• Title/Summary/Keyword: NATURAL PARK FACILITIES

Search Result 313, Processing Time 0.027 seconds

Satisfaction Level & Improvement Priority of Community Environment According to the Development Concepts of Residential Complexes - The Case of The 3 Residential Complexes in Cheongju Area - (택지개발지구 특성에 따른 거주자의 생활권 내 근린환경만족도 및 개선우선지수 - 청주권 3개 택지개발지구를 중심으로 -)

  • Lee, Sang-Un;Park, Kyoung-Ok
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.77-86
    • /
    • 2010
  • This study has the purpose to reveal the differences of residents' satisfaction level & demand of community environment and recognized residents' improvement priority of community environment at 3 complexes at the big city in the provinces. The 3 residential complexes had differentiated developmental concepts; the residence-oriented complex, the residence-government mixed complex with an eco-friendly concept, and the outskirt residence-industry mixed complex. Followings are the results of the study. 1) The satisfaction of residents in the community environment correlates with the increasing convenience facilities after construction. In the new outskirt complexes of smaller cities, dissatisfaction occurs more with public transportation rather than the road system, so that efficient public transportation systems, inner and neighboring areas, is requisite. 2) Even in the residence-oriented complex, the education environment does not entirely account for satisfaction level; the green environment is also second in priority after the education environment. In the residence-government mixed complex with an eco-friendly concept, a good natural environment does not entirely account for satisfaction level; education environment is also second in priority after the natural environment. The supply of sufficient schools may be fulfilled in the ways of reform of the education zone with neighboring existing residential areas. In the outskirt residence-industry mixed complex of smaller cities, priority was placed more on the location and convenience; this explains the complex's poor access to downtown.

Development of an Analysis Model for UPS System of LNG Receiving Terminal Facilities (천연가스 생산기지 내 UPS시스템의 해석모델 개발)

  • Kook, Seung-Kyu;Hong, Seong-Kyeong;Kim, Joon-Ho;Choi, Won-Mog;Park, Young-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.6
    • /
    • pp.539-545
    • /
    • 2016
  • UPS system in the liquefied natural gas(LNG) receiving terminal is one of the fundamental equipment that need to sustain operation during earthquake. In this study, modal identification test of UPS system was performed based on IEEE Std. 693-2005 and natural frequencies and modal damping, mode shapes had been identified. In addition, tri-axial time history test was performed to check the behavior and stress of the equipment during earthquake. Eigenvalue analysis was performed and analysis model was modified by reflecting the results of the test. Static analysis by dead weight and response spectrum analysis were performed to compare the combined stresses with the stress results of test. Dynamic characteristics and combined stresses under seismic load condition of the improved analysis model were similar to the test results and in this regard the compatibility was proved.

Technical Review on Liquid/Solid (Slush) Hydrogen Production Unit for Long-Term and Bulk storage (장주기/대용량 저장을 위한 액체/고체(Slush) 수소 생산 장치의 해외기술 동향분석)

  • LEE, CHANGHYEONG;RYU, JUYEOL;SOHN, GEUN;PARK, SUNGHO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.6
    • /
    • pp.565-572
    • /
    • 2021
  • Hydrogen is currently produced from natural gas reforming or industrial process of by-product over than 90%. Additionally, there are green hydrogens based on renewable energy generation, but the import of green hydrogen from other countries is being considered due to the output variability depending on the weather and climate. Due to low density of hydrogen, it is difficult to storage and import hydrogen of large capacity. For improving low density issue of hydrogen, the gaseous hydrogen is liquefied and stored in cryogenic tank. Density of hydrogen increase from 0.081 kg/m3 to 71 kg/m3 when gaseous hydrogen transfer to liquid hydrogen. Density of liquid hydrogen is higher about 800 times than gaseous. However, since density and boiling point of liquid hydrogen is too lower than liquefied natural gas approximately 1/6 and 90 K, to store liquid hydrogen for long-term is very difficult too. To overcome this weakness, this paper introduces storage method of hydrogen based on liquid/solid (slush) and facilities for producing slush hydrogen to improve low density issue of hydrogen. Slush hydrogen is higher density and heat capacity than liquid hydrogen, can be expected to improve these issues.

