• Title/Summary/Keyword: N loss

Search Result 2,533, Processing Time 0.026 seconds

Tribology of Si3N4 Ceramics Depending on Amount of Added SiO2 Nanocolloid (SiO2 나노 콜로이드 첨가량에 따른 질화규소의 트라이볼러지)

  • Nam, Ki-Woo;Chung, Young-Kyu;Hwang, Seok-Hwan;Kim, Jong-Soon;Moon, Chang-Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.3
    • /
    • pp.267-272
    • /
    • 2011
  • We analyzed the wear characterization of $Si_3N_4$ ceramics according to the amount of added $SiO_2$ nanocolloid. The test specimen was prepared by hot-press sintering at 35 MPa and 2123 K in an $N_2$ gas atmosphere for 1 h. A wear test was performed with a block-on-ring tester, and the test conditions were as follows: (1) the ring with a diameter of 35 mm had a rotational speed of 50 rpm; (2) the load was 9.8 N; and (3) the temperature was $25^{\circ}C$. The test results show that $Si_3N_4$ ceramics have a friction coefficient of about 1.0 and a wear loss of about 0.02 mm. Of the specimens used this study, the test specimen with 1.3 wt% of added $SiO_2$ nanocolloid has the best wear resistance because it has the lowest friction coefficient and the smallest wear loss. This specimen also has the highest Vickers hardness and bending strength. In this study, the friction coefficient is inversely proportional to the hardness and bending strength.

Separation of H2 and N2 Gases by PTMSP-NaA Zeolite Composite Membranes (PTMSP-NaA Zeolite 복합막에 의한 수소-질소 기체 분리에 관한 연구)

  • Kim, Ok-Su;Yun, Seok Il
    • Membrane Journal
    • /
    • v.25 no.2
    • /
    • pp.107-114
    • /
    • 2015
  • PTMSP-NaA zeolite composite membranes were prepared by adding 0~50 wt% NaA zeolite to PTMSP. The membranes were characterized by FT-IR, $^1H$-NMR, GPC, DSC, TGA, SEM. The permeabilities of $H_2$ and $N_2$ gases through PTMSP-NaA zeolite composite membranes was studied as a function of NaA zeolite contents. According to TGA measurements, when zeolite was inserted into the polymer, weight loss temperature and weight loss wt% of PTMSP-NaA zeolite composite membranes were decreased. Based on SEM observation, NaA zeolite was dispersed in the PTMSP-NaA zeolite composite membrane with the size $2{\sim}5{\mu}m$. The permeability of PTMSP-NaA zeolite composite membranes increased added as NaA zeolite content increased. On the contrary, the selectivity ($H_2/N_2$) of the composite membranes decreased as NaA zeolite content increased. PTMSP-NaA zeolite composite membrane showed better permeability and selectivity ($H_2/N_2$) of $H_2$ and $N_2$ than PTMSP-NaY zeolite composite membrane.

A Study on the Flow Characteristics of Newtonian Fluid and Non-Newtonian Fluid in Dividing Tubes (분기관내 뉴턴 유체 및 비뉴턴 유체의 유동특성에 관한 연구)

  • Ha, O.N.;Chun, U.H.;Kim, G.;Lee, B.K.;Lee, H.S.;Yun, C.H.;Lee, J.I.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.113-131
    • /
    • 1998
  • The objective of the present study is to investigate the characteristics of the dividing flow in the laminar flow region. Using glycerine water solution(wt43%) for Newtonian fluid and the polymer of viscoelastic fluid(500wppm) for non-Newtonian fluid, this research investigates the flow state of the dividing tube in steady laminar flow region of the two dimensional dividing tube by measuring the effect of Reynolds number, dividing angle, and the flow rate ratio on the loss coefficient. In T- and Y-type tubes, the loss coefficients of the Newtonian fluid decreases in constant rate when the Reynolds number is below 100. The effect of the flow rate ratio on the loss coefficients is negligible. But when the Reynolds number is over 100, the loss coefficient with various flow rate ratios approach an asymptotic value. The loss coefficient of the non-Newtonian fluid for different the Reynolds number shows the similar tendency of the Newtonian fluid. And when the Reynolds number is over 300, the loss coefficient is approximately 1.03 regardless of flow rate ratio or the dividing angle. The aspect ratio does hardly influence the reattachment length and the loss coefficient of both Newtonian and non Newtonian fluid. The loss coefficient decreases as the Reynolds number increases. The loss coefficient of Newtonian fluid is larger than that of non-Newtonian fluid.

