• Title/Summary/Keyword: N loss

Search Result 2,531, Processing Time 0.044 seconds

Nitrogen Isotope Compositions of Synthetic Fertilizer, Raw Livestock Manure Slurry, and Composted Livestock Manure (화학비료, 가축분뇨 및 퇴비의 질소동위원소비)

  • Lim, Sang-Sun;Lee, Sang-Mo;Lee, Seung-Heon;Choi, Woo-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.4
    • /
    • pp.453-457
    • /
    • 2010
  • To investigate the difference in N isotope ratio ($^{15}N/^{14}N$, expressed as ${\delta}^{15}N$) among N sources (synthetic fertilizer, livestock manure, and manure compost), eight synthetic fertilizer, four livestock manure, and thirty-seven compost samples were collected and analyzed for ${\delta}^{15}N$. The mean ${\delta}^{15}N$ values of N sources were $-1.5{\pm}0.5$‰ (range: -3.9 to +0.5‰) for synthetic fertilizer, $+6.3{\pm}0.4$‰ (+5.3 to +7.2‰) for manure, and $+16.0{\pm}0.4$‰ (+9.3 to +20.9‰) for compost. The lower ${\delta}^{15}N$ of synthetic fertilizer was attributed to its N source, atmospheric $N_2$ of which ${\delta}^{15}N$ is 0‰ Meanwhile, more $^{15}N$-enrichment of compost than manure was assumed to be resulted from N isotopic fractionation (faster loss of $^{14}N$-bearing compound than $^{15}N$) associated with N loss particularly via $NH_3$ volatilization during composting. Therefore, our study shows that ${\delta}^{15}N$ values could successfully serve in discriminating two major N sources (synthetic fertilizer and compost) in agricultural system.

Comparison of Treatment Compliance and Nutritional Outcomes among Patients with Nasopharyngeal Carcinoma with and without Percutaneous Endoscopic Gastrostomy during Chemoradiation

  • Peerawong, Thanarpan;Phungrassami, Temsak;Pruegsanusak, Kovit;Sangthong, Rassamee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.11
    • /
    • pp.5805-5809
    • /
    • 2012
  • Aims: The study aimed to compare treatment compliance and nutritional outcomes in nasopharyngeal carcinoma (NPC) patients during chemoradiation. Methods: Clinical information of patients with NPC that underwent chemoradiation during 2004-2009 were retrieved from the hospital database and retrospectively reviewed. Patients were categorised into a prophylactic percutaneous endoscopic gastrostomy (PPEG) group and a non-PPEG group. Clinical information including treatment compliance, weight, haematological and renal toxicity was compared. Results: A total of 219 patients were reviewed and categorised into PPEG (n=77) and non-PPEG (n=142). Significant differences in absolute percentage weight loss between groups were found from the $3^{rd}$ cycle of chemotherapy. There were 24.2, 20.3 and 24.8% in the third, the fourth and the fifth cycles of chemotherapy, respectively. Migration of grade 2 to grade 3 weight loss was obviously seen in the $3^{rd}$ cycle as well. A significant difference of grade 3 or more hypokalemia was found with values of 14.3% and 50% in the PPEG and non-PPEG groups, respectively. Other toxicity parameters and treatment compliance were not different between the groups. Conclusions: Use of PPEG resulted in decreased severe weight loss, reduced migration from grade 2 to grade 3 weight loss and reduced hypokalaemia. However, benefits in treatment compliance could not be detected. So consideration of PPEG in NPC patients requires care.

