• Title/Summary/Keyword: ND4

Search Result 5,040, Processing Time 0.035 seconds

THE EFFECT OF ND : YAG LASER ON DENTINAL TUBULE SEAL AFTER ROOT END RESECTION (치근단절제시 노출된 상아세관의 밀폐효과에 대한 Nd : YAG 레이저의 효과)

  • Shin, Kwang-Chul;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.311-320
    • /
    • 1996
  • If root and resection is done during surgical endodontic treatment, newly exposed dentinal tubules form pathways between the canal and the peripheral tissue. Nd : YAG laser was used to block this phenomenon, and its effect was studied with dye penetration and SEM techniques. 40 intact single rooted teeth were divided into 4 groups(10 each) : control group and test groups, in which retrograde cavity surface, cutting surface, retrograde cavity surface & cutting surface were treated with laser(1 watt 15pps) and finally retrograde filling with IRM was conducted. After that, they were stained with 2 % methylene blue, sectioned and evaluated by the maximum infiltration depth. And to observe surface change, they were prepared for SEM. The results were as follows ; 1. All experimental groups showed microleakage with variation in amount. 2. The 2nd group which treated both the retrograde cavity and cutting surface showed significantly less microleakage than the other groups(p<0.05). There was no significant difference between groups treated on one side only. 3. As a result of SEM observation of dentin surface, obstruction of dentinal tubules with marble shaped granules, which were different from normal dentin could be seen. Cracks could be seen also. 4. In summary of this experiment, it is thought that effort to obstruct the exposed dentinal tubules as well as retrograde cavity after root end resection is needed.

  • PDF

Complex Impedance Characteristics and Electrical Conductivity of ${Nd_{1-x}}{Sr_x}{Ga_{1-x}}{Mg_x}{O_{3-\delta}$ Electrolytes (${Nd_{1-x}}{Sr_x}{Ga_{1-x}}{Mg_x}{O_{3-\delta}$ 고체전해질의 복소임피던스 특성과 전기전도도)

  • ;Allan J. Jacobson
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.4
    • /
    • pp.325-330
    • /
    • 2001
  • 고상반응법으로 이론 밀도의 약 97%의 소결 밀도를 갖는 N $d_{1-x}$S $r_{x}$G $a_{1-x}$M $g_{x}$ $O_{3{\delta}}$(x=0, 0.03, 0.07, 0.1) 고체전해질을 제조하였다. X선 회절 분석 결과, x=0.03일 때의 X선 회절도는 순수한 NdGa $O_3$와 같았으나, x=0.07, 0.1일 때에는 불순물이 나타났다. 교류 복소임피던스는 4$50^{\circ}C$~90$0^{\circ}C$의 온도 범위에서 공기 중에서 측정하였으며, 각 조성에 대하여 상호 비교 분석하기 위하여 복소비저항 스펙트럼으로 변환하여 해석하였다. 전기전도도는 N $d_{0.93}$S $r_{0.07}$G $a_{0.93}$M $g_{0.07}$ $O_{0.97}$(x=0.07) 시편이 90$0^{\circ}C$에서 6$\times$$10^{-3}$ S$cm^{-1}$ /로 가장 우수하였으며, 활성화 에너지는 저온 영역에서는 1 eV, 고온 영역에서는 0.74 eV이었다.다.

  • PDF

A Novel Active Damping Control of a Three-phase PWM Inverter with LC Filter

  • Kim, Kwang-Seob;Hyun, Dong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1589-1596
    • /
    • 2015
  • A novel control method of a three-phase PWM inverter with LC filter is proposed. The transfer function of LC filter is the same as that of 2nd order low pass filter(2nd LPF) which has a zero damping ratio. A simple method of implementing 2nd LPF with damping ratio is to add resistor to inductor or capacitor of LC filter. In an industrial application, it is not practical to adopt damping resistor because it results in losses being proportional to square of current flowing through resistor. Instead of using damping resistors, the proposed active damping control(ADC) utilizes all pass filter(APF) and considers inherent processing delay of digital controller. The overall transfer function of the proposed method is the same as a 2nd LPF and its damping ratio is also controllable via control variables. Detailed design and implementation of controller is also presented. Experiments are conducted with a 7.5kVA induction motor drive system controlled by PWM converter and inverter. Test waveforms are also presented to verify the proposed LC filter control algorithm.

