• Title/Summary/Keyword: N95 mask

Search Result 20, Processing Time 0.022 seconds

Comparisons of Certification Standards for Mask and Review on Filtration Efficiency for Viruses (마스크의 인증기준 비교와 바이러스 여과효율에 대한 고찰)

  • Yoon, Chungsik;Go, Sulbee;Park, Jihoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.109-123
    • /
    • 2020
  • Objectives: The aims of this study were to review the standards and key components of the standards for disposable masks in Korea, the US, EU, Japan, and China and to evaluate the appropriateness of disposable masks during a virus pandemic. Methods: We reviewed the standards in the above countries and compared their key elements for each standard. For the second purpose, systemic paper gathering using key words like 'mask', 'respirator' 'virus', and 'coronavirus' in the PubMed search engine was performed. Fifty-three papers were selected and reviewed in regard to the appropriateness of test protocols with sodium chloride(NaCl) particles for virus filtration and the effectiveness against viruses. Results: The standards for masks are largely divided into two categories: US standards and EU standards. In Korea, the Ministry of Employment and Labor adapted the EU standards for workers and the Health Masks adopted the Ministry of Employment and Labor standards by the Ministry of Food and Drug Safety. Regarding airborne viral infections, WHO emphasizes only droplet infection, while many studies have shown that small particles enter the air through coughing or sneezing, which increases the possibility of airborne infection. Compared to other particles, various factors such as airborne viability and the ability to replicate the virus in the body are further involved in the virus's airborne infection rate. Airborne infection is classified into absolute air infection, preferential air infection, and opportunistic air infection. The NaCl-certified N95 mask showed good filtration efficiency against viruses and NaCl particles were proved to be a surrogate material for viruses. From this, KF94 is also expected to be effective in blocking viruses. Conclusion: The N95 test method could be used as a surrogate test method for virus filtration. N95-class masks have been found to effectively block viral infections in the air. However, surgical or medical masks are only partially effective against airborne virus infection though they could effectively block large droplet infection. However, most studies considered in this study targeted N95 in foreign countries and studies on masks actually used in Korea are very limited, so studies on microorganisms and reuse on domestic masks should be conducted in the future.

Systematic Literature Review on Coronavirus Infectious Disease-19 and Dental Masks

  • Kim, Ji-Hyun;Kim, Min-Young
    • Journal of dental hygiene science
    • /
    • v.21 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • Background: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is transmitted primarily through droplets, and dental practitioners are at risk of occupational exposure to SARS-CoV-2 infection owing to direct contact with the patient's mouth, aerosols from dental procedures, and saliva. Wearing a mask is believed to be the best method of protection against infection, and a systematic literature review was conducted on whether the dental masks used in dentistry are effective in preventing Coronavirus Infectious Disease-19 (COVID-19). Methods: We used PubMed, Google Scholar, DBpia, NDSL, and KISS databases for this study. Of the 917 documents narrowed down by the search terms "Coronavirus, COVID-19, and dental," 83 documents were collected and studied. Ultimately, 42 of these papers were selected for analysis after considering duplication from the flow chart of the literature selection process. Results: While dental masks are often used when treating patients with unknown COVID-19 status, the Ministry of Food and Drug Safety stated that the use of dental masks is insufficient in preventing cross-transmission of COVID-19; instead, it was recommended that N95 masks, which correspond to KF94 masks, should be worn daily. On the other hand, wearing a dental mask and following precautions such as hand hygiene may not pose a significantly higher risk of infection than wearing an N95 mask when treating COVID-19 patients. Conclusion: There is an ongoing discussion regarding the use of dental masks when treating dental patients, and many argue that different types of masks should be selected according to the degree of infection and the individual's respiratory condition. By considering the safety and efficacy of dental masks in preventing infection, improvements can be made in the management of COVID-19 and dental-related infections.

Trend on content of preservatives for emotion-fusioned sheet mask cosmetics in markets (감성 융합형 시트 마스크 화장품의 보존제 함유량 실태)

  • Kang, H.J.;Kang, S.J.;Jo, G.H.;Lee, J.M.;Lee, G.W.
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.11
    • /
    • pp.159-165
    • /
    • 2017
  • We were investigated the content of 7 preservatives for sheet mask samples(n=42) sold in markets of Daejeon metropolitan city in 2016. &3.3%(n=35) of all samples contained at least one of preservatives. In samples of 30.95(n=14) and 2.39%(n=1) was detected with 2 and 3 preservatives. Phenoxyethaol(PE), methylparaben(MP), chlorphenesin(CP) and benzyl alcohol(BA) showed detection rate of 76.19(n=32), 16.67(n=9), 21.43(n=7) and 2.38%(n=1), respectively. Also The content of detected preservative showed range of 0.06~0.71, 0.18~0.35, 0.06~0.71 and 0.32% and was within the maximum allowed amount established by Korean FDA. However ethylparaben(EP), propylparaben(PP) and benzylparaben(BP) in all samples was not detected. These results can be useful for sharing in emotion-fusioned information and supplying right to know of user.