A 20-way Stripline Power Divider for an S band Linear Array Antenna with Low Loss and Low Side Lobe Level (S 대역 선형 배열 안테나 급전회로를 위한 저손실, 저부엽 20-출력 스트립라인 전력분배기)

  • Kwon, Tae-Min;Kim, Dong-Wook
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.7
    • /
    • pp.128-134
    • /
    • 2010
  • In this paper, a high-power 20-way stripline power divider with low insertion loss and low side lobe level is successfully designed, fabricated and measured as a feed network for an S-band linear array antenna having Dolph-Chebyshev current distribution which has a narrow beam width and very low side lobe level (SLL). The 20-way stripline power divider consists of an 8-way power divider, three 4-way power dividers and three ring hybrids. It utilizes a T-junction structure as a basic element for power dividing. Notches and modified input/output N-to-stripline transitions are used for improving insertion loss and return loss. The fabricated power divider shows insertion loss less than 0.3 ㏈ and rms phase mismatch less than 8o in the full bandwidth. A final 40-way power divider is synthesized by combining symmetrically two 20-way power dividers and is expected to have SLL over 40 dB, based on the measured results of the 20-way power divider.

Effects of Ulinastatin on Postoperative Blood Loss and Hemostasis in Atrioventricular Valve Surgery with Cardiopulmonary Bypass

  • Park, Jae Bum;Kim, Seong Hyop;Lee, Song Am;Chung, Jin Woo;Kim, Jun Seok;Chee, Hyun Keun
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.185-191
    • /
    • 2013
  • Background: Cardiopulmonary bypass (CPB) induces variable systemic inflammatory reactions associated with major organ dysfunction via polymorphonuclear neutrophils (PMNs). Ulinastatin, a urinary trypsin inhibitor, inhibits PMN activity and reduces systemic inflammatory responses. The aim of this study is to evaluate the effect of ulinastatin on postoperative blood loss and laboratory changes in patients undergoing open heart surgery. Materials and Methods: Between January 2008 and February 2009, 110 patients who underwent atrioventricular valve surgery through right thoracotomy were divided into two groups. Patients received either 5,000 U/kg ulinastatin (ulinastatin group, n=41) or the equivalent volume of normal saline (control group, n=69) before aortic cross clamping. The primary end points were early coagulation profile changes, postoperative blood loss, transfusion requirements, and duration of intubation and intensive care unit stay. Results: There were no statistically significant differences between the two groups in early coagulation profile, other perioperative laboratory data, and postoperative blood loss with transfusion requirements. Conclusion: Administration of ulinastatin during operation did not improve the early coagulation profile, postoperative blood loss, or transfusion requirements of patients undergoing open heart surgery. In addition, no significant effect of ulinastatin was observed in major organs dysfunction, systemic inflammatory reactions, or other postoperative profiles.

Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment

  • Seo, Yong-Ho;Bae, Eun-Bin;Kim, Jung-Woo;Lee, So-Hyoun;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.313-320
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients. MATERIALS AND METHODS. Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evaluated on sixteen patients who were treated with mandibular overdenture and have used it for at least 1 year (Locator implant attachment: n=8, Locator bar attachment: n=8). RESULTS. Marginal bone loss, probing depth, plaque index of the Locator bar attachment group were significantly lower than the Locator implant attachment group (P<.05). There was no significant difference on bleeding, peri-implant inflammation, and patient satisfaction between the two denture types (P>.05). The replacement of the attachment components was the most common complication in both groups. Although there was no correlation between marginal bone loss and plaque index, a significant correlation was found between marginal bone loss and probing depth. CONCLUSION. The Locator bar attachment group indicates lesser marginal bone loss and need for maintenance, as compared with the Locator implant attachment group. This may be due to the splinting effect among implants rather than the types of Locator attachment.