Changes of water quality in upper stream of Dong-jin river (동진강 상류유역의 시기별 수질변화)

  • Son, Jae-Gwon;Choi, Jin-Kyu;Koo, Ja-Woong;Cho, Jae-Young;Song, Jae-Do
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.429-432
    • /
    • 2002
  • The purpose of this study was to get the change of stream water quality in upper stream of Dong-jin river stream, water samples were taken at samling site during 6 month with from march to August in 2002. The water temperature and pH of stream water were ranged $9.0{\sim}29.4^{\circ}C,\;6.48{\sim}9.33$, respectively. The COD values of stream water was ranged from 0.60 to 19.06. The content of T-N and T-P were $1.88{\sim}6.74mg/L$, $ND(not detcted){\sim}0.50mg/L$ by the livestock wastes and agricultural activity, respectively. Also, suspended solids of stream water was ranged $0.4mg/L{\sim}322.0mg/L$. The contents of heavy metal Zn, Cu, and Pb were $ND{\sim}0.070mg/L,\;ND{\sim}0.012mg/L,\;and\;ND{\sim}0.043mg/L$, respectively. Cd was not dected in all the samples.

  • PDF

Prevalence of Disc Degeneration in Asymptomatic Korean Subjects. Part 1 : Lumbar Spine

  • Kim, Sang Jin;Lee, Tae Hoon;Lim, Soo Mee
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Objective : Asymptomatic patients show high degeneration prevalence at lumbar disc in previous literatures. Unfortunately, there are few Korean data, so the authors attempted to analyze the prevalence of disc degeneration in highly selective asymptomatic Korean subjects using MRI. Methods : We performed 3 T MRI sagittal scans from T12 to S1 on 102 asymptomatic subjects (50 men and 52 women) who visited our hospital between the ages of 14 and 82 years (mean age 46.3 years). All images were read independently by three observers (two neurosurgeons and one neuroradiologist) who were not given any information about the subjects. We classified grading for lumbar disc herniation (HN), annular fissure (AF), and nucleus degeneration (ND), using disc degeneration classification. Results : The prevalence of HN, AF, and ND were 81.4%, 76.1%, and 75.8% respectively. Almost all levels showed an age-related proportional tendency with some exceptions. Conclusion : In asymptomatic Korean subjects, the abnormal findings showed high prevalence of AF, ND, and extrusion. Especially in young ages, the authors found that bulging, protrusion, and AF showed high prevalence at L4/5 and L5/S1. And ND showed high prevalence at L5/S1. So, all lumbar disc degenerations are not pathologic, especially in children and adolescents.

CD44 Expression in Healing Nd:YAG Laser Wounds and Scalpel Incisions of the Rat Tongue Mucosa (Nd: YAG 레이져와 수술칼로 절개한 흰쥐 혀점막에서의 CD44 발현)

  • 박미희;박준상;고명연;박봉수
    • Journal of Oral Medicine and Pain
    • /
    • v.22 no.2
    • /
    • pp.261-282
    • /
    • 1997
  • This study was undertaken to compare and investigate the wound healing process following Nd:YAG laser wounds and scalpel incisions of the rat tongue dorsal mucosa. Laser wounds were made parallel on the right side of tongue dorsum and scalpel incisions were made on the left side with 5mm length, respectively Visual inspection and immunohistochemistry with CD44 antibody after immediately, 6 hours, 1 day, 2, 4, 7, 11, 21 days after surgery were carried out. The results were as follows : 1. There was macroscopically no treat difference between laser wounds and scalpel incisions. 2. Laser wounds appeared as dry, bloodless and irregular grooves with carbonization and whitening of superficial tissues compared to sharp, straight and bleeding incisions using scalpel. 3. In the epithelium of rat tongue mucosa, CD44 expression in healing laser wounds and scalpel incisions were similar. 4. In the lamina propria and muscle layer, CD44 expression in healing laser wounds gradually increased earlier and decreased faster than scalpel incisions. Conclusively, it is suggested that pulsed Nd:YAG laser has more beneficial effect on the healing of wounded oral mucosa than scalpel in knew of CD44 expression.

  • PDF

Structure and Electric Properties of PZT Ceramics Substituted by La and Nd (La와 Nd가 치환된 PZT 세라믹의 구조 및 전기적 성질)

  • Jung, Soo-Cheol;Park, Hyu-Bum;Kim, Jeong;Kim, Keon;Kim, Si-Joong
    • Journal of the Korean Ceramic Society
    • /
    • v.31 no.2
    • /
    • pp.155-160
    • /
    • 1994
  • PZT ceramics substituted by La3+ and Nd3+ were fabricated according to the formula: [Pb1-x(La or Nd)x][Zr0.58Ti0.42]1-x/4$\square$x/4O3(x=0.00, 0.02, 0.05, 0.08, 0.15, 0.20). The crystal structure and microstructure were investigated by XRD and SEM. It was observed that the phase transitions among rhombohedral, tetragonal, and cubic symmetry occured as the substitutional quantity increased. Dielectric constant, dissipation factor and piezoelectric coefficient (d33), of each sample were measured. The dielectric properties were changed as the substitutional quanity of rare earth ion increased. These changes could be explained by crystal structure and compositional fluctuaction. Its d33 was higher at tetragonal region near to phase boundry between rhombohedral and tetragonal, which was explained by reorientation of domain wall.

