• Title/Summary/Keyword: N-R Method

Search Result 1,657, Processing Time 0.029 seconds

The Cognitive Performance, Emotional and Behavioral Problems of the Children with ADHD Showing the Difference between Visual and Auditory Attention (시각 주의력과 청각 주의력의 차이를 보이는 주의력 결핍.과잉활동장애 아동의 인지기능과 정서 및 행동 문제)

  • Son, Jung Woo
    • Korean Journal of Biological Psychiatry
    • /
    • v.13 no.2
    • /
    • pp.70-81
    • /
    • 2006
  • Objective : The purpose of this study was to investigate the differences of the cognitive performance, emotional and behavioral problems among the attention-deficit/hyperactivity disorder(ADHD) groups that show the difference between visual and auditory attention. Method : Using 'ADHD Diagnostic System(ADS)', visual attention and auditory attention of 98 children diagnosed as ADHD were measured. According to the omission and commission error of ADS, they were divided into three groups ; 1) the group whose each visual omission and commission error scores were higher than each auditory omission and commission error scores(VV group), 2) the group whose each auditory omission and commission error scores were higher than each visual omission and commission error scores(AA group), 3) the group that was the rest of VV and AA group(M group). And the results of both the subscales of Korean Educational Development Institute-Wechsler Intelligence Scale for Children(KEDI-WISC) and the subscales of Korean Child Behavior Checklist(K-CBCL) among three groups were compared. Finally, the correlation between the visual omission, visual commission, auditory omission, auditory commission error and the results of KEDI-WISC, K-CBCL were investigated. Results : The results were as follows ; 1) In 98 ADHD children, the number of VV group(N=56) was higher than that of AA (N=10) and M group (N=32). 2) All mean scores of the subscales of KEDI-WISC of VV group were higher than those of M and AA group. The score of verbal IQ(p=.039) of VV group was significantly higher than that of AA group and the scores of block design(p=.015), Kaufman's factor 2(p=.045), performance IQ(p=.004) were significantly higher than those of M group. The score of full IQ(p=.004) were significantly higher than that of M and AA group. 3) The mean scores of all K-CBCL subscales of VV group were higher than those of M and AA group, except the score of Somatic complaint subscale. The score of Social subscale(p=.041) of VV group was significantly higher than that of AA group. The score of Withdrawn subscale(p=.021) of AA group was significantly higher than that of VV group. 4) There were no significant correlation between the scores of visual omission/commission error and those of each subscale of KEDI-WISC. But, there were many significant correlations between the scores of auditory omission/commission error and those of each subscale of KEDI-WISC. 5) There were significant correlation between the score of the visual omission error and that of Thought problem subscale(r=.205, p=.043) of K-CBCL. There were significant correlation between the scores of the auditory omission error and those of Social subscale(r=-.319, p=.001), Social problems subscale(r=.206, p=.042), Thought problem subscale(r=.235, p=.021). Finally, there were significant correlation between the scores of auditory commission error and those of Social subscale(r=-.241, p=.017), Thought problem subscale(r=.235, p=.020). Conclusion : The ADHD children whose auditory attention ability were higher than visual attention ability had relatively better cognitive performance and less emotional/behavioral problems than the others. The more comprehensive experiment will be needed about the cognitive performance, emotion and behavior problems of the ADHD children showing the difference between visual and auditory attention.

  • PDF

Evaluation of the Method for Total Homocysteine in Plasma Using LC-MS/MS (LC-MS/MS를 이용한 Homocysteine 측정과 그 유용성 평가)

  • Jun, Sun-Hee;Lim, Mi-Suk;Jung, Yong-Sun;Song, Jung-Han
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.22-26
    • /
    • 2005
  • Total homocysteine is now considered a risk factor for cardiovascular diseases. I increased interest has led to a multitude of studies requiring the determination of total homocysteine in conjunction with other factor. There are various methods for measuring total homocysteine, including HPLC, FPIA, GC-MS and LC-MS/MS. The most recent method for measuring total homocysteine uses a deuterium-labelled internal standard and tandem mass spectrometry. This development requires no derivatization and therefore leads to an increase in sample throughput compared to other techniques. We have evaluated the method for homocysteine by the LC-MS/MS method, and the correlation between the FPIA method and the LC-MS/MS method. The standard curve (0, 5, 10, 20, 50, 100 uM) was linear over the range examined (up to 100 uM). The lower limit of quantification (CV < 10 %) was 0.5 uM/L and the lower limit of detection (S/N >3) was 0.1 uM/L. Intra-assay variation and inter-assay variation were both <6 %. The comparision study for homocysteine concentration showed good correlation (r=0.9684) between the FPIA method and LC-MS/MS methods. Our conclusion is that the method showed relatively good precision, and was rapid and accurate.

