• Title/Summary/Keyword: Myocardial SPECT

Search Result 183, Processing Time 0.019 seconds

New Imaging Techniques in Myocardial Perfusion SPECT (심근 관류 SOECT의 새로운 방법)

  • Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • Gated myocardial SPECT and attenuation correction gave birth to new insights into the pathophysiology of ischemic myocardial perfusion and function in clinical routine practice. Gated myocardial Tc-99m-compound SPECT improved diagnostic accuracy of coronary artery disease and enabled us to observe motion and thickening of myocardial walls as well as myocardial perfusion at the same time. Quantitative and qualitative assessment of myocardial performance and perfusion let us to understand the myocardial physiology in ischemia and infarction. In every patient who underwent gated perfusion SPECT, we will find ejection fraction, left ventricular volumes and regional wall motion. There are hopes to use gated TI-201 SPECT for the same purpose and to use gated SPECT for evaluation of wall motion and thickening at stress or immediate post-stress. Attenuation correction could improve diagnostic accuracy mainly by increasing normalcy ratio or performance of non-expert physicians. Both gated methods and attenuation correction improved specificity of non-expert physicians in diagnosing patients with moderate pretest likelihood. New imaging techniques will fill the desire of cardiologists to examine function and perfusion, and possibly metabolism in their clinical routine practice.

  • PDF

Quantification of Myocardial Perfusion and Function Using SPECT and PET (SPECT와 PET을 이용한 심장관류 및 기능의 정량화)

  • Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.75-81
    • /
    • 2005
  • Myocardial perfusion and function can be quantified using SPECT and PET. There was controversy over the usefulness of the correction techniques for physical artifacts, such as photon attenuation and scatter, in the quantification of myocardial perfusion using SPECT. However, the cumulated results of many investigations have leaded the consensus on the usefulness of the correction procedures to improve the accuracy and specificity of the myocardial SPECT in the assessment of coronary artery diseases. Although the clinical value of the myocardial perfusion PET has not been preyed yet, the absolute myocardial blood flow and perfusion reserve values quantified using myocardial PET are employed in many basic investigations. In this paper, the methods for the quantitative myocardial SPECT and PET will be reviewed.

Quantitative gated myocardial perfusion SPECT (정량적 게이트 심근관류 SPECT)

  • Ahn, Byeong-Cheol
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.4
    • /
    • pp.207-218
    • /
    • 2003
  • Myocardial perfusion imaging has been increasingly used to provide prognostic data and guidance on the choice of appropriate management of patients with known or suspected coronary artery disease. The electrocardiogram gated myocardial SPECT program is corning into wide use with an advent of $^{99m}Tc-labeled$ tracers and an improvement of SPECT machines. The gated technique permits measurement of important cardiac prognostic indicators without any further discomforts or radiation burden in patients underwent standard myocardial perfusion SPECT. In addition, gated study significantly improves diagnostic yield by reducing the number of borderline interpretations and could find myocardial stunning and viable myocardium. Gated single photon emission computed tomography (SPECT) imaging allows the automated calculation of end-diastolic volume, end-systolic volume, ejection fraction, myocardial mass and the assessment of regional wall motion and thickening, and it have dramatically improved assessment of coronary artery disease in routine nuclear practice. This allows the simultaneous assessment of both perfusion and function within the same acquisition, and serves as a cost-effective technique for providing more diagnostic data with fewer diagnostic tests. Because the diagnostic and prognostic power derived from knowledge of left ventricular function can be added to that provided by assessing myocardial perfusion, gated SPECT imaging has rapidly gained widespread acceptance and is now used on a routine clinical basis in a growing number of laboratories, including South Korea. The gated SPECT technique for measurement of left ventricular parameters has been validated against a variety of well established techniques. In this work, overview of gated myocardial perfusion SPECT focus on functional parameters is presented.