Usage of Filtering-facepiece Masks for Healthcare Workers and Importance of Fit Testing (보건의료종사자의 안면부여과식 마스크의 사용과 밀착도검사의 중요성)

  • Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.245-253
    • /
    • 2015
  • Objectives: One aim of the study is to compare filtering facepiece masks for healthcare workers between Korea and other countries. The other is to emphasize the importance of fit testing for these masks using an analysis of previous research. Materials: An extensive literature review was performed by searching a number of websites and existing studies. Results: KF94 and KF99 masks certified by the Korean CDC are suitable for healthcare workers as filtering facepiece masks. The standards for these respirators are similar to FFP2 and FFP3 of EN 143 and 149. The performance, such as filtering efficiency, is almost the same between KP94 and N95. It was found that fit testing of respirators for healthcare workers was important to reduce infection risk. Conclusions: KF94 should be emphasized as filtering facepiece masks for healthcare workers rather than N95. Even though Korea has no fit testing regulations, implementing fit testing in healthcare settings is strongly recommended to decrease infection risk.

Particulate-Matter Related Respiratory Diseases

  • Kyung, Sun Young;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.2
    • /
    • pp.116-121
    • /
    • 2020
  • Particulate matter (PM) is suspended dust that has a diameter of <10 ㎛ and can be inhaled by humans and deposited in the lungs, particularly the alveoli. Recent studies have shown that PM has an adverse effect on respiratory diseases. The aim of this article is to review respiratory diseases associated with PM. According to existing studies, PM is associated with chronic obstructive pulmonary disease, bronchial asthma, and several other respiratory diseases and increases the mortality rates of these diseases. Moreover, increased exposure in the high concentration of atmospheric PM is associated with the development of lung cancer. The most simple and common way to protect an individual from airborne PM is to wear a face mask that filters out PM. In areas of high concentration PM, it is recommended to wear a face mask to minimize the exposure to PM. However, the use of N95 or KF94 masks can interfere with respiration in patients with chronic respiratory diseases who exhibit low pulmonary function, leading to an increased risk of respiratory failure. Conclusionally, reduction of the total amount of PM is considered to be important factor and strengthening the national warning notification system to vulnerable patients and proper early management of exacerbated patients will be needed in the future.

Deposition of $SiC_xN_y$ Thin Film as a Membrane Application

  • Huh, Sung-Min;Park, Chang-Mo;Jinho Ahn
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.1
    • /
    • pp.39-43
    • /
    • 2001
  • $SiC_{x}N$_{y}$ film is deposited by electron cyclotron resonance plasma chemical vapor deposition system using $SiH_4$(5% in Ar), $CH_4$ and $N_2$. Ternary phase $SiC_{x}N$_{y}$ thin film deposited at the microwave power of 600 W and substrate temperature of 700 contains considerable amount of strong C-N bonds. Change in $CH_4$flow rate can effectively control the residual film stress, and typical surface roughness of 34.6 (rms) was obtained. Extreme]y high hardness (3952 Hv) and optical transmittance (95% at 633 nm) was achieved, which is suitable for a LIGA mask membrane application.

  • PDF

Fit Performance Comparison Between OPC and CNC Based on Number of Ambient Aerosol Particles (시험환경 내 입자수에 대한 OPC, CNC 장비 간 마스크 밀착 성능비교)

  • Seo, Hyekyung;Jang, Hoyeong;Shim, Sua;Kim, Huiju;Han, Donhee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.2
    • /
    • pp.163-171
    • /
    • 2022
  • Objectives: Fit performance may vary depending on the ambient aerosol number and ratio in respective test environment. Although several instrument can measure it, they differ with respect to the measurement principle and the range of ambient aerosols collected to calculate the fit factor. Methods: In this study, the fit performance between a condensation nuclei counter(CNC) and an optical particle counter(OPC) was compared according to ambient aerosol number concentration, and evaluated consistency. One type respirators(N95 masks) was worn by 50 participants PortaCount®(Pro+ 8038) and MT®(05U) were connected with one probe to one mask, and Fit Factors(FFs) were measured simultaneously. Results: The interclass correlation coefficient of the fit factor and ambient aerosol number, as measured by the two instrument, was 0.82 and 0.79, respectively, indicating a high consistency level. On the other hand there was a significant correlation between the successful test performance of the OPC instrument and the ambient aerosol number. Conclusions: The test was passed with the CNC and OPC instruments when the ambient aerosol number was 635-3,332 particles/cm3 and 368-1,976 particles/cm3, respectively. Thus, the ideal ambient aerosol number of particles differed between the two instrument.