  • PDF

Evaluation of Alternative Acute Toxicity Test Method with Daphnia magna (Toxkits에 의한 물벼룩 급성독성시험방법의 제도적용 적합성 평가)

  • Kim, Jongmin;Shin, Kisik;Lee, Jungseo;Lee, Taekjune
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.181-186
    • /
    • 2017
  • This paper aimed to evaluate the results of alternative acute toxicity test on 83 wastewater samples. Each sample was tested by traditional method (using laboratory cultured D. magna as a test organism) and alternative method (using Toxikit which can be purchased from a specialized company). The relationship between Lab. culture toxicity and Toxkits toxicity indicated good relation ($r^2=0.84$, p<0.01, n = 83). Number of samples which showed a small difference of lower than 0.5 between two test methods were 52 and they account for 63 percent of collected samples. In addition, these 52 samples had a lower average toxicity of TU 0.5 (Lab. culture method) and TU 0.45 (Toxkits method). Whereas samples which indicated big difference of test results between two methods, had a tendency to show higher toxicity. From these results, alternative toxicity test method could be applied to the official test method, if samples would have a lower toxicity less than TU 2. Also, Toxikit standard toxicant test results indicated $EC_{50}$ values between 0.93 and 1.68 mg/L and these results were considered as valid for quality control standard.

A Study on the 43$0^{\circ}C$ Degradation Behavior of Cast Stainless Steel(CF8M) (III) - Evaluation of Elastic-Plastic Fracture Toughness - (주조 스테인리스강 CF8M의 43$0^{\circ}C$ 열화거동에 관한 연구 (III) - 탄소성 파괴인성 평가 -)

  • Gwon, Jae-Do;In, Jae-Hyeon;Park, Jung-Cheol;Choe, Seong-Jong;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2405-2412
    • /
    • 2000
  • A cast stainless steel may experience an embrittlement when it is exposed to approximately 30$0^{\circ}C$ for long period. In the present investigation, The three classes of the thermally aged CF8M specimie n are prepared using an artificially accelerated aging method. Namely, after the specimen are held for 300, 1800 and 3600hrs. at 43$0^{\circ}C$ respectively, the specimens are quenched in water to room temperature. Load versus load line displacement curves and J-R curves are obtained using the unloading compliance method. $J_{IC}$ values are obtained following ASTM E 813-87 and ASTM E 813-81 methods. In addition to these methods, JIC values are obtained using SZW(stretch zone width) method described in JSME S 001-1981. The results of the unloading compliance method are $J_Q$=485.7 kJ/m$^2$ for virgin material, $J_{IC}$ of the degraded materials associated with 300, 1800 and 3600hrs are obtained 369.25 kJ/m$^2$, 311.02 kJ/m$^2$, 276.7 kJ/m$^2$, respectively. The results of SZW method are similar to those of the unloading compliance method. Through the elastic-plastic fracture toughness test, it is found that the value of $J_{IC}$ is decreased with increasing of the aging time. The results obtained through the investigation can provide reference data for a leak before break(LBB) of reactor coolant system of nuclear power plants.

Ionic liquid coated magnetic core/shell CoFe2O4@SiO2 nanoparticles for the separation/analysis of trace gold in water sample

  • Zeng, Yanxia;Zhu, Xiashi;Xie, Jiliang;Chen, Li
    • Advances in nano research
    • /
    • v.10 no.3
    • /
    • pp.295-312
    • /
    • 2021
  • A new ionic liquid functionalized magnetic silica nanoparticle was synthesized and characterized and tested as an adsorbent. The adsorbent was used for magnetic solid phase extraction on ICP-MS method. Simultaneous determination of precious metal Au has been addressed. The method is simple and fast and has been applied to standard water and surface water analysis. A new method for separation/analysis of trace precious metal Au by Magnetron Solid Phase Extraction (MSPE) combined with ICP-MS. The element to be tested is rapidly adsorbed on CoFe2O4@SiO2@[BMIM]PF6 composite nano-adsorbent and eluted with thiourea. The method has a preconcentration factor of 9.5-fold. This method has been successfully applied to the determination of gold in actual water samples. Hydrophobic Ionic Liquids (ILs) 1-butyl-3-methylimidazole hexafluorophosphate ([BMIM]PF6) coated CoFe2O4@SiO2 nanoparticles with core-shell structure to prepare magnetic solid phase extraction agent (CoFe2O4@SiO2@ILs) and establish a new method of MSPE coupled with inductively coupled plasma mass spectrometry for separation/analysis of trace gold. The results showed that trace gold was adsorbed rapidly by CoFe2O4@SiO2@[BMIM]PF6 and eluanted by thiourea. Under the optimal conditions, preconcentration factor of the proposed method was 9.5-fold. The linear range, detection limit, correlation coefficient (R) and relative standard deviation (RSD) were found to be 0.01~1000.00 ng·mL-1, 0.001 ng·mL-1, 0.9990 and 3.4% (n = 11, c = 4.5 ng·mL-1). The CoFe2O4@SiO2 nanoparticles could be used repeatedly for 8 times. This proposed method has been successfully applied to the determination of trace gold in water samples.