A Study on the Establishment of Disaster Prevention Plans for Nuclear Facilities considering Complex Disasters (복합재난을 고려한 원자력시설 사고대비 방재계획 수립방안)

  • Jihoon Shin;Younwon Park;Seunghyeon Kim;Minho Cha;Minsang Ryu
    • Journal of Korean Society of Disaster and Security
    • /
    • v.16 no.4
    • /
    • pp.85-99
    • /
    • 2023
  • By the social advancement, radiological disaster prevention planning is getting important considering complex disasters as in the Fukushima radiological disaster occurred by a chain of natural disasters. However, it has yet to be suggested the specific prevention plans for the complex disasters in the field of national radiological disaster prevention. This study aims to analyze the types of complex disasters in order to select the ones that are relatively more likely to occur in the domestic environment. It is also to analyze the impact on the radiological disaster prevention by searching damage spread of the classified natural disasters. We provides the necessary criterial for establishing disaster prevention plans through the scenarios for radiological emergency responses based on complex disasters. it is thought that these criteria can help prepare for the worst case scenario and implement effective resident protection.

Design of a Guide Vane for Improving Inside Flow Uniformity of Electrostatic Precipitator (전기집진기 내부의 유동 균일성 향상을 위한 가이드 배인의 최적설계)

  • Noh, Kyung-Wook;Bae, Seong-Jun;Park, Sookhee;Kang, Sunkyun;Lee, Jangmyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.523-528
    • /
    • 2013
  • In recent years, many efforts are increasingly being made to conserve the natural environment with enhanced emission standards and air quality standards. Also there are various methods necessary to be researched to minimize the emission of air pollutants. In particular, boilers of industrial facilities are major portions of the air pollution. The front duct which needs to be designed to reduce the gases to the electrostatic precipitator requires a bent tube, a reduction/extend tube and an auxiliary equipment, that is, a guide vane. This paper proposes an optimum design of the guide vane by a case study for electrostatic precipitator's flow uniformity. The operating conditions of this study are as follows: BMCR (Boiler Maximum Continuous Rate) and MGR (Maximum Guaranteed Rate) are 75%, 50%, and 30%; turbulent fluid dynamics model is based upon K-${\varepsilon}$ formulation. Presentation of the computed motion of particles is found to be quite useful to predict the precipitator performance by use CFD (Computational Fluid Dynamics).

A Study on Factors Influencing Residential Satisfaction by Housing Type and Housing Tenure of Low-Income Households (저소득층의 주택유형 및 점유형태에 따른 주거만족도 영향요인 연구)

  • Park, Yoon-Tae;Won, You-Ho;Kim, Gu-Hoi
    • Journal of the Korean housing association
    • /
    • v.26 no.6
    • /
    • pp.115-126
    • /
    • 2015
  • Using the 2013 Korea Housing Survey, this research analyzed factors influencing residential satisfaction of low-income households concerning the economic condition, satisfaction about interior and exterior environments in dwelling, recognition of housing welfare policy. The economic condition showed that if there are less living expenses and more ordinary income, it brought about more positive effects in the ownership of a detached house, row and multi-family house. Most variables about satisfaction with the interior environment in dwelling have a significant influence on a detached house, apartment, row and multi-family house. The following factors played a significant role: accessibility to commercial facilities, neighborhood relationship and natural environment in the satisfaction with the exterior environment in dwelling about most types. Specifically, from an institutional perspective of housing welfare policy, the effect of the housing expenses support and the intention about remodeling were factors influencing residential satisfaction in cheonsei and monthly rent, free of a detached house and free of an apartment. These results will utilize preliminary data to establish housing welfare policy for low-income households.

Seismic Design for Application of LNG Storage Tank Isolation System (LNG 저장탱크의 면진시스템 적용을 위한 내진설계)

  • Seo, Ki-Young;Park, Hyun-Jae;Kim, Nam-Sik;Kim, Jae-Min;Yang, Seong-Yeong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.227-235
    • /
    • 2014
  • The demand of natural gas is gradually increasing as a clean fuel in the world. Therefore, LNG storage tanks and related facilities of the importance of leading a community-based facility have emerged. The seismic design of LNG storage tank including seismic analysis have been developed steadily. But, the seismic analysis and design techniques for LNG storage tanks are lacking, in Korea. Consequently, it is necessary to develop an analysis model that LNG storage tanks in isolation system can describe the behavior. Further, LNG storage tank capable of ensuring safety and economy, it is necessary to develop design techniques. The studies have suggested seismic design procedures of LNG storage tanks with isolation system including triple-FPB and idealized complex hysteresis model of triple-FPB.