  • PDF

Core Loss Analysis of Non-oriented Electrical Steel Under Magnetic Induction Including Higher Harmonics

  • Cho, Chuhyun;Son, Derac;Cho, Youk
    • Journal of Magnetics
    • /
    • v.6 no.2
    • /
    • pp.66-69
    • /
    • 2001
  • The actual magnetic induction waveform of cores in electrical machines is not sinusoidal i.e. higher harmonics are always included. Thus the core loss in actual electrical machines is different from the core loss which is measured by the standard method, because the waveform of magnetic induction should be sinusoidal in the standard testing method. Core loss analysis under higher harmonic induction is always important in electric machine design. In this works we measured the core loss when a hysteresis loop has only one period of an ac minor loop of higher harmonic frequency, depending on the position of the ac minor loop of relative to the fundamental harmonic frequency. From this experiment, the core loss P(B/sub 0/f/sub 0/, B/sub h/, nf/sub 0/)) under a higher harmonic magnetic induction B/sub h/ could be expressed by the linear combination the core loss at fundamental harmonic frequency P/sub c/(B/sub 0/, f/sub 0/), the core loss of ac minor loop at zero induction region of the major hysteresis loop P/sub cL/ (B/sub h/, nf/sub 0/), and the core loss of an ac minor loop in the high induction region of the major hysteresis loop P/sub cH/ (B/sub h/, nf/sub 0/) i.e., P/sub c/, (B/sub 0/, f/sub 0/, B/sub h/, nf/sub 0/)=P/sub c/ (B/sub 0/, f/sub 0/,)+(n-1)[k₁(B/sub 0/) P/sub cL/ (B/sub h/, nf/sub 0/)+(1-k₁(B/sub 0/)) P/sub cH/ (B/sub h/, nf/sub 0/)]. This will be useful formula for electrical machine designers and one of effective methods to predict core loss including higher harmonic induction.

  • PDF

The Design of High Gain Waveguide Array Antenna Combining Horn Antenna (혼안테나를 결합한 고 이득 도파관 배열 안테나 설계)

  • Lee, Han-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.257-260
    • /
    • 2014
  • In this paper, a high gain waveguide array antenna combining horn antenna on slot radiator was designed. And the fabricated antenna showed enough gain, improved efficiency and broadband characteristics for receiving satellite signals, compare to conventional microstrip antenna which has dielectric loss and radiation loss on transmission line. For easy fabrication, the waveguide structure was composed by 3-stages of radiator, signal coupler and transmission line. By experiment, the array waveguide antenna of 4 by 16 showed 28.3[dBi] gain and 2:1 of VSWR. And by combining horn antenna structure, the gain was increased 1[dB]. The received signal from Koreasat 6 by measurement showed 16[dBc] of C/N on BS(Broadcasting Satellite)-band and 14[dBc] of C/N on CS(Communication Satellite)-band.

4181Overcoming the High-current Efficiency Loss Mechanism in GaN-based Light-emitting Diodes

  • Kim, Jong-Gyu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.23.2-23.2
    • /
    • 2011
  • This presentation will include an overview of III-Nitride LED technology, applications, key areas for future improvements, challenges such as efficiency droop. GaN-based high-power light-emitting diodes (LEDs) suffer from high-current loss mechanisms that lead to a significant decrease in internal quantum efficiency at high drive currents, a well-known phenomenon commonly referred to as efficiency droop. Although many attempts have been made to uncover this LED's darkest secret, there is still a lack of consensus on the dominant mechanism responsible for this detrimental phenomenon. In this presentation, proposed origins and corresponding solutions to the droop-causing mechanisms will be reviewed and discussed.