Resolution of Salbutamol Enantiomers in Human Urine by Reversed-phase High Performance Liquid Chromatography after Derivatization with (S)-(-)-${\alpha}$-methylbenzyl isocyanate

  • Kim, Kyeong-Ho;Kim, Tae-Kyun;Kwon, Young-Hee;Sohn, Young-Teak
    • Archives of Pharmacal Research
    • /
    • v.20 no.5
    • /
    • pp.486-490
    • /
    • 1997
  • A stereospecific HPLC method has been developed for the resolution of the enantiomers of salbutamol in human urine. After solid-phase extraction and derivatization with (S)-(-)-${\alpha}$-methyl-benzyl isocyanate, the diastereomeric derivatives were resolved $(R_s=1.59)$ on $5{\mu}M$ octadecylsilan column using 47% methanol as a mobile phase with fluorescence detection. The detection limit of each enantiomer was 10 ng/ml (S/N=3).

  • PDF

Study on the Friction Characteristics of Advanced High Strength Steel Sheet (초고강도강판의 마찰특성에 관한 연구)

  • Kim, N.J.;Kim, S.H.;Jung, K.R.;Park, S.B.;Keum, Y.T.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.250-253
    • /
    • 2009
  • In this study, the friction test was performed to find friction characteristics of advanced high strength steel (AHSS) sheets and the multiple regression method was employed to obtain friction models. The friction coefficients associated with the lubricant viscosity, drawing speed, and blank holding pressure are measured. Differently from GA steel sheets, the effects of the lubricant viscosity and pulling speed are a little, which are explained by a theory of adhesion and wear as well as a deformation of friction surface. In addition, the effects of friction parameters are numerically represented by friction regression models.

  • PDF

Progressive failure of symmetric laminates under in-plane shear: Il-Negative shear

  • Singh, S.B.;Kumar, Ashwini;Iyengar, N.G.R.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.7
    • /
    • pp.757-772
    • /
    • 1998
  • The objective of the present work is to estimate the strength and failure characteristics of symmetric thin square laminates under negative shear load. Two progressive failure analyses, one using the Hashin criterion and the other using a Tensor polynomial criterion, are used in conjunction with the finite element method. First-order shear-deformation theory along with geometric nonlinearity in the von Karman sense has been incorporated in the finite element modeling. Failure loads, associated maximum transverse displacements, locations and modes of failure including the onset of delamination are discussed in detail; these are found to be quite different from those for the positive sheer load reported in Part I of this study (Singh et al. 1998).

Ionic Liquids: An Environmentally Friendly Media for Nucleophilic Substitution Reactions

  • Jorapur, Yogesh R.;Chi, Dae-Yoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.3
    • /
    • pp.345-354
    • /
    • 2006
  • Ionic liquids are alternative reaction media of increasing interest and are regarded as an eco-friendly alternatives, of potential use in place of the volatile organic solvents typically used in current chemical processing methods. They are emerging as the smart and excellent solvents, which are made of positive and negative ions that they are liquids near room temperature. The nucleophilic substitution reaction is one of the important method for inserting functional groups into a carbon skeleton. Many nucleophilic substitution reactions have been found with enhanced reactivity and selectivity in ionic liquid. In this review, some recent interesting results of nucleophilic substitution reactions such as hydroxylations, ether cleavages, carbon-X (X= carbon, oxygen, nitrogen, fluorine) bond forming reactions, and ring opening of epoxides in ionic liquids are discussed.

Porous Organic-inorganic Hybrids for Removal of Amines

  • Cho, Sung-Youl;Kim, Na-Ri;Cao, Guozhong;Kim, Joong-Gon;Chung, Chan-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.3
    • /
    • pp.399-402
    • /
    • 2006
  • Porous organic-inorganic hybrids have been prepared from tetraethylorthosilicate (TEOS) and organosilane precursors by sol-gel method. Two organosilanes, 3-(2,4-dinitrophenylamino)propyltriethoxysilane (DNPTES) and N-[[(2-nitrophenyl)methoxy]carbonyl]-3-triethoxysilylpropylamine (NPTES) were used to incorporate electron-accepting (di)nitrophenyl groups into the hybrids. The hybrids were characterized by FT-IR spectroscopy and elemental analysis, and their pore characteristics were studied by nitrogen sorption porosimetry. Surface area of the hybrids ranged from 563 to 770 $m^2$/g, pore volume, 0.23-0.30 $cm^3$/g, and porosity, 35-41%. It was demonstrated by UV-vis spectroscopy that aniline, ethylenediamine, and 1-aminonaphthalene could be removed from their hexane solutions in the presence of the hybrid powders. The removal of amines is attributable to donor-acceptor interaction between the electron-donating amines and electron-accepting (di)nitrophenyl moiety.