Analysis of Parenting-Friendly Outdoor Environment in Apartment Complexes (아파트단지 옥외공간의 친육아환경 요소에 대한 분석)

  • Kim, Hyo-Jeong;Park, Kyoung-Ok
    • Journal of the Korean housing association
    • /
    • v.28 no.1
    • /
    • pp.95-107
    • /
    • 2017
  • The purpose of the study is to analyze the planning characteristics of outdoor space in apartment complexes in terms of child-care environment. We selected 8 apartment complexes in Cheongju, within three years from construction, of small and medium-sized apartments ($60-85m^2$) where a large number of families with young children are presumed to reside in. As a result of the study, it was found that whereas the factors that can be quantified such as the floor height differences, the angles of ramps, and the number of the rest facilities are excellent, the qualitative part which cannot be easily quantified such as the location and direction of the rest facility and play materials should be improved a lot. And the following improvements were suggested; separating the pedestrian passage from the vehicle road in the main entrance of the complex, utilizing the piloti for infant caring, making the entrance area of apartment safe for pedestrians from vehicles, reallocating resting spaces, redesigning resting spaces safer to infants, building or reallocating existing booths at the stops of kindergarten buses, redesigning the square safer from vehicles with shades, making it possible for guardians to watch infants in playing field from the resting space, allocating natural environments essential for child development.

Physical Properties of Rice Husk (왕겨의 물리적 성질)

  • Park S. J.;Kim M. H.;Shin H. M.
    • Journal of Biosystems Engineering
    • /
    • v.30 no.4 s.111
    • /
    • pp.229-234
    • /
    • 2005
  • Kinetic friction coefficient, bulk density, dynamic and static angle of repose, and terminal velocity of rice husk at the moisture range 7 to $23\%$ w.b. were determined. It could lead to better design and operation of the processing machinery and handling facilities. Friction coefficient was determined from the horizontal traction force measured by pulling the container holding a mass of rice husk on various plate materials. Dynamic angle of repose was calculated from the photos of bulk samples piled by gravity flow on a circular platform. Static angle of repose was determined by measuring the side angle of the bulk material which was left in a cylindrical container after natural discharge of the bulk sample through a circular hole in the bottom plate. Kinetic friction coefficients of rice husk were in the range of $0.254\~0.410,\;0.205\~0.520,\;0.229\~0.400,\;and 0.133\~0.420$ on PVC, mild steel, galvanized steel, and stainless steel, respectively. Bulk density, dynamic and static angle of repose, and terminal velocity were in the range of $91.7\~98.3$ $kg/m^3$, $40.2\~47.6^{\circ},\;52.8\~83.7^{\circ},$ and $1.36\~1.73$ m/s, respectively. These physical properties of rice husk increased linearly as the moisture content increased.

The Development of Optical Fiber Line Operation and Monitor System (광선로 운용감시 시스팀 개발)

  • Kim, Seong-Il;Choi, Shin-Ho;Park, Kap-Seok;Jang, Eun-Sang;Lee, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2492-2494
    • /
    • 1998
  • Recently the optical fiber lines have been widely deployed in the trunk lines and digital data service network. The unexpected failures of optical fiber lines by natural disasters and road construction work have increased rear by rear and the number of damaged telecommunication lines per failures is on increasing. In the meantime, it takes long time to recover the optical fiber lines failures. So, it is important to maintain and monitor the status of optical fiber lines for prevention of optical fiber lines failures. Therefore, KT(Korea Telecom) needs efficient and automatic maintenance system to operate and monitor the optical fiber lines. FLOMS(Fiber Line Operation and Monitor System) had been developed in '96 and pilot system was installed at telephone offices in '97. This paper describes the FLOMS which carries out the functions of efficient maintenance and supports for monitoring optical fiber lines and managing facilities in optical fiber lines.

  • PDF