Usefulness of Myocardial Perfusion SPECT after Percutaneous Coronary Intervention (PCI) (경피적 관상동맥 중재술(Percutanerous Coronary Intervention; PCI) 후 심근 관류 SPECT의 유용성)

  • Lee, Jong-Jin;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.114-117
    • /
    • 2005
  • As the indication of percutaneous coronary intervention (PCI) has expanded to the more difficult and complicated cases, frequent restenosis is still expected after PCI. According to AHA/ACC guideline of the present time, routine use of myocardial perfusion single photon emission tomography (SPECT) is not recommended after coronary intervention, but symptom itself or exercise EKG is not enough for the detection of restensis or for the prediction of event-free survival. In high risk and/or symptomatic subjects, direct coronary angiography is required myocardial perfusion SPECT could detect restenosis in 79% of the patients if performed 2 to 9 months after PCI. Reversible perfusion decrease in the myocardial perfusion SPECT is known to be the major prognostic indicator of major adrerse cardiac event in PCI patients and also the prognosis is benign in the patients without reversible perfusion decrease. Though the cumulated specificity is 79% in the literature and optimal timing of myocardial perfusion SPECT is in controversy, SPECT is recommended even in asymptomatic patients at 3 to 9 months after PCI. Considering the evidences recently reported in the literature, myocardial perfusion SPECT is useful for risk stratification and detection of coronary artery restenosis requiring re-intervention in the asymptomatic patients after PCI.

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Comparison of Emergency Tc-99m Sestamibi Myocardial Perfusion SPECT and ECG in the Diagnosis of Acute Myocardial Infarction (급성심근경색증 환자에서 응급으로 시행한 Tc-99m Sestamibi 심근관류 SPECT와 심전도의 비교)

  • Cho, Ihn-Ho;Lee, Hyoung-Woo;Park, Jong-Sun;Won, Kyu-Chang;Do, Jun-Young;Sin, Dong-Gu;Yoon, Kyung-Woo;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.104-111
    • /
    • 1996
  • We did Tc-99m sestamibi myocardial perfusion SPECT in 36 patients with acute myocardial infarction when they arrived at the emergency room. And we compared myocardial perfusion images with ECG findings. Then we obtained the follows. The myocardial infarction by the obstruction of left coronary descending artery and right coronary artery showed a good concordance in the diagnosis and infarction site between myocardial perfusion images and ECG findings. The 7 patients with myocardial infarction by a left circumflex coronary artery showed a perfusion defect in the lateral wall in myocardial perfusion SPECT images. But 4 patients of them showed ST segment elevation, 2 patients showed ST depression and 1 patient showed normal ECG findings. The diagnostic sensitivity of Tc-99m sestamibi myocardial perfusion SPECT was 100% by a qualified analysis. The perfusion defect site in the myocardial perfusion SPECT were corresponded with the infarct related coronary artery in 31 patients which was diagnosed by coronary angiograpy. The size of perfusion defect in the po1ar map was $31{\pm}18%(M{\pm}SD)$, in the myocardial infarction with left anterior descending coronary arery obstruction, $31{\pm}13% (M{\pm}SD)$ in the myocardial infarction with right coronary artery obstruction and $25{\pm}5.9%(M{\pm}SD)$ in the myocardial infarction with left circumflex coronary artery obstruction. We concluded that emergency myocardial perfusion SPECT images are useful in the diagnose of myocardial infarction and it's very useful when we are difficult to diagnose with ECG like as lateral wall infarction or left bundle branch block.

  • PDF

Myocardial SPECT Imaging of Post-Infarction Ventricular Aneurysm (심근경색 후 생긴 심실류의 심근 SPECT소견)

  • Koh, Eun-Mi;Lee, Kyung-Han;Um, Jae-Ho;Kim, Myung-Ah;Oh, Byung-Hee;Park, Young-Bae;Lee, Myung-Chul;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.19-25
    • /
    • 1989
  • To assess the usefulness of myocardial SPECT imaging to detect post-myocardial infarction ventricular aneurysms, we analyzed the Technetium-99m MIBI myocardial SPECT images of 16 patients with anterior and/or apical infarction, 9 had the previously reported findings of failure of convergence of the left ventricular walls toward the apex on SPECT images and 8 of them also had ventricular aneurysms. The ventriculography of the 2 patients with mixed pattern revealed 1 case of ventricular aneurysm and 1 case without aneurysm. Among the remaining 5 pateints with converging pattern, none had ventricular aneurysm. Of the other 11 pateints with inferior and/or lateral wall infarction, 1 patient had ventricular aneurysm and the SPECT image couldn't detect the aneurysm. $Department of Internal Medicine, College of Medicine, Seoul National University$ myocardial SPECT images for the detection of ventricular aneurysm had a sensitivity of 90 %, a specificity of 88%, and an accuracy of 89%. Thus we could get the information about presence of ventricular aneurysm as well as the status of the myocardial perfusion from the Tc-99m MIBI myocardial SPECT images.