Design of PMOS-Diode Type eFuse OTP Memory IP (PMOS-다이오드 형태의 eFuse OTP IP 설계)

  • Kim, Young-Hee;Jin, Hongzhou;Ha, Yoon-Gyu;Ha, Pan-Bong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.1
    • /
    • pp.64-71
    • /
    • 2020
  • eFuse OTP memory IP is required to trim the analog circuit of the gate driving chip of the power semiconductor device. Conventional NMOS diode-type eFuse OTP memory cells have a small cell size, but require one more deep N-well (DNW) mask. In this paper, we propose a small PMOS-diode type eFuse OTP memory cell without the need for additional processing in the CMOS process. The proposed PMOS-diode type eFuse OTP memory cell is composed of a PMOS transistor formed in the N-WELL and an eFuse link, which is a memory element and uses a pn junction diode parasitic in the PMOS transistor. A core driving circuit for driving the array of PMOS diode-type eFuse memory cells is proposed, and the SPICE simulation results show that the proposed core circuit can be used to sense post-program resistance of 61㏀. The layout sizes of PMOS-diode type eFuse OTP memory cell and 512b eFuse OTP memory IP designed using 0.13㎛ BCD process are 3.475㎛ × 4.21㎛ (= 14.62975㎛2) and 119.315㎛ × 341.95㎛ (= 0.0408mm2), respectively. After testing at the wafer level, it was confirmed that it was normally programmed.

Design and Analysis of a Laser Lift-Off System using an Excimer Laser (엑시머 레이저를 사용한 LLO 시스템 설계 및 분석)

  • Kim, Bo Young;Kim, Joon Ha;Byeon, Jin A;Lee, Jun Ho;Seo, Jong Hyun;Lee, Jong Moo
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.224-230
    • /
    • 2013
  • Laser Lift-Off (LLO) is a process that removes a GaN or AIN thin layer from a sapphire wafer to manufacture vertical-type LEDs. It consists of a light source, an attenuator, a mask, a projection lens and a beam homogenizer. In this paper, we design an attenuator and a projection lens. We use the 'ZEMAX' optical design software for analysis of depth of focus and for a projection lens design which makes $7{\times}7mm^2$ beam size by projecting a beam on a wafer. Using the 'LightTools' lighting design software, we analyze the size and uniformity of the beam projected by the projection lens on the wafer. The performance analysis found that the size of the square-shaped beam is $6.97{\times}6.96mm^2$, with 91.8 % uniformity and ${\pm}30{\mu}m$ focus depth. In addition, this study performs dielectric coating using the 'Essential Macleod' to increase the transmittance of an attenuator. As a result, for 23 layers of thin films, the transmittance total has 10-96% at angle of incidence $45-60^{\circ}$ in S-polarization.

Dose Planning of Forward Intensity Modulated Radiation Therapy for Nasopharyngeal Cancer using Compensating Filters (보상여과판을 이용한 비인강암의 전방위 강도변조 방사선치료계획)

  • Chu Sung Sil;Lee Sang-wook;Suh Chang Ok;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.19 no.1
    • /
    • pp.53-65
    • /
    • 2001
  • Purpose : To improve the local control of patients with nasopharyngeal cancer, we have implemented 3-D conformal radiotherapy and forward intensity modulated radiation therapy (IMRT) to used of compensating filters. Three dimension conformal radiotherapy with intensity modulation is a new modality for cancer treatments. We designed 3-D treatment planning with 3-D RTP (radiation treatment planning system) and evaluation dose distribution with tumor control probability (TCP) and normal tissue complication probability (NTCP). Material and Methods : We have developed a treatment plan consisting four intensity modulated photon fields that are delivered through the compensating tilters and block transmission for critical organs. We get a full size CT imaging including head and neck as 3 mm slices, and delineating PTV (planning target volume) and surrounding critical organs, and reconstructed 3D imaging on the computer windows. In the planning stage, the planner specifies the number of beams and their directions including non-coplanar, and the prescribed doses for the target volume and the permissible dose of normal organs and the overlap regions. We designed compensating filter according to tissue deficit and PTV volume shape also dose weighting for each field to obtain adequate dose distribution, and shielding blocks weighting for transmission. Therapeutic gains were evaluated by numerical equation of tumor control probability and normal tissue complication probability. The TCP and NTCP by DVH (dose volume histogram) were compared with the 3-D conformal radiotherapy and forward intensity modulated conformal radiotherapy by compensator and blocks weighting. Optimization for the weight distribution was peformed iteration with initial guess weight or the even weight distribution. The TCP and NTCP by DVH were compared with the 3-D conformal radiotherapy and intensitiy modulated conformal radiotherapy by compensator and blocks weighting. Results : Using a four field IMRT plan, we have customized dose distribution to conform and deliver sufficient dose to the PTV. In addition, in the overlap regions between the PTV and the normal organs (spinal cord, salivary grand, pituitary, optic nerves), the dose is kept within the tolerance of the respective organs. We evaluated to obtain sufficient TCP value and acceptable NTCP using compensating filters. Quality assurance checks show acceptable agreement between the planned and the implemented MLC(multi-leaf collimator). Conclusion : IMRT provides a powerful and efficient solution for complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose. The intensity modulated fields can be efficaciously and accurately delivered using compensating filters.

  • PDF