  • PDF

An Algorithm for Computing the Fundamental Matrix of a Markov Chain

  • Park, Jeong-Soo;Gho, Geon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.22 no.1
    • /
    • pp.75-85
    • /
    • 1997
  • A stable algorithm for computing the fundamental matrix (I-Q)$^{-1}$ of a Markov chain is proposed, where Q is a substochastic matrix. The proposed algorithm utilizes the GTH algorithm (Grassmann, Taskar and Heyman, 1985) which is turned out to be stable for finding the steady state distribution of a finite Markov chain. Our algorithm involves no subtractions and therefore loss of significant digits due to concellation is ruled out completely while Gaussian elimination involves subtractions and thus may lead to loss of accuracy due to cancellation. We present numerical evidence to show that our algorithm achieves higher accuracy than the ordinagy Gaussian elimination.

  • PDF

Removal of Heterogeneous Candidates Using Positional Accuracy Based on Levenshtein Distance on Isolated n-best Recognition (레벤스타인 거리 기반의 위치 정확도를 이용하여 다중 음성 인식 결과에서 관련성이 적은 후보 제거)

  • Yun, Young-Sun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.8
    • /
    • pp.428-435
    • /
    • 2011
  • Many isolated word recognition systems may generate irrelevant words for recognition results because they use only acoustic information or small amount of language information. In this paper, I propose word similarity that is used for selecting (or removing) less common words from candidates by applying Levenshtein distance. Word similarity is obtained by using positional accuracy that reflects the frequency information along to character's alignment information. This paper also discusses various improving techniques of selection of disparate words. The methods include different loss values, phone accuracy based on confusion information, weights of candidates by ranking order and partial comparisons. Through experiments, I found that the proposed methods are effective for removing heterogeneous words without loss of performance.

Synergistic Effect on Corrosion Inhibiton Efficiency of Ginger Affinale Extract in Controlling Corrosion of Mild Steel in Acid Medium

  • Subramanian, Ananth Kumar;Arumugam, Sankar;Mallaiya, Kumaravel;Subramaniam, Rameshkumar
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.6
    • /
    • pp.672-676
    • /
    • 2013
  • The corrosion inhibition nature of Ginger affinale extract for the corrosion of mild steel in 0.5N $H_2SO_4$ was investigated using weight loss, electrochemical impedance and potentiodynamic polarization methods. The results revealed that Ginger affinale extract acts as a good corrosion inhibitor in 0.5N $H_2SO_4$ medium. The inhibition efficiency increased with an increase in inhibitor concentration. The inhibition could be attributed to the adsorption of the inhibitor on the steel surface.

Effect of S-AITA on Mild Steel Corrosion in Acidic Medium

  • Chandrasekaran, V.;Saravanan, J.
    • Corrosion Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.160-167
    • /
    • 2006
  • S-Acetyl Isothiourea Acetate (S-AITA) was synthesized in the laboratory and this influence on the inhibition of corrosion of mild steel in 1.11 N hydrochloric and 1.12 N sulphuric acids was investigated by weight loss and potentiostatic polarization techniques at 303K, 353K and 403K. These results were confirmed by the impedance technique. The inhibition efficiency increased with increase in concentration of inhibitor and decreased with rise in temperature from 303K to 403K. The maximum inhibition efficiency of S-AITA was found to be 99.95% (0.5% of S-AITA) at 303K in sulphuric acid. The adsorption of this compound on the mild steel surface from the acids has been found to obey Temkin's adsorption isotherm. The potentiostatic polarization results revealed that S-AITA was a mixed type inhibitor. Some thermodynamic parameters i.e., activation energy (Ea), free energy of adsorption (${\Delta}G_{ads}$), enthalpy of adsorption (${\Delta}H$) and entropy of adsorption (${\Delta}S$) were also calculated from weight loss data.