  • PDF

Diagnosis of Coronary Artery Disease Using Myocardial Perfusion SPECT (심근 SPECT를 이용한 관상동맥질환의 진단)

  • Won, Kyoung-Sook;Kim, Hae-Won
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.196-202
    • /
    • 2009
  • Myocardial perfusion scintigraphy is currently by far the most commonly performed cardiac nuclear study, constituting approximately one third of all nuclear medicine procedure. It plays an important role in the diagnosis, prognosis, risk assessment and management of heart disease. Aim of this review is to describe recent evolution of myocardial perfusion imaging on the focus of diagnosis of coronary artery disease. In addition, current status of other imaging modalities will be reviewed.

Diagnostic Accuracy and Evaluation of Myocardial Viability by Cardiac Magnetic Resonance Imaging in Acute Myocardial Infarction: A Comparison with Thallium-201 Myocardial SPECT (급성심근경색증에서의 심장자기공명영상술의 진단 정확도와 심근 생존력 평가: TI-201 심근관류 SPECT와의 비교)

  • Kim Hye-seon;Park Dong Woo;Kim Yongsoo;Kim Young-sun;Choi Yo Won;Jeon Seok Chul;Seo Heung Suk;Hahm Chang Kok;Kim Soon Kil;Ahn You hern;Choi Yoon Young;Park Choong-Ki
    • Investigative Magnetic Resonance Imaging
    • /
    • v.7 no.2
    • /
    • pp.100-107
    • /
    • 2003
  • Purpose : To assess the usefulness of cardiac MR imaging (MRI) in the diagnosis of acute myocardial infarction and in the assessment of myocardial viability in comparision with T1-201 SPECT. Materials and Methods : We retrospectively studied 17 patients who complained of chest pain and dyspnea with cardiac MRI . The patients were evaluated for the presence or absence of high signal intensity on T2-weighted image (T2wI), abnormal wall motion on 2D-FIESTA, perfusion defect on Gd-DTPA enhanced T1WI, and delayed myocardial enhancement on 15-minutes delay Gd-DTPA enhanced T1WI. The results were correlated with the images on T1-201 SPECT, taken at rest and stress, through which reversibility of perfusion defect was assessed. Results : Both cardiac MRI and T1-201 SPECT proved to be useful methods for diagnosing acute myocardial infarction. In order of decreasing correspondence, T2WI, T1-201 SPECT, delayed enhancement study, and wall motion images all showed significant statistical correlation with the clinical diagnosis of myocardial infarction. Perfusion MRI, on the other hand, showed no significant statistical difference was found between T1-201 SPECT and cardiac MRI. The results on T2WI showed high accordance with those on Tl-201 SPECT, while delayed myocardial enhancement and wall motion studies showed no agreement with Tl-201 SPECT. Conclusion : Cardiac MRI is useful method for diagnosis of acute myocardiac infarction. With respect to the assessment of myocardial viability, the results obtained on cardiac MRI showed high agreement with those on Tl-201 SPECT. However, further study is necessary at this point for standardization and establishment of the methods for assessing myocardial viability on cardiac MRI.

  • PDF

Compared Performance of Semiconductor SPECT in Myocardial Perfusion SPECT: Phantom study (범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구)

  • Bahn, Young Kag;Hwang, Dong Hoon;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.49-53
    • /
    • 2016
  • Purpose Recently, Cadmium-zinc-telluride (CZT) semiconductor myocardial SPECT (Single Photon Emission Computed Tomography) has been used myocardial scintigraphy. In this study, the performance of Semiconductor SPECT and conventional SPECT systems was compared by a comprehensive analysis of phantom SPECT images. Materials and Methods Methods: We evaluated the DSPECT CZT SEPCT (Spectrum-dynamic) and INFINA conventional (GE). Physical performance was compared on reconstructed SPECT images from a phantom. Results For count sensitivity on cardiac phantom images ($counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$), DSPECT had a sensitivity of conventional SPECT. This classification was similar to that of myocardial counts normalized to injected activities from phantom images (respective mean values, $counts{\cdot}sec^{-1}{\cdot}MBq^{-1}$: 195.83 and 52.83). For central spatial resolution: DSPECT, 9.47mm; conventional SPECT, 16.90mm. For contrast-to-noise ratio on the phantom: DSPECT, 4.2; conventional SPECT, 3.6. Conclusion The performance of CZT cameras is dramatically higher than that of conventional SPECT. However, CZT cameras differ in that spatial resolution and contrast-to-noise ratio are better with conventional SPECT, whereas count sensitivity is markedly higher with the DSPECT.

  • PDF