• 제목/요약/키워드: Mycosis fungoides

검색결과 12건 처리시간 0.018초

Development and Evaluation of a Thimble-Like Head Bolus Shield for Hemi-Body Electron Beam Irradiation Technique

  • Shin, Wook-Geun;Lee, Sung Young;Jin, Hyeongmin;Kim, Jeongho;Kang, Seonghee;Kim, Jung-in;Jung, Seongmoon
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.152-157
    • /
    • 2022
  • Background: The hemi-body electron beam irradiation (HBIe-) technique has been proposed for the treatment of mycosis fungoides. It spares healthy skin using an electron shield. However, shielding electrons is complicated owing to electron scattering effects. In this study, we developed a thimble-like head bolus shield that surrounds the patient's entire head to prevent irradiation of the head during HBIe-. Materials and Methods: The feasibility of a thimble-like head bolus shield was evaluated using a simplified Geant4 Monte Carlo (MC) simulation. Subsequently, the head bolus was manufactured using a three-dimensional (3D) printed mold and Ecoflex 00-30 silicone. The fabricated head bolus was experimentally validated by measuring the dose to the Rando phantom using a metal-oxide-semiconductor field-effect transistor (MOSFET) detector with clinical configuration of HBIe-. Results and Discussion: The thimble-like head bolus reduced the electron fluence by 2% compared with that without a shield in the MC simulations. In addition, an improvement in fluence degradation outside the head shield was observed. In the experimental validation using the inhouse-developed bolus shield, this head bolus reduced the electron dose to approximately 2.5% of the prescribed dose. Conclusion: A thimble-like head bolus shield for the HBIe- technique was developed and validated in this study. This bolus effectively spares healthy skin without underdosage in the region of the target skin in HBIe-.

열형광선량계와 반도체검출기를 이용한 전신피부전자선조사의 선량평가 (The evaluation of dose of TSEI with TLD and diode dector of the uterine cervix cancer)

  • 제영완;나경수;윤일규;박흥득
    • 대한방사선치료학회지
    • /
    • 제17권1호
    • /
    • pp.57-71
    • /
    • 2005
  • 목적 : 전자선을 이용하여 전신피부를 치료할 경우, 조사되는 피부선량과 정확도를 열형광 선량계(TLD)와 반도체(Diode) 검출기를 이용하여 평가하고자 한다. 대상 및 방법 : 본원에 내원한 다발성 발적을 보이는 균상식육종(Mycosis fungoides) 환자를 대상으로 스텐포드 테크닉(Stanford technique)을 시행하였다. 선형가속기의 6MeV 전자선을 SSD 300 cm에서 0.8 cm의 아크릴 스포일러를 사용하여 6개 자세로 각 자세 당 gantry각도 $64^{\circ}.\;90^{\circ}.\;116^{\circ}$로 각각 조사하면서 열형광 선량계와 반도체검출기를 이용하여 환자피부선량과 출력을 동시에 $5{\sim}6$회 측정하였다. 결과 : 열형광선량계의 측정결과 종양선량과 오차는 조사중심부(C.A) $+\;6\%$, 대퇴부(thigh) $+\;8\%$, 배꼽(umbilicus) $+\;4\%$, 종아리(calf) $-\;8\%$, 두정부(vertex) $-\;74.4\%$, 액와부(deep axillae) $-\;10.2\%$, 항문(anus)과 고환(testis) $-\;87\%$, 발바닥(sole) $-\;86\%$로 나타났다. 손톱과 발톱은 4 mm납으로 차폐하여 $+\;4\%$로 나타났다. 반도체검출기의 측정결과 선량오차는 환자조사중심부에서 $-\;4.5\%{\sim}+\;5\%$, 스포일러에 부착한 경우 $-\;1.1\%{\sim}+\;1\%$로 나타났다. 결론 : 열형광선량계의 측정결과, 전신피부의 선량오차는 $+\;8\%{\sim}-\;8\%$로 허용오차인 ${\pm}10\%$의 범위를 만족시키는 선량분포를 보였으며, 저선량 부위에는 여러 개의 열형광선량계로 측정하여 추가선량과 조사야 크기를 결정하여 두정부, 회음부, 양쪽 발바닥에 추가조사 하였다. 스포일러에서 측정한 전자선출력은 안정되었고, 환자조사 중심부에서 측정한 반도체 검출기의 선량오차는 검출기 부착위치재현과 환자자세재현 등에 의해 기인된 것으로 사료된다.

  • PDF