Obstetric Outcomes in 68 Pregnant Patients with Recurrent Pregnancy Loss on Oreintal Treatment and Analysis of Factors Affecting the Success of Birth (한방치료 후 임신에 성공한 반복 임신손실 환자 68례의 산과적 결과 및 출산 성공 영향 인자의 분석)

  • Ie, Jae-Eun;Heo, Su-Jung;Cho, Hyun-Ju;Moon, Hyon-Ju
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.23 no.3
    • /
    • pp.173-183
    • /
    • 2010
  • Purpose: To estimate the effect of oriental treatment on recurrent pregnancy loss, a retrospective analysis was done. Methods: Sixty-eight pregnant women at the $\bigcirc\bigcirc$ oriental clinic, Korea, from January 2005 to May 2009 diagnosed as recurrent pregnancy loss were included in this study. The sixty-eight patients received oriental treatment such as acupuncture, moxibution, herbal acupuncture and herbal prescriptions, divided into two groups: Group A- live birth(N=58) and Group B- abortion(N=10). The maternal age, parity, menstrual history, gynecological history and period of treatment were compared. To find out factors affecting the success of birth, we performed binary logistic regression analysis(SPSS ver. 14.0 for windows). Results: The live birth rate was 85.3%. The maternal age, parity, menstrual history, gynecological history and period of treatment were not different between two groups. Logistic regression analysis showed that the significant factors predicting the occurrence of miscarriage were advanced maternal age(${\geq}35$)(P=0.005, Odds Ratio[OR]=3.809, 95% Confidence Interval[95%CI]: 1.514-9.585) and suffering from gynecological problems(P=0.044, OR=4.048, 95%CI: 1.037-15.801). Conclusions: The results suggest that oriental treatment has effectiveness on recurrent pregnancy loss. Further study will be needed.

Environmental Influences on Gas pressure Sintering of $Si_3N_4$ (질화규소의 가스압 소결에 미치는 환경 영향)

  • 김인섭;이경희;이병하
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.4
    • /
    • pp.309-315
    • /
    • 1993
  • Gas pressure sintering is a promising process in various densification methods of high strength Si3N4 ceramics. Environmental influences on gas pressure sintering of Si3N4 was investigated with the variationof packing powder, specimen container and N2 gas pressure. The specimens had higher density, larger weight loss and inhomogeneous color in graphite specimen container than in SN26 crucible. The variations of sintering densities in various packing powders (Si3N4, SN26, AlN, BN) were very small but SiC powder was synthesised in graphite crucible with Si3N4 packing powder, aluminium oxynitride compounds were synthesised in SN26 crucible with AlN packing power. Also N2 gas pressure over 20kg/$\textrm{cm}^2$ reduced the densification of Si3N4 in one step-gas pressure sintering. As the result of two step-gas pressure sintering at 700kg/$\textrm{cm}^2$ for 15min., relative density of 99.9% and 3-point bending strength of 1090MPa and dense microstructure of 3~4${\mu}{\textrm}{m}$ grain size were obtained.

  • PDF

PRECISE LARGE DEVIATIONS FOR AGGREGATE LOSS PROCESS IN A MULTI-RISK MODEL

  • Tang, Fengqin;Bai, Jianming
    • Journal of the Korean Mathematical Society
    • /
    • v.52 no.3
    • /
    • pp.447-467
    • /
    • 2015
  • In this paper, we consider a multi-risk model based on the policy entrance process with n independent policies. For each policy, the entrance process of the customer is a non-homogeneous Poisson process, and the claim process is a renewal process. The loss process of the single-risk model is a random sum of stochastic processes, and the actual individual claim sizes are described as extended upper negatively dependent (EUND) structure with heavy tails. We derive precise large deviations for the loss process of the multi-risk model after giving the precise large deviations of the single-risk model. Our results extend and improve the existing results in significant ways.

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

Polishing of ferrule endfaces of the plastic optical fiber connector for automobiles (자동차용 POF 광커넥터 페룰 단면 연마공정 연구)

  • Jeong M.Y.;Kim C.S.;Lee H.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.468-472
    • /
    • 2005
  • This paper is to investigate the influence of the endface quality on the loss characteristics of a plastic optical fiber connector for in-car network service. Using the parameters of the surface roughness and applied load, insertion loss of connector is measured. Due to scattering and change of refractive index, an optimal condition for low-loss coupling exists. We present the optimal condition as surface roughness $R_{rms}$ = 8 nm and contact load up to 50 N.

  • PDF