavity, which has two elliptical mirrors, for NDIR gas sensor module and have tested it from 0 ppm to 2,000 ppm $CO_2$ concentration. The proposed sensor module shows the maximum peak voltage at 500 ms pulse modulation time, however, it shows a maximum voltage changes at 200 ms pulse duration with 18,000 times amplification gain. From 0 ppm to 2,000 ppm, the voltage difference of sensor module $({\Delta}V)$ shows 360 mV at 200 ms pulse duration and 3 sec turn-off time. The response time of designed sensor module is about 30 seconds.

ASIC칩내장형비분산 적외선 이산화탄소 가스센서의 온도보상 (Temperature Compensation of NDIR $CO_2$ Gas Sensor implemented with ASIC Chip)

  • 박종선;조희찬;이승환
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2006년도 추계학술발표회 논문집
    • /
    • pp.123-128
    • /
    • 2006
  • This paper describes NDIR $CO_2$ gas sensor that shows the characteristics of temperature compensation. It consists of novel optical cavity that has two elliptical mirrors and a thermopile detector that includes ASIC chip in the same metal package for the amplification of detector output voltage and temperature sensor. The newly developed sensor modules shows high accuracy (less than +/-40 ppm) throughout the measuring concentration of $CO_2$ gas from 0 ppm to 2,000 ppm. After implementing the calculation methods of gas concentration, which is based upon the experimental results, the sensor module shows high accuracy less than +/- 5 ppm error throughout the measuring temperature range $(15^{\circ}C\;to\; 35^{\circ}C)$ and gas concentrations.

  • PDF

NDIR 방법을 이용한 복합 가스 측정 시스템 (Composite Gas Measurement System using NDIR Method)

  • 어익수
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.624-629
    • /
    • 2018
  • 본 논문은 NDIR(Non Dispersive Infra Red) 방식을 적용하여 $CO_2$$CH_4$의 두 가지 가스를 하나의 휴대용 장치에서 측정이 가능하도록 제작된 복합 가스 측정 장치에 대한 연구이다. 측정 장치의 구성은 적외선램프에서 적외선이 방출되면 방출된 파장이 광학창을 거치면서 흡수로 인하여 빛이 줄어들게 되고 이 감소량(흡수도)을 검출기에서 검출하고 이를 전기적 신호로 변환 증폭하여(3.5V~6V) 정확한 측정이 가능함을 보여준다. 기존의 Single Sensor 방식은 적외선에서 특수파장을 흡수하여 상대 측정량을 검출하는 방식으로 가스의 경우 $4.26{\mu}m$파장의 빛만을 검출하여 측정하는 방식으로 센서의 값을 보정할 수 있는 기준센서가 없어 오차가 발생하는 문제가 발생하였다. 본 연구에 적용된 Dual Sensor 방식은 다른 가스의 영향을 받지 않는 $3.91{\mu}m$의 기준치와 가스의 $4.26{\mu}m$의 두 파장을 검출하여 비교측정 함으로써 오차가 적어 신뢰도가 높은 방식으로, 휴대형으로 소형화하여 저 전력화가 가능하며, $CO_2$$CH_4$의 2가지 가스농도를 복합적으로 측정 할 수 있다는 특징이 있다. 측정 범위는 $CO_2$의 경우 0ppm~5,000ppm이고 $CH_4$의 경우는 0~5%의 부피 농도로 실내 공기량 1,000ppm을 측정 할 수 있도록 제작되어 휴대용이나 주택의 Home automation과 연동하여 소화연동이 가능함으로 화재예방에 매우 효과적일 것으로 확인하였다.

MEASUREMENT OF $CO_2$ CONCENTRATION AND A/F RATIO USING FAST NDIR ANALYZER ON TRANSIENT CONDITION OF SI ENGINE

  • Lee, S.W.;Kim, W.S.;Lee, J.H.;Park, J.I.;Yoo, J.S.
    • International Journal of Automotive Technology
    • /
    • 제7권4호
    • /
    • pp.385-390
    • /
    • 2006
  • A fast response $CO_2$ analyzer has been developed to study transient characteristics on an SI engine. The analyzer has the delay time of 4.5 ms and time constant of 2.8 ms, which is fast enough to measure $CO_2$ concentration on a transient condition. Wide range of A/F(Air/Fuel) ratio can be estimated using the analyzer with an additional switch type oxygen sensor. The results of measurement of $CO_2$ concentration and A/F ratio on a transient condition including rapid acceleration/deceleration and EGR(Ehxaust Gas Recirculation) on/off are presented and compared with a commercial exhaust gas analyzer and UEGO(Universial Exhaust Gas Oxyzen) sensor.

ASIC 칩 내장형 비분산 적외선 이산화탄소 가스센서의 온도보상 (Temperature Compensation of NDIR $CO_{2}$ Gas Sensor Implemented with ASIC Chip)

  • 이승환;박종선
    • 한국가스학회지
    • /
    • 제11권1호
    • /
    • pp.40-45
    • /
    • 2007
  • 본 논문은 온도보상의 특성을 보여주는 비분산 적외선 이산화탄소 가스센서에 대해 기술하였다. 이 가스센서는 두개의 오목한 반사경을 가진 광 공동, 검출기 출력 전압과 온도센서의 증폭을 위해 동일한 금속 패키지 내에 제작된 ASIC 칩을 포함한 써모파일 검출기로 구성되어 있다. 새롭게 개발된 센서 모듈은 0 ppm에서 2,000ppm까지 이산화탄소 가스의 농도를 측정한 결과 ${\pm}40\;ppm$의 오차를 보였으며, 실험 결과에 기초한 가스농도의 계산 방법으로부터 센서 모듈은 $15^{\circ}C$에서 $35^{\circ}C$ 온도 구간에서 ${\pm}5\;ppm$의 오차를 나타냄으로써 높은 정확성을 가진 자기 온도 보상형 센서를 제작하였다.

  • PDF