  • PDF

A Study on Effectiveness of Health Education for Middle School Students through Health Education Program in Short Term (단기 보건교육 프로그램을 활용한 중학생 보건교육의 효과분석)

  • 김영복;위자형
    • Korean Journal of Health Education and Promotion
    • /
    • v.14 no.1
    • /
    • pp.11-21
    • /
    • 1997
  • We carried out this study to analyze the effectiveness through health education program in short term which was performed to use the special subject activities. This study was conducted on 63 students who were first grade in S Junior High School from Dec. 1995 to Feb. 1996. To analyze the effectiveness, we performed the Pretest, 1st Posttest, and 2nd Posttest for learned health knowledge. The results were as follows: 1. Most of the students(69.8%) responded that their health were good, and they got the information for health through Mass Com.. The students who had experience of health education were 15.9%, and the 77.8% of the respondents needed the health education. 2. The means of health knowledge on tests were 18.2(Pretest}, 21.5(1st Posttest), and 21.4(2nd Posttest). Increase of health knowledge between Pretest and 1st Posttest was 10.9%. 3. The mean of differences between Pretest and 1st Posttest was 3.26, it was significant(p〈0.01). And the mean of differences between Pretest and 2nd Posttest was 3.19, it was significant(p〈0.01);however, the mean of differences between 1st Posttest and 2nd Posttest was not significant(p=0.2514). 4. The significant main contents were Health Facilities(d=0.42), Pregnancy and Labor(d=0.39), Sex Education(d=0.29), Personal Hygiene(d=0.35), Safety Education (d=0.66), and Drug Abuse(d=0.60)(p〈0.01)

  • PDF

The Use of Grammatical Morphemes of Korean Children with Language Impairment (언어발달지체아동의 문법형태소 사용 특성)

  • Kim, Soo-Young;Pae, So-Yeong
    • Speech Sciences
    • /
    • v.9 no.4
    • /
    • pp.77-91
    • /
    • 2002
  • This study investigated the use of grammatical morphemes (substantive morphemes and connective endings) of Korean speaking children with and without language impairment (LI). Participants were two children (ages 5;11 and 6;2) with SLI (specific language impairment), two LD (language delay) children (ages 6;3 and 6;5) with 70-84 range on a performance-IQ test, and two children (ages 5;7 and 6;1) with ND (normal development). Spontaneous language samples were elicited by play activities and story generation. A total of 8,059 (M=I,343, ranged 966-1,659) intelligible and nonimitative utterances were analyzed by the KCLA 2.0 (Korean Computerized Language Analysis 2.0) program for substantive morphemes and connective endings. The findings of this study were as follows; (1) The Korean speaking children with LI including SLI demonstrated less uses of grammatical morphemes than ND children. (2) Few differences were found between LI and ND children in the use of the grammatical morpheme types. (3) LI children produced significantly higher percentage of grammatical morpheme errors in spontaneous speech than ND children. (4) Few differences were found between SLI and LD children in degrees of the use and the error of grammatical morphemes.

  • PDF

A Study on the Characteristics of Long-term Settlement for Solid Waste Landfill (폐기물매립지의 장기침하 특성에 관한 연구)

  • Park, Jeong Jun;Shin, Eun Chul;Kim, Dong Sik
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.2
    • /
    • pp.52-66
    • /
    • 2008
  • It has been a growing concern about reusing Sudokwon landfill 2nd site and other sanitary landfills located around the metropolitan areas. In this paper, settlement characteristics of Sudokwon landfill 2nd site were studied by analyzing the data collected over the period of six years. Three equations are combined in order to modeling the long-term settlement behavior of refuse landfill caused by mechanical secondary composition and secondary composition caused by the decomposition of biodegradable refuse. It is suggested that mechanical secondary composition is linear with respect to the logarithm of time. The models proposed by hyperbolic method and Gibson & Lo model, power creep law are considered to be suitable for the long-term prediction value of Sudokwon landfill 2nd site. The fifteen-year-period prediction value of hyperbolic method and Gibson & Lo model is considerably different from that of power creep law model. The average settlement for Block I in Sudokwon 2nd site is approximately 3.9m with 4 steps of final landfill stages.